Release Notes

Systems affected All system supported by this release.
Tracking number 121977
Unable to set Power cap values in Lockdown mode
Description While the system is in lockdown mode, setting the power cap values may fail.
Workaround Disable lockdown mode.
Systems affected All system supported by this release.
Tracking number 120534
Incorrect firmware version displayed after the
update
Description If a single DUP is used to update firmware for multiple devices, and if any one update fails then the firmware for
the subsequent cards may display an incorrect version.
Workaround Update the firmware for all the failed devices again.
Systems affected All system supported by this release.
Tracking number 110415
iDRAC not detecting Virtual disks in eHBA Mode
Description
iDRAC is not detecting Virtual disks after controller mode is changed from RAID to eHBA as part of Warm Reboot
job.
Workaround Powercycle the system.
Systems affected All system supported by this release.
Tracking number 120820
Legacy attribute
System.Embedded.1#Diagnostics.1#OSAppCollect
ionTime displays incorrect time
Description
This attribute is not referenced for any functionality within iDRAC modules in the 14th Generation systems. You
see an incorrect number, instead of an accurate OS Data Collection Time.
Workaround Run the RACADM command techsupreport getupdatetime
Systems affected All systems supported by this release.
Tracking number 121111
iDRAC Direct Port accessible even after the port is
turned off
Description
You may be able to disable iDRAC Direct USB port from system settings (BIOS) while the iDRAC Direct USB port
is in use.
Known issues — To be fixed in future releases 15