Reference Guide

Storage.Controller.BackgroundInitializationRate (Read or
Write)
Description The Background Initialization (BGI) rate is the percentage of the system's resources dedicated to perform the
background initialization of a virtual disk after it is created.
Legal Values Values: 0–100
Default value 100
Write Privilege Server Control
License Required iDRAC Express or iDRAC Enterprise
Dependency None
Storage.Controller.BatteryLearnMode (Read Only)
Description Battery Learn Mode controls a RAID controller's Battery Learn Cycle.
Legal Values
Automatic
Warn
Disabled
Not Supported
Default value None
Write Privilege Server Control
License Required iDRAC Express or iDRAC Enterprise
Dependency A battery must be present on the controller.
Storage.Controller.CheckConsistencyMode (Read or
Write)
Description
Check Consistency feature is used to verify the accuracy of the redundant (parity) information.
Legal Values
Normal
Stop On Error
Default value Normal
Write Privilege Server Control
License Required iDRAC Express or iDRAC Enterprise
Dependency None
Storage.Controller.CheckConsistencyRate (Read or Write)
Description
The Check Consistency rate is the percentage of the system's resources dedicated to performing a check
consistency on a redundant virtual disk.
Legal Values Values: 0–100
Default value 100
Write Privilege Server Control
License Required iDRAC Express or iDRAC Enterprise
Database Objects With Get and Set Commands 459