User Guide

The BIOS does not take any action.
Virtual disks partially degraded error message
Error Message:
x Virtual Disk(s) Partially Degraded, where x is the number of
virtual disks partially degraded.
Probable Cause: This message is displayed when the BIOS detects a single disk failure in a RAID 6 or
RAID 60 configuration.
Corrective Action: You must check why the member disk is not present to correct the problem. The
BIOS does not take any action.
Memory or battery problem error message
Error Message:
Memory/Battery problems were detected. The adapter has
recovered, but cached data was lost. Press any key to continue.
Probable Cause: The message occurs under the following conditions:
The adapter detects data in the controller cache that has not yet been written
to the disk subsystem.
The controller detects an Error-Correcting Code (ECC) error while performing
its cache checking routine during initialization.
The controller discards the cache rather than sending it to the disk subsystem
because the data integrity cannot be guaranteed.
The battery may be under charged.
Corrective Action: Allow the battery to charge fully to resolve this problem. If the problem persists, the
battery or controller memory may be faulty. Contact Dell Technical Support.
Firmware fault state error message
Error Message:
Firmware is in Fault State.
Corrective Action: Contact Dell Technical Support.
Foreign configuration found error message
Error Message:
Foreign configuration(s) found on adapter. Press any key to
continue, or ’C’ to load the configuration utility or ’F’ to
import foreign configuration(s) and continue.
Probable Cause: When a controller firmware detects a physical disk with existing foreign metadata,
it flags the physical disk as foreign and generates an alert indicating that a foreign
disk was detected.
Corrective Action: Press <F> at this prompt to import the configuration (if all member disks of the
virtual disk are present) without loading the BIOS Configuration Utility (<Ctrl>
<R>). Or press <C> to enter the BIOS Configuration Utility (<Ctrl> <R>) and either
import or clear the foreign configuration.
77