Reference Guide

Example
racadm getconfig -g cfgNetTuning
cfgNetTuningNicSpeed=100
cfgNetTuningNicFullDuplex=1
cfgNetTuningNicMtu=1500
cfgNetTuningNicAutoneg=1
cfgNetTuningNic100MB (Read or Write)
Description
Specifies the speed for iDRAC NIC.
NOTE: To set this property:
iDRAC NIC selection must be set to Dedicated mode.
iDRAC NIC Auto negotiation must be disabled.
iDRAC IPv4 must be enabled.
iDRAC IPv4 DHCP must be enabled.
iDRAC IPv6 must be enabled.
iDRAC IPv6 auto configuration must be enabled.
Legal Values
0 (10 MBit)
1 (100 MBit)
2 (1000 MBit)
NOTE: You cannot manually set the Network Speed to 1000 MBit. This option is available only if
cfgNetTuningNicAutoNeg is set to 1 (Enabled).
Default
1
cfgNetTuningNicFullDuplex (Read or Write)
Description
Specifies the duplex setting for the NIC.
Legal Values
0 (Half Duplex)
1 (Full Duplex)
Default
1
Dependency
None
cfgNetTuningNicMtu (Read or Write)
Description
Indicated the maximum size of units in bytes transmitted by NIC.
Legal Values
576–1500
Default
1500
cfgSensorRedundancy
This group is used to set the power supply redundancy.
The following sections provide information about the objects in the cfgSensorRedundancy group.
iDRAC Property Database Group and Object Descriptions
207