Disk assignment not reflected in iDRAC GUI even
after waiting for about 3-5 minutes
Description After editing an assignment in PowerEdge MX5000s/PowerEdge MX5016s by assigning a drive to a slot, the disk
is not displayed in IDRAC inventory.
Workaround Reset iDRAC using the racreset command.
Systems affected PowerEdge MX740c
Tracking number 122565
Unsupported RAID level displayed
Description While creating a virtual disk (VD) with controller in eHBA mode, unsupported RAID levels may be displayed.
Selecting an unsupported RAID level, may cause the job to fail
Workaround Powercycle the system.
Systems affected All systems supported by this release.
Tracking number 116586
SEL not reporting drive events
Description
In a storage configuration with multiple backplanes, some drive sensors may get disabled resulting in drive events
not being reported in the SEL.
Workaround N/A
Systems affected All systems with multiple backplanes supported by this release.
Tracking number 122290
SEL logs in the setup menu and LC logs in the
iDRAC GUI not matching
Description
Different error messages are logged for memory error rate in iDRAC HII and iDRAC GUI and therefore the logs do
not match.
Workaround Check the LC logs through iDRAC GUI.
Systems affected All systems supported by this release.
Tracking number 119161
MaxReadingRange and MinReadingRange for
Readingvolts attributes displayed incorrectly
Description
Redfish reads the properties MaxReadingRange and MinReadingRange as per DMTF however, the same are not
supported by platform infrastructure for PSU and CPU.
Workaround N/A
Systems affected All systems supported by this release.
Tracking number 119516