Reference Guide

Condition
ID
Severity Call home Alert name Descriptio
n
RCA Corrective
action
Event
source
Alert type
cluster is
doing I/O to
the storage
volume,
data
corruption is
likely.
the other
cluster. 3.
Remove
visibility to
the storage
volume from
the other
cluster.
0x30010 WARNING True Mirror
Marked Out
Of Date
A mirror of a
RAID 1
device has
been
marked fully
out of date.
A write to a
RAID 1
device is
successful
to some
mirrors, tat
mirror is
being
marked as
fully out of
date, so
that a
subsequent
rebuild can
bring the
mirror back
up to date.
If the mirror
is not still
showing as
out of date,
it has likely
auto
corrected. If
it is still
marked out
of date,
investigate
the back-
end issues.
Once those
issues are
resolved,
the rebuild
initiates
automaticall
y. It can
take time
depending
on the
number of
active
rebuilds on
the system
at the time.
Contact Dell
Customer
Support if
the
condition
persists.
METAVOLU
ME
Operational
0x30011 CRITICAL True Metadata
Volume
Write Failed
A write to a
metadata
volume is
unsuccessfu
l.
A write to
the
specified
metadata
volume is
failed. The
changes are
preserved in
memory, but
if the entire
cluster fails
or is shut
down before
the access
to the
metadata
volume is
restored
1. Fix the
unhealthy or
failed
metadata
volume, or
underlying
storage
volumes
through
checking
fabric
connectivity
and one or
more
storage
arrays. 2. If
the
metadata
METAVOLU
ME
Operational
Events and Alerts 27