Reference Guide

cfgSDWriteProtect (Read Only)
Description
Displays if the physical write protect latch on the SD card is enabled or disabled.
NOTE: This command is deprecated from 12G iDRAC 1.0 release onwards. The functionality of this
command is covered by cfgVFlashSDWriteProtect. While execution of the cfgSDWriteProtect
command is successful, use the cfgVFlashSDWriteProtect command. For more information, see
cfgVFlashwriteProtect (Read Only).
Legal Values
1 (TRUE)
0(FALSE)
Default
0
cfgServerInfo
This group allows you to select the BIOS first boot device and provides the option to start the selected device only once.
Use this object with the config or getconfig subcommands.
The following sections provide information about the objects in the cfgServerInfo.
cfgServerName (Read Or Write)
Description
Displays the name of the specified server.
Legal Values
Maximum of 15 non-extended (ASCII characters (ASCII codes 32 through 126). For more information, see
Guidelines to quote strings containing special character.
Default
SLOT — <slot number>
cfgServerNic3MacAddress (Read Only)
Description
Displays the MAC address of the server NIC 3.
Legal Values
None
Default
None
cfgServerNic4MacAddress (Read Only)
Description
Displays the MAC address of the server NIC 4.
Legal Values
None
Default
None
cfgServerDNSIMCName (Read or Write)
Description
Displays the DNS domain name for iDRAC or IMC.
Legal Values
A valid string values
Default
None
174 iDRAC Property Database Group and Object Descriptions