Release Notes

Limitations
Authentication
1. LC supports the following characters for username and password:
Alphabets (a-z, A-Z)
Numbers (0-9)
Special characters (-, _, .)
2. If there are no slots available to add a new user in iDRAC, the Group Manager Job for Add New User shows a failure with error
GMGR0047. Use the web interface (iDRAC Settings > Users) to verify the number of iDRAC local users.
3. If the user does not exist on a specific iDRAC, Group Manager Jobs for Change User Password and Delete User show a
failure with error GMGR0047. Use the web interface (iDRAC Settings > Users) to verify that the user exists.
Automation — API and CLI
1. Sometimes, when using WSMan, an Internal SSL Error is reported and the WSMan command fails. If this issue occurs, retry the
command.
2. Using WSMan, the attribute LCD.ChassisIdentifyDuration cannot be set to -1 (indefinite blink). To make the LED blink
indefinitely, use the IdentifyChassis command with IdentifyState=1.
3. RACADM supports the underscore character (_) for iDRAC.SerialRedirection.QuitKey along with the existing symbols
shown in the integrated help.
4. Using remote RACADM, if you use the racadm hwinventory export command to export the hardware inventory using an
incorrect CIFS share, an incorrect message is displayed:
RAC930 : Unable to export the hwinventory. If the issue
persists, restart iDRAC and retry the operation after iDRAC has finished restarting.
5. If iDRAC is in lockdown mode and you run the command 'racadm rollback', followed by the command 'racadm resetcfg', an incorrect
message is displayed: ERROR: A firmware update is currently in progress. Unable to reset the RAC at
this time. Reboot iDRAC to display the correct error message.
6. While using a Top or Skip command, if you enter a value greater than the unsigned long type (4,294,967,295), you may get an
incorrect error message.
7. You cannot use the FQDD of iDRAC (iDRAC.Embedded.1) when changing iDRAC mode from Shared LOM to Dedicated.
BIOS and UEFI
1. When setting the iDRAC Service Module (iSM) monitoring attributes from the web interface, if the BIOS watchdog timer is enabled,
an error may be displayed but the attributes are set. To avoid the error, disable the BIOS watchdog timer or disable the iSM Auto
System Recovery and then apply the attributes.
Hardware
1. In LC, not all the vendor FC cards are supported for VLAN configuration.
2. If an H730P adapter is installed in slot 9 (internal PERC slot) of PowerEdge T640, iDRAC displays it as H730P Integrated RAID
Controller (Embedded).
iDRAC and LC firmware
1. Due to known limitations in OpenSource (SFCB), query filtering with long integers and lengthy strings may not work as expected.
2. LC can import and view an iDRAC license but cannot export or delete the iDRAC license. The iDRAC license can be deleted from
iDRAC web interface.
7
18 Limitations