Release Notes

Issue30:
Single DUP update continues without using the Apply Update selection method.
Description:Whenyoudon’tselectanoptiononthelastpageofthefirmwareupdateusingtheSingle
FirmwareUpdatemethod,thedefaultbehaviorisappliedtheupdateonnextreboot.
Resolution:Ifthissituationhappens,managetherebootofthehosttogettheselectedupdatetoreply.To
avoidthissituation,alwaysmaketheselectionontherebootpagepriortoproceedingwiththefirmware
update.
VersionsAffected:1.0,1.0.1
Issue31:
Deployment failed by exception of parallel processing conflicts when updating.
Description:BIOSconfigurationcanfailonthehardwareconfigurationduringdeployment.
Resolution:Don’tselectBIOSduringdeployment.
VersionsAffected:1.0,1.0.1
Issue32:
ESXi deployment fails to configure the correct LOM interface.
Description:IfyouhavemultipleMACaddressesthatarenotinteamingmode,andtaketheMACaddress
thatisnotwiredforusebytheDellManagementPlugin,thenDHCPfails.
Resolution:UseLOM1asyourManagementNICandmakesureyouhaveDHCPonyournetwork.
Versions
Affected:1.0,1.0.1
Issue33: Dell Management Plug-in fails to forward events to vCenter.
Description:Ifyouhavenotmadeanychangestothedefaultalertsettings,andifyoudonotfollowevery
stepoftheupgradeinstructionsto1.0.1(seeUserGuideforthestepbystepinstructiononhowto
upgradefrom1.0to1.0.1)thenthenewappliancewon’tsendalertstoanyvCenterthatregisteredwith
theupgradedappliance.
Resolution:Youmustresettheupgradedappliancebacktofactorydefaults.Thiswillfixthisissue,butyou
willalsoloseallthesettingsandprofilesyoucreatedwhenusingDellManagementPlugin1.0.Makesure
youfollowthe
UserGuidewhenupgradingfrom1.0to1.0.1toavoidthisissue.
VersionsAffected:1.0.1
