User's Manual

show interface
show interface switchport
show port-channel
show mac-address-table
show spanning-tree brief
show spanning-tree
show cee maps
show vlan fcoe
show ip interface brief
show interface switchport
show lldp statictics
show port-channel summary
show mac-address-table count
show spanning-tree mst brief
show qos rcv-queue multicast all
show qos interface all
show fcoe-map
fos switchshow
fos cfgshow
fos zoneshow
chassisshow
4. Capture the console output .
NOTE:
On SAN having many PowerConnect B-Series switches, you need to increase the time out value. By
default, time out value for these switches is 12 minutes (in milliseconds). This value (
powerconnectb-
series.timeout
) can be modified in the file ESC.properties located in the Lasso install directory.
Manually Collecting Data For PowerConnect Ethernet And M8428K Device
To collect information for PowerConnect Ethernet manually:
1. Log in to Power Connect Ethernet switch through Telnet.
2. Run the command show tech-support to display CEE information. If the command fails, in the case of older
switch firmware, then run the following commands
show running
show vlan
show spanning-tree
show interfaces configuration
show interfaces status
show interface port-channel
show system id
show stack-port
show storm-control
show storm-control all
show system
44