CLI Guide

Table Of Contents
node mirror leg. After resolving the underlying issue that lead to an out of space error, use this command to resume I/O for
supporting storage-volumes that have been marked dead. The target devices may be of any geometry, local or distributed.
This command executes storage-volume resurrect for all dead-storage-volumes of a device. This scenario should only
happen on an XtremIO storage volume that is used as a metro node mirror leg.
director commission
Starts the directors participation in the cluster.
Contexts
All contexts.
In /clusters/cluster/directors context, command is commission.
Syntax
director commission
[-n|--director] director
[-t|--timeout] seconds
[-a|--apply-cluster-settings]
[-f|--force]
Arguments
Required arguments
[-n|--director] director * The director to be commissioned.
Optional arguments
[-f|--force] Commission the director regardless of firmware version mismatch.
--timeout seconds The maximum time to wait for --apply-cluster-settings operations to complete, in
seconds.
Default: 60 seconds.
0: No timeout.
[a|--apply-cluster-
settings]
Add this director to a running cluster and apply any cluster-specific settings. Use this
argument when adding or replacing a director in an existing metro node.
* - argument is positional.
Description
In order to participate in a cluster, a director must be explicitly commissioned. Uncommissioned directors can boot but do not
participate in any cluster activities.
Use the version -a command to display the firmware version for all directors in the cluster.
The director commission command fails if the director's firmware version is different than the already commissioned
directors, unless the --force argument is used.
Commands
127