Release Notes

Known issues — To be fixed in future releases
Storage devices not found in iDRAC
Description If you disable the external slot that is connected to PERC, iDRAC will not detect the PERC card or storage
devices present in the server.
Workaround Remove the PERC card from the external slot that needs to be disabled and powercycle the system.
Systems affected All system supported by this release.
Tracking number 113901
Hot-plugged PCIe SSDs not detected
Description Removing all PCIe SSDs connected behind a particular PCIe Extender and performing a warm reboot may cause
iDRAC to not detect subsequent hot-plugs on that extender.
Workaround With the hot-plugged drive(s) still in the system, perform a cold reboot of the host.
Systems affected All system supported by this release.
Tracking number 116735
NIC or FC device slot listed in hardware inventory
even when disabled in BIOS
Description
For some NIC or FC cards, even when the device slot is disabled in BIOS, the slot may still get listed in the
hardware inventory.
Workaround N/A
Systems affected All system supported by this release.
Tracking number 104535
<Keyboard_Mouse_USB_reset_warning> button in
Virtual Console with Java plug-in
Description
Button does not display the localized name, you may see the button's English variable name with no online help
support. The intent of this button is to reset keyboard mouse functionality without having user to restart the
Virtual Console
Workaround Keyboard and Mouse reset functionality works. Does not disrupt the end user experience, only impairs the
aesthetic.
Systems affected All systems supported by this release.
Tracking number 119759