Reference Guide

NIC.IscsiInitiatorParams.IscsiInitiatorSubnetPrefix (Read
or Write)
Description
Specifies the IPv6 Subnet Mask Prefix of the iSCSI initiator.
Legal Values
String of 2–39 characters (IPv6 Subnet)
Default Value Not Applicable
Write Privilege
Server Control
License Required
iDRAC Express or iDRAC Enterprise
Dependency
Not available if VndrConfigGroup.iSCSIBootSupport is unavailable.
NIC.IscsiSecondaryDeviceParams
The following section provides information about the objects in the NIC.IscsiSecondaryDeviceParams group.
NIC.IscsiSecondaryDeviceParams.SecondaryDeviceMacAd
dr (Read or Write)
Description
Specifies the MAC address of a secondary iSCSI boot adapter for redundancy in case if start is unsuccessful.
Legal Values
String of up to 17 characters
Default Value Not Applicable
Write Privilege
Server Control
License Required
iDRAC Express or iDRAC Enterprise
Dependency
Not available if VndrConfigGroup.iSCSIBootSupport is unavailable.
NIC.IscsiSecondaryDeviceParams.UseIndTgtName (Read
or Write)
Description
Specifies whether to use Independent Target Name when multipath I/O is enabled.
Legal Values
Enabled
Disabled
Default Value
Disabled
Write Privilege
Server Control
License Required
iDRAC Express or iDRAC Enterprise
Dependency
Not available if VndrConfigGroup.iSCSIBootSupport is unavailable.
Database Objects With Get and Set Commands 441