Release Notes Lasso Lasso is a Java-based utility that automates the collection of logs and configuration from servers, disk arrays (EqualLogic, PowerVault MD-Series, and EMC), Fibre Channel switches (Brocade, McData, and Cisco), Ethernet and FCoE switches (PowerConnect, Cisco, Brocade, and Force 10), Enclosures (Dell M1000e Chassis, Dell VRTX Chassis) and Management and Monitoring software.
Compellent FluidFS NAS NAS - FS8600 Windows Operating Systems: Windows Server 2003 Standard, Enterprise, and Datacenter Editions Windows Server 2003 R2 Standard and Enterprise Editions Windows Server 2003 x64 Standard, Enterprise, and Datacenter Editions Windows Server 2003 x64 R2 Standard and Enterprise Edition Windows Server 2008 R2 Standard, Enterprise, and Datacenter Windows Server 2008 x64 Standard, Enterprise, and Datacenter Windows Server 2008 x86 Standard, Enterprise
Dell Networking N4032F Dell Networking N2024, N2024P, N2048, and N2048P Dell Networking N3024, N3024P, N3024F, N3048 and N3048P Dell Networking Z9500 Cisco 2960 Cisco 4948 Cisco 3750E/3750X Cisco CBS 3130 Cisco CBS 3030 Cisco Catalyst 3750E Cisco Nexus 5020/7000/5548 Dell Force10 S25P/S50/S60/S4810/S4820T/S6000/S5000 Dell Force10 MXL 10/40GbE Dell Force10 C150/C300/E300(TeraScale)/E600i(ExaScale)/E1200i(ExaScale)/Z9000 Brocade 8000 Encl
o Edit the registry on the remote host using the Windows 2008 Configuration registry script provided in the help file. o Under HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\WindowsCurrentVersion\Policies\system\key, add DWORD value ‘LocalAccountTokenFilterPolicy' and set the value data to 1 and reboot the system. Enable "admin$" and "c$" share to run remote commands. Make sure that adequate disk space is available to temporarily store all event logs and other system data. The program xCmd.
iSCSI HBA: o Adapter Details o SAN Statistics o Network Portals o Physical Network Portals o Logical Network Portals o SAN iSCSI o VAAI Status FC HBA o Storage Adapters o Storage FC Adapters o Storage Core Devices o Storage File Systems Support to collect and parse Device ID, Vendor ID, Subdevice ID, and Subvendor ID for Network Interface Card (NIC), Converged Network Adapter (CNA) and HBA connected to Dell SAN and Networks on Windows.
To collect from EMC, use a system that is not a Fibre Channel attached host. To collect from EqualLogic, install Lasso on one of the iSCSI hosts. For ESX/ESXi, the normal or sudo user should have PasswordAuthentication or Keyboard interactive authentication enabled. For ESX/ESXi, the root user should have permitrootlogin enabled and the PasswordAuthentication or Keyboard interactive authentication should be enabled.
Move the customer configuration file or use "Load a configuration file" option from Lasso Welcome page to use an existing customer configuration file. Versions/Systems Affected None Issue 3: Description Lasso's "auto-discover" feature works only for EMC CLARiiON arrays and not for hosts attached to Celerra, EqualLogic, and PowerVault MD Arrays. Resolution For those arrays, enter the name or IP address of each attached host.
Versions/Systems Affected None Issue 8 (Lasso-277): Description For CLARiiON array, fabrics information is not parsed in output HTML report. Resolution Refer to raw data collection for fabrics information. Versions/Systems Affected None Issue 9 (Lasso-557): Description Edit option should be disabled, when the CLARiiON attached windows hosts are validated with cache credentials. Resolution Do not click on the Edit option, since the status displays that the credentials are already validated.
Lasso Version 4.7 and later Issue 13: Description Lasso collection will not fail and "Collection Successful" message is displayed in Lasso GUI for SAN HQ collection if there are no equallogic devices added to SANHQ. Resolution Equallogic devices must be added to the SANHQ software. Versions/Systems Affected Lasso Version 4.4 and later Issue 14: Description Lasso collection fails to parse QLogic FC HBA "Device ID" information in some Linux host. Resolution None Versions/Systems Affected Lasso Version 4.
None Issue 3: Description Powerpath must be installed on the remote Windows host to get LUN mapping information in the XML and HTML format of the collection. Resolution None Versions/Systems Affected None Issue 4: Description Lasso cannot be installed in folder names having special characters.
Issue 8: Description Lasso cannot validate the Cisco Ethernet Switches if SSH-1 protocol is enabled on the switch. Lasso supports SSH-2 protocol. Resolution None Versions/Systems Affected None Issue 9 (Lasso-191): Description On Force10 devices, the "Show running" command fails to run in model s50v. Resolution None Versions/Systems Affected Lasso 4.4 Issue 10 (Lasso-587): Description Lasso Collects data for MDSeries device only when run as Administrator.
Resolution None Versions/Systems Affected Lasso 4.6 Issue 14 (Lasso-2919): Description You cannot enter the cluster IP address to Lasso to collect on any systems running on Windows. Resolution Node IP should be given to collect the data from Lasso. Versions/Systems Affected Lasso 4.6 Issue 15: Description VRTX Integrated server collections might not work if lasso is installed in any windows virtual machine. Resolution Install Lasso in a physical server and then collect VRTX integrated server information.
Dell provides several online and telephone-based support and service options. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer service issues: 1. 2. 3. 4. Visit www.dell.com/support. Select your support category. Verify your country or region in the Choose a Country/Region drop-down menu at the top of page. Select the appropriate service or support link based on your need.