EXAMPLE:
wsman enumerate http://schemas.dmtf.org/wbem/wscim/1/cim-schema/2/root/dcim/DCIM_BIOSString
-h $IPADDRESS -V -v -c dummy.cert -P 443
-u $USERNAME -p $PASSWORD -j utf-8 -y basic
OUTPUT:
<n1:DCIM_BIOSString>
<n1:AttributeName>UserLcdStr</n1:AttributeName>
<n1:CurrentValue xsi:nil="true"/>
<n1:DefaultValue xsi:nil="true"/>
<n1:FQDD>BIOS.Setup.1-1</n1:FQDD>
<n1:InstanceID>BIOS.Setup.1-1:UserLcdStr</n1:InstanceID>
<n1:IsReadOnly>false</n1:IsReadOnly>
<n1:MaxLength>62</n1:MaxLength>
<n1:MinLength>0</n1:MinLength>
<n1:PendingValue xsi:nil="true"/>
</n1:DCIM_BIOSString>
<n1:DCIM_BIOSString>
<n1:AttributeName>AssetTag</n1:AttributeName>
<n1:CurrentValue xsi:nil="true"/>
<n1:DefaultValue xsi:nil="true"/>
<n1:FQDD>BIOS.Setup.1-1</n1:FQDD>
<n1:InstanceID>BIOS.Setup.1-1:AssetTag</n1:InstanceID>
<n1:IsReadOnly>false</n1:IsReadOnly>
<n1:MaxLength>10</n1:MaxLength>
<n1:MinLength>0</n1:MinLength>
<n1:PendingValue xsi:nil="true"/>
</n1:DCIM_BIOSString>
.
.
.
17.7 Applying the Pending Values for BIOS & Boot-CreateTargetedConfigJob()
This method is called to apply the pending values created by the SetAttribute(), SetAttributes(),
ChangeBootOrderByInstanceID(), and ChangeBootSourceState() methods. The system will
automatically reboot depending on the ScheduledStartTime selected. Using the
CreateTargetedConfigJob() jobID output with the job control section can be used to obtain its status.
Invoke CreateTargetedConfigJob() with the following parameters and syntax:
TARGET: This Parameter is the FQDD of the BIOSAttribute instances, obtained from the
InstanceID field in Section 17.1
RebootJobType: There are three options for rebooting the system.