Administrator Guide

Table Of Contents
Table 1. Metavolume display fields
Field Description
active
Indicates whether this volume is the currently active metadata volume. The system has
only one active metadata volume at a time.
application-consistent
Whether this storage-volume is application-consistent.
block-count
The number of blocks in the volume.
capacity
The size of the metavolume.
component-count
The number of mirrors in the RAID 1 metadata volume.
free-slots
The number of free slots for storage-volume headers in this metavolume.
geometry
Indicates the geometry or redundancy of the device. Always RAID 1.
health-indications
If health-state is not ok, additional information.
health-state
ok - The storage volume is functioning normally.
degraded - The storage volume may be out-of-date compared to its mirror. (This
state applies only to a storage volume that is part of a RAID 1 metadata volume.)
unknown - Metro node cannot determine the health state of the storage volume, or
the state is invalid.
non-recoverable error - The storage volume may be out-of-date compared to
its mirror (applies only to a storage volume that is part of a RAID 1 metadata volume),
and/or metro node cannot determine the health state.
critical failure - Metro node has marked the storage volume as hardware-dead.
locality
Locality of the supporting device.
local - The volume is local to the enclosing cluster.
remote - The volume is made available for a different cluster than the enclosing
cluster, and is accessed remotely.
distributed - The virtual volume either has legs, or is capable of having legs at
more than one cluster.
operational status
ok - The storage volume is functioning normally.
degraded - The storage volume may be out-of-date compared to its mirror. (This
state applies only to a storage volume that is part of a RAID 1 metadata volume.)
unknown - Metro node cannot determine the health state of the storage volume, or
the state is invalid.
error - Metro node has marked the storage volume as hardware-dead.
starting - The storage volume is not yet ready.
lost-communication - The storage volume is unreachable.
ready
Indicates whether this metadata volume is ready or not.
rebuild-allowed
Whether the device is allowed to rebuild.
rebuild-eta
If a rebuild is in progress, the estimated time remaining for the current rebuild to complete.
rebuild-progress
If a rebuild is in progress, the percentage of the device that has been rebuilt.
rebuild-status
The rebuild status of the device. done - Rebuild is complete.
rebuild-type
The rebuild type.
full - A full copy of all the blocks. A metavolume rebuild is always full.
incremental - An incremental copy uses a checksum differencing algorithm to
transfer only those blocks that are different.
comparison - A comparison copy.
resync - A resync rewrites blocks affected by a director failure, guaranteeing that the
mirror legs are identical.
slots
The total number of slots for storage-volume headers in the metavolume.
stripe-depth
The depth of a stripe in bytes when geometry is RAID-0.
Meta Volumes 13