Owner's Manual
Fabric OS v6.3.1_dcb5 for DELL M8428-k Release Notes 1.0 Draft Page 12 of 23
Other Important Notes and Recommendations
Configuration Notes:
1) Sometimes fcoeport may not login on the switch shipped out of factory; please follow the
following procedure from the cmsh to bring the fcoeport online. This needs to be done only
for the first time switch is brought up.
• no fcoeport
• fcoeport
• shut
• no shut
2) DELL M8428-k supports 128 sflow samples per second for IP connections. To avoid dropped
samples ensure that the aggregated sflow samples do not exceed this value.
Documentation Updates
For Fabric OS v6.3.1_dcb5 documentation refer to Fabric OS v6.3.1 documentation. When
using the FOS v6.3.1 documentation, the DELL M8428-k Switch Module is equivalent to the
BROCADE 8000 except where noted in this section. The most recent Fabric OS v6.3.1
documentation manuals are available on MyBrocade:
http://my.brocade.com/
The following three documents are intended specifically for DELL M8428-k:
1) Dell Converged Enhanced Ethernet Command Reference
for FOS v6.3.1_dcb (53-1002115-01)
2) Dell Converged Enhanced Ethernet Administrator's Guide
for FOS v6.3.1_dcb (53-1002116-01)
3) Dell Fabric OS MIB Reference Manual
for FOS v6.3.1_dcb (53-1002117-01)
The above documents supersede the FOS standard documentation.
In addition,please note the following updates to the standard FOS v6.3.1 documentation.
Brocade Fabric OS Administrator’s Guide (Publication Number 53-1001336-
02)
On Table 90 – Buffer Credits
Add the Brocade M8428-k model with the following table information
Switch/blade
model
Total FC Ports
(per switch blade)
User Port Group Size
Unreserved Buffers
(per port group)
M8428-k
4
4
580