Reference Guide

Input get — Displays the list of eventfilter settings.
set — Configures the actions and notifications for a given eventfilter configuration.
-i — Message ID for which the simulation is needed.
-c — Alert category of the specific event filter.
-a — The action that must be invoked when the event occurs. Valid values are none, powercycle, power
off, or systemreset.
-n — The notification is sent when the event occurs. Valid values are all, snmp, ipmi, ws-events, oslog,
email, remotesyslog or none. You can append multiple notifications separated by a comma. You cannot
enter the values all or none with other notifications. If incorrect notification is specified along with other valid
notifications, the valid and invalid notification set is failed.
-r — Event generation interval. This option is applicable only to the temperature statistics subcategory tmps.
You can use this option as a stand-alone or with -n and -a.
NOTE: If both event generation interval and notifications are configured and there is an error while
configuring the notifications, the event generation interval is not set. The valid values are 0–365. 0
disables the event generation.
RACADM Subcommand Details 53