Reference Guide

cfgEmailAlertIndex (Read Only)
Description
The unique index of an alert instance.
Legal Values
1–4
Default
<instance>
cfgEmailAlertCustomMsg (Read or Write)
Description Specifies a custom message that forms the subject of the alert.
Legal Values
A string of up to 32 characters
Default
<blank>
cfgEmailAlertEmailName (Read Only)
Description Specifies name or other identifier associated with the destination email address. The email name can refer to an
individual, group, location, department, and so on.
Legal Values
A string of up to 32 characters
Default
<blank>
Example
racadm getconfig -g cfgEmailAlert -i 2
# cfgEmailAlertIndex=1
cfgEmailAlertEnable=1
cfgEmailAlertAddress=kfulton@dell.com
cfgEmailAlertName=Kevin Fulton
cfgSessionManagement
This group contains parameters to configure the number of sessions that can connect to iDRAC. One instance of the group is allowed.
Displays current settings for and configures the idle timeout properties for web server, Telnet, SSH and RACADM sessions. Changes to
idle time out settings take effect at the next login. To disable the idle time out property for a connection, set this property to 0.
The following sections provide information about the objects in the cfgSessionManagement group.
cfgSsnMgtRacadmTimeout (Read or Write)
Description
Defines the idle timeout in seconds for the Remote RACADM interface. If a remote RACADM session remains
inactive for more than the specified sessions, the session closes.
Legal Values
10–1920
Default
60
Example
racadm getconfig -g cfgSessionManagement cfgSsnMgtWebserverTimeout=0
cfgSsnMgtTelnetIdleTimeout=0
cfgSsnMgtSshIdleTimeout=1800
cfgSsnMgtRacadmTimeout=0
iDRAC Property Database Group and Object Descriptions
163