Reference Guide

Input
—i — Displays the number of entries in the SEL.
-s — Displays the starting record number.
-c — Specifies the number of records to display.
--more — Displays a screen.
-A — Does not display headers or labels.
-o — Displays each record on a single line..
-E — Displays RAW SEL data along with the other data.
-R — Displays only the RAW SEL data for each record
Example Display entire log.
racadm getsel
Display number of records in log.
racadm getsel -i
getsensorinfo
Description Displays the status for system sensors.
NOTE: For the Dell PowerEdge FX2 chassis with the
FM120x4 server, the power-related information is not
displayed.
Synopsis
racadm getsensorinfo
racadm getsensorinfo -c
Input -c—Compact output format.
NOTE: Chassis Controller is supported only on Dell PowerEdge FX2, and GPU sensors are displayed only on PowerEdge
C4130 servers.
Example
racadm getsensorinfo
Sensor Type : POWER
<Sensor Name>
<Status> <Type>
PS1 Status Present AC
Sensor Type : TEMPERATURE
<Sensor Name>
<Status> <Reading> <lc> <uc> <Inc>[R/W] <Unc>[R/W]
System Board
Inlet Temp
Ok 20 C -7 C 47 C 3 C [Y] 42C [Y]
System Board
Exhaust Temp
Ok 19 C 0 C 75 C 0 C [N] 70 C [N]
CPU1 Temp Ok 59 C 3 C 97 C 8 C [N] 92 C [N]
Sensor Type : FAN
<Sensor Name>
<Status> <Reading> <lc> <uc> <PWM %>
System Board
Fan1 RPM
Ok 5880 RPM 600 RPM NA 21%
RACADM Subcommand Details 69