CLI Guide

Table Of Contents
/clusters/cluster-1/virtual-volumes/myVolume:
Name Value
-------------------------- ----------------------------------------
block-count 2621440
block-size 4K
cache-mode synchronous
capacity 10G
consistency-group -
expandable true
expandable-capacity 0B
expansion-method storage-volume
expansion-status -
health-indications []
health-state ok
locality local
operational-status ok
recoverpoint-protection-at []
recoverpoint-usage -
scsi-release-delay 0
service-status unexported
storage-tier -
supporting-device device_myVolume_c1
system-id myVolume
thin-capable true
thin-enabled true
volume-type virtual-volume
vpd-id VPD83T3:6000144000000010e018b6fbc02ab396
VPlexcli:/clusters/cluster-1/virtual-volumes>
Example
Create a virtual volume with RAID 1 local devices and specified storage volumes:
VPlexcli:/> storage-tool compose --name TEST --geometry raid-1 --storage-volumes
VPD83T3:60060160cea33000fc39e04dac48e211, VPD83T3:60060160cea33000fb9c532eac48e211,
VPD83T3:600601605a903000f2a9692fa548e211, VPD83T3:600601605a903000f3a9692fa548e211
See also
storage-volume unclaim
storage-volume auto-unbanish-interval
Displays or changes auto-unbanish interval on a single director.
Contexts
All contexts.
In /clusters/cluster/storage-elements/storage-volumes context, command is auto-unbanish-interval.
Syntax
storage-volume auto-unbanish-interval
[-n|--director] path
[-i|--interval] [seconds]
Commands
287