User's Manual
– show interface
– show interface switchport
– show port-channel
– show mac-address-table
– show spanning-tree brief
– show spanning-tree
– show cee maps
– show vlan fcoe
– show ip interface brief
– show interface switchport
– show lldp statictics
– show port-channel summary
– show mac-address-table count
– show spanning-tree mst brief
– show qos rcv-queue multicast all
– show qos interface all
– show fcoe-map
– fos switchshow
– fos cfgshow
– fos zoneshow
– chassisshow
4. Capture the console output .
NOTE:
On SAN having many PowerConnect B-Series switches, you need to increase the time out value. By
default, time out value for these switches is 12 minutes (in milliseconds). This value (
powerconnectb-
series.timeout
) can be modified in the file ESC.properties located in the Lasso install directory.
Manually Collecting Data For PowerConnect Ethernet And M8428K Device
To collect information for PowerConnect Ethernet manually:
1. Log in to Power Connect Ethernet switch through Telnet.
2. Run the command show tech-support to display CEE information. If the command fails, in the case of older
switch firmware, then run the following commands
– show running
– show vlan
– show spanning-tree
– show interfaces configuration
– show interfaces status
– show interface port-channel
– show system id
– show stack-port
– show storm-control
– show storm-control all
– show system
44