– show interfaces traffic-class-group
– show interfaces priority-flow-control
– show interfaces tengigabitethernet <InterfaceName> priority-flow-
control
– show interfaces counters tengigabitethernet <InterfaceName>
– show lldp tlv-select interface tengigabitethernet <InterfaceName>
– show lldp interface tengigabitethernet <InterfaceName>
– show lldp dcbx interface tengigabitethernet <Interface Name> detail
3. Capture the console output
NOTE: On SAN having many PowerConnect Ethernet switches, you may need to increase the time out value.
By default, time out value for these switches is 3 minutes (in milliseconds). This value
(
powerconnectethernet.timeout
) can be modified in the file ESC.properties located in the Lasso install
directory.
Manually Collecting Data For Force 10 Switches
To collect information for Force 10 switches manually:
1. Log in to Force 10 switch through SSH/Telnet.
2. Run the following commands:
– show running
– show vlan
– show spanning-tree 0 brief
– show spanning-tree msti
– show spanning-tree pvst
– show spanning-tree rstp brief
– show interfaces
– show interfaces status
– show interface port-channel
– show system
– show system stack-ports
– show storm-control unknown-unicast
– show storm-control broadcast
– show storm-control multicast
– show interfaces | grep "GigabitEthernet |Flowcontrol"
– show version
– show arp
–
show mac-address-table
–
show environment
–
show inventory
–
show vlan brief
–
show dcb
–
show iscsi
–
show interfaces dcbx
50