CLI Guide

Table Of Contents
underlying-storage-block-size 512
use used
used-by [extent_test01_1]
vendor-specific-name DGC
vias-based false
Enable and display iSCSI FE and BE ports:
VPlexcli:/clusters/cluster-1/directors/director-1-1-A/hardware/ports> ll
Name Address Role Port Status
----- -------------- --------- -----------
ETH02 128.221.252.97 local-com up
ETH03 128.221.253.97 local-com up
ETH04 192.168.11.35 wan-com up
ETH05 10.6.11.35 wan-com up
ETH06 192.168.71.58 front-end up
ETH07 192.168.91.58 front-end up
ETH08 192.168.50.58 back-end up
ETH09 192.168.152.58 back-end up
Enable and display ports:
VPlexcli:/clusters/cluster-1/directors/director-1-1-A/hardware/ports> ll
Name Address Role Port Status
------- ------------------ --------- -----------
A0-FC00 0x5000144260006e00 front-end no-link
A0-FC01 0x5000144260006e01 front-end up
A0-FC02 0x5000144260006e02 front-end up
A0-FC03 0x0000000000000000 front-end down
A1-FC00 0x5000144260006e10 back-end up
A1-FC01 0x5000144260006e11 back-end up
A1-FC02 0x5000144260006e12 back-end no-link
A1-FC03 0x5000144260006e13 back-end no-link
A2-FC00 0x5000144260006e20 wan-com up
A2-FC01 0x5000144260006e21 wan-com up
A2-FC02 0x5000144260006e22 wan-com no-link
A2-FC03 0x5000144260006e23 wan-com no-link
A3-FC00 0x5000144260006e30 local-com up
A3-FC01 0x5000144260006e31 local-com up
A3-FC02 0x0000000000000000 - down
A3-FC03 0x0000000000000000 - down
VPlexcli:/clusters/cluster-1/directors/director-1-1-A/hardware/ports> set A0-
FC03::enabled true
VPlexcli:/clusters/cluster-1/directors/director-1-1-A/hardware/ports> ll
Name Address Role Port Status
------- ------------------ --------- -----------
A0-FC00 0x5000144260006e00 front-end no-link
A0-FC01 0x5000144260006e01 front-end up
A0-FC02 0x5000144260006e02 front-end up
A0-FC03 0x5000144260006e03 front-end no-link
A1-FC00 0x5000144260006e10 back-end up
A1-FC01 0x5000144260006e11 back-end up
A1-FC02 0x5000144260006e12 back-end no-link
A1-FC03 0x5000144260006e13 back-end no-link
A2-FC00 0x5000144260006e20 wan-com up
A2-FC01 0x5000144260006e21 wan-com up
A2-FC02 0x5000144260006e22 wan-com no-link
A2-FC03 0x5000144260006e23 wan-com no-link
A3-FC00 0x5000144260006e30 local-com up
A3-FC01 0x5000144260006e31 local-com up
A3-FC02 0x0000000000000000 - down
A3-FC03 0x0000000000000000 - down
Change and display the name of a virtual volume:
NOTE:
Changing a virtual volume name will not cause any impact to host I/O.
VPlexcli:/clusters/cluster-1/virtual-volumes/EMC-CLARiiON-0075-VNX-LUN122_1_vol>set
-a name -v new_name
VPlexcli:/clusters/cluster-1/virtual-volumes/new_name> ll
Name Value
------------------ -----------------------------------------------
Commands 277