Administrator Guide

Table Of Contents
启用/禁用接收器
使用 set 命令启用或禁用 监视接收器
关于此任务
要禁用监视接收器请执行以下操作
VPlexcli:/monitoring/directors/director-2-1-B/monitors/director-2-1-B_TestMonitor/sinks/
console> set enabled false
VPlexcli:/monitoring/directors/director-2-1-B/monitors/director-2-1-B_TestMonitor/sinks/
console> ll
Name Value
------- -------
enabled false
format table
sink-to console
type console
要启用监视接收器请执行以下操作
VPlexcli:/monitoring/directors/director-2-1-B/monitors/director-2-1-B_TestMonitor/sinks/
console> set enabled true
VPlexcli:/monitoring/directors/director-2-1-B/monitors/director-2-1-B_TestMonitor/sinks/
console> ll
Name Value
------- -------
enabled true
format table
sink-to console
type console
强制执行立即轮询
使用 monitor collect 命令可强制执行立即轮询和收集性能数据而无需等待自动轮询间隔。
例如
VPlexcli:/> monitor collect /monitoring/directors/director-2-1-B/monitors/director-2-1-
B_TestMonitor
Source: director-2-1-B_TestMonitor
Time: 2010-07-01 10:05:55
director.be-ops (counts/s):
.
.
.
端口监视
与脚本 port-stats-monitor 有关的详细信息。
入门
port-stats-monitor 脚本可用于识别正在观察问题的 Metro Node 端口。由于 port-stats-monitor 脚本记录了问题这表明 Metro
Node 系统可能遇到问题也可能没有遇到问题。但是这确实表明 SAN 中存在问题必须加以解决才不致影响 Metro Node
统。这些问题可能特定于 Metro Node也可能不特定于 Metro Node。有时在找到并解决 SAN 问题之前可能需要禁用被该脚本
标识为具有或遇到问题的问题端口。
FC 端口监视脚本具有以下功能
一分钟仅调查一次 Metro Node FC 端口如果检测到可能的结构问题会向配置的电子邮件地址发送电子邮件。
性能和监控
87