cfgServerPowerSupply
This group contains information related to the power supplies.
The cfgServerPowerSupply object group is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on
Blade Servers.
NOTE: The getconfig subcommand always shows eight cfgServerPowerSupply indexes, even if two power
supplies are installed in the system or the system supports a maximum of two PSUs. For the uninstalled and
unsupported units, all the objects in the cfgServerPowerSupply group displays a value of 0.
The following sections provide information about the objects in the cfgServerPowerSupply group.
cfgServerPowerSupplyCurrentDraw (Read Only)
Description
Displays the instantaneous current consumption in 0.1 amps.
Legal Values
A string of up to 32 characters.
Default
0
cfgServerPowerSupplyFwVer (Read Only)
Description
Displays the firmware version of the PSU, in the format x.xx.xxx.
Legal Values
A string up to 8 characters.
Default
Null
cfgServerPowerSupplyIndex
Description
Specifies index of the PSU.
NOTE: Indexes 1–8 are supported to support up to 8 PSUs. If any PSU is not present then
cfgServerPowerSupplyOnlineStatus does not exist and for all the other properties, it is 0.
Legal Values
Integer 1–8
Default
None
cfgServerPowerSupplyMaxInputPower (Read Only)
Description
Displays the AC input rated power in Watts.
Legal Values
A string of up to 32 characters.
Default
0
cfgServerPowerSupplyMaxOutputPower (Read Only)
Description
Displays the AC output rated power in Watts.
Legal Values
A string of up to 32 characters.
196 iDRAC Property Database Group and Object Descriptions