Reference Guide

Condition
ID
Severity Call home Alert name Descriptio
n
RCA Corrective
action
Event
source
Alert type
device has
been
isolated due
to severe
performanc
e
degradation
of its
storage
volume
components
.
volumes
supporting
this mirror
are
performing
poorly,
causing
severe
degradation
in the
RAID-1
performanc
e. To
improve the
RAID-1
performanc
e through
the healthy
legs, the IOs
to the
poorly
performing
mirror leg
have been
blocked.
poor
performanc
e of storage
volume
through
seeing the
troubleshoo
ting entry
related to
degraded
disks and
isolated
mirrors in
the normal
operation
section of
SolVe
Procedure
Generator
("Recovery
->
Troubleshoo
ting ->
Problems
during
normal
operation ->
Degraded
disks and
isolated
mirrors
problems").
If the
underlying
issues
cannot be
fixed in a
timely
manner,
consider
detaching
the
unhealthy
mirror from
the RAID-1
device and
attaching a
mirror based
on healthy
storage
volumes to
reinstate
redundancy.
Contact Dell
Customer
Support if
the problem
persists.
0x3001d
INFO False Metadata
Copy
Succeeded
Successfully
copied in-
memory
All in-
memory
metadata
It is an
informationa
l event only.
METAVOLU
ME
Operational
34 Events and Alerts