imp_info.book Page 2 Monday, March 21, 2011 1:52 PM Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. ____________________ Information in this publication is subject to change without notice. © 2009—2011 Dell Inc. All rights reserved.
imp_info.book Page 3 Monday, March 21, 2011 1:52 PM Contents Overview . . . . . . . . . . . . . . . . . . . . . . . . . . Minimum Supported BIOS, System Firmware, and RAID Controller Driver Versions . . . . . . . . . . Known Issues . . . . . . . . . . . . . . . . . . . . . . . . . . Windows Server 2008 SP2 Installation on iSCSI Offload Fails . . . . . . . . . . . . . . . . . BlueScreen During Setup With Two PERC Controllers . . . . . . . . . . . . . . . . .
imp_info.book Page 4 Monday, March 21, 2011 1:52 PM Dell PowerVault 124T DLT VS160 Autoloader is Not Shown in Device Manager When Connected to the Dell 39320A SCSI Ultra320 Lead Controller Card . . . . . . . . . . . . . . . . 14 Unable to Login to Dell IT Assistant 8.2 on a System Running the Windows Server 2008 SP2 Operating System . . . . . . . . . . . . . . . 15 Windows NT Backup-Restore Utility Fails Intermittently During First Restore Attempt . . . .
imp_info.book Page 5 Monday, March 21, 2011 1:52 PM Firmware Path Cannot be Dragged and Dropped Into the Dell Firmware Update Utility DOS (DFU DOS) Program . . . . . . . . . . . . . . . . . 18 Tape Device Firmware Version is not Updated in the Windows Registry When Device Manager is Scanned . . . . . . . . . . . . . . . . . . . . . 18 Virtual Floppy Drive is Listed as a Target Location for Windows Server Backup Tool . . . . . . . . .
imp_info.book Page 6 Monday, March 21, 2011 1:52 PM Windows Deployment Services (WDS) Server Does Not List the Language String and Build Number of the Operating System Image While Installing Through a Remote Server. . . . . . . . . . . . . . 24 Terminal Services Manager Does Not Reflect Correct Connection Status . . . . . . . . . . . . . 24 I/O Requests are Timed Out If a Reset is Issued in a Multi-Path or Multi-Host Configuration . . . . . .
imp_info.book Page 7 Monday, March 21, 2011 1:52 PM Overview This document provides important information about Microsoft Windows Server 2008 Service Pack 2 (SP2) for Dell PowerEdge systems. CAUTION: To prevent the possibility of viruses infecting your system, it is recommended that you use a different system to download any recommended patches, hotfixes, and service packs from the Microsoft website at microsoft.com.
imp_info.book Page 8 Monday, March 21, 2011 1:52 PM Table 1-1. Minimum Supported BIOS/BMC Versions (continued) Dell PowerEdge (PE) System BIOS/BMC Version PE 1900 2.2.6/A07 or later PE 1950 2.2.6/A11 or later PE 2600 A14/A37 or later PE 2650 A21/A02 or later PE 2800 A06/A09 or later PE 2850 A06/A09 or later PE 2900 2.2.6/A09 or later PE 2950 2.2.6/A10 or later PE 2970 1.5.2/A05 or later PE 6800 A05/A10 or later PE 6850 A05/A10 or later PE 6950 1.4.
imp_info.book Page 9 Monday, March 21, 2011 1:52 PM Table 1-1. Minimum Supported BIOS/BMC Versions (continued) Dell PowerEdge (PE) System BIOS/BMC Version PE R900 1.1.6/A00 or later PE T100 1.1.2 or later PE T105 1.1.1 or later PE T300 1.2.0/A00 or later PE T605 1.2.3/A01 or later PE T610 1.0.4/A00 or later Table 1-2 lists the minimum supported versions of the system firmware and driver for the supported Redundant Array of Independent Disks (RAID) controllers. Table 1-2.
imp_info.book Page 10 Monday, March 21, 2011 1:52 PM Table 1-2. Minimum Supported Versions of System Firmware and RAID Controller Driver (continued) Supported Platforms Minimum Required Firmware Version Minimum Required Driver Version PERC 4/SC and 4/DC 352D or later 6.50.3.xxa or later PERC 4/Di on PE1750 422D A24 or later 6.50.3.xxa or later PERC 4/Di on PE2600 252D A30 or later 6.50.3.xxa or later PERC 4/im on PE1855MC Use the latest 1.09.11 or later PERC 3/Di and PERC 3/Si 2.8.1.
imp_info.book Page 11 Monday, March 21, 2011 1:52 PM Known Issues NOTE: For information on Hyper-V issues, see the Microsoft Hyper-V for Dell PowerEdge Systems Running Microsoft Windows Server 2008 Installation Instructions and Important Information at support.dell.com/manuals. NOTE: The Hyper-V RTM component is available with Windows Server 2008 SP2.
imp_info.book Page 12 Monday, March 21, 2011 1:52 PM NIC Removal Not Updated in msinfo32 Report Dell Ref: 75097 If you stop the NIC process using the Safely Remove Hardware icon in the Task Bar, the changes are not reflected in the Microsoft System Information (msinfo32) report. A manual refresh also does not change the NIC status. This is a known issue with the Windows Server 2008 x86 Edition operating system.
imp_info.book Page 13 Monday, March 21, 2011 1:52 PM The Icons for Removable Storage Media (RSM) Work Queue View Do Not Display Any Details Dell Ref: 147879 If you click on the work queue view for RSM; the large icon view, the small icon view, the details view, and the list view do not display any text describing the icon. This is a known issue with the Windows Server 2008 SP2 operating system.
imp_info.book Page 14 Monday, March 21, 2011 1:52 PM System Information Screen Does Not Provide Network Information in the Windows Server Core Dell Ref: 76977 In Windows Server Core, if you run the systeminfo command for information about the network, it returns a N/A value denoting non availability. The same issue occurs if you run systeminfo in the Windows Server 2008 SP2 operating system full version. This is a known issue of the Windows Server Core.
imp_info.book Page 15 Monday, March 21, 2011 1:52 PM Unable to Login to Dell IT Assistant 8.2 on a System Running the Windows Server 2008 SP2 Operating System Dell Ref: 189345 You may get an HTTPS error while logging in to Dell IT Assistant using a system that runs on the Windows Server 2008 SP2 operating system with Internet Explorer 7.0. This is an intermittent issue. To resolve this issue, add Dell IT Assistant to the list of trusted sites in Internet Explorer.
imp_info.book Page 16 Monday, March 21, 2011 1:52 PM Cluster Event Logs are Not in Chronological Order by Default Dell Ref: 141322 If you query the Cluster Events, the events are not sorted chronologically. You must scroll through the log to find any recent error. Microsoft has a fix for this issue. For more information, see the Microsoft Support site support.microsoft.com.
imp_info.book Page 17 Monday, March 21, 2011 1:52 PM The recommended DVD ROM drives for PowerEdge 2650, and 4600 systems do not display the issue. You can install the operating system from optical drives with the following part numbers: • 1J255 • 2M451 • 6R382 • 9T494 • FG219 • MI689 NOTE: The part number of the optical drive is located on the barcode sticker on the drive.
imp_info.book Page 18 Monday, March 21, 2011 1:52 PM Microsoft Application Verifier 3.1 Displays Software Licensing Error While Running slsvc.exe Process Dell Ref: 69097 When you run Microsoft Application Verifier 3.1 against the slsvc.exe (Software Licensing Service) process on a system that has an activated operating system, the following error appears: Software Licensing Service reported that the License is Tampered. Perform the following steps to remove slsvc.
imp_info.book Page 19 Monday, March 21, 2011 1:52 PM Virtual Floppy Drive is Listed as a Target Location for Windows Server Backup Tool Dell Ref: 120261 The Windows Server 2008 SP2 operating system reports the virtual floppy drive as a removable USB media, and the Windows Server Backup tool also lists as removable media devices for backup. Hence, the virtual floppy drive gets listed as one of the media options for taking backup. NOTE: It is not recommended to take a backup on a virtual floppy drive.
imp_info.book Page 20 Monday, March 21, 2011 1:52 PM Decrypting Status Bar Does Not Show the Accurate Status While Decrypting the Hard Drive Dell Ref: 163532 If you decide to turn off Bitlocker, and then decrypt the hard drive, a status bar pops up behind the Bitlocker window. When the status bar shows 9 to 20 percent increase, the bar disappears and the following message appears: Decryption of C: is complete. This is a known issue with the Windows Server 2008 SP2 operating system.
imp_info.book Page 21 Monday, March 21, 2011 1:52 PM Unable to Install the Windows Server 2008 Operating System on a Dell System with SCSI Disks Pre-Configured With RAID 1 Dell Ref: 102680 If you install the Windows Server 2008 SP2 operating system on SCSI disks pre-configured RAID 1 connected to a SCSI controller, the following error message appears: Windows is unable to find system volume that meets its criteria for installation—Please ensure that disk controller is BIOS enabled.
imp_info.book Page 22 Monday, March 21, 2011 1:52 PM Problem Reporting History Lists Application Crash When WER Service is Not Started Dell Ref: 116981 If Windows Error Reporting (WER) service is not started, the Problem Reporting History lists an application crash. The report may log an issue when you log into safe mode where WER service is disabled by default. The issue is seen with both Windows Server x86 and x64 Editions. This is a known issue with the Windows Server 2008 SP2 operating system.
imp_info.book Page 23 Monday, March 21, 2011 1:52 PM 4 Enable Allow remote access to the PnP interface on the system by performing the following steps: a Run MMC and add the Group Policy Object editor. b Connect to the remote system. Click Local Computer Policy Computer ConfigurationAdministrative TemplatesSystem Device Installation and enable Allow remote access to the PnP interface. 5 Restart the system.
imp_info.book Page 24 Monday, March 21, 2011 1:52 PM Windows Deployment Services (WDS) Server Does Not List the Language String and Build Number of the Operating System Image While Installing Through a Remote Server Dell Ref: 72794 When you boot a remote server to WDS to install the Windows Server 2008 SP2 operating system, you can select the operating system based on the images available on the WDS server. Presently, the build number is not displayed on the WDS server.
imp_info.book Page 25 Monday, March 21, 2011 1:52 PM Shutting Down a Cluster Node Inadvertently Brings Down the Cluster Dell Ref: 141340 In the server manager, if you stop the cluster service (MSCS) or shut down the node using StartShutdown, there is no warning message. However, the entire cluster is brought down. This is a known issue with the Windows Server 2008 SP2 operating system. Processor Speed Shown Incorrectly in the Windows Server 2008 Device Manager Dell Ref: 148587 When a 1.
imp_info.book Page 26 Monday, March 21, 2011 1:52 PM Incorrect FailoverThreshold Value Displayed for Groups on the Windows Command Line and the Windows GUI Dell Ref: 174983 In a 2-node Windows 2008 Server SP2 operating system Failover Cluster, the default FailoverThreshold value is shown as 0XFFFFFFFF in the Windows command line. In the Failover Cluster Management GUI, the FailoverThreshold value is displayed as 2. NOTE: Use the command cluster group /prop to get the FailoverThreshold value.
imp_info.book Page 27 Monday, March 21, 2011 1:52 PM System Properties Window Comes up When Windows Pre-Installation Environment (WinPE) is Enabled for OSLOADER Dell Ref: 72440 When WinPE is set ON in the BCD for OSLOADER, the System Properties window is displayed on subsequent reboots. This is a known issue with the Windows Server 2008 SP2 operating system. NOTE: The correct command is WinPE=Yes. WinPE=ON is an invalid command.
imp_info.book Page 28 Monday, March 21, 2011 1:52 PM 3 Create a new boot entry using the following command: bcdedit -create /d "Windows PE boot" /application OSLOADER This entry gives the option to boot to WINPE. 4 The step 3 returns the GUID that is associated with the newly created boot entry. It is referred to as NewGUID in the remaining examples. Run the following set of commands to configure the boot entry: bcdedit /set {NewGUID} device ramdisk= [c:]\sources\boot.
imp_info.book Page 29 Monday, March 21, 2011 1:52 PM BlueScreen During Startup or Shutdown When Hyper-V is Enabled on Systems With Intel Xeon 5600 Series Processors That Have Intel SMX Enabled Dell Ref: DF448819 A BlueScreen error may occur during startup or shutdown if you enable Hyper-V on a system containing Intel Xeon 5600 Series Processors that have the Intel SMX (Safer Mode Extensions) enabled with the TXT option in the BIOS.
imp_info.