System.Power.Hotspare.PrimaryPSU (Read or Write)
Description
Represents the primary PSU selection.
NOTE: This object is supported only for iDRAC on Rack and Tower servers.
Legal Values
1 — PSU1
2 — PSU2
5 — PSU1 and PSU3
10 — PSU2 and PSU4
Default Value Not Applicable
Write Privilege
Configure iDRAC
License Required
iDRAC Express or iDRAC Enterprise
Dependency
None
System.Power.Max.Amps (Read Only)
Description
Specifies the device Peak Power Consumption since this value was last cleared.
Legal Values
Values: 1–65535.
Default Value
Current peak power consumption
Write Privilege Not Applicable
License Required
iDRAC Express or iDRAC Enterprise
Dependency
None
System.Power.Max.Amps.TimeStamp (Read Only)
Description
Specifies the timestamp recorded for the Peak Power Consumption since this value was last cleared.
Legal Values
String up to 254 ASCII characters.
Default Value
Timestamp of the current peak power consumption
Write Privilege Not Applicable
License Required
iDRAC Express or iDRAC Enterprise
Dependency
None
System.Power.Max.Headroom (Read Only)
Description
Displays the difference between the available power and the peak power consumption.
NOTE: This object is not applicable on iDRAC on Modular servers.
Legal Values
Values: 1–65535
Default Value
Difference between the available power and the peak power consumption.
Database Objects With Get and Set Commands 233