Reference Guide

Dependency None
iDRAC.Racadm
To manage Remote RACADM connection settings, use the object in this group.
iDRAC.Racadm.Enable (Read or Write)
Description
Enables or disables Remote RACADM interface.
Legal Values
0 — Disabled
1 — Enabled
Default Value Enabled
Write Privilege
Configure iDRAC
License Required
iDRAC Express or iDRAC Enterprise
Dependency
None
iDRAC.Racadm.Timeout (Read or Write)
Description
Defines the idle timeout in seconds of the Remote RACADM interface.
Legal Values
0 — No timeout
Integral values: 60–10800
Default Value 60
Write Privilege
Configure iDRAC
License Required
iDRAC Express or iDRAC Enterprise
Dependency
None
iDRAC.Redfish
The objects in this group provide configuration parameters for the Redfish interface to iDRAC.
iDRAC.Redfish.Enable (Read or Write)
Description
Enables or disables Redfish service on iDRAC.
Legal Values
0 — Disabled
1 — Enabled
Default Value
1 — Enabled
Write Privilege
Configure iDRAC
License Required
RACADM
Dependency
None
Database Objects With Get and Set Commands 299