Owner's Manual

Versions/Systems Affected
None
Issue 8 (Lasso-277):
Description
For CLARiiON array, fabrics information is not parsed in output HTML report.
Resolution
Refer to raw data collection for fabrics information.
Versions/Systems Affected
None
Issue 9 (Lasso-557):
Description
Edit option should be disabled, when the CLARiiON attached windows hosts are validated with cache
credentials.
Resolution
Do not click on the Edit option, since the status displays that the credentials are already validated.
Versions/Systems Affected
None
Issue 10 (Lasso-1593):
Description
Lasso collection is unsuccessful on some windows hosts and expects WMI service to be manually
restarted.
Resolution
Windows Management Instrumentation (WMI) service needs to be re-started manually.
Versions/Systems Affected
Lasso Version 4.5 and later
Issue 11 (Lasso-3037):
Description
Lasso will not parse complete switch port information on which NPIV (Node Port ID Virtualization) is
configured for FC switches.
Resolution
The switch port information is available in the collection text file under the "nsshow -r" command.
Versions/Systems Affected
Lasso Version 4.4 and later
Issue 12:
Description
Lasso collection may run out of space on an ESXi server installed on the SD Card.
Resolution
Required 60 to 100 MB of space in /tmp folder of the host.
Versions/Systems Affected