10
Port
Number
Protocols
Port Type
Maximum
Encryption
Level
Direction
Usage
Configurable
51
IMP
UDP/TCP
None
N/A
IMP Logical
Address
Maintenance
No
5353
mDNS
UDP/TCP
All
Multicast DNS
No
631
IPP
UDP/TCP
None
Out
Internet Printing
Protocol (IPP)
No
69
TFTP
UDP
128-bit
All
Trivial File
Transfer
No
111
NFS
UDP/TCP
128-bit
In
SUN Remote
Procedure Call
(Portmap)
No
68
BOOTP
UDP
None
Out
Bootstrap
Protocol Client
No
User notes
Dell Management Plug-in for VMware vCenter only supports BIOS mode to auto-deploy
hypervisor on the target server. Make sure that you have BIOS mode selected in the reference
hardware profile prior to applying the Hypervisor profile. If there is no hardware profile
selected, then make sure to manually configure the boot mode as BIOS and reboot the server
prior to applying the hypervisor profile.
After the deployment of ESXi finishes, the server shows a purple screen as shown below with
the error “Two file systems with the same UUID have been detected. Make sure you do not
have two ESXi installations.”