Owner's Manual
LASSO-353: Lasso does not parse “Hard Zone” information for FC switches.
LASSO-355: Lasso does not display VLAN and Port information for Ethernet switches.
LASSO-356: Lasso fails to launch when User configuration files, XML and DAT, are not available in the User Profile
directory.
LASSO-357: Lasso Parsing is inconsistent for M1000e Chassis.
LASSO-358: Lasso proxy upload fails in CLI for system in Non Domain with Administrator and domain user login in
Integration authentication with error message.
LASSO-359: Lasso upload in CLI mode with -UX option uploads zip.gpg file instead of xml.gpg file.
LASSO-360: Lasso upload in CLI mode with -Secured option uploads zip.gpg file instead of xml.gpg file.
LASSO-361: Lasso collection fails in CLI mode, for Power Connect switch, when configured with username and
enable password.
LASSO-363: Lasso should collect and parse network attribute “TCPAckFrequency” for EqualLogic attached windows
host.
LASSO-365: Lasso validation fails for Windows host when the user chooses VMware host and selects the option “Use
the username and password as a default”.
LASSO-367: Lasso fails to upload to the FTP site though it gives the message as uploaded successfully.
LASSO-368: Lasso does not package for attached hosts collection, when VMware HITkit is part of the collection.
LASSO-369: Lasso needs to collect more commands on powerconnect B series and PowerConnect M8428-k.
LASSO-370: EQL attribute "Lldp Remote System Description" shows -1 in HTML.
LASSO-372: Lasso collection using password input stream CLI mode fails when existing customer configuration XML
file is loaded.
LASSO-373: Show/Hide buttons does not work for VLANs and Lasso does not parse Switch name for PC Ethernet
switches.
LASSO-374: Inter Array ping test data is not tokenized.
LASSO-376: Lasso does not create output HTML report for M1000e chassis in Win 2k3 server.
LASSO-378: A new switch type "
Brocade Ethernet
" should be added in GUI for collection and parsing the data for
Brocade B8000 switches.
LASSO-379: In Lasso UI, Company Information screen should read “
Enable Report Filtering
” caption instead of
“
Enable Sensitive data Filtering
”. The message box title should display “
Report Filtering
” instead of “
Secure
Site
”.
LASSO-380: For VMware 5.0 Host, iSCSI HBA attributes should display “
Not Available
” instead of “
Not Applicable
”
in Lasso output HTML report.
LASSO-381: Authenticated Proxy Support option to display the text fields closer to the checkbox or have
window/border to group these together.
LASSO-383: Brazos displays the IP address along with Hostname in output HTML report.