Users Guide

Enabling or disabling OS to iDRAC Pass-through
using web interface
To enable OS to iDRAC Pass-through using Web interface:
1. Go to iDRAC Settings > Connectivity > Network > OS to iDRAC Pass-through.
The OS to iDRAC Pass-through page is displayed.
2. Change the State to Enabled.
3. Select any of the following options for Pass-through Mode:
LOM — The OS to iDRAC pass-through link between the iDRAC and the host operating system is established through the LOM
or NDC.
USB NIC — The OS to iDRAC pass-through link between the iDRAC and the host operating system is established through the
internal USB bus.
NOTE: If you set the pass-through mode to LOM, ensure that:
OS and iDRAC are on the same subnet
NIC selection in Network Settings is set to LOM
4. If you select LOM as the pass-through configuration, and if the server is connected using dedicated mode, enter the IPv4 address of
the operating system.
NOTE: If the server is connected in shared LOM mode, then the OS IP Address field is disabled.
NOTE: If the VLAN is enabled on the iDRAC, the LOM-Passthrough will only function in shared LOM mode with VLAN
tagging configured on the host.
5. If you select USB NIC as the pass-through configuration, enter the IP address of the USB NIC.
The default value is 169.254.1.1. It is recommended to use the default IP address. However, if this IP address conflicts with an IP
address of other interfaces of the host system or the local network, you must change it.
Do not enter 169.254.0.3 and 169.254.0.4 IPs. These IPs are reserved for the USB NIC port on the front panel when a A/A cable is
used.
6. Click Apply.
7. Click Test Network Configuration to check if the IP is accessible and the link is established between the iDRAC and the host
operating system.
Enabling or disabling alerts using RACADM
Use the following command:
racadm set iDRAC.IPMILan.AlertEnable <n>
n=0 — Disabled
n=1 — Enabled
40
Logging in to iDRAC