Reference Guide
Table Of Contents
- Dell EMC Storage Systems Events and Alerts Guide for the metro node appliance
- Contents
- Events and Alerts
- UI overview
- Platform alerts
- Hardware alerts
- Alert states
- Scope of the events
- Sorting and filtering alerts
- Download .csv
- Default and hidden columns
- Live alerts
- Alerts roll-up
- Historical alerts
- Alerts on remote director
- Configure alerts
- Service Monitoring Alert
- Test alerts for platform, monitor, and SMS
- Heartbeat alerts
- Mail notification
- Configure emailing notification
- Test email alert
- Supported events
Condition
ID
Severity Call home Alert name Descriptio
n
RCA Corrective
action
Event
source
Alert type
booting,
thereby
preventing
it from
processing
I/O
0x120003 CRITICAL True A
communicat
ions path
has been
disconnecte
d
A
communicat
ions path
has been
disconnecte
d.
A
communicat
ions path
has been
disconnecte
d due to
network
connectivity
issues.
Check the
WAN COM
or LOCAL
COM path
that was
disconnecte
d, then
check the
switch logs
for errors
that will
help
pinpoint the
root cause.
If errors
point to
hardware
issue
check/
clean/
replace the
cables and
SFPs along
the path.
Engage Dell
Customer
Support if
unable to
determine
the root
cause.
COMMUNIC
ATIONSPAT
H
Operational
0x150008 ERROR True A Fibre
Channel
port came
online, but is
unzoned.
A Fibre
Channel
port came
online, but is
unzoned.
Fibre
Channel
port is
connected
to a switch,
but the port
isn't in any
zone yet.
Please
verify: 1.
That the
port is
cabled
correctly. 2.
That the
switch
zoning is
complete
and correct.
Additionally,
some
switches
need to
enable the
zoning
configuratio
n one more
time to
make the
just-
changed
VIRTUALPO
RT
Operational
Events and Alerts 45