Release Notes
Issue6:Readonlyattributesblank
Description:PossiblevaluesforthereadonlyattributesareblankinLifecycleControllerRemoteServices
1.4.
Resolution:None
VersionsAffected:1.0,1.0.1
Issue7:WinRMcommandAssignSparereturnsGeneralFailure.
Description:TheWinRMcommandAssignSparereturnsanoutputofGeneralFailureinLifecycleController
RemoteService1.4.
Resolution:None
VersionsAffected:1.0,1.0.1
Issue8:9
th
and10
th
generationservers’firmwareversions
Description:For9thand10thgenerationservers,BIOS/BMC/DRACfirmwareversionsareviewableonlyat
theClusterViewlevelinvCenterorontheOverviewpageoftheindividualhostview.Firmwareversion
informationisnotactiveintheindividualhostviewunderFirmware,andthatpage
appearsgrayedout.
Resolution:None
VersionsAffected:1.0,1.0.1
Issue9:
The duplication of hardware profiles does not preserve all changes.
Description:Thishappensifyoumakeaduplicationofahardwareprofilethatisdifferentfromtheoriginal.
Resolution:
Ifyounoticethatthechangesmadetoahardwareprofilearen’tbeingpersistent,thentakethefollowing
actions:
Selectthehardwareprofileyouwanttochange,andclickEdit.
OpenEditModeontheareatochange,makechangesandclickSaveORselecttheIncludein
HardwareProfilecheckbox.
Closethedialogbox.
Onthemainpage,RefreshProfiles(shouldhappenautomatically,butifnot,doamanualrefresh).
Toopenthedialogbox
forthenextchange,clickEditagain.