Reference Guide

Condition
ID
Severity Call home Alert name Descriptio
n
RCA Corrective
action
Event
source
Alert type
Support if
problem
persists.
0x90002 CRITICAL True Possible
Stuck I/O
detected on
virtual
volume
Possible
Stuck I/O
detected on
virtual
volume.
An I/O
failed to
complete or
be properly
aborted and
cleaned up.
Contact Dell
Customer
Support for
assistance.
VIRTUALVO
LUME
Operational
0x90003 ERROR True Unmap
Command
Buffer
Allocation
Failed
SCSI
UNMAP
command
failed on
virtual
volume due
to an
internal
memory
allocation
issue.
A Scsi
Unmap
command
could not be
processed
because of
an internal
firmware
memory
allocation
failure.
Run the
collect-
diagnostics
utility to
collect
system
information
to
determine
why an
internal
firmware
memory
allocation
failure is
occurred.
Contact Dell
Customer
Support.
VIRTUALVO
LUME
Operational
0x90004 ERROR True SCSI
Compare
And Write
command
that is failed
on virtual
volume due
to an
internal
memory
allocation
issue
SCSI
Compare
And Write
command
that is failed
on virtual
volume due
to an
internal
memory
allocation
issue.
The metro
node
director had
insufficient
memory
resources to
process the
SCSI
Compare
and Write
Command.
Run collect-
diagnostics
utility to
collect
system
information
to
determine
why an
internal
firmware
memory
allocation
failure is
occurred.
Contact Dell
Customer
Support.
VIRTUALVO
LUME
Operational
0x90005 ERROR True SCSI Write
Same (16)
command
failed on
virtual
volume due
to an
internal
memory
allocation
issue
SCSI Write
Same (16)
command
failed on
virtual
volume due
to an
internal
memory
allocation
issue.
The metro
node
director had
insufficient
memory
resources to
process the
SCSI Write
Same
Command.
Run the
collect-
diagnostics
utility to
collect
system
information
to
determine
why an
internal
firmware
memory
VIRTUALVO
LUME
Operational
38 Events and Alerts