Owner's Manual
Resolution
Use the full screen mode or increase the resolution.
Issue 6
Description
Lasso's "
auto-discover
" feature works only for EMC CLARiiON arrays and not for hosts attached to Celerra, EqualLogic, and
PowerVault MD Arrays.
Resolution
For those arrays, enter the name or IP address of each attached host.
Issue 7
Description
spcollect command is not supported on EMC Arrays having FLARE less than R13.
Resolution
Run the command "getall".
NOTE
: This command provides less information.
Issue 8
Description
When Lasso is run from a Windows 7, Windows Vista, Windows Server 2008, or Windows Server 2008 R2, if the User Access
Control (UAC) is activated, the MD Series data collection
is not successful.
Resolution
Make sure the User Access Control (UAC) is deactivated.
Issue 9 (LASSO-303)
Description
Revalidate button should be disabled when user clicks on Edit button for any device added previously.
Resolution
Do not click on revalidate button while editing the device details.
Issue 10 (Lasso- 263)
Description
Lasso fails to create collection package, when MD Series is the device in collection and the collection is done on the
Windows 7 system.