Release Notes

16. Ensure that the SSH client is updated to the latest version. Following SSH configurations are no longer available on iDRAC:
KEX algorithms:
a. diffie-hellman-group14-sha1
MAC:
a. umac-64
b. umac-64-etm@openssh.com
17. This note is applicable only to PowerEdge M640 and FC640. When performing BIOS Recovery operation, host may not power on. To
recover from this condition, perform a virtual/physical reseat operation of the blade server.
18. After updating the iDRAC firmware to version 3.30.30.30 or later, LC logs may display Message ID PR36 that "Version change
detected for PCIe SSD firmware. Previous version:X.X.X, Current version:X.X.X." This is due to a change in the naming convention.
Please ignore the log entry.
19. After downgrading the iDRAC firmware from version 3.30.30.30 to any previous versions, storage page and drives may display
warnings. To resolve the issue, reset iDRAC using the 'racreset' command.
20. This note is applicable only to PowerEdge R540. While updating the BIOS firmware through local RACADM with local share, you may
get an error "ERROR: RAC989: Unable to apply the BIOS_3P4XY_WN64_1.6.11.EXE firmware update." Use the direct DUP installation
or installation through CIFS/NFS share to update the BIOS firmware.
21. If you get an error while performing SupportAssist collection through RACADM using HTTPS share, use the following commands to
perform the collection:
a. Racadm supportassist collect
racadm supportassist collect -t Sysinfo
b. Racadm supportassist exportlastcollection
racadm supportassist exportlastcollection -l <https> -u <username> -p <password>
22. Features including Server Management Command Line Protocol (SMCLP) and Virtual Media Command Line Interface (VMCLI) will be
deprecated in the later releases.
23. The LifeCycle Controller GUI features available on your system depends on the license installed. Some features that are mentioned in
the GUI or documentation may be unavailable on your system.
24. For improved support on drives and operating system deployment, it is recommended to use the UEFI BIOS boot mode.
25. To create a virtual disk or deploy an operating system, ensure that you use the Dell supported SATA, SAS, or NVMe drives. For more
information, see the documentation for BIOS, controller, and drive.
26. In the software inventory, the hash value for iDRAC firmware is displayed as NA instead of hash.
27. If SMBv2 share fails in Lifecycle GUI, ensure that:
the Digitally sign communications option is disabled
permissions to access the folder/file are granted
folder/file name does not have a space
share contains fewer files and folders
28. If you see iSM0050 event in LC log, then ensure that you update the iDRAC Service Module (iSM) to version 3.4 or to a TLS-capable
iSM. iSM without TLS capability is not supported on iDRAC firmware version 3.30.30.30 or above.
29. While iDRAC is initializing, all communications with iDRAC may fail. For any service requests, wait until the initialization process is
complete.
30. In iDRAC, firmware version 3.30.30.30 or later, if there is no link detected in the selected iDRAC port then the iDRAC IP is displayed as
0.0.0.
31. WX3200 AMD GPU card currently doesnot support I2C interface for temperature sensors. Hence, temperature readings will not be
available for this card from iDARC interfaces.
12
Important notes