White Papers

vStart 50 Solution Overview
Dell Inc. 12
6.3 Out-of-band management
Out-of-band (OOB) management is available for the PowerEdge R620 servers with the Hyper-V role
enabled through the iDRAC7 Enterprise. The optional PowerEdge R420 management server uses the
iDRAC7 Enterprise, which allows the PowerEdge R420 server to be remotely managed as needed.
iDRAC Enterprise features include:
Remote systems management and monitoring
Console redirection for remote system KVM (keyboard, video, mouse) functionality
Virtual media that enables server access to local media drives on a management station
Access to system logs
Platform events and alerts that warn of potential problems by e-mail or simple network
management protocol (SNMP) traps
Remote power management functionality
For more information, see the Embedded Server Management web site.
EqualLogic SAN OOB management is available via the dedicated management ports on each EqualLogic
PS6100 array storage controller. The PowerConnect 7024 switches provide a dedicated OOB port. The
PowerConnect 6224 switches are managed in-band from the PowerEdge R420 Management Server.
7 Power, Cooling, and Weight Requirements
This section provides power, cooling, and weight requirements for the solution. Power values provided
in the table are estimated maximum power values for the solution based on Dell Labs measurements.
Actual power, cooling, and weight will vary based on configuration, workload, and Data Center
Environment. PDUs and UPS(s) utilized in this paper are specifically for the solution available in the
USA. Consult with your Dell Sales and Services representatives for further details.
Table 4. vStart 50 Power, Cooling, and Weight Requirements
Solutions
Power
(max watts)
Cooling
(BTU/hr)
Weight (kg)
vStart 50
no UPS
2414
8237
240
with R3750 UPS
2789
9516
305
vStart 50+
no UPS
3114
10625
272
with R3750 UPS
3489
11905
338