Reference Guide

Condition
ID
Severity Call home Alert name Descriptio
n
RCA Corrective
action
Event
source
Alert type
view is
disabled
view is
disabled.
true. Refer
to the
metro node
CLI guide.
0x9000d WARNING True Failed to
process a
Write Same
(16)
command
on volume
as write-
same-16-
enabled
attribute is
disabled on
the storage
view
Failed to
process a
Write Same
(16)
command
on volume
as write-
same-16-
enabled
attribute is
disabled on
the storage
view.
Scsi Write
Same
command
processing
is disabled
on metro
node.
Use the CLI
command
and set the
write-
same-16-
enabled
attribute for
the
correspondi
ng storage
view to
true. Refer
to the
metro node
CLI guide.
STORAGEVI
EW
Operational
0x9000e WARNING True Unintention
al Front End
Port Link
Down
Unintention
al Link
Down seen
for Front
End Target
Port.
An enabled
FE port has
gone down
as a result
of FC cable
pull, switch
reboot or
disabling
switch port.
1. Check the
FE port
status in the
'ports'
context of
VPlexcli /
clusters/
cluster-*/
directors/
**/ports/
to verify if
it's still in
'no-link'
state. If it is,
proceed to
next steps.
2. Check
the switch
and ensure
it's
operational,
check the
switch logs
for errors
that will
indicate the
root cause
of the issue.
3. Check
the cabling
and SFPs
along the
path, clean/
reset/
replace as
needed.
TARGETPO
RT
Operational
0xb0001 WARNING True Recovery
From One
Director
Failure Took
Too Long
Recovery
from the
failure of a
single
director
Recovery
from the
failure of a
single
director
If the host
application
experienced
a DU,
confirm that
SYSTEM Operational
Events and Alerts 41