Reference Guide

Condition
ID
Severity Call home Alert name Descriptio
n
RCA Corrective
action
Event
source
Alert type
0x1701f5 WARNING True Login High
I/O Error
Rate
{vportName
}: In the last
{seconds}
seconds
{errorPerce
nt}% of I/O
failed on
login (npid
{npid},
wwpn
{wwpn})
Either there
are frame
drop issues
on the
fabric or
there is an
internal
issue in the
metro node.
Check the
physical
paths to the
switch and
verify good
connectivity
through
reseat/
clean/
replacement
of cables/
SFPs as
needed,
including
the
connectivity
of the metro
node port.
Check the
switch logs
for
indications
of frame
drops or
other
problems. If
unable to
determine
the cause
engage Dell
EMC
Customer
Service.
VirtualPort
Operational
0x190001 ERROR True I/O Busy
Threshold
Reached
The given
storage
volume
reached the
limit for the
number of
consecutive
busy
responses
returned.
The storage
volume
returned
many busy
responses,
and may be
marked
dead in
metro node
as a result,
if the
devices
above have
redundancy.
Engage
array vendor
in
determining
the cause of
the returned
SCSI busies.
If the
storage
volume has
been
marked
dead, it is
automaticall
y
resurrected
by metro
node once
the array
begins
processing
I/O for the
storage
volume
again.
DiskId
Operational
0x180001 ERROR True One Disk
HW After
A storage
volume
Multiple
successive
Verify
reported
DiskId Operational
Events and Alerts 57