Reference Guide

It is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers.
cfgIpmiSerialBaudRate (Read or Write)
Description
Specifies the baud rate for a serial connection over IPMI.
Legal Values
9600, 19200, 57600, 115200
Default
57600
cfgIpmiSerialChanPrivLimit (Read or Write)
Description
Specifies the maximum privilege level allowed on the IPMI serial channel.
Legal Values
2 (User)
3 (Operator)
4 (Administrator)
Default
4
cfgIpmiSerialConnectionMode (Read or Write)
Description
When the iDRAC cfgSerialConsoleEnable property is set to 0(disabled), the iDRAC serial port becomes the
IPMI serial port. This property determines the IPMI defined mode of the serial port.
In Basic mode, the port uses binary data with the intent of communicating with an application program on the serial
client. In Terminal mode, the port assumes that a dumb ASCII terminal is connected and allows simple commands to
be entered.
Legal Values
0(Terminal)
1(Basic)
Default
1
cfgIpmiSerialDeleteControl (Read or Write)
Description
Enables or disables delete control on the IPMI serial interface.
Legal Values
0 (FALSE)
1 (TRUE)
Default
0
cfgIpmiSerialEchoControl (Read or Write)
Description
Enables or disables echo control on the IPMI serial interface.
Legal Values
0(FALSE)
1 (TRUE)
Default
1
204 iDRAC Property Database Group and Object Descriptions