Dell Command Line Reference Guide for the S4820T System 9.8(0.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright, 2009 – 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws.
Contents 1 About this Guide................................................................................................. 45 Objectives............................................................................................................................................45 Audience..............................................................................................................................................46 Conventions...................................................................
show os-version.................................................................................................................................. 91 show version....................................................................................................................................... 93 upgrade................................................................................................................................................95 verify....................................................
show alarms...................................................................................................................................... 140 show cam-acl-vlan........................................................................................................................... 141 show command-history................................................................................................................... 142 show command-tree............................................................
show ethernet cfm mipbd................................................................................................................ 193 show ethernet cfm statistics.............................................................................................................194 show ethernet cfm port-statistics.................................................................................................... 195 show ethernet cfm traceroute-cache...........................................................
deny.............................................................................................................................................230 ip access-list standard................................................................................................................ 232 permit.......................................................................................................................................... 233 resequence access-list....................................................
Route Map Commands..................................................................................................................... 291 continue.......................................................................................................................................291 description...................................................................................................................................292 match as-path..................................................................
deny (for Standard MAC ACLs)......................................................................................................... 334 deny (for Extended MAC ACLs)........................................................................................................ 336 permit (for Standard IP ACLs)........................................................................................................... 338 permit arp (for Extended MAC ACLs)..............................................................
bfd interval ....................................................................................................................................... 389 bfd neighbor..................................................................................................................................... 390 bfd protocol-liveness........................................................................................................................391 ip route bfd....................................................
debug ip bgp............................................................................................................................... 433 debug ip bgp dampening........................................................................................................... 435 debug ip bgp events................................................................................................................... 436 debug ip bgp keepalives........................................................................
router bgp................................................................................................................................... 480 set extcommunity bandwidth.....................................................................................................481 show capture bgp-pdu neighbor...............................................................................................482 show config................................................................................................
11 Content Addressable Memory (CAM)......................................................... 539 CAM Profile Commands................................................................................................................... 539 cam-acl (Configuration)............................................................................................................. 540 cam-acl-egress...........................................................................................................................
show interface ets....................................................................................................................... 578 show qos priority-groups........................................................................................................... 582 show stack-unit stack-ports ets details..................................................................................... 582 DCBX Commands............................................................................................
hardware watchdog.................................................................................................................... 619 show hardware layer2................................................................................................................ 620 show hardware layer3................................................................................................................. 621 show hardware stack-unit...........................................................................
ip dhcp snooping binding...........................................................................................................664 IPv6 DHCP Snooping Binding.................................................................................................... 665 ip dhcp snooping database........................................................................................................ 666 ipv6 dhcp snooping database write-delay.........................................................................
clear fip-snooping database interface vlan..................................................................................... 702 clear fip-snooping statistics............................................................................................................. 703 debug fip snooping...........................................................................................................................704 debug fip snooping rx.......................................................................
21 High Availability (HA)..................................................................................... 744 patch flash://RUNTIME_PATCH_DIR...............................................................................................744 process restartable............................................................................................................................745 redundancy auto-failover-limit..........................................................................................
show ip igmp snooping groups..................................................................................................785 show ip igmp snooping mrouter................................................................................................ 787 24 Interfaces.........................................................................................................789 Basic Interface Commands.........................................................................................................
speed (Management interface)................................................................................................... 851 stack-unit portmode...................................................................................................................852 switchport................................................................................................................................... 853 Egress Interface Selection (EIS) Commands.......................................................
26 IPv4 Routing....................................................................................................891 arp......................................................................................................................................................891 arp backoff-time...............................................................................................................................892 arp learn-enable.........................................................................
show hosts........................................................................................................................................ 941 show ip cam linecard....................................................................................................................... 943 show ip cam stack-unit....................................................................................................................946 show ip fib linecard.......................................................
ipv6 unicast-routing....................................................................................................................... 1001 show ipv6 cam stack-unit.............................................................................................................. 1002 show ipv6 control-plane icmp.......................................................................................................1003 show ipv6 fib stack-unit...................................................................
domain-password...........................................................................................................................1041 graceful-restart ietf.........................................................................................................................1042 graceful-restart interval..................................................................................................................1043 graceful-restart restart-wait.................................................
show isis hostname........................................................................................................................ 1086 show isis interface...........................................................................................................................1087 show isis neighbors........................................................................................................................ 1088 show isis protocol..........................................................
untagged....................................................................................................................................1134 Far-End Failure Detection (FEFD)................................................................................................... 1135 debug fefd..................................................................................................................................1135 fefd.................................................................................
34 Microsoft Network Load Balancing.......................................................... 1171 arp (for Multicast MAC Address)...................................................................................................... 1171 mac-address-table static (for Multicast MAC Address)................................................................. 1172 ip vlan-flooding...............................................................................................................................
tc-flush-standard.............................................................................................................................1211 37 Multicast.........................................................................................................1213 IPv4 Multicast Commands.............................................................................................................. 1213 clear ip mroute........................................................................................
track interface ip routing...........................................................................................................1247 track interface line-protocol.................................................................................................... 1248 track ip route metric threshold.................................................................................................1249 track ip route reachability...............................................................................
ip ospf network......................................................................................................................... 1289 ip ospf priority........................................................................................................................... 1290 ip ospf retransmit-interval.........................................................................................................1291 ip ospf transmit-delay..................................................................
default-information originate................................................................................................... 1352 graceful-restart grace-period...................................................................................................1353 graceful-restart mode...............................................................................................................1354 ipv6 ospf area..............................................................................................
ip pim join-filter.........................................................................................................................1397 ip pim ingress-interface-map...................................................................................................1398 ip pim neighbor-filter................................................................................................................1399 ip pim query-interval............................................................................
extend system-id............................................................................................................................ 1443 protocol spanning-tree pvst.......................................................................................................... 1444 show spanning-tree pvst................................................................................................................1445 spanning-tree pvst.....................................................................
service-policy output................................................................................................................1486 service-queue........................................................................................................................... 1487 set.............................................................................................................................................. 1488 show qos class-map...............................................................
offset-list..........................................................................................................................................1527 output-delay................................................................................................................................... 1528 passive-interface.............................................................................................................................1529 redistribute..................................................
51 Security...........................................................................................................1574 AAA Accounting Commands.......................................................................................................... 1574 aaa accounting.......................................................................................................................... 1574 aaa accounting suppress.........................................................................................
TACACS+ Commands.....................................................................................................................1615 tacacs-server group.................................................................................................................. 1615 debug tacacs+...........................................................................................................................1616 ip tacacs source-interface....................................................................
show crypto...............................................................................................................................1653 show ip ssh................................................................................................................................ 1655 show ip ssh client-pub-keys.................................................................................................... 1656 show ip ssh rsa-authentication.............................................................
54 Simple Network Management Protocol (SNMP) and Syslog............... 1692 SNMP Commands...........................................................................................................................1692 show snmp................................................................................................................................ 1693 show snmp engineID................................................................................................................1694 show snmp group..
show logging............................................................................................................................. 1737 show logging auditlog.............................................................................................................. 1738 show logging driverlog stack-unit............................................................................................1739 terminal monitor......................................................................................
spanning-tree.................................................................................................................................. 1781 59 System Time and Date.................................................................................1784 clock summer-time date................................................................................................................ 1784 clock summer-time recurring......................................................................................
description...................................................................................................................................... 1820 downstream.....................................................................................................................................1821 downstream auto-recover............................................................................................................. 1822 downstream disable links...................................................
system-mac.....................................................................................................................................1861 unit-id..............................................................................................................................................1862 vlt domain....................................................................................................................................... 1863 vlt-peer-lag port-channel..................................
show config.............................................................................................................................. 1894 show vrrp...................................................................................................................................1895 track...........................................................................................................................................1899 version....................................................................
About this Guide 1 This book provides information about the Dell Networking OS command line interface (CLI). This book also includes information about the protocols and features found in Dell Networking OS.
Audience This book is intended for system administrators who are responsible for configuring or maintaining networks. This guide assumes that you are knowledgeable in Layer 2 and Layer 3 networking technologies. Conventions This book uses the following conventions to describe command syntax. Keyword Keywords are in Courier font and must be entered in the CLI as listed. parameter Parameters are in italics and require a number or word to be entered in the CLI.
CLI Basics 2 This chapter describes the command line interface (CLI) structure and command modes. The Dell Networking operating software commands are in a text-based interface that allows you to use the launch commands, change command modes, and configure interfaces and protocols. Accessing the Command Line When the system boots successfully, you are positioned on the command line in EXEC mode and not prompted to log in. You can access the commands through a serial console port or a Telnet session.
User "admin" on line vty0 ( 123.12.1.123 ) User "admin" on line vty1 ( 123.12.1.123 ) User "Irene" on line vty3 ( 123.12.1.321 ) Dell#conf When another user enters CONFIGURATION mode, Dell Networking OS sends a message similar to the following: % Warning: User "admin" on line vty2 "172.16.1.210" is in configuration In this case, the user is “admin” on vty2. Obtaining Help As soon as you are in a command mode there are several ways to access help.
radius redirect-list route scp source-route options ssh tacacs telnet tftp trace-group trace-list Dell(conf)#ip Interface configuration for RADIUS Named redirect-list Establish static routes SCP configuration commands Process packets with source routing header SSH configuration commands Interface configuration for TACACS+ Specify telnet options TFTP configuration commands Named trace-list Named trace-list When entering commands, you can take advantage of the following timesaving features: • The commands
Key Combination Action Esc F Moves the cursor forward one word. Esc D Deletes all the characters from the cursor to the end of the word. Navigating the CLI Dell Networking OS displays a CLI prompt comprised of the host name and CLI mode. • Host name is the initial part of the prompt and is “Dell” by default. You can change the host name with the hostname command. • CLI mode is the second part of the prompt and reflects the current CLI mode.
grep displays text that matches a pattern. The grep command option has an ignore-case suboption that makes the search case-insensitive.
You can activate VRF application on a device by using the feature vrf command in CONFIGURATION mode. NOTE: The no feature vrf command is not supported on any of the platforms. To enable the VRF feature and cause all VRF-related commands to be available or viewable in the CLI interface, use the following command. You must enable the VRF feature before you can configure its related attributes.
show feature Verify the status of software applications, such as VRF, that are activated and running on a device. S4820T Syntax show feature Command Modes EXEC Command History EXEC Privilege Version 9.4(0.0) Introduced on the S4810, S4820T, and S6000. Usage Information You can activate VRF application on a device by using the feature vrf command in CONFIGURATION mode. The no feature vrf command is not supported on any of the platforms.
To enter CLASS-MAP mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the class-map command then enter the class map name. The prompt changes to include (config-class-map). You can return to CONFIGURATION mode by using the exit command. CONFIGURATION Mode In EXEC Privilege mode, use the configure command to enter CONFIGURATION mode and configure routing protocols and access interfaces. To enter CONFIGURATION mode: 1. Verify that you are logged in to EXEC Privilege mode. 2.
2. Enter the ip dhcp server command. The prompt changes to include (config-dhcp). You can return to CONFIGURATION mode by using the exit command. DHCP POOL Mode To create an address pool, use DHCP POOL mode. For more information, refer to Dynamic Host Configuration Protocol (DHCP). To enter DHCP POOL mode: 1. Verify that you are logged in to DHCP mode. 2. Enter the pool command then the pool name. The prompt changes to include (config-dhcp-poolname).
can access CONFIGURATION mode to configure interfaces, routes and protocols on the switch. While you are logged in to EXEC Privilege mode, the # prompt is displayed. EXTENDED COMMUNITY LIST Mode To enable and configure a BGP extended community, use EXTENDED COMMUNITY LIST mode. To enter EXTENDED COMMUNITY LIST mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the ip extcommunity-list command then a community list name. The prompt changes to include (conf-ext-community-list).
Prompt Interface Type Dell(conf-ifnu-0)# Null Interface then zero Dell(conf-ifpo-0)# Port-channel interface number Dell(conf-ifvl-0)# VLAN Interface then VLAN number (range 1–4094) Dell(conf-ifma-0/0)# Management Ethernet interface then slot/port information Dell(conf-iftu-0)# Tunnel interface then tunnel ID. Dell(conf-ifrange)# Designated interface range (used for bulk configuration).
LLDP MANAGEMENT INTERFACE Mode To enable and configure Link Layer Discovery Protocol (LLDP) on management interfaces, use LLDP MANAGEMENT INTERFACE mode. To enter LLDP MANAGEMENT INTERFACE mode: 1. Verify that you are logged in to LLDP mode. 2. Enter the management-interface command. The prompt changes to include (conf-lldp-mgmtIf). LINE Mode To configure the console or virtual terminal parameters, use LINE mode. To enter LINE mode: 1. Verify that you are logged in to CONFIGURATION mode. 2.
2. Enter the protocol spanning-tree mstp command. The prompt changes to include (confmstp). You can return to CONFIGURATION mode by using the exit command. OPENFLOW INSTANCE Mode To enable and configure OpenFlow instances, use OPENFLOW INSTANCE mode. To enter OPENFLOW INSTANCE mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the openflow of-instance command then the OpenFlow ID number of the instance you want to create or configure.
PRIORITY GROUP Mode To create an ETS priority group, use PRIORITY GROUP mode. For more information, refer to ETS Commands. To enter PRIORITY GROUP mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the priority-group command then the group name. The prompt changes to include (confpg). You can return to CONFIGURATION mode by using the exit command. PROTOCOL GVRP Mode To enable and configure GARP VLAN Registration Protocol (GVRP), use PROTOCOL GVRP mode.
2. Use the route-map map-name [permit | deny] [sequence-number] command. The prompt changes to include (config-route-map). You can return to CONFIGURATION mode by using the exit command. ROUTER BGP Mode To enable and configure Border Gateway Protocol (BGP), use ROUTER BGP mode. For more information, refer to Border Gateway Protocol IPv4 (BGPv4) To enter ROUTER BGP mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Use the router bgp command then enter the AS number.
ROUTER RIP Mode To enable and configure Router Information Protocol (RIP), use ROUTER RIP mode. For more information, refer to Routing Information Protocol (RIP). To enter ROUTER RIP mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the router rip command. The prompt changes to include (conf-router_rip). You can return to CONFIGURATION mode by using the exit command. SPANNING TREE Mode To enable and configure the Spanning Tree protocol, use SPANNING TREE mode.
1. To enable VRRP globally, verify that you are logged in to CONFIGURATION mode. 2. Enter the vrrp-group command then enter the VRRP group ID. The prompt changes to include (conf-if-interface-type-slot/port-vrid-vrrp-group-id). u-Boot Mode To enable u-Boot mode, press any key when the following line appears on the console during a system boot: Hit any key to stop autoboot:. The prompt changes to include ( =>). For more information, refer to S4810 u-Boot.
3 File Management This chapter contains command line interface (CLI) commands needed to manage the configuration files as well as other file management commands. boot system Tell the system where to access the Dell Networking OS image used to boot the system. Syntax boot system {gateway ip address| stack-unit [{stack-unit-number | all] [default | primary {system {A: | B: | bmp-boot} | tftp: | | secondary]} To return to the default boot sequence, use the no boot system command.
bmp-boot Enter the keyword bmp-boot to boot the system, when the you are not sure about the partition that contains image from DHCP offer. NOTE: In normal-reload, this keyword is not enabled. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
NOTE: While switching to a remote NFS file system, it is mandatory to specify the mount-point that indicates the working directory on the NFS file system. You cannot enter the root directory of the remote NFS file system. • usbflash: (internal Flash) or any sub-directory Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Password to login remote host: Destination file name [sample_file]: Defaults None. Command Modes EXEC Privilege Command History Version Description 9.3(0.1) Introduced on the S6000, Z9000, S4810, and S4820T. Example copy http://admin:admin123@10.16.206.77/sample_file flash:// sample_file Related Commands copy ftp:flash Copy files from FTP server to switch copy Copy one file to another location. Dell Networking OS supports IPv4 and IPv6 addressing for FTP, TFTP, and SCP (in the hostip field).
To copy a file on a HTTP server enter http: http://hostip/ filepath To copy a file on a NFS mounted system enter nfsmount://
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. Added the nfsmount: parameters that enables you to mount a remote NFS file system. 9.4(0.0) Added the compressed-config parameter. 9.
• copy running-config ftp: • copy running-config nfsmount:///filepath You can compress the running configuration by grouping all the VLANs and the physical interfaces with the same property. Support to store the operating configuration to the startup config in the compressed mode and to perform an image downgrade without any configuration loss are provided. Two existing exec mode CLIs are enhanced to display and store the running configuration in the compressed mode.
delete Delete a file from the flash. After deletion, files cannot be restored. Syntax Parameters delete flash-url [no-confirm] flash-url Enter the following location and keywords: • For a file or directory on the internal Flash, enter flash:// followed by the filename or directory name. • For a file or directory on the NFS mounted file system, enter nfsmount:// followed by the mount point and the file path.
dir Display the files in a file system. The default is the current directory. Syntax Parameters dir [filename | directory name:] filename | directory name: (OPTIONAL) Enter one of the following: • For a file or directory on the internal Flash, enter flash:// then the filename or directory name. • For a file or directory on an NFS mounted file system, enter nfsmount:// followed by the mount point and file path.
4 drwx 4096 Jan 01 CORE_DUMP_DIR 5 d--4096 Jan 01 6 drwx 4096 Jan 01 RUNTIME_PATCH_DIR 7 drwx 4096 Nov 06 CONFIG_TEMPLATE 8 -rwx 4625 Nov 06 config 9 drwx 4096 May 31 CONFD_LOG_DIR flash: 2056916992 bytes total Example (NFS Mount) 1980 00:02:44 +00:00 1980 00:02:44 +00:00 ADMIN_DIR 1980 00:02:44 +00:00 2014 06:57:06 +00:00 2014 06:55:28 +00:00 startup2013 02:49:46 +00:00 (2052784128 bytes free) Dell#dir nfsmount: Directory of nfsmount: 1 2 drwx drwx 512 512 Nov 06 2014 06:58:19 +00:00 .
Usage Information You must include the colon (:) when entering this command. After reformatting is complete, three empty directories are automatically created on flash: CRASH_LOG_DIR, TRACE_LOG_DIR and NVTRACE_LOG_DIR. CAUTION: This command deletes all files, including the startup configuration file. So, after executing this command, consider saving the running config as the startup config (use the write memory command or copy run start command).
CAUTION: If you elect to format the flash, all files – including the startup configuration file – are lost. If you do decide to format the specified flash, consider saving the running configuration as the startup configuration after formatting the flash (use the write memory command or copy run start command). Related Commands • copy — copy one file to another location. • show file-systems — Display information about the file systems on the system.
username (OPTIONAL) Enter the user name to access the device. password (OPTIONAL) Enter the password. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S-Series.
upgrade system Upgrade the Dell Networking OS image. To upgrade the bootflash or bootselector image, use the upgrade boot command. Syntax Parameters upgrade system {flash: | ftp: | nfsmount: | scp: | stack-unit {stack-unit-id | all} | tftp: | usbflash:} file-url {A: |B:} system Enter the keyword system to upgrade the operating system (OS) image. flash: file-url Enter the keyword flash: and specify the location of the image file in the format //directory-path or press Enter to launch a prompt sequence.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added support for NFS mount. 9.2(1.0) Introduced on the Z9500. 9.0(0.0) Added support for IPv6 for the file-url parameter. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000.
rename Rename a file in the local file system. Syntax Parameters rename url url url Enter the following keywords and a filename: • For a file on the internal Flash, enter flash:// followed by the filename. • For a file on an NFS mounted file system, enter nfsmount:// followed by the mount point and file path. • For a file on an external USB drive, enter usbflash:// followed by the filename. Command Modes EXEC Privilege Command History This guide is platform-specific.
Parameters factorydefaults Return the system to its factory default mode. stack-unitnumber Enter the stack member unit identifier to restore only the mentioned stack-unit. For the S4810, the range is from 0 to 11. all Enter the keyword all to restore all units in the stack. bootvar Enter the keyword bootvar to reset boot line. clear-all Enter the keywords clear-all to reset the NvRAM, boot environment variables, and the system startup configuration.
• baudrate • primary_boot • secondary_boot • default_boot • ipaddr • gatewayip • netmask • macaddr • mgmtautoneg • mgmtspeed100 • mgmtfullduplex Each boot path variable (primary_boot, secondary_boot, and default_boot) is further split into the following three independent variables: • primary_server, primary_file, and primary_type • secondary_server, secondary_file, and secondary_type • default_server, default_file, and default_type NOTE: For information on the default values that
fanout, etc.)* * After restoration the unit(s) will be powercycled immediately. * * Proceed with caution ! * ************************************************************** Proceed with factory settings? Confirm [yes/no]:yes -- Restore status -Unit Nvram Config -----------------------0 Success Success Power-cycling the unit(s).
show boot system Displays information about boot images currently configured on the system. Syntax Parameters show boot system {stack-unit | all} all Enter the keyword all to display the boot image information for all stack units. stack-unit Enter the keyword stack-unit followed by a number to display boot image information for a stack-unit. The S4810 range is from 0 to 11. Defaults none Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific.
show bootvar Display the variable settings for the boot parameters. Syntax show bootvar Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example 84 Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
show file-systems Display information about the file systems on the system. Syntax show file-systems Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Command Fields File Management Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Field Prefixes Related Commands Description • r = read access • w = write access Displays the name of the storage location. format flash (S-Series) – Erases all the existing files and reformats the filesystem in the internal flash memory on the S-Series. show running-config Display the current configuration and display changes from the default values.
File Management fefd for the current FEFD configuration ftp for the current FTP configuration frrp for the current FRRP configuration fvrp for the current FVRP configuration gvrp for the current GVRP configuration host for the current host configuration hardwaremonitor for hardware-monitor action-on-error settings hypervisor for the current hypervisor configuration igmp for the current IGMP configuration interface for the current interface configuration interface port-channel for the c
ospf for the current OSPF configuration pim for the current PIM configuration policy-mapinput for the current input policy map configuration policy-mapoutput for the current output policy map configuration po-failovergroup for the current port-channel failovergroup configuration prefix-list for the current prefix-list configuration privilege for the current privilege configuration qos-policyinput for the current input QoS policy configuration qos-policyoutput for the current output QoS
uplinkstate-group for the uplink state group configuration users for the current users configuration vlt for the current VLT configuration wred-profile for the current wred-profile configuration configured (OPTIONAL) Enter the keyword configuration to display line card interfaces with non-default configurations only. status (OPTIONAL) Enter the keyword status to display the checksum for the running configuration and the start-up configuration.
Example Dell# show running-config Current Configuration ... ! Version 9-0(2-0) ! Last configuration change at Thu Apr 18 10:18:39 2013 by admin ! Startup-config last updated at Thu Apr 18 10:18:40 2013 by admin ! boot system stack-unit 0 primary system: A: boot system stack-unit 0 secondary tftp://10.16.127.35/DellSI-9-0-2-0.bin boot system stack-unit 0 default system: A: boot system gateway 10.16.132.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on S-Series 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Expanded to include the last configuration change, start-up last updated (date and time), and who made the change.
Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
Stack-unit 0 S6000 SLAVE CPLD 10 Dell# Usage Information NOTE: A filepath that contains a dot ( . ) is not supported. show version Display the current Dell Networking Operating System (OS) version information on the system. Syntax show version Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Example (SSeries) Lines Beginning With Description Dell Networking OS uptime is... Amount of time the system has been up System image... Image file name System Type: S4810, S4820T, Z9000, S6000 Control Processor:... Control processor information and amount of memory on processor 128K bytes... Amount and type of memory on system 1 Route Processor...
SRCC Dell Networking OS uptime is 1 day(s), 0 hour(s), 19 minute(s) System image file is "DT-MAA-S6000-16-PI" System Type: S6000 Control Processor: Intel Centerton with 3203911680 bytes of memory, core(s) 2. 16G bytes of boot flash memory. 1 32-port TE/FG (SI) 32 Forty GigabitEthernet/IEEE 802.3 interface(s) upgrade Upgrade the bootflash image or system image of the management unit.
file-url Enter the following location keywords and information to upgrade using an Dell Networking OS image other than the one currently running: • To specify an Dell Networking OS image on the internal flash, enter flash:// file-path/filename. • To specify an Dell Networking OS image on an FTP server, enter ftp://user:password@hostip/ filepath. • To specify an Dell Networking OS image on the external flash, enter slot0://file-path/filename.
tftp: Copy from remote file system (tftp://hostip/filepath) Dell# upgrade system ftp://username:password@10.11.1.1/FTOSSB-7.7.1.0.bin !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! !!!!!!!!!!!!!!!!!!!!!! Erasing Sseries ImageUpgrade Table of Contents, please wait .!............................................................. ..................................... ............................................................... ...........................
Defaults flash drive Command Modes EXEC mode Command History Version 9.5.(0.0) Usage Information Example Version Description 9.5(0.0) Introduced on the Z9000, S6000, S4820T, S4810, and MXL. You can enter this command in the following ways: • verify md5 flash://img-file • verify md5 flash://img-file • verify sha256 flash://img-file • verify sha256 flash://img-file Without Entering the Hash Value for Verification using SHA256 Dell# verify sha256 flash://FTOS-SE-9.
Control and Monitoring 4 This chapter contains the commands to configure and monitor the system, including Telnet, file transfer protocol (FTP), and trivial file transfer protocol (TFTP). NOTE: This command replaces the enable optic-info-update interval command to update information on temperature and power monitoring in the simple network management protocol (SNMP) management information base (MIB).
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.0 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. You must save the configuration and reload the system to implement ASF. When you enter the command, the system sends a message stating that the new mode is enabled when the system reloads. banner exec Configure a message that is displayed when your enter EXEC mode. Syntax banner exec c line c To delete a banner, use the no banner exec command.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original Command Usage Information After entering the banner login command, type one or more spaces and a delineator character. Enter the banner text then the second delineator character. When the user is connected to the router, if a message of the day banner is configured, it displays first. If no message of the day banner is configured, the login banner and prompt appear.
Parameters keyboardinteractive Enter the keyword keyboard-interactive to require a carriage return (CR) to get the message banner prompt. c Enter a delineator character to specify the limits of the text banner. The delineator is a percent character (%). line Enter a text string for your text banner message ending the message with your delineator. The delineator is a percent character (%).
This is the banner% Dell(conf)#end Dell#exit 13d21h9m: %RPM0-P:CP %SEC-5-LOGOUT: Exec session is terminated for user on line console This is the banner Dell con0 now available Press RETURN to get started. 13d21h10m: %RPM0-P:CP %SEC-5-LOGIN_SUCCESS: Login successful for user on line console This is the banner Dell> Related Commands banner motd — sets a Message of the Day banner. banner exec — enables the display of a text string when you enter EXEC mode. banner motd Set a message of the day (MOTD) banner.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command Usage Information After entering the banner login command, type one or more spaces and a delineator character. Enter the banner text then the second delineator character.
• iSCSI Optimization (iscsioptacl): 0 (disabled) Allocate space to each CAM region. Enter the CAM profile name then the amount of CAM space to be allotted. The total space allocated must equal 13. The ipv6acl range must be a factor of 2. Enter 4 or 8 for the number of OpenFlow FP blocks.
Usage Information For the new settings to take effect, save the new CAM settings to the startupconfig (write-mem or copy run start) then reload the system. The total amount of space allowed is 16 FP Blocks. System flow requires three blocks and these blocks cannot be reallocated. The ipv4acl profile range is from 1 to 4. When configuring space for IPv6 ACLs, the total number of Blocks must equal 13. Ranges for the CAM profiles are from 1 to 10, except for the ipv6acl profile which is from 0 to 10.
For platform-specific instructions about using this command, refer to the SDN chapter in the Dell Networking OS Configuration Guide. clear line Reset a terminal line. Syntax Parameters clear line {line-number | console 0 | vty number} line-number Enter a number for one of the 12 terminal lines on the system. The range is from 0 to 11. aux 0 Enter the keywords aux 0 to reset the auxiliary port. console 0 Enter the keywords console 0 to reset the console port.
configure Enter CONFIGURATION mode from EXEC Privilege mode. Syntax Parameters configure [terminal] terminal (OPTIONAL) Enter the keyword terminal to specify that you are configuring from the terminal. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Defaults 1 Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.
Usage Information Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Added support for roles on the Z9000, S6000, S4820T, S4810, and MXL. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.
Parameters interval seconds Enter the keyword interval then the polling interval in seconds. The range is from 120 to 6000 seconds. The default is 300 seconds (5 minutes). Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command History • COMMUNITY-LIST • ROUTER OSPF • ROUTER RIP • ROUTER ISIS • ROUTER BGP This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.
Defaults 10 minutes for console line; 30 minutes for VTY lines; 0 seconds Command Modes LINE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.
• Command History AS-PATH ACL • COMMUNITY-LIST • PREFIX-LIST • ROUTER OSPF • ROUTER RIP • ROUTER ISIS • ROUTER BGP This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example 116 Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.
ftp-server topdir Specify the top-level directory to be accessed when an incoming FTP connection request is made. Syntax Parameters ftp-server topdir directory directory Enter the directory path. Defaults The internal flash is the default directory. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
ftp-server username Create a user name and associated password for incoming FTP server sessions. Syntax ftp-server username username password [encryption-type] password To delete a user name and its password, use the no ftp-server username username command. Parameters username Enter a text string up to 40 characters long as the user name. password password Enter the keyword password then a string up to 40 characters long as the password.
hostname Set the host name of the system. Syntax Parameters hostname name name Enter a text string, up to 32 characters long. Defaults Dell Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.
Parameters encryptiontype password (OPTIONAL) Enter one of the following numbers: • 0 (zero) for an unecrypted (clear text) password • 7 (seven) for a hidden text password Enter a string up to 40 characters as the password. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
ip ftp vrf Configures an FTP client with a VRF that is used to connect to the FTP server. Syntax ip ftp [vrf vrf-name] To undo the FTP client configuration, use the ip ftp [vrf vrf-name] command. Parameters vrf vrf-name Enter the keyword vrf and then the name of the VRF to specify the VRF that is used by the FTP client. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific.
• For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords portchannel then a number. The range is from 1 to 128. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. • For a tunnel interface, enter the keyword tunnel.
To return to anonymous FTP connections, use the no ip ftp username [username] command. Parameters username Enter a text string as the user name up to 40 characters long. Defaults No user name is configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.4.(0.0) Introduced on the S-Series and Z9000.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.
• For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords portchannel then a number. The range is from 1 to 128. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Defaults The IP address on the system that is closest to the Telnet address is used in the outgoing packets.
Parameters vrf vrf-name Enter the keyword vrf and then the name of the VRF to specify the VRF that is used by the TFTP client. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.
Defaults Not configured Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000.
Parameters limit numberof-sessions Sets the number of concurrent sessions that any user can have on console and virtual terminal lines. The range is from 1 to 12 (10 VTY lines, one console, and one AUX line). clear-line enable Enables you to clear your existing sessions. Defaults Not configured. You can use all the available sessions. Command Modes CONFIGURATION Command History This guide is platform-specific.
Login: admin Password: Current sessions for user admin: Line Location 2 vty 0 10.14.1.97 3 vty 1 10.14.1.97 Clear existing session? [line number/Enter to cancel]: When you try to create more than the permitted number of sessions, the following message appears, prompting you to close one of your existing sessions. Close any of your existing sessions to log in to the system. $ telnet 10.11.178.14 Trying 10.11.178.14... Connected to 10.11.178.14. Escape character is '^]'.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S4810, S4820, S5000, S6000, S6000ON, and Z9500.
The preceding message shows that the user had previously logged in to the system using the console line. It also displays the number of unsuccessful login attempts since the last login and the number of unsuccessful login attempts during a custom time period. Related Commands login concurrent-session — Configures the limit of concurrent sessions for all users on console and virtual terminal lines.
ping Test connectivity between the system and another device by sending echo requests and waiting for replies.
tos (IPv4 only) Enter the type of service required. The range is from 0 to 255. The default is 0. df-bit (IPv4 only) Enter Y or N for the “don't fragment” bit in IPv4 header. • N: Do not set the “don't fragment” bit. • Y: Do set “don't fragment” bit Default is No. validate-reply (IPv4 only) Enter Y or N for reply validation. • N: Do not validate reply data. • Y: Do validate reply data. Default is No.
Version 9.0.2.0 Introduced on the S6000. Version 9.0.0.0 Introduced on the Z9000. Version 8.3.19.0 Introduced on the S4820T. Added support for the outgoing-interface option for link-local IPv6 addressing on the S4820T. Usage Information Version 8.3.12.0 Added support for the outgoing-interface option for link-local IPv6 addressing on the S4810. Version 8.3.11.1 Introduced on the Z9000. Version 8.3.7.0 Introduced on the S4810. Version 8.5.1.
Sending 5, 100-byte ICMP Echos to 172.31.1.255, timeout is 2 seconds: Reply to request 1 from 172.31.1.208 0 ms Reply to request 1 from 172.31.1.216 0 ms Reply to request 1 from 172.31.1.205 16 ms :: Reply to request 5 from 172.31.1.209 0 ms Reply to request 5 from 172.31.1.66 0 ms Reply to request 5 from 172.31.1.87 0 ms Dell# Example (IPv6) Dell#ping 100::1 Type Ctrl-C to abort. Sending 5, 100-byte ICMP Echos to 100::1, timeout is 2 seconds: !!!!! Success rate is 100.
Usage Information Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command. If there is a change in the configuration, FTOS prompts you to save the new configuration. Or you can save your running configuration with the copy running-config command. Use the conditional parameter if any configuration changes made to the nvram, such as stack-group and fanout configurations, must be saved. send Send messages to one or all terminal line users.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.5.1.0 Introduced on the E-Series. Messages can contain an unlimited number of lines; however, each line is limited to 255 characters. To move to the next line, use . To send the message use CTR-Z; to abort a message, use CTR-C. service timestamps To debug and log messages, add time stamps.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.
The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command.
Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description Version 9.1.(0.0) Introduced on S4810. Version 8.3.19.0 Introduced on the S4820T. show command-history Display a buffered log of all commands all users enter along with a time stamp.
hostname Force10]by default from console - Repeated 3 times.
show command-tree Display the entire CLI command tree, and optionally, display the utilization count for each command and its options. Syntax Parameters Defaults Command Modes Command History show command-tree [count | no] count Display the command tree with a usage counter for each command. no Display all of the commands that may be preceded by the keyword no, which is the keyword used to remove a command from the running-configuration. none • • EXEC EXEC Privilege This guide is platform-specific.
! Global configuration mode: aaa authentication enable command usage:1 WORD option usage: 1 default option usage: 0 enable option usage: 0 line option usage: 0 none option usage: 0 radius option usage: 1 tacacs+ option usage: 0 show cpu-traffic-stats View the CPU traffic statistics. Syntax Parameters show cpu-traffic-stats [port number | all | cp ] port number (OPTIONAL) Enter the port number to display traffic statistics on that port only. The range is from 1 to 1568.
Usage Information Version Description 7.5.1.0 Introduced on the C-Series 6.2.1.1 Introduced on the E-Series. Traffic statistics are sorted on a per-interface basis; the interface receiving the most traffic is displayed first. All CPU and port information is displayed unless a specific port or CPU is specified. Traffic information is displayed for router ports only; not for management interfaces.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series E-Series Original command.
Command Modes Command History • • EXEC EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.
-----0 31 40 46 36 37 37 31 Dell#show environment fan -- Fan Status -Unit Bay TrayStatus Fan0 Speed Fan1 Speed ----------------------------------------------------------------------------------0 0 up up 7021 up 7021 0 1 up up 6971 up 7072 0 2 up up 7021 up 6971 Speed in RPM Dell#show environment pem -- Power Supplies -Unit Bay Status Type FanStatus FanSpeed(rpm) -------------------------------------------------------------------------0 0 down UNKNOWN down 0 0 1 up AC up 6504 Dell#show environment ther
Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.
Example Related Commands Dell#show inventory media Slot Port Type Media Serial Number F10Qualified ----------------------------------------------------------------------------0 0 QSFP 40GBASE-CR4-1M APF11200012UQQ Yes 0 1 QSFP 40GBASE-CR4-1M APF11200012UQQ Yes 0 2 QSFP 40GBASE-CR4-1M APF11200012UQQ Yes 0 3 QSFP 40GBASE-CR4-1M APF11200012UQQ Yes 0 4 QSFP 40GBASE-CR4-1M APF11200012UR1 Yes 0 5 QSFP 40GBASE-CR4-1M APF11200012UR1 Yes 0 6 QSFP 40GBASE-CR4-1M APF11200012UR1 Yes 0 7 QSFP 40GBASE-CR4-1M APF1120001
unsuccessfulattempts (Optional)Displays the number of failed login attempts by the current user in the last 30 days or the custom defined time period. time-period days (Optional)Displays the number of failed login attempts by the current user in the specified period. Defaults None Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
----------------------------------------------------------------The following is sample output of the show login statistics all command. Dell#show login statistics all ----------------------------------------------------------------User: admin Last login time: Mon Feb 16 04:40:00 2015 Last login location: Line vty0 ( 10.14.1.
The following is sample output of the show login statistics unsuccessful-attempts user login-id command. Dell#show login statistics unsuccessful-attempts user admin There were 3 unsuccessful login attempt(s) for user admin in last 12 day(s). Related Commands login statistics — Enable and configure user login statistics on console and virtual terminal lines. login concurrent-session — Configures the limit of concurrent sessions for all users on console and virtual terminal lines.
Usage Information The output for show memory displays the memory usage of LP part (sysdlp) of the system. The sysdlp is an aggregate task that handles all the tasks running on the SSeries’ CPU.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.
0.00% 0.00% 0xbad85000 0.00% 0.00% 0xbad9a000 0.00% 0.00% 0xbadb4000 0.00% 0.00% 0xbadc9000 0.00% 0.00% 0xbae22000 0.00% 0.02% 0 1190 0 0 0 30 0 10 0 60 0 PM 119 KP 0 evagt 3 ipc 1 sysReaper 6 tme 10000 0.00% 0 0.00% 10000 0.00% 10000 0.00% 10000 0.
details | Detail CPU utilization Pipe through a command Dell#show processes cpu management-unit CPUID 5sec 1min 5min -------------------------------------------------CORE 0 9.54 9.92 12.82 CORE 2 10.74 11.56 14.31 Overall 10.14 10.74 13.56 PID Runtime(ms) 1Min 5Min TTY 0x00000000 45040 13.20% 12.94% 0 0x000001ac 25750 2.48% 3.40% 0 0x0000019a 10650 1.16% 2.50% 0 0x000003a5 860 0.22% 0.28% 0 0x000001ad 520 0.30% 0.16% 0 0x000004ba 330 0.36% 0.09% 0 0x000000c9 1240 0.15% 0.44% 0 0x000000e0 530 0.12% 0.
show processes memory (S-Series) — displays CPU usage information based on processes running in an S-Series. show processes ipc flow-control Display the single window protocol queue (SWPQ) statistics. Syntax Parameters show processes ipc flow-control [cp] cp (OPTIONAL) Enter the keyword cp to view the control processor’s SWPQ statistics. Defaults none Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific.
Field Description Cur Len Current number of messages enqueued High Mark Highest number of packets in the queue at any time #of to / Timeout Timeout count #of Retr /Retries Number of retransmissions #msg Sent/Msg Sent/ Number of messages sent #msg Ackd/Ack Rcvd Number of messages acknowledged Retr /Available Retra Number of retries left Total/ Max Retra Number of retries allowed Important Points: Example (SSeries) • The SWP provides flow control-based reliable communication between the s
all Enter the keyword all for detailed memory usage on all stack members. summary Enter the keyword summary for a brief summary of memory availability and usage on all stack members. Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
show processes memory output Field Description Frees Total dynamic memory freed Max Maximum dynamic memory allocated Current Current dynamic memory in use The output for the show process memory command displays the memory usage statistics running on CP part (sysd) of the system. The sysd is an aggregate task that handles all the tasks running on S-Series’ CP. For the S-Series, the output of the show memory command and this command differ based on which FTOS processes are counted.
273 acl 5005312 512000 239564 149076 123616 272 topoDPC 117927936 0 0 0 0 271 bcmNHOP 117927936 0 0 0 0 270 bcmDISC 117927936 0 0 0 0 269 bcmATP-RX 117927936 0 0 0 0 268 bcmATP-TX 117927936 0 0 0 0 267 bcmSTACK 117927936 0 0 0 0 266 bcmRX 117927936 0 0 0 0 265 bcmLINK.0 117927936 0 0 0 0 !----------- output truncated --------------! 90488 0 0 0 0 0 0 0 0 show software ifm Display interface management (IFM) data.
• Command History EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.
Parameters brief (OPTIONAL) Enter the keyword brief to view an abbreviated list of system information. stack-unit unitid (OPTIONAL) Enter the keywords stack-unit then the stack member ID for information on that stack member. The unit ID range for the S4820T is from 0 to 11. stack-ports status | topology (OPTIONAL) Enter the keywords stack-ports for information about the status or topology of the stack ports. NOTE: This option applies to the S4810 or S4820T system only.
Example (show system stack unit – disabled ports) Example (show system brief) Dell#show system brief Stack MAC : 90:b1:1c:f4:9b:79 Reload-Type : normal-reload] normal-reload [Next boot : -- Stack Info -Unit UnitType Status ReqTyp CurTyp Version Ports ----------------------------------------------------------------------------------0 Management online S6000 S6000 9-4(0-168) 128 1 Member not present 2 Member not present 3 Member not present 4 Member not present 5 Member not present -- Power Supplies -Unit
Burned In MAC No Of MACs : 90:b1:1c:f4:9b:79 : 3 -- Power Supplies -Unit Bay Status Type FanStatus FanSpeed(rpm) -------------------------------------------------------------------------0 0 down UNKNOWN down 0 0 1 up AC up 6600 -- Fan Status -Unit Bay TrayStatus Fan0 Speed Fan1 Speed ----------------------------------------------------------------------------------0 0 up up 7072 up 7021 0 1 up up 7021 up 7123 0 2 up up 7072 up 7021 Speed in RPM Example (S4810) Control and Monitoring -- Unit 1 -Unit Typ
Vendor Id Date Code Country Code Piece Part ID PPID Revision Service Tag Expr Svc Code Auto Reboot Burned In MAC No Of MACs : : : : : : : : : : DL 26092013 CN CN-08YWFG-28298-39Q-0015 A00 24N1VS1 463 414 838 5 disabled 90:b1:1c:f4:9b:79 3 -- Power Supplies -Unit Bay Status Type FanStatus FanSpeed(rpm) -------------------------------------------------------------------------0 0 down UNKNOWN down 0 0 1 up AC up 6600 -- Fan Status -Unit Bay TrayStatus Fan0 Speed Fan1 Speed ----------------------------------
Unit Bay Status Type FanStatus FanSpeed(rpm) -------------------------------------------------------------------------1 1 up AC up 18528 1 2 absent absent 0 -- Fan Status -Unit Bay TrayStatus Fan1 Speed Fan2 Speed ----------------------------------------------------------------------------------1 1 up up 19275 up 19275 1 2 absent 1 3 up up 19275 up 18904 Speed in RPM Related Commands • show version – displays the Dell Networking OS version.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced save to the file options. 7.6.1.0 Introduced on the S-Series. Without the page or stack-unit option, the command output is continuous. To interrupt the command output, use Ctrl-z. The save option works with other filtering commands.
| Pipe through a command Dell#show tech-support stack-unit 1 | ? except Show only text that does not match a pattern find Search for the first occurrence of a pattern grep Show only text that matches a pattern no-more Don't paginate output save Save output to a file Dell#show tech-support stack-unit 1 | save ? flash: Save to local file system (flash://filename (max 20 chars) ) Dell#show tech-support stack-unit 1 | save flash://LauraSave Start saving show command report .......
redundancy disable-auto-reboot ! redundancy disable-auto-reboot redundancy disable-auto-reboot redundancy disable-auto-reboot redundancy disable-auto-reboot redundancy disable-auto-reboot redundancy disable-auto-reboot ! hardware watchdog stack-unit 0 hardware watchdog stack-unit 1 hardware watchdog stack-unit 2 hardware watchdog stack-unit 3 hardware watchdog stack-unit 4 hardware watchdog stack-unit 5 ! Related Commands stack-unit stack-unit stack-unit stack-unit stack-unit stack-unit stack-unit 0 1 2 3
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.3.11.1 Introduced on the S-Series. telnet Connect through Telnet to a server. The Telnet client and server in Dell Networking support IPv4 and IPv6 connections. You can establish a Telnet session directly to the router or a connection can be initiated from the router. NOTE: The Telnet server and client are VRF-aware.
• For Tunnel interface types, enter the keyword tunnel then the slot/ port information. The range is from 1 to 16383. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Defaults Not configured. Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
In case there is a mismatch between the VRF telnet source interface and the telent VRF, then an error is reported. Example Dell#telnet vrf vrf1 10.10.10.2 telnet-peer-stack-unit Open a Telnet connection to the peer stack unit. Syntax telnet-peer-stack-unit Defaults Not configured. Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Defaults 24 lines Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.
• 30 hops max • 40 byte packet size • UDP port = 33434 Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.
----------------------------------------------TTL Hostname Probe1 Probe2 Probe3 1 10.11.199.190 001.000 ms 001.000 ms 002.000 ms 2 gwegress-sjc-02.Dell Networking.com (10.11.30.126) 005.000 ms 001.000 ms 001.000 ms 3 fw-sjc-01.Dell Networking.com (10.11.127.254) 000.000 ms 000.000 ms 000.000 ms 4 www.Dell Networking.com (10.11.84.18) 000.000 ms 000.000 ms 000.000 ms FTOS# Example (IPv6) Dell#traceroute 100::1 Type Ctrl-C to abort.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command virtual-ip Configure a virtual IP address for the active management interface. You can configure virtual addresses both for IPv4 and IPv6 independently.
Version Description 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.5.1.0 Introduced on the C-Series. E-Series Original command. Usage Information You can configure both IPv4 and IPv6 virtual addresses simultaneously, but only one of each. Each time this command is issued, it replaces the previously configured address of the same family, IPv4 or IPv6.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command. Usage Information The write memory command saves the running-configuration to the file labeled startup-configuration.
5 802.1ag 802.1ag is available on the Dell Networking OS. ccm disable Disable continuity check message (CCM). Syntax ccm disable Enter no ccm disable to enable CCM. Defaults Disabled Command Modes ECFM DOMAIN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.
Defaults 10 seconds Command Modes ECFM DOMAIN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description Version 8.3.19.0 Introduced on the S4820T. Version 8.3.11.1 Introduced on the Z9000. Version 8.3.7.0 Introduced on the S4810. Version 8.3.1.0 Introduced on the S-Series.
database hold-time Set the amount of time that data from a missing MEP is kept in the continuity check database. Syntax Parameters database hold-time minutes minutes Enter a hold-time. The range is from 100 to 65535 minutes. Defaults 100 minutes Command Modes ECFM DOMAIN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the S-Series. domain Create the maintenance domain. Syntax Parameters domain name md-level number name Name the maintenance domain. md-level number Enter a maintenance domain level. The range is from 0 to 7. Defaults none Command Modes ETHERNET CFM Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the S-Series. ethernet cfm mep Create an MEP.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the S-Series. ethernet cfm mip Create a maintenance intermediate point (MIP). Syntax Parameters ethernet cfm mip domain {name | level} ma-name name domain [name | level] Enter the keyword domain then the domain name or domain level. ma-name name Enter the keyword ma-name then the name of the maintenance association.
mep cross-check Enable cross-checking for a MEP. Syntax Parameters mep cross-check mep-id mep-id Enter the MEP ID. The range is from 1 to 8191. Defaults none Command Modes ECFM DOMAIN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the S-Series. mep cross-check start-delay Configure the amount of time the system waits for a remote MEP to come up before the cross-check operation is started. Syntax Parameters mep cross-check start-delay number start-delay number Enter a start-delay in seconds. The range is from 3 to 100 seconds.
Parameters name | level Enter the domain name or level. ma-name maname Enter the keyword ma-name and then enter the maintenance association name. dest-mep-id Enter the MEP ID that is the target of the ping. mac-addr mac-address Enter the keyword mac-addr and then enter the MAC address that is the target of the ping. src-mep-id Enter the MEP ID that originates the ping. port interface Enter the keyword port and then enter the interface that originates the ping.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the S-Series.
Example Version Description Version 8.3.7.0 Introduced on the S4810. Version 8.3.1.0 Introduced on the S-Series.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description Version 8.3.19.0 Introduced on the S4820T. Version 8.3.7.0 Introduced on the S4810. Version 8.3.1.0 Introduced on the S-Series.
show ethernet cfm statistics Display MEP statistics. Syntax Parameters show ethernet cfm statistics [domain {name | level} vlan-id vlan-id mpid mpid] domain Enter the keyword domain to display statistics for a particular domain. name | level Enter the domain name or level. vlan-id vlan-id Enter the keyword vlan-id then a VLAN ID. mpid mpid Enter the keyword mpid then a maintenance point ID. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific.
show ethernet cfm port-statistics Display CFM statistics by port. Syntax Parameters show ethernet cfm port-statistics [interface type slot/port[]] interface type Enter the keyword interface then the interface type. slot/port[] Enter the slot and port numbers for the port. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Example Version Description Version 8.3.7.0 Introduced on the S4810. Version 8.3.1.0 Introduced on the S-Series.
traceroute cache hold-time Set the amount of time a trace result is cached. Syntax Parameters traceroute cache hold-time minutes minutes Enter a hold-time. The range is from 10 to 65535 minutes. Defaults 100 minutes Command Modes ETHERNET CFM Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the S-Series. traceroute ethernet Send a linktrace message to an MEP. Syntax Parameters traceroute ethernet domain [name | level] ma-name remote {mepid mep-id | mac-addr mac-address} domain name | level Enter the keyword domain then the domain name or level. ma-name maname Enter the keyword ma-name then the maintenance association name.
802.1X 6 An authentication server must authenticate a client connected to an 802.1X switch port. Until the authentication, only extensible authentication protocol over LAN (EAPOL) traffic is allowed through the port to which a client is connected. After authentication is successful, normal traffic passes through the port. The Dell Networking operating software supports remote authentication dial-in service (RADIUS) and active directory environments using 802.1X Port Authentication.
debug dot1x Display 802.1X debugging information. Syntax Parameters debug dot1x [all | auth-pae-fsm | backend-fsm | eapol-pdu] [interface interface] all Enable all 802.1X debug messages. auth-pae-fsm Enable authentication PAE FSM debug messages. backend-fsm Enable backend FSM debug messages. eapol-pdu Enable the EAPOL frame trace and related debug messages. interface interface Restricts the debugging information to an interface.
Parameters vlan-id Enter the VLAN Identifier. The range is from 1 to 4094. max-attempts number (OPTIONAL) Enter the keywords max-attempts followed number of attempts desired before authentication fails. The range is from 1 to 5. The default is 3. Defaults 3 attempts Command Modes CONFIGURATION (conf-if-interface-slot/port) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
dot1x auth-server Configure the authentication server to RADIUS. Syntax dot1x auth-server radius Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.4.2.1 Introduced on the C-Series and S-Series. The prerequisites for enabling MAB-only authentication on a port are: • Enable 802.1X authentication globally on the switch and on the port (the dot1x authentication command).
Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series TeraScale. dot1x authentication (Interface) — Enables dot1x on an interface. dot1x authentication (Interface) Enable dot1x on an interface.
Related Commands Version Description 7.4.1.0 Introduced on the E-Series. dot1x authentication (Configuration) — Enables dot1x globally. dot1x guest-vlan Configure a guest VLAN for limited access users or for devices that are not 802.1X capable. Syntax dot1x guest-vlan vlan-id To disable the guest VLAN, use the no dot1x guest-vlan vlan-id command. Parameters vlan-id Enter the VLAN Identifier. The range is from 1 to 4094. Defaults Not configured.
If the host fails authentication for the designated number of times, the authenticator places the port in authentication failed VLAN (dot1x auth-failvlan). NOTE: You can create the Layer 3 portion of a guest VLAN and authentication fail VLANs regardless if the VLAN is assigned to an interface or not. After an interface is assigned a guest VLAN (which has an IP address), routing through the guest VLAN is the same as any other traffic. However, the interface may join/leave a VLAN dynamically.
Usage Information Related Commands Version Description 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Added the multi-auth option on the C-Series and SSeries. 8.3.2.0 Added the single-host and multi-host options on the C-Series, E-Series, and S-Series. • Single-host mode authenticates only one host per authenticator port and drops all other traffic on the port. • Multi-host mode authenticates the first host to respond to an Identity Request and then permits all other traffic on the port.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Introduced on the C-Series and S-Series. To disable MAC authentication bypass on a port, enter the no dot1x mac-authbypass command. dot1x max-eap-req Configure the maximum number of times an extensive authentication protocol (EAP) request is transmitted before the session times out. Syntax dot1x max-eap-req number To return to the default, use the no dot1x max-eap-req command.
dot1x max-supplicants Restrict the number of supplicants that can be authenticated and permitted to access the network through the port. This configuration is only takes effect in Multi-auth mode. Syntax Parameters dot1x max-supplicants number number Enter the number of supplicants that can be authenticated on a single port in Multi-auth mode. The range is from 1 to 128. The default is 128. Defaults 128 hosts can be authenticated on a single authenticator port.
auto Enter the keyword auto to authorize a port based on the 802.1X operation result. forceunauthorized Enter the keywords force-unauthorized to forcibly deauthorize a port. Defaults none Command Modes Auto Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.
Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 7.6.1.
Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x reauth-max Configure the maximum number of times a port can re-authenticate before the port becomes unauthorized.
Version Description 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x server-timeout Configure the amount of time after which exchanges with the server time-out. Syntax dot1x server-timeout seconds To return to the default, use the no dot1x server-timeout command. Parameters seconds Enter a time-out value in seconds. The range is from 1 to 300, where 300 is implementation dependant. The default is 30.
server-timeout seconds > (radius-server retransmit seconds + 1) * radius-server timeout seconds. Where the default values are as follows: dot1x server-timeout (30 seconds), radius-server retransmit (3 seconds), and radius-server timeout (5 seconds). Example Dell(conf)#radius-server host 10.11.197.105 timeout 6 Dell(conf)#radius-server host 10.11.197.
dot1x tx-period Configure the intervals at which EAPOL PDUs the Authenticator PAE transmits. Syntax dot1x tx-period seconds To return to the default, use the no dot1x tx-period command. Parameters seconds Enter the interval time, in seconds, that EAPOL PDUs are transmitted. The range is from 1 to 65535. The default is 30. Defaults 30 seconds Command Modes INTERFACE Command History This guide is platform-specific.
mac-address • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. (Optional) MAC address of an 802.1X-authenticated supplicant. Defaults none Command Modes • EXEC • EXEC privilege Command History This guide is platform-specific.
Dell#show dot1x cos-mapping interface tengigabitethernet 1/32 mac-address 00:00:00:00:00:10 Supplicant Mac: 0 0 0 0 0 10 Lookup for Mac: 802.1p CoS re-map table on Te 0/32: ---------------------------------802.1p CoS re-map table for Supplicant: 00:00:00:00:00:10 Dot1p 0 1 2 3 4 5 6 7 Dell# Remapped Dot1p 7 6 5 4 3 2 1 0 show dot1x interface Display the 802.1X configuration of an interface.
Version Description 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.4.2.1 Added the mac-address option on the C-Series and SSeries. 7.6.1.0 Introduced on the C-Series, E-Series, and S-Series. Usage Information If you enable 802.1X multi-supplicant authentication on a port, additional 802.
Guest VLAN id: Auth-Fail VLAN: Auth-Fail VLAN id: Auth-Fail Max-Attempts: Mac-Auth-Bypass: Mac-Auth-Bypass Only: Tx Period: Quiet Period: ReAuth Max: Supplicant Timeout: Server Timeout: Re-Auth Interval: Max-EAP-Req: Host Mode: Max-Supplicants: 100 Disable NONE NONE Enable Enable 3 seconds 60 seconds 2 30 seconds 30 seconds 3600 seconds 2 MULTI_AUTH 128 Port status and State info for Supplicant: 00:00:00:00:00:10 Port Auth Status: Untagged VLAN id: Auth PAE State: Backend State: Dell# AUTHORIZED(MAC-AUTH
Dot1x Status: Port Control: Re-Authentication: Guest VLAN: Guest VLAN id: Auth-Fail VLAN: Auth-Fail VLAN id: Auth-Fail Max-Attempts: Mac-Auth-Bypass: Mac-Auth-Bypass Only: Tx Period: Quiet Period: ReAuth Max: Supplicant Timeout: Server Timeout: Re-Auth Interval: Max-EAP-Req: Host Mode: Max-Supplicants: Enable AUTO Disable Enable 100 Disable NONE NONE Enable Enable 3 seconds 60 seconds 2 30 seconds 30 seconds 3600 seconds 2 MULTI_AUTH 128 Port status and State info for Supplicant: 00:00:00:00:00:10 Port Au
Access Control Lists (ACL) 7 Access control lists (ACLs) are supported by the Dell Networking OS.
NOTE: You can use the same sequence number for the remark and an ACL rule. description Defaults Command Modes Command History Enter a description of up to 80 characters. Not configured. • • • • CONFIGURATION-STANDARD-ACCESS-LIST CONFIGURATION-EXTENDED-ACCESS-LIST CONFIGURATION-MAC ACCESS LIST-STANDARD CONFIGURATION-MAC ACCESS LIST-EXTENDED This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Related Commands show config — displays the current ACL configuration. show config Display the current ACL configuration. Syntax show config Command Modes • CONFIGURATION-STANDARD-ACCESS-LIST • CONFIGURATION-EXTENDED-ACCESS-LIST Command History • CONFIGURATION-MAC ACCESS LIST-STANDARD • CONFIGURATION-MAC ACCESS LIST-EXTENDED This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Common IP ACL Commands The following commands are available within both Ingress and Egress IP ACL modes (Standard and Extended) and do not have mode-specific options. When an ACL is created without a rule and then is applied to an interface, ACL behavior reflects an implicit permit. The platform supports both Ingress and Egress IP ACLs. NOTE: Also refer to the Commands Common to all ACL Types section. access-class Apply a standard ACL to a terminal line.
Usage Information Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. When you use the access-class access-list-name command without specifying the ipv4 or ipv6 attribute, both IPv4 as well as IPv6 rules that are defined in that ACL are applied to the terminal. This method is a generic way of configuring access restrictions.
Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Increase the name string to accept up to 140 characters. Prior to 7.8.1.0, names were up to 16 characters long. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series.
NOTE: When you specify a single VRF, use the name of the VRF instead of the VRF ID number. Use the VRF ID numbers only when you specify a range of VRFs. Defaults Not enabled. Command Modes INTERFACE/VRF MODE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
ip access-list extended — configures an extended ACL. ip control-plane egress-filter Enable egress Layer 3 ACL lookup for IPv4 CPU traffic. Syntax ip control-plane egress-filter Defaults Not enabled. Command Modes EXEC Privilege Command History Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
seq 15 permit 30.1.2.0/24 Dell# Standard IP ACL Commands When you create an ACL without any rule and then apply it to an interface, the ACL behavior reflects an implicit permit. The platform supports both Ingress and Egress IP ACLs. NOTE: Also refer to the Commands Common to all ACL Types and Common IP ACL Commands sections. deny To drop packets with a certain IP address, configure a filter.
host ip-address Enter the keyword host and then enter the IP address to specify a host IP address only. no-drop Enter the keywords no-drop to match only the forwarded packets. Defaults Not configured. Command Modes CONFIGURATION-STANDARD-ACCESS-LIST Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
permit — configures a permit filter. ip access-list standard Create a standard IP access list (IP ACL) to filter based on IP address. Syntax ip access-list standard access-list-name To delete an access list, use the no ip access-list standard accesslist-name command. Parameters access-listname Enter a string up to 140 characters long as the ACL name. Defaults All IP access lists contain an implicit “deny any,” that is, if no match occurs, the packet is dropped.
The number of entries allowed per ACL is hardware-dependent. For detailed specifications on entries allowed per ACL, refer to your line card documentation. Example Dell(conf)#ip access-list standard TestList Dell(config-std-nacl)# Related Commands ip access-list extended — creates an extended access list. show config — displays the current configuration. permit To permit packets from a specific source IP address to leave the switch, configure a filter.
no-drop Enter the keywords no-drop to match only the forwarded packets. Defaults Not configured. Command Modes CONFIGURATION-STANDARD-ACCESS-LIST Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Added the no-drop parameter. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.
resequence access-list Re-assign sequence numbers to entries of an existing access-list. Syntax Parameters resequence access-list {ipv4 | ipv6 | mac} {access-list-name StartingSeqNum Stepto-Increment} ipv4 | ipv6 | mac Enter the keyword ipv4or mac to identify the access list type to resequence. access-listname Enter the name of a configured IP access list. StartingSeqNu m Enter the starting sequence number to resequence. The range is from 0 to 4294967290.
Usage Information When you have exhausted all the sequence numbers, this feature permits reassigning a new sequence number to entries of an existing access-list. resequence prefix-list ipv4 Re-assign sequence numbers to entries of an existing prefix list. Syntax Parameters resequence prefix-list ipv4 {prefix-list-name StartingSeqNum Step-to-increment} prefix-listname Enter the name of the configured prefix list, up to 140 characters long.
seq Assign a sequence number to a deny or permit filter in an IP access list while creating the filter. Syntax seq sequence-number {deny | permit} {source [mask] | any | host ip-address}} [count [bytes]] [dscp value] [order] [fragments] [no-drop] To delete a filter, use the no seq sequence-number command. Parameters sequencenumber Enter a number from 0 to 4294967290. The range is from 0 to 65534. deny Enter the keyword deny to configure a filter to drop packets meeting this condition.
Defaults Not configured Command Modes CONFIGURATION-STANDARD-ACCESS-LIST Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Related Commands Version Description 9.8(0.0) Added the no-drop parameter. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Extended IP ACL Commands When an ACL is created without any rule and then applied to an interface, ACL behavior reflects an implicit permit. The following commands configure extended IP ACLs, which in addition to the IP address, also examine the packet’s protocol type. The platform supports both Ingress and Egress IP ACLs. NOTE: Also refer to the Commands Common to all ACL Types and Common IP ACL Commands sections. deny Configure a filter that drops IP packets meeting the filter criteria.
count (OPTIONAL) Enter the keyword count to count packets that the filter processes. byte (OPTIONAL) Enter the keyword byte to count bytes that the filter processes. log (OPTIONAL, E-Series only) Enter the keyword log to enter ACL matches in the log. dscp (OPTIONAL) Enter the keyword dcsp to match to the IP DCSCP values. order (OPTIONAL) Enter the keyword order to specify the QoS priority for the ACL entry.
Usage Information Version Description 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added support for the noncontiguous mask and added the monitor option. 6.5.1.0 Expanded to include the optional QoS order priority for the ACL entry. The order option is relevant in the context of the Policy QoS feature only.
• Parameters Use the no deny icmp {source mask | any | host ip-address} {destination mask | any | host ip-address} command. source Enter the IP address of the network or host from which the packets were sent. mask Enter a network mask in /prefix format (/x) or A.B.C.D. The mask, when specified in A.B.C.D format, may be either contiguous or non-contiguous. any Enter the keyword any to specify that all routes are subject to the filter.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Added the keyword dscp. 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs. 8.1.1.0 Introduced on the E-Series ExaScale. 7.4.1.0 Added support for non-contiguous mask and added the monitor option. 6.5.1.0 Expanded to include the optional QoS order priority for the ACL entry.
host ip-address Enter the keyword host then the IP address to specify a host IP address. dscp Enter this keyword dscp to deny a packet based on the DSCP value. The range is from 0 to 63.
numbers have a higher priority) If you did not use the keyword order, the ACLs have the lowest order by default (255). fragments Enter the keyword fragments to use ACLs to control packet fragments. no-drop Enter the keywords no-drop to match only the forwarded packets. Defaults Not configured. Command Modes CONFIGURATION-EXTENDED-ACCESS-LIST Command History This guide is platform-specific.
The C-Series and S-Series cannot count both packets and bytes; when you enter the count byte options, only bytes are incremented. NOTE: When you configure ACL logging and byte counters simultaneously, byte counters may display an incorrect value. Configure packet counters with logging instead. Most ACL rules require one entry in the CAM. However, rules with TCP and UDP port operators (for example, gt, lt, or range) may require more than one entry.
• Parameters Use the no deny udp {source mask | any | host ip-address} {destination mask | any | host ip-address} command. source Enter the IP address of the network or host from which the packets were sent. mask Enter a network mask in /prefix format (/x) or A.B.C.D. The mask, when specified in A.B.C.D format, may be either contiguous or non-contiguous. any Enter the keyword any to specify that all routes are subject to the filter.
no-drop Enter the keywords no-drop to match only the forwarded packets. Defaults Not configured. Command Modes CONFIGURATION-EXTENDED-ACCESS-LIST Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Added the no-drop parameter. 9.7(0.
Most ACL rules require one entry in the CAM. However, rules with TCP and UDP port operators (for example, gt, lt or range) may require more than one entry. The range of ports is configured in the CAM based on bit mask boundaries; the space required depends on exactly what ports are included in the range. Example An ACL rule with a TCP port range of 4000–8000 uses eight entries in the CAM.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.10.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names were up to 16 characters long. 7.6.1.
mask (OPTIONAL) Enter a network mask in /prefix format (/x) or A.B.C.D. The mask, when specified in A.B.C.D format, may be either contiguous or non-contiguous. any Enter the keyword any to specify that all routes are subject to the filter. host ip-address Enter the keyword host then the IP address to specify a host IP address or hostname. destination Enter the IP address of the network or host to which the packets are sent.
Usage Information Version Description 8.3.1.0 Add the DSCP value for ACL matching. 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added support for the non-contiguous mask and added the monitor option. 6.5.10 Expanded to include the optional QoS order priority for the ACL entry.
mask Enter a network mask in /prefix format (/x) or A.B.C.D. The mask, when specified in A.B.C.D format, may be either contiguous or non-contiguous. any Enter the keyword any to specify that all routes are subject to the filter. host ip-address Enter the keyword host then the IP address to specify a host IP address.
byte (OPTIONAL) Enter the keyword byte to count bytes the filter processes. order (OPTIONAL) Enter the keyword order to specify the QoS priority for the ACL entry. The range is from 0 to 254 (where 0 is the highest priority and 254 is the lowest; lower-order numbers have a higher priority). If you do not use the keyword order, the ACLs have the lowest order by default (255). fragments Enter the keyword fragments to use ACLs to control packet fragments.
Usage Information The order option is relevant in the context of the Policy QoS feature only. For more information, refer to the “Quality of Service” chapter of the Dell Networking OS Configuration Guide. NOTE: When you configure ACL logging and byte counters simultaneously, byte counters may display an incorrect value. Configure packet counters with logging instead. The S-Series cannot count both packets and bytes; when you enter the count byte options, only bytes increment.
permit udp To pass UDP packets meeting the filter criteria, configure a filter. Syntax permit udp {source mask | any | host ip-address} [operator port [port]] {destination mask | any | host ip-address} [dscp] [operator port [port]] [count [byte] [order] [fragments] [nodrop] To remove this filter, you have two choices: Parameters 256 • Use the no seq sequence-number command if you know the filter’s sequence number.
order (OPTIONAL) Enter the keyword order to specify the QoS priority for the ACL entry. The range is from 0 to 254 (where 0 is the highest priority and 254 is the lowest; lower-order numbers have a higher priority). If you do not use the keyword order, the ACLs have the lowest order by default (255). fragments Enter the keyword fragments to use ACLs to control packet fragments. no-drop Enter the keywords no-drop to match only the forwarded packets. Defaults Not configured.
NOTE: When you configure ACL logging and byte counters simultaneously, byte counters may display an incorrect value. Configure packet counters with logging instead. The S-Series cannot count both packets and bytes; when you enter the count byte options, only bytes increment. The monitor option is relevant in the context of flow-based monitoring only. For more information, refer to Port Monitoring. Most ACL rules require one entry in the CAM.
access-listname Enter the name of a configured IP access list, up to 140 characters. StartingSeqNu m Enter the starting sequence number to resequence. The range is from 0 to 4294967290. Step-toIncrement Enter the step to increment the sequence number. The range is from 1 to 4294967290. Defaults none Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific.
Step-toIncrement Enter the step to increment the sequence number. The range is from 1 to 65535. Defaults none Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version 9.0.2.0 Introduced on the S6000. Version 8.3.11.1 Introduced on the Z9000. Version 8.1.1.
ip-protocolnumber Enter a number from 0 to 255 to filter based on the protocol identified in the IP protocol header. icmp Enter the keyword icmp to configure an ICMP access list filter. ip Enter the keyword ip to configure a generic IP access list. The keyword ip specifies that the access list permits all IP protocols. tcp Enter the keyword tcp to configure a TCP access list filter. udp Enter the keyword udp to configure a UDP access list filter.
log (OPTIONAL, E-Series only) Enter the keyword log to enter ACL matches in the log. Supported on Jumbo-enabled line cards only. dscp (OPTIONAL) Enter the keyword dcsp to match to the IP DCSCP values. order (OPTIONAL) Enter the keyword order to specify the QoS order for the ACL entry. The range is from 0 to 254 (where 0 is the highest priority and 254 is the lowest; lower-order numbers have a higher priority). If you do not use the keyword order, the ACLs have the lowest order by default (255).
Usage Information Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added support for the non-contiguous mask and added the monitor option. Deprecated the keyword established. 6.5.10 Expanded to include the optional QoS order priority for the ACL entry. The monitor option is relevant in the context of flow-based monitoring only. For more information, refer to Port Monitoring.
Common MAC Access List Commands The following commands are available within both MAC ACL modes (Standard and Extended) and do not have mode-specific options. These commands allow you to clear, display, and assign MAC ACL configurations. The platform supports both Ingress and Egress MAC ACLs. The MAC ACL can be applied on Physical, Port-channel and VLAN interfaces. As per the specified rules in the ACL, the traffic on the interface/ VLAN members or Port-channel members will be permitted or denied.
mac access-group Apply a MAC ACL to traffic entering or exiting an interface. The following interface types can be used for VLAN , Physical interface, Port channel interface. Enter into the interface mode and apply the mac acl in the following manner. Syntax Applying MAC Access group on a physical / port channel interfacemac accessgroup access-list-name {in [vlan vlan-range] | out} To delete a MAC access-group, use the no mac access-group mac-listname command.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names are up to 16 characters long. 7.6.1.0 Introduced on the S-Series. 7.5.1.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.
deny To drop packets with a the MAC address specified, configure a filter. Syntax deny {any | mac-source-address [mac-source-address-mask]} [count [byte]] [log] [monitor] To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no deny {any | mac-source-address mac-source-addressmask} command. any Enter the keyword any to specify that all routes are subject to the filter.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added the monitor option. When you use the log option, the CP processor logs detail the packets that match.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names are up to 16 characters long. 7.6.1.
mac-sourceaddress Enter a MAC address in nn:nn:nn:nn:nn:nn format. mac-sourceaddress-mask (OPTIONAL) Specify which bits in the MAC address must match. If no mask is specified, a mask of 00:00:00:00:00:00 is applied (in other words, the filter allows only MAC addresses that match). count (OPTIONAL) Enter the keyword count to count packets processed by the filter. byte (OPTIONAL) Enter the keyword byte to count bytes processed by the filter.
Usage Information When you use the log option, the CP processor logs details about the packets that match. Depending on how many packets match the log entry and at what rate, the CP may become busy as it has to log these packets’ details. NOTE: When you configure the ACL logging and byte counters simultaneously, byte counters may display an incorrect value. Configure packet counters with logging instead. Related Commands deny — configures a MAC ACL filter to drop packets.
in which you are creating the rule is applied to the monitored interface. NOTE: For more information, refer to the “Flow-based Monitoring” section in the Port Monitoring chapter of the Dell Networking OS Configuration Guide. no-drop Enter the keywords no-drop to match only the forwarded packets. Defaults Not configured Command Modes CONFIGURATION-MAC ACCESS LIST-STANDARD Command History This guide is platform-specific.
Extended MAC ACL Commands When an access-list is created without any rule and then applied to an interface, ACL behavior reflects implicit permit. The following commands configure Extended MAC ACLs. The platform supports both Ingress and Egress MAC ACLs. NOTE: For more information, also refer to the Commands Common to all ACL Types and Common MAC Access List Commands sections. deny To drop packets that match the filter criteria, configure a filter.
ethertype operator (OPTIONAL) To filter based on protocol type, enter one of the following Ethertypes: • ev2 - is the Ethernet II frame format • llc - is the IEEE 802.3 frame format • snap - is the IEEE 802.3 SNAP frame format count (OPTIONAL) Enter the keyword count to count packets processed by the filter. byte (OPTIONAL) Enter the keyword byte to count bytes processed by the filter. log (OPTIONAL, E-Series only) Enter the keyword log to log the packets.
Usage Information When you use the log option, the CP processor logs detail the packets that match. Depending on how many packets match the log entry and at what rate, the CP may become busy as it has to log these packets’ details. NOTE: When you configure the ACL logging and byte counters simultaneously, byte counters may display an incorrect value. Configure packet counters with logging instead. Related Commands permit — configures a MAC address filter to pass packets.
Usage Information Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. The number of entries allowed per ACL is hardware-dependent. For detailed specifications about entries allowed per ACL, refer to your line card documentation. Prior to 7.8.1.0, names are up to 16 characters long.
Parameters • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no permit {any | host mac-address | mac-source-address mac-source-address-mask} {any | mac-destination-address macdestination-address-mask} command. any Enter the keyword any to forward all packets. host Enter the keyword host then a MAC address to forward packets with that host address. mac-sourceaddress Enter a MAC address in nn:nn:nn:nn:nn:nn format.
NOTE: For more information, refer to the Flow-based Monitoring section in the Port Monitoring chapter of the Dell Networking OS Configuration Guide. Defaults Not configured. Command Modes CONFIGURATION-MAC ACCESS LIST-EXTENDED Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
address | mac-destination-address mac-destination-address-mask} [ethertype operator] [count [byte]] [log] [monitor] [no-drop] To delete a filter, use the no seq sequence-number command. Parameters sequencenumber Enter a number as the filter sequence number. The range is from zero (0) to 65535. deny Enter the keyword deny to drop any traffic matching this filter. permit Enter the keyword permit to forward any traffic matching this filter. any Enter the keyword any to filter all packets.
in which you are creating the rule is applied to the monitored interface. NOTE: For more information, refer to the Flow-based Monitoring section in the Port Monitoring chapter of the Dell Networking OS Configuration Guide. no-drop Enter the keywords no-drop to match only the forwarded packets. Defaults Not configured. Command Modes CONFIGURATION-MAC ACCESS LIST-STANDARD Command History This guide is platform-specific.
IP Prefix List Commands When you create an access-list without any rule and then apply it to an interface, the ACL behavior reflects implicit permit. To configure or enable IP prefix lists, use these commands. clear ip prefix-list Reset the number of times traffic mets the conditions (“hit” counters) of the configured prefix lists.
deny To drop packets meeting the criteria specified, configure a filter. Syntax deny ip-prefix [ge min-prefix-length] [le max-prefix-length] To delete a drop filter, use the no deny ip-prefix command. Parameters ip-prefix Specify an IP prefix in the network/length format. For example, 35.0.0.0/ 8 means match the first 8 bits of address 35.0.0.0. ge min-prefixlength (OPTIONAL) Enter the keyword ge and then enter the minimum prefix length, which is a number from zero (0) to 32.
If you do not use the ge or le options, only packets with an exact match to the prefix are filtered. ip prefix-list Enter the PREFIX-LIST mode and configure a prefix list. Syntax ip prefix-list prefix-name To delete a prefix list, use the no ip prefix-list prefix-name command. Parameters prefix-name Enter a string up to 16 characters long as the name of the prefix list, up to 140 characters long. Command Modes CONFIGURATION Command History This guide is platform-specific.
permit Configure a filter that passes packets meeting the criteria specified. Syntax permit ip-prefix [ge min-prefix-length] [le max-prefix-length] To delete a forward filter, use the no permit ip-prefix command. Parameters ip-prefix Specify an IP prefix in the network/length format. For example, 35.0.0.0/8 means match the first 8 bits of address 35.0.0.0. ge min-prefixlength (OPTIONAL) Enter the keyword ge and then enter the minimum prefix length, which is a number from zero (0) to 32.
seq — configures a drop or permit filter with a specified sequence number. seq To a deny or permit filter in a prefix list while configuring the filter, assign a sequence number. Syntax seq sequence-number {deny | permit} {any} | [ip-prefix /nn {ge min-prefix-length} {le max-prefix-length}] | [bitmask number] To delete a specific filter, use the no seq sequence-number {deny | permit} {any} | [ip-prefix {ge min-prefix-length} {le maxprefix-length}] | [bitmask number].
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.3.1.0 Added the bit mask option. If you do not use the ge or le options, only packets with an exact match to the prefix are filtered. show config Display the current PREFIX-LIST configurations.
ip prefix-list snickers Dell(conf-nprefixl)# show ip prefix-list detail Display details of the configured prefix lists. Syntax Parameters show ip prefix-list detail [prefix-name] prefix-name (OPTIONAL) Enter a text string as the name of the prefix list, up to 140 characters. Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
show ip prefix-list summary Display a summary of the configured prefix lists. Syntax Parameters show ip prefix-list summary [prefix-name] prefix-name (OPTIONAL) Enter a text string as the name of the prefix list, up to 140 characters. Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Route Map Commands When you create an access-list without any rule and then applied to an interface, the ACL behavior reflects implicit permit. To configure route maps and their redistribution criteria, use the following commands. continue To a route-map entry with a higher sequence number, configure a route-map. Syntax Parameters continue [sequence-number] sequencenumber (OPTIONAL) Enter the route map sequence number. The range is from 1 to 65535. Defaults Not configured.
The continue feature can exist without a match clause. A continue clause without a match clause executes and jumps to the specified route-map entry. With a match clause and a continue clause, the match clause executes first and the continue clause next in a specified route map entry. The continue clause launches only after a successful match.
Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. pre-7.7.1.0 Introduced. route-map — enables a route map. match as-path To match routes that have a certain AS number in their BGP path, configure a filter.
Related Commands Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. set as-path — adds information to the BGP AS_PATH attribute. match community To match routes that have a certain COMMUNITY attribute in their BGP path, configure a filter. Syntax match community community-list-name [exact] To delete a community match filter, use the no match community command.
Related Commands set community — specifies a COMMUNITY attribute. match interface To match routes whose next hop is on the interface specified, configure a filter. Syntax match interface interface To remove a match, use the no match interface interface command. Parameters interface Enter the following keywords and slot/port or number information: • . • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Related Commands Version Description 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. match ip address — redistributes routes that match an IP address. match ip next-hop — redistributes routes that match the next-hop IP address. match ip route-source — redistributes routes that match routes advertised by other routers. match metric — redistributes routes that match a specific metric. match route-type — redistributes routes that match a route type.
Related Commands Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names are up to 16 characters long. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. match interface — redistributes routes that match the next-hop interface. match ip next-hop — redistributes routes that match the next-hop IP address.
Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names are up to 16 characters long. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810 8.1.1.
Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.
incomplete Enter the keyword incomplete to match routes with incomplete routing information. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.
Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.
Defaults permit (OPTIONAL) Enter the keyword permit to set the route map default as permit. If you do not specify a keyword, the default is permit. deny (OPTIONAL) Enter the keyword deny to set the route map default as deny. sequencenumber (OPTIONAL) Enter a number to identify the route map for editing and sequencing with other route maps. You are prompted for a sequence number if there are multiple instances of the route map. The range is from 1 to 65535. Not configured.
set as-path To modify the AS path for border gateway protocol (BGP) routes, configure a filter. Syntax set as-path prepend as-number [... as-number] To remove an AS-Path setting, use the no set as-path {prepend as-number | tag} command. Parameters prepend asnumber Enter the keyword prepend and then enter up to eight AS numbers to be inserted into the BGP path information. The range is from 1 to 65535. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific.
set automatic-tag To automatically compute the tag value of the route, configure a filter. Syntax set automatic-tag To return to the default, enter no set automatic-tag. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
To insert the community list into the COMMUNITY attribute, use the no set comm-list community-list-name delete command. Parameters communitylist-name Enter the name of an established Community list, up to 140 characters. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
set community Allows you to assign a BGP COMMUNITY attribute. Syntax set community {community-number | local-as | no-advertise | noexport | none} [additive] To delete a BGP COMMUNITY attribute assignment, use the no set community {community-number | local-as | no-advertise | no-export | none} command. Parameters communitynumber Enter the community number in AA:NN format where AA is the AS number (2 bytes) and NN is a value specific to that autonomous system.
Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. match community — redistributes routes that match the COMMUNITY attribute.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Dell Networking OS Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.
Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Usage Information The set local-preference command changes the LOCAL_PREF attribute for routes meeting the route map criteria.
Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. set automatic-tag — computes the tag value of the route. set level — specifies the OSPF area for route redistribution.
Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Implemented the keyword internal. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. set automatic-tag — computes the tag value of the route.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. If you configure the set next-hop command, its configuration takes precedence over the neighbor next-hop-self command in the ROUTER BGP mode.
Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. set tag To specify a tag for redistributed routes, configure a filter.
Related Commands Version Description pre-6.1.1.0 Introduced on the E-Series. set automatic-tag — computes the tag value of the route. set level — specifies the OSPF area for route redistribution. set metric — specifies the metric value assigned to redistributed routes. set metric-type — specifies the route type assigned to redistributed routes. set weight To add a non-RFC compliant attribute to the BGP route to assist with route selection, configure a filter.
Usage Information Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. If you do not use the set weight command, router-originated paths have a weight attribute of 32768 and all other paths have a weight attribute of zero. show config Display the current route map configuration. Syntax show config Command Modes ROUTE-MAP Command History This guide is platform-specific.
show route-map Display the current route map configurations. Syntax Parameters show route-map [map-name] map-name (OPTIONAL) Enter the name of a configured route map, up to 140 characters. Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.
AS-Path Commands The following commands configure AS-Path ACLs. ip as-path access-list Enter AS-PATH ACL mode and configure an access control list based on the BGP AS_PATH attribute. Syntax Parameters ip as-path access-list as-path-name as-path-name Enter the access-list name, up to 140 characters. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
show ip as-path-access-lists Display the all AS-PATH access lists configured on the E-Series. Syntax show ip as-path-access-lists Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.
Parameters comm-listname Enter a text string as the name of the community-list, up to 140 characters. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Example Version Description 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names are up to 16 characters long. pre-Version 6.1.1.0 Introduced on the E-Series. Dell#show ip community-lists ip community-list ABC permit local-AS deny no-advertise permit no-export Dell# deny (for Standard IP ACLs) To drop packets with a certain IP address, configure a filter.
Defaults By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled. Command Modes Command History Usage Information CONFIGURATION-STANDARD-ACCESS-LIST Version Description 9.7(0.0) Introduced on the S6000–ON. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. 9.4(0.
deny (for Extended IP ACLs) Configure a filter that drops IP packets meeting the filter criteria. Syntax deny {ip | ip-protocol-number} {source mask | any | host ipaddress} {destination mask | any | host ip-address} [count [byte]] [dscp value] [order] [monitor] [fragments] [log [interval minutes] [threshold-in-msgs [count]] [monitor] To remove this filter, you have two choices: • • Parameters Defaults Use the no seq sequence-number command if you know the filter’s sequence number.
Usage Information When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero. If ACL logging was stopped previously because the configured threshold is exceeded, it is re-enabled for this new interval.
of ACL logs is terminated with the seq, permit, or deny commands. The threshold range is from 1 to 100. Defaults interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes at which ACL logs must be generated. The interval range is from 1 to 10 minutes. monitor (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface.
one port and forwards (mirrors) them to another port. The source port is the monitored port (MD) and the destination port is the monitoring port (MG). Related Commands deny — Configures a filter to drop packets. permit — Configures a filter to forward packets. deny tcp (for Extended IP ACLs) Configure a filter that drops transmission control protocol (TCP) packets meeting the filter criteria.
Command Modes Command History Usage Information CONFIGURATION-EXTENDED-ACCESS-LIST Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added the support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added the support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped.
[operator port [port]] [count [byte]] [order] [fragments] [log [interval minutes] [threshold-in-msgs [count]] To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no deny udp {source mask | any | host ip-address} {destination mask | any | host ip-address} command. log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages.
deny arp (for Extended MAC ACLs) Configure an egress filter that drops ARP packets on egress ACL supported line cards. (For more information, refer to your line card documentation).
Usage Information Version Description 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero.
• Parameters Defaults Use the no deny icmp {source mask | any | host ip-address} {destination mask | any | host ip-address} command. log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages. threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated with the seq, permit, or deny commands.
monitoring only specified traffic instead all traffic on the interface. This feature is particularly useful when looking for malicious traffic. It is available for Layer 2 and Layer 3 ingress and egress traffic. You may specify traffic using standard or extended access-lists. This mechanism copies all incoming or outgoing packets on one port and forwards (mirrors) them to another port. The source port is the monitored port (MD) and the destination port is the monitoring port (MG).
Command Modes Command History Usage Information CONFIGURATION-EXTENDED-ACCESS-LIST Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped.
Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no deny {any | mac-source-address mac-source-addressmask} command. log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages. threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated.
You can activate flow-based monitoring for a monitoring session by entering the flow-based enable command in the Monitor Session mode. When you enable this capability, traffic with particular flows that are traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface.
monitor Defaults (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled.
seq — configures a MAC address filter with a specified sequence number. permit (for Standard IP ACLs) To permit packets from a specific source IP address to leave the switch, configure a filter. Syntax permit {source [mask]| any | host ip-address} [count [byte]] [dscp value] [order] [fragments] [log [interval minutes] [threshold-in-msgs [count]] [monitor] To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number.
Usage Information Version Description 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero.
Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the {destination-mac-address mac-address-mask | any} vlan vlan-id {ip-address | any | opcode code-number} command. log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages.
You can activate flow-based monitoring for a monitoring session by entering the flow-based enable command in the Monitor Session mode. When you enable this capability, traffic with particular flows that are traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface.
Defaults By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled. Command Modes Command History Usage Information CONFIGURATION-EXTENDED-ACCESS-LIST Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.
permit icmp (for Extended IP ACLs) Configure a filter to allow all or specific ICMP messages. Syntax permit icmp {source mask | any | host ip-address} {destination mask | any | host ip-address} [dscp] [message-type] [count [byte]] [order] [fragments] [log [interval minutes] [thresholdin-msgs [count]] [monitor] To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number.
Usage Information When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero. If ACL logging was stopped previously because the configured threshold is exceeded, it is re-enabled for this new interval.
of ACL logs is terminated with the seq, permit, or deny commands. The threshold range is from 1 to 100. Defaults interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes at which ACL logs must be generated. The interval range is from 1 to 10 minutes. monitor (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface.
one port and forwards (mirrors) them to another port. The source port is the monitored port (MD) and the destination port is the monitoring port (MG). Related Commands ip access-list extended — creates an extended ACL. permit — assigns a permit filter for IP packets. permit tcp — assigns a permit filter for TCP packets. permit (for Extended IP ACLs) To pass IP packets meeting the filter criteria, configure a filter.
Command Modes Command History Usage Information CONFIGURATION-EXTENDED-ACCESS-LIST Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added the support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added the support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped.
permit (for Standard MAC ACLs) To forward packets from a specific source MAC address, configure a filter. Syntax permit {any | mac-source-address [mac-source-address-mask]} [count [byte]] | [log [interval minutes] [threshold-in-msgs [count]] [monitor] To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no permit {any | mac-source-address mac-sourceaddress-mask} command.
new interval commences from zero. If ACL logging was stopped previously because the configured threshold is exceeded, it is re-enabled for this new interval. If ACL logging is stopped because the configured threshold is exceeded, it is reenabled after the logging interval period elapses. ACL logging is supported for standard and extended IPv4 ACLs, IPv6 ACLs, and MAC ACLs.
monitor Defaults (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled.
permit — configures a filter to forward packets. permit tcp (for Extended IP ACLs) To pass TCP packets meeting the filter criteria, configure a filter.
Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped.
seq arp (for Extended MAC ACLs) Configure an egress filter with a sequence number that filters ARP packets meeting this criteria. This command is supported only on 12-port GE line cards with SFP optics. For specifications, refer to your line card documentation. NOTE: Only the options that have been newly introduced in Release 9.3(0.0) and Release 9.4(0.0) are described here.
Usage Information Version Description 9.3.0.0 Added support for logging of ACLs on the S4810, S4820T, Z9000, and MXL 10/40GbE Switch IO Module platforms. When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero.
Parameters Defaults log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages. threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated. with the seq, permit, or deny commands. You can enter a threshold in the range of 1-100.
capability, traffic with particular flows that are traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface. This feature is particularly useful when looking for malicious traffic. It is available for Layer 2 and Layer 3 ingress and egress traffic.
Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped.
To delete a filter, use the no seq sequence-number command. Parameters Defaults log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages. threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminate with the seq, permit, or deny commands. The threshold range is from 1 to 100.
this capability, traffic with particular flows that are traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface. This feature is particularly useful when looking for malicious traffic. It is available for Layer 2 and Layer 3 ingress and egress traffic.
Defaults By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled. Command Modes Command History Usage Information ACCESS-LIST Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3.0.
permit tcp (for IPv6 ACLs) Configure a filter to pass TCP packets that match the filter criteria. Syntax permit tcp {source address mask | any | host ipv6-address} [operator port [port]] {destination address | any | host ipv6address} [bit] [operator port [port]] [count [byte]] [log [interval minutes] [threshold-in-msgs [count]] [monitor] To remove this filter, you have two choices: • • Parameters Defaults Use the no seq sequence-number command if you know the filter’s sequence number.
Usage Information When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero. If ACL logging was stopped previously because the configured threshold is exceeded, it is re-enabled for this new interval.
Defaults threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated with the seq, permit, or deny commands. The threshold range is from 1 to 100. interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes at which ACL logs must be generated. The interval range is from 1 to 10 minutes.
Layer 2 and Layer 3 ingress and egress traffic. You may specify traffic using standard or extended access-lists. This mechanism copies all incoming or outgoing packets on one port and forwards (mirrors) them to another port. The source port is the monitored port (MD) and the destination port is the monitoring port (MG). permit (for IPv6 ACLs) To configure a filter that matches the filter criteria, select an IPv6 protocol number, ICMP, IPv6, TCP, or UDP.
Command Modes Command History Usage Information ACCESS-LIST Version Description 9.8(0.0) Added the no-drop parameter. 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped.
Parameters Defaults • Use the no seq sequence-number command syntax if you know the filter’s sequence number • Use the no deny udp {source address mask | any | host ipv6address} {destination address | any | host ipv6-address} command log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages.
You can configure ACL logging only on ACLs that are applied to ingress interfaces; you cannot enable logging for ACLs that are associated with egress interfaces. You can activate flow-based monitoring for a monitoring session by entering the flow-based enable command in the Monitor Session mode.
Defaults By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled. Command Modes Command History Usage Information ACCESS-LIST Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.
deny icmp (for Extended IPv6 ACLs) Configure a filter to drop all or specific ICMP messages. NOTE: Only the options that have been newly introduced in Release 9.3(0.0) and Release 9.4(0.0) are described here. For a complete description on all of the keywords and variables that are available with this command, refer the topic of this command discussed earlier in this guide.
Usage Information Version Description 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3.0.0 Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero.
Parameters Defaults log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages. threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated. with the seq, permit, or deny commands. The threshold range is from 1 to 100.
You can activate flow-based monitoring for a monitoring session by entering the flow-based enable command in the Monitor Session mode. When you enable this capability, traffic with particular flows that are traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface.
8 Access Control List (ACL) VLAN Groups and Content Addressable Memory (CAM) This chapter describes the access control list (ACL) virtual local area network (VLAN) group and content addressable memory (CAM) enhancements. member vlan Add VLAN members to an ACL VLAN group. Syntax Parameters member vlan {VLAN-range} VLAN-range Enter the member VLANs using comma-separated VLAN IDs, a range of VLAN IDs, a single VLAN ID, or a combination.
Attaching an ACL individually to VLAN interfaces is similar to the behavior of ACLVLAN mapping storage in CAM prior to the implementation of the ACL VLAN group functionality. ip access-group Apply an egress IP ACL to the ACL VLAN group. Syntax Parameters ip access-group {group name} out implicit-permit group-name Enter the name of the ACL VLAN group where you want the egress IP ACLs applied, up to 140 characters. out Enter the keyword out to apply the ACL to outgoing traffic.
Without the detail option, the output displays in a table style and information may be truncated. Default No default behavior or values Command Modes EXEC EXEC Privilege Command History Version 9.3. (0.0) Introduced on the S4810, S4820T, Z9000 and MXL platforms Usage Information When an ACL-VLAN-Group name or the Access List Group Name contains more than 30 characters, the name is truncated in the show acl-vlan-group command output.
test Ingress IPV6 Acl : Vlan Members : 1-100 show cam-acl-vlan Display the number of flow processor (FP) blocks that is allocated for the different VLAN services. Syntax show cam-acl-vlan Command Modes EXEC Privilege Command History Usage Information Version 9.3. (0.0) Introduced on the S4810, S4820T, Z9000 and MXL platforms. After CAM configuration for ACL VLAN groups is performed, you must reboot the system to enable the settings to be stored in nonvolatile storage.
Example Field Description VlanAclOpt Number of FP blocks for ACL VLAN optimzation feature. Dell#show cam-acl-vlan -- Chassis Vlan Cam ACL -Current Settings(in block sizes) VlanOpenFlow : 0 VlanIscsi : 0 VlanAclOpt : 2 VlanHp : 1 VlanFcoe : 1 cam-acl-vlan Allocate the number of flow processor (FP) blocks or entries for VLAN services and processes. Syntax Parameters cam-acl-vlan { default | vlanopenflow <0-2> | vlaniscsi <0-2> | vlanaclopt <0-2> default Reset the number of FP blocks to default.
Usage Information The VLAN ContentAware Processor (VCAP) application is a pre-ingress CAP that modifies the VLAN settings before packets are forwarded. To support the ACL CAM optimization functionality, the CAM carving feature is enhanced. A total of four VACP groups are present, of which two are for fixed groups and the other two are for dynamic groups. Out of the total of two dynamic groups, you can allocate zero, one, or two flow processor (FP) blocks to iSCSI Counters, OpenFlow and ACL Optimization.
Example 1: Output of the show camusage Command Field Description LineCard Number of the line card that contains information on ACL VLAN groups Portpipe The hardware path that packets follow through a system for ACL optimization CAM-Region Type of area in the CAM block that is used for ACL VLAN groups Total CAM space Total amount of space in the CAM block Used CAM Amount of CAM space that is currently in use Available CAM Amount of CAM space that is free and remaining to be allocated for ACLs
| 12286 | | 262127 | | 2834 --More-- | IN-L3 FIB | 262141 | 14 | IN-L3-SysFlow | 2878 | 44 Example 2: Output of the show camusage acl Command Dell#show cam-usage acl Stackunit|Portpipe| CAM Partition | Total CAM | CAM |Available CAM ========|========|=================|=============| =============|============== 0 | 0 | IN-L3 ACL | 1024 | 4 | 1020 | | IN-V6 ACL | 512 | 0 | 512 | | IN-L2 ACL | 512 | 6 | 506 | | OUT-L3 ACL | 123 | 5 | 118 | | OUT-V6 ACL | 123 | 0 | 123 | | OUT-L2 ACL | 206 | 7 | 1
| Example 4: Output of the show camusage switch Command 16384 Dell#show cam-usage switch Linecard|Portpipe| CAM Partition | Total CAM | |Available CAM ========|========|=================|=============| =============|============== 11 | 0 | IN-L2 ACL | 7152 | | 7152 | | IN-L2 FIB | 32768 | | 31687 | | OUT-L2 ACL | 0 | | 0 11 | 1 | IN-L2 ACL | 7152 | | 7152 | | IN-L2 FIB | 32768 | | 31687 | | OUT-L2 ACL | 0 | | 0 Used CAM 0 1081 0 0 1081 0 show running config acl-vlan-group Display the running configura
Dell#show running-config acl-vlan-group ! acl-vlan-group Test member vlan 1-100 ip access-group test in Test acl-vlan-group Create an ACL VLAN group. Syntax acl-vlan-group {group name} To remove an ACL VLAN group, use the no acl-vlan-group {group name} command. Parameters group-name Specify the name of the ACL VLAN group. The name can contain a maximum 140 characters. Default No default behavior or values Command Modes CONFIGURATION Command History Usage Information Version 9.3(0.
show acl-vlan-group detail Display all the ACL VLAN Groups or display a specific ACL VLAN Group by name. To display the names in their entirety, the output displays in a line-by-line format. Syntax Parameters show acl-vlan-group detail detail Display information in a line-by-line format to display the names in their entirety. Without the detail option, the output is displayed in a table style and information may be truncated.
description (ACL VLAN Group) Add a description to the ACL VLAN group. Syntax Parameters description description description Enter a description to identify the ACL VLAN group (80 characters maximum). Default No default behavior or values Command Modes CONFIGURATION (conf-acl-vl-grp) Command History Usage Information 384 Version 9.3. (0.
9 Bidirectional Forwarding Detection (BFD) Bidirectional forwarding detection (BFD) is a detection protocol that provides fast forwarding path failure detection.
The default is active. Defaults Refer to Parameters. Command Modes ROUTER OSPF ROUTER OSPFv3 ROUTER BGP ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information 386 Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.2.(0.
neighbor belongs. The neighbors inherit only the global timer values (configured with the bfd neighbor command). You can only enable BFD for VRRP in INTERFACE command mode (vrrp bfd all-neighbors). Related Commands neighbor bfd disable — Explicitly disables a BFD session with a BGP neighbor or a BGP peer group. bfd disable Disable BFD on an interface. S4820T Syntax bfd disable Re-enable BFD using the no bfd disable command. Defaults BFD is disabled by default.
bfd enable (Configuration) Enable BFD on all interfaces. S4820T Syntax bfd enable Disable BFD using the no bfd enable command. Defaults BFD is disabled by default. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.0.0.0 Introduced on the Z9000. 8.3.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. 8.2.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. bfd interval Specify non-default BFD session parameters beginning with the transmission interval.
Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. 8.2.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the C-Series. 7.4.1.
Related Commands Version Description 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. 8.2.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the C-Series. 7.5.1.0 Added support for VLAN and port-channel interfaces on the E-Series. show bfd neighbors — displays the BFD neighbor information on all interfaces or a specified interface. bfd protocol-liveness Enable the BFD protocol liveness feature.
ip route bfd Enable BFD for all neighbors configured through static routes. S4820T Syntax ip route bfd [interval interval min_rx min_rx multiplier value role {active | passive}] To disable BFD for all neighbors configured through static routes, use the no ip route bfd [interval interval min_rx min_rx multiplier value role {active | passive}] command.
Version Description 7.4.1.0 Introduced on the E-Series. ipv6 ospf bfd all-neighbors Establish BFD sessions with all OSPFv3 neighbors on a single interface or use non-default BFD session parameters. S4820T Syntax ipv6 ospf bfd all-neighbors [disable | [interval interval min_rx min_rx multiplier value role {active | passive}]] To disable all BFD sessions on an OSPFv3 interface implicitly, use the no ipv6 ospf bfd all-neighbors disable command in interface mode..
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.2.0.0 Introduced on the Z9000, S4820T, and S4810. This command provides the flexibility to fine-tune the timer values based on individual interface needs when you configure ipv6 ospf BFD in CONFIGURATION mode.
role [active | passive] Enter the role that the local system assumes: • Active — The active system initiates the BFD session. Both systems can be active for the same session. • Passive — The passive system does not initiate a session. It only responds to a request for session initialization from the active system. The default is Active. Defaults See Parameters Command Modes INTERFACE Command History This guide is platform-specific.
Parameters ip-address Enter the IP address of the BGP neighbor that you want to explicitly enable for BFD sessions in dotted decimal format (A.B.C.D). peer-groupname Enter the name of the peer group that you want to explicitly enable for BFD sessions. Defaults none Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
neighbor bfd disable Explicitly disable a BFD session with a BGP neighbor or a BGP peer group. S4820T Syntax Parameters neighbor {ip-address | peer-group-name} bfd disable ip-address Enter the IP address of the BGP neighbor that you want to explicitly disable for BFD sessions in dotted decimal format (A.B.C.D). peer-groupname Enter the name of the peer group that you want to explicitly disable for BFD sessions.
Related Commands neighbor bfd — Explicitly enables a BFD session with a BGP neighbor or a BGP peer group. show bfd neighbors Display BFD neighbor information on all interfaces or a specified interface. S4820T Syntax Parameters show bfd neighbors interface [detail] interface detail Enter one of the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Example Version Description 8.2.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the C-Series. 7.5.1.0 Added support for BFD for VLAN and port-channel interfaces on the E-Series. 7.4.1.0 Introduced BFD on physical ports on the E-Series. Dell#show bfd neighbors * - Active session role Ad Dn - Admin Down B - BGP C - CLI I - ISIS O - OSPF R - Static Route (RTM) LocalAddr Clients * 10.1.3.2 RemoteAddr Interface State Rx-int Tx-int Mult 10.1.3.
vrrp bfd neighbor Establish a BFD for VRRP session with a neighbor. S4820T Syntax vrrp bfd neighbor ip-address To remove the BFD session with the neighbor, use the no vrrp bfd neighbor ip-address command. Parameters ip-address Enter the IP address of the neighbor in dotted decimal format (A.B.C.D). Defaults none Command Modes INTERFACE Command History This guide is platform-specific.
Border Gateway Protocol 10 BGP is an external gateway protocol that transmits interdomain routing information within and between autonomous systems (AS). BGP version 4 (BGPv4) supports classless inter-domain routing (CIDR) and the aggregation of routes and AS paths. Basically, two routers (called neighbors or peers) exchange information including full routing tables and periodically sent messages to update those routing tables. BGP is supported in Dell Networking OS version 8.3.19.
address-family Enable the IPv4 multicast or the IPv6 address family. S4820T Syntax Parameters address-family [ipv4 {multicast | vrf vrf-name} | ipv6 unicast [vrf vrf-name]] ipv4 multicast Enter the keyword ipv4 followed by the keyword multicast to enable BGPv4 multicast mode. ipv4 vrf vrfname Enter the keyword ipv4 followed by the keyword vrf and then the name of the VRF to enable VRF mode.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 6.5.1.0 Introduced aggregate-address To minimize the number of entries in the routing table, summarize a range of prefixes. S4820T Syntax Parameters aggregate-address ip-address mask [advertise-map map-name] [asset] [attribute-map map-name] [summary-only] [suppress-map mapname] ip-address mask Enter the IP address and mask of the route to be the aggregate address.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series.
bgp always-compare-med Allows you to enable comparison of the MULTI_EXIT_DISC (MED) attributes in the paths from different external ASs. S4820T Syntax bgp always-compare-med To disable comparison of MED, enter no bgp always-compare-med. Defaults Disabled (that is, the software only compares MEDs from neighbors within the same AS). Command Modes ROUTER BGP Command History This guide is platform-specific.
Parameters send Enter the keyword send to indicate that the system sends multiple paths to peers. receive Enter the keyword receive to indicate that the system accepts multiple paths from peers. both Enter the keyword both to indicate that the system sends and accepts multiple paths from peers. path-count Enter the number paths supported. The range is from 2 to 64. Defaults Disabled Command Modes • ROUTER BGP • ROUTER BGP-address-family Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.
bgp bestpath as-path ignore Ignore the AS PATH in BGP best path calculations. S4820T Syntax bgp bestpath as-path ignore To return to the default, enter the no bgp bestpath as-path ignore command. Defaults Disabled (that is, the software considers the AS_PATH when choosing a route as best). Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.4 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
Usage Information Version Description 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. The software compares the MEDs only if the path contains no external autonomous system numbers. If you enable this command, use the clear ip bgp * command to recompute the best path. bgp bestpath med missing-as-best During path selection, indicate preference to paths with missing MED (MULTI_EXIT_DISC) over paths with an advertised MED attribute.
bgp bestpath router-id ignore Do not compare router-id information for external paths during best path selection. S4820T Syntax bgp bestpath router-id ignore To return to the default selection, use the no bgp bestpath router-id ignore command. Defaults Disabled Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. When a BGP cluster contains only one route reflector, the cluster ID is the route reflector’s router ID. For redundancy, a BGP cluster may contain two or more route reflectors.
Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
bgp confederation peers Specify the autonomous systems (ASs) that belong to the BGP confederation. S4820T Syntax bgp confederation peers as-number [...as-number] To return to the default, use the no bgp confederation peers command. Parameters as-number Enter the AS number. The range is from 0 to 65535 (2 byte), from 1 to 4294967295 (4 byte), or from 0.1 to 65535.65535 (dotted format). ...as-number (OPTIONAL) Enter up to 16 confederation numbers.
Related Commands bgp confederation identifier — configures a confederation ID. bgp four-octet-as-support — enables 4-byte support for the BGP process. bgp dampening Enable BGP route dampening and configure the dampening parameters. S4820T Syntax bgp dampening [half-life reuse suppress max-suppress-time] [route-map map-name] To disable route dampening, use the no bgp dampening [half-life reuse suppress max-suppress-time] [route-map map-name] command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.
Usage Information Configuring or un-configuring the command will bring down and bring up the BGP Route Manager, this will result in tear down and re-establishment of all active sessions. Link Bandwidth has to be configured on the router in order to tell it to associate Link Bandwidth with prefixes (paths) and/or to use Link Bandwidth in BGP Multipath route selection. This is done under BGP configuration and is supported per address family – for IPv4 and IPv6 address families.
Usage Information Version Description 7.4.1.0 Introduced. This command is enabled by default, that is for all updates received from EBGP peers, BGP ensures that the first AS of the first AS segment is always the AS of the peer. If not, the update is dropped and a counter is increments. Use the show ip bgp neighbors command to view the “failed enforce-first-as check” counter. If you disable the enforce-first-as command, it can be viewed using the show ip protocols command.
Usage Information Version Description 7.7.1.0 Introduced on the C-Series. The bgp fast-external-fallover command appears in the show config command output. The fast external fallover configuration is applied only after you manually reset all the existing BGP sessions. As a result, after you execute this command, you must also manually execute the clear ip bgp command in order for the configuration to take effect. bgp four-octet-as-support Enable 4-byte support for the BGP process.
When creating Confederations, all the routers in the Confederation must be 4 byte or 2 byte identified routers. You cannot mix them. Where the 2-byte format is from 1 to 65535, the 4-byte format is from 1 to 4294967295. Both formats are accepted and the advertisements reflect the entered format. For more information about using the 2 byte or 4-byte format, refer to the Dell Networking OS Configuration Guide. This command automatically restarts the BGP instance for the configuration to take effect.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. This feature is advertised to BGP neighbors through a capability advertisement. In Receiver Only mode, BGP saves the advertised routes of peers that support this capability when they restart. BGP graceful restart is active only when the neighbor becomes established.
Usage Information Version Description 7.7.1.0 Introduced on the C-Series. In Non-Deterministic mode, paths are compared in the order in which they arrive. This method can lead to Dell Networking OS choosing different best paths from a set of paths, depending on the order in which they are received from the neighbors because MED may or may not get compared between adjacent paths.
Usage Information This command is a knob to disable BGP next-hop resolution using BGP learned routes. During the next-hop resolution, only the first route that the next-hop resolves through is verified for the route’s protocol source and is checked if the route is learned from BGP or not. The clear ip bgp command is required for this command to take effect and to keep the BGP database consistent. Execute the clear ip bgp command right after executing this command.
regular expressions can be quite CPU intensive, as a regular expression evaluation involves generation and evaluation of complex finite state machines. BGP policies, containing regular expressions to match as-path and communities, tend to use much CPU processing time, which in turn affects the BGP routing convergence. Additionally, the show bgp commands, which are filtered through regular expressions, use up CPU cycles particularly with large databases.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series.
A.B.C.D Enter the BGP neighbor address in the A.B.C.D format to clear. X:X:X:X::X Enter the BGP neighbor address in the X:X:X:X::X format to clear. soft (OPTIONAL) Enter the keyword soft to configure and activate policies without resetting the BGP TCP session, that is, BGP Soft Reconfiguration. NOTE: If you enter the clear ip bgp ip-address soft command, both inbound and outbound policies are reset. in (OPTIONAL) Enter the keyword in to activate only inbound policies.
Related Commands Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 6.5.1.0 Expanded to include the as-number option. bgp recursive-bgp-next-hop — disables next-hop resolution through other routes learned by the BGP. clear ip bgp dampening Clear information on route dampening and return the suppressed route to the Active state.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
ipv6 unicast (OPTIONAL) Enter the keyword ipv6 followed by the keyword unicast to clear information related only to ipv6 unicast routes. ipv4-address mask (OPTIONAL) Enter an IPv4 address in dotted decimal format and the prefix mask in slash format (/x) to reset only that prefix. ipv6–address mask (OPTIONAL) Enter the IPv6 address followed by the network mask to reset only that prefix. filter-list aspath-name (OPTIONAL) Enter the keywords filter-list then the name of a configured AS-PATH list.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Usage Information If you enter the clear ip bgp flap-statistics command without any parameters, all statistics are cleared. Related Commands show debugging — views the enabled debugging operations. show ip bgp flap-statistics — views the BGP flap statistics. undebug all — disables all debugging operations.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 9.4.(0.0) Added support for VRF. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
A.B.C.D Enter the IP address of peer in the A.B.C.D format. X:X:X:X::X Enter the IPv6 IP address of peer in the X:X:X:X::X format. dampening Enter the keyword dampening to view BGP dampening. events Enter the keyword events to view BGP protocol events. ipv4 Enter the ipv4 IP address to view the IPV4 route information. ipv6 Enter the ipv6 IP address to view the IPV6 route information. keepalives Enter the keyword keepalives to view BGP keepalives.
Related Commands debug ip bgp events — views information about BGP events. debug ip bgp keepalives — views information about BGP keepalives. debug ip bgp notifications — views information about BGP notifications. debug ip bgp updates — views information about BGP updates. show debugging — views enabled debugging operations. debug ip bgp dampening View information on routes being dampened.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.6.1.0 Introduced IPv6 MGBP support for the E-Series. debug ip bgp events Display information on local BGP state changes and other BGP events. S4820T Syntax debug ip bgp [vrf vrf-name] [A.B.C.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. To remove all configured debug commands for BGP, enter the no debug ip bgp command. debug ip bgp keepalives Display information about BGP keepalive messages. S4820T Syntax debug ip bgp [vrf vrf-name] [A.B.C.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added ipv6 support. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
in (OPTIONAL) Enter the keyword in to view only BGP updates received from neighbors. out (OPTIONAL) Enter the keyword out to view only BGP updates sent to neighbors. prefix-list prefix-listname (OPTIONAL) Enter the keyword prefix-list then the name of an established prefix list. If the prefix list is not configured, the default is permit (to allow all routes). ip-address (OPTIONAL) Enter the IP address of the neighbor in dotted decimal format.
Parameters number Enter a number as the metric to be assigned to routes from other protocols. The range is from 1 to 4294967295. Defaults 0 Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.
Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
maximum-paths Configure the maximum number of parallel routes (multipath support) BGP supports. S4820T Syntax maximum-paths {ebgp | ibgp} number To return to the default values, enter the no maximum-paths command. Parameters ebgp Enter the keyword ebgp to enable multipath support for External BGP routes. ibgp Enter the keyword ibgp to enable multipath support for Internal BGP routes. number Enter a number as the maximum number of parallel paths. The range is from 2 to 64.
neighbor activate This command allows the specified neighbor/peer group to be enabled for the current AFI/SAFI (Address Family Identifier/Subsequent Address Family Identifier). S4820T Syntax neighbor [ip-address | peer-group-name] activate To disable, use the no neighbor [ip-address | peer-group-name] activate command. Parameters ip-address (OPTIONAL) Enter the IP address of the neighbor in dotted decimal format. peer-groupname (OPTIONAL) Enter the name of the peer group.
neighbor add-path This command allows the specified neighbor/peer group to send/receive multiple path advertisements. S4820T Syntax Parameters neighbor [ip-address | peer-group-name] add-path [send | receive | both] path-count ip-address (OPTIONAL) Enter the IP address of the neighbor in dotted decimal format. peer-groupname (OPTIONAL) Enter the name of the peer group. send Enter the keyword send to indicate that the system sends multiple paths to peers.
neighbor advertisement-interval Set the advertisement interval between BGP neighbors or within a BGP peer group. S4820T Syntax neighbor {ip-address | peer-group-name} advertisement-interval seconds To return to the default value, use the no neighbor {ip-address | peergroup-name} advertisement-interval command. Parameters Defaults ip-address (OPTIONAL) Enter the IP address of the neighbor in dotted decimal format.
neighbor advertisement-start To send BGP routing updates, set the minimum interval before starting. S4820T Syntax neighbor {ip-address} advertisement-start seconds To return to the default value, use the no neighbor {ip-address} advertisement-start command. Parameters ip-address (OPTIONAL) Enter the IP address of the neighbor in dotted decimal format. seconds Enter a number as the time interval, in seconds, before BGP route updates are sent. The range is from 0 to 3600 seconds.
Parameters ip-address (OPTIONAL) Enter the IP address of the neighbor in dotted decimal format. peer-groupname Enter the name of the peer group to set the advertisement interval for all routers in the peer group. number Enter a number of times to allow this neighbor ID to use the AS path. The range is from 1 to 10. Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific.
Parameters ip-address (OPTIONAL) Enter the IP address of the neighbor in dotted decimal format. peer-groupname Enter the name of the peer group to set the default route of all routers in that peer group. route-map map-name (OPTIONAL) Enter the keyword route-map then the name of a configured route map. Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific.
You cannot set this configuration for a peer that is associated with a peer group. Similarly, you cannot associate a peer to a peer group if that peer is already configured with these settings. In order that settings corresponding to the neighbor default-originate command take effect, you must execute the clear ip bgp command immediately after you execute the neighbor default-originate command. neighbor description Assign a character string describing the neighbor or group of neighbors (peer group).
neighbor distribute-list Distribute BGP information via an established prefix list. S4820T Syntax neighbor {ip-address | peer-group-name} distribute-list prefixlist-name {in | out} To delete a neighbor distribution list, use the no neighbor {ip-address | peer-group-name} distribute-list prefix-list-name {in | out} command. Parameters ip-address Enter the IP address of the neighbor in dotted decimal format.
Usage Information Other BGP filtering commands include: neighbor filter-list, ip as-path access-list, and neighbor route-map. Related Commands neighbor route-map — assigns a route map to a neighbor or peer group. neighbor ebgp-multihop Attempt and accept BGP connections to external peers on networks that are not directly connected.
Usage Information To prevent loops, the neighbor ebgp-multihop command does not install the default routes of the multihop peer. Networks not directly connected are not considered valid for best-path selection. neighbor fall-over Enable or disable fast fall-over for BGP neighbors. S4820T Syntax neighbor {ipv4-address | peer-group-name} fall-over To disable, use the no neighbor {ipv4-address | peer-group-name} fall-over command.
Related Commands show ip bgp neighbors — displays information on the BGP neighbors. neighbor local-as To accept external routes from neighbors with a local AS number in the AS number path, configure Internal BGP (IBGP) routers. S4820T Syntax neighbor {ip-address | peer-group-name} local-as as-number [noprepend] To return to the default value, use the no neighbor {ip-address | peergroup-name} local-as command. Parameters ip-address Enter the IP address of the neighbor in dotted decimal format.
Usage Information If a local-as is configured, BGP does not allow for the configuration of BGP confederation. Similarly, if BGP confederation is configured, then BGP does not allow the configuration of local-as. This command automatically restarts the neighbor session for the configuration to take effect. Related Commands bgp four-octet-as-support — enables 4-byte support for the BGP process. neighbor maximum-prefix Control the number of network prefixes received.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.
password Enter a text string up to 80 characters long. The first character of the password must be a letter. You cannot use spaces in the password. Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
Also, if you configure different passwords on the two routers, the following message appears on the console: %RPM0-P:RP1 %KERN-6-INT: BGP MD5 password mismatch from [peer's IP address] : 11502 to [local router's IP address] :179 neighbor peer-group (assigning peers) Allows you to assign one peer to an existing peer group. S4820T Syntax neighbor {ip-address | peer-group peer-group-name} dmzlink-bw To delete a peer from a peer group, use the no neighbor {ip-address | peer-group peer-group-name} command.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. You can assign up to 256 peers to one peer group. When you add a peer to a peer group, it inherits all the peer group’s configured parameters.
Parameters peer-groupname Enter a text string up to 16 characters long as the name of the peer group. Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.
Parameters peer-groupname Enter a text string up to 16 characters long as the name of the peer group. limit (Optional) Enter the keyword limit to constrain the numbers of sessions for this peer-group. The range is from 2 to 256. The default is 256. Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
neighbor remote-as Create and specify the remote peer to the BGP neighbor. S4820T Syntax neighbor {ip-address | peer-group-name} remote-as number To delete a remote AS entry, use the no neighbor {ip-address | peergroup-name} remote-as number command. Parameters ip-address Enter the IP address of the neighbor to enter the remote AS in its routing table. peer-groupname Enter the name of the peer group to enter the remote AS into routing tables of all routers within the peer group.
Related Commands router bgp — enters ROUTER BGP mode and configures routes in an AS. bgp four-octet-as-support — enables 4-byte support for the BGP process. neighbor remove-private-as Remove private AS numbers from the AS-PATH of outgoing updates. S4820T Syntax neighbor {ip-address | peer-group-name} remove-private-as To return to the default, use the no neighbor {ip-address | peer-groupname} remove-private-as command.
If the AS-PATH contains both public and private AS number or contains AS numbers of an EBGP neighbor, the private AS numbers are not removed. If a confederation contains private AS numbers in its AS-PATH, the software removes the private AS numbers only if they follow the confederation numbers in the AS path. Private AS numbers are from 64512 to 65535 (2 byte). neighbor route-map Apply an established route map to either incoming or outbound routes of a BGP neighbor or peer group.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. When you apply a route map to outbound routes, only routes that match at least one section of the route map are permitted.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. A route reflector reflects routes to the neighbors assigned to the cluster.
Parameters ip-address Enter the IP address of the peer router in dotted decimal format. peer-groupname Enter the name of the peer group to send a COMMUNITY attribute to all routers within the peer group. extended (OPTIONAL) Enter the keyword extended to send extended community attribute. standard (OPTIONAL) Enter the keyword standard to send standard community attribute. Defaults Not configured and COMMUNITY attributes are not sent to neighbors.
To enable a disabled neighbor or peer group, use the neighbor {ip-address | peer-group-name}no shutdown command. Parameters ip-address Enter the IP address of the neighbor in dotted decimal format. peer-groupname Enter the name of the peer group to disable or enable all routers within the peer group. Defaults Enabled (that is, BGP neighbors and peer groups are disabled.) Command Modes ROUTER BGP Command History This guide is platform-specific.
neighbor soft-reconfiguration inbound Enable soft-reconfiguration for BGP. S4820T Syntax neighbor {ip-address | peer-group-name} soft-reconfiguration inbound To disable, use the no neighbor {ip-address | peer-group-name} softreconfiguration inbound command. Parameters ip-address Enter the IP address of the neighbor in dotted decimal format. peer-groupname Enter the name of the peer group to disable or enable all routers within the peer group.
CAUTION: Inbound update storage is a memory-intensive operation. The entire BGP update database from the neighbor is stored in memory regardless of the inbound policy results applied on the neighbor. NOTE: This command is supported in BGP Router Configuration mode for IPv4 Unicast address only. Related Commands show ip bgp neighbors — displays routes received by a neighbor. neighbor timers Set keepalive and hold time timers for a BGP neighbor or a peer group.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Timer values configured with the neighbor timers command override the timer values configured with any other command.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Loopback interfaces are up constantly and the BGP session may need one interface constantly up to stabilize the session.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. In the Dell Networking OS best path selection process, the path with the highest weight value is preferred.
• match ip address • set community • set local-preference • set metric • set next-hop • set origin • set weight If the route map is not configured, the default is deny (to drop all routes). Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
In BGP, the next-hop for the route is calculated from the information that is acquired through IGP or static routes. Related Commands redistribute — redistributes routes into BGP. network backdoor Specify this IGP route as the preferred route. S4820T Syntax network ip-address mask backdoor To remove a network, use the no network ip-address mask backdoor command. Parameters ip-address Enter an IP address in dotted decimal format of the network.
Usage Information Although Dell Networking OS does not generate a route due to the backdoor config, there is an option for injecting/sourcing a local route in the presence of network backdoor config on a learned route. permit bandwidth Enables you to specify link band width extended-community attribute as the matching criteria to permit incoming or outgoing traffic. Syntax permit bandwidth To disable this setting, enter the no permit bandwidth command.
route-map map-name (OPTIONAL) Enter the keyword route-map then the name of an established route map. Only the following ROUTE-MAP mode commands are supported: • match ip address • set community • set local-preference • set metric • set next-hop • set origin • set weight If the route map is not configured, the default is deny (to drop all routes). Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific.
If you do not configure the default-metric command, in addition to the redistribute command, or there is no route map to set the metric, the metric for redistributed static and connected is “0”. To redistribute the default route (0.0.0.0/0), configure the neighbor defaultoriginate command. As BGP does not query next-hop information corresponding to locally originated routes, a local route with an unreachable next-hop is chosen as the best route.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series.
Usage Information A new policy command is introduced in order to attach the Link Bandwidth extended community only to the prefixes that are received from a neighbor that satisfy the desired conditions. This command is relevant for both inbound as well as outbound policy handling (for received prefixes). Also, there is no change to the set of supported conditions or filters. During configuration, the bandwidth is specified in Mbps, not in bytes/second.
00000000 419ef06c 00000000 00000000 00000000 00000000 00000000 0181a1e4 0181a25c 41af92c0 00000000 00000000 00000000 00000000 00000001 0181a1e4 0181a25c 41af9400 00000000 PDU[2] : len 19, captured 00:34:51 ago ffffffff ffffffff ffffffff ffffffff 00130400 PDU[3] : len 19, captured 00:34:51 ago ffffffff ffffffff ffffffff ffffffff 00130400 [. . .] Outgoing packet capture enabled for BGP neighbor 20.20.20.
Example Dell(conf-router_bgp)#show config ! router bgp 100 network 1.1.11.1/32 network 1.1.12.1/32 network 1.1.13.1/32 neighbor 10.1.1.2 remote-as 200 neighbor 10.1.1.2 no shutdown show ip bgp View the current BGP IPv4 routing table for the system. S4820T Syntax Parameters show ip bgp [vrf vrf-name] [ipv4 unicast] [network [networkmask] [longer-prefixes]] vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the name of the VRF to view ipv4–unicast route information corresponding to that VRF.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Added the add-path option to the S4810. Output on the S4810 shows the ADDPATH parameters. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. When you enable the bgp non-deterministic-med command, the show ip bgp command output for a BGP route does not list the INACTIVE reason. In BGP, this command displays the exact reason why the route is discarded.
All the show and debugs commands display the link band width extendedcommunity prefixed with DMZ-Link-bw along with other extended communities. Dell#show ip bgp 3.3.3.0/24 BGP routing table entry for 3.3.3.0/24 Paths: (1 available, table Default-IP-Routing-Table.) Not advertised to any peer Received from : 1.1.1.2 (3.3.3.1) Best AS_PATH : Next-Hop : 1.1.1.
The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series.
Status codes: s suppressed, S stale, d dampened, h history, * valid, > best Path source: I - internal, a - aggregate, c - confed-external, r - redistributed n - network, D - denied, S - stale Origin codes: i - IGP, e - EGP, ? - incomplete Network Next Hop Weight Path *>I 55.0.0.0/24 172.16.0.2 0 0 400 500 600 i *>I 66.0.0.0/24 172.16.0.2 0 0 500 i *>I 77.0.0.0/24 172.16.0.
All routes with the NO_EXPORT_SUBCONFED (0xFFFFFF03) community attribute must not be advertised to external BGP peers. no-advertise Enter the keywords no-advertise to view all routes containing the well-known community attribute of NO_ADVERTISE. All routes with the NO_ADVERTISE (0xFFFFFF02) community attribute must not be advertised to other BGP peers. no-export Enter the keywords no-export to view all routes containing the well-known community attribute of NO_EXPORT.
The following describes the show ip bgp community command shown in the following example. Example Field Description Network Displays the destination network prefix of each BGP route. Next Hop Displays the next hop address of the BGP router. If 0.0.0.0 is listed in this column, then local routes exist in the routing table. Metric Displays the BGP route’s metric, if assigned. LocPrf Displays the BGP LOCAL_PREF attribute for the route. Weight Displays the route’s weight.
*> 66.0.0.0/24 172.16.0.2 0 200 i show ip bgp community-list View routes that a specific community list affects. S4820T Syntax Parameters show ip bgp [vrf vrf-name] [ipv4 {unicast | multicast} | ipv6 unicast] community-list community-list-name [exact-match] vrf vrf-name (OPTIONAL) Enter the keywords vrf and then the name of the VRF to view routes affected by a specific community list corresponding to that VRF.
Usage Information Version Description 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. The show ip bgp community-list command without any parameters lists BGP routes matching the Community List and the output is the same as for the show ip bgp command output. The following describes the show ip bgp community-list pass command shown in the following example. Example Field Description Network Displays the destination network prefix of each BGP route.
Communities : 200:1 1000:1 3000:1 show ip bgp dampened-paths View BGP routes that are dampened (non-active). S4820T Syntax Parameters Command Modes Command History show ip bgp [vrf vrf-name] [ipv4 {multicast | unicast} | ipv6 unicast] dampened-paths vrf vrf-name (OPTIONAL) Enter the keywords vrf and then the name of the VRF to view routes that are affected by a specific community list corresponding to that VRF.
Usage Information Version Description 7.7.1.0 Introduced on the C-Series. To determine a BGP session flap, both a route-down event and a subsequent route-up event corresponding to a single route are considered. As a result, a flap event is penalized only one time during the route-down event. The subsequent route-up event corresponding to the same route is not considered as a flap and is not penalized.
Parameters Command Modes Command History vrf vrf-name (OPTIONAL) Enter the keywords vrf and then the name of the VRF to view routes that are affected by a specific community list corresponding to that VRF. ipv4 multicast (OPTIONAL) Enter the keyword ipv4 followed by the keyword multicast to view information related only to ipv4 multicast routes. ipv4 unicast (OPTIONAL) Enter the keywords ipv4 followed by the keyword unicast to view information related only to ipv4 unicast routes.
The following describes the show ip bgp damp command shown in the following example. Example Field Description Network Displays the network ID to which the route is dampened. From Displays the IP address of the neighbor advertising the dampened route. Reuse Displays the hour:minutes:seconds until the dampened route is available. Path Lists all the ASs the dampened route passed through to reach the destination network.
Example Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.5.1.0 Introduced.
CleanRibTmrP 0x41ee7104 PeerUpdTmrP 0x41ee70cc : DfrdNHTmrP 0x41ee7174 : DfrdRtselTmrP 0x41ee713c : FastExtFallover 1 : FastIntFallover 0 : Enforce1stAS 1 PeerIdBitsP 0x41967120 : softOutSz 16 : RibUpdCtxCBP 0 UpdPeerCtxCBP 0 : UpdPeerCtxAFI 0 : TcpioCtxCB 0 : RedistBlk 1 NextCBPurg 1101119536 : NumPeerToPurge 0 : PeerIBGPCnt 0 : NonDet 0 : DfrdPathSel 0 BGPRst 0 : NumGrCfg 1 : DfrdTmestmp 0 : SnmpTrps 0 : IgnrBestPthASP 0 RstOn 1 : RstMod 1 : RstRole 2 : AFFalgs 7 : RstInt 120 : MaxeorExtInt 361 FixedPartC
Command Modes Command History ipv4 multicast (OPTIONAL) Enter the keyword ipv4 followed by the keyword multicast to view information related only to ipv4 multicast routes. ipv4 unicast (OPTIONAL) Enter the keywords ipv4 unicast to view information only related to ipv4 unicast routes. ipv6 unicast (OPTIONAL) Enter the keyword ipv6 followed by the keyword unicast to view information related only to ipv6 unicast routes. list name Enter the extended community list name you wish to view.
Status codes: s suppressed, S stale, d dampened, h history, * valid, > best Path source: I - internal, a - aggregate, c - confed-external, r - redistributed n - network, D - denied, S - stale Origin codes: i - IGP, e - EGP, ? - incomplete Network Next Hop Metric Weight Path *> 55.0.0.0/24 172.16.0.2 0 200 i *> 77.0.0.0/24 172.16.0.2 0 200 i Dell#show ip bgp extcommunity-list ec % Error: Extended community list does not exist.
Usage Information Example Version Description 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. The following describes the show ip bgp filter-list hello command shown in the following example.
Origin codes: i - IGP, e - EGP, ? - incomplete Network Weight Path *> 55.0.0.0/24 172.16.0.2 *> 66.0.0.0/24 172.16.0.2 Next Hop Metric LocPrf 0 200 400 500 600 i 0 200 500 i show ip bgp flap-statistics View flap statistics on BGP routes.
• + = (plus) the sequences in a pattern (one or more sequences). • ? = (question mark) sequences in a pattern (either zero or one sequences). NOTE: Enter an escape sequence (CTRL+v) prior to entering the ? regular expression. • [ ] = (brackets) a range of single-character patterns. • ( ) = (parenthesis) groups a series of pattern elements to a single element. • { } = (braces) minimum and the maximum match count. • ^ = (caret) the beginning of the input string.
Example Field Description Duration Displays the hours:minutes:seconds since the route first flapped. Reuse Displays the hours:minutes:seconds until the flapped route is available. Path Lists all the ASs the flapping route passed through to reach the destination network. Dell#show ip bgp flap-statistics BGP local RIB : Routes to be Added 0, Replaced 0, Withdrawn 0 BGP local router ID is 192.168.11.
Usage Information Example Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. The following describes the show ip bgp inconsistent-as command shown in the following example.
* 6.0.0.0/20 * *> * * 9.2.0.0/16 * --More-- 63.114.8.60 63.114.8.34 63.114.8.33 63.114.8.33 63.114.8.60 63.114.8.34 0 0 0 0 0 0 0 18508 18508 18508 18508 18508 18508 209 209 ? 209 209 209 3549 i 3549 i 3549 i 701 i 701 i Dell>sho ip bgp vrf testinconsistent-as BGP table version is 11, local router ID is 66.66.77.
ipv4 unicast (OPTIONAL) Enter the keyword ipv4 followed by the keyword unicast to view information related only to ipv4 unicast routes. ipv6 unicast (OPTIONAL) Enter the keyword ipv6 followed by the keyword unicast to view information related only to ipv6 unicast routes. ip-address (OPTIONAL) Enter the IP address of the neighbor to view only BGP information exchanged with that neighbor. advertisedroutes (OPTIONAL) Enter the keywords advertised-routes to view only the routes the neighbor sent.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Added the add-path option to the S4810. Output on the S4810 shows the ADDPATH parameters. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.5.1.0 Added the detail option. Output now displays the default MED value. 7.2.1.0 Added the received and denied route options. 6.3.
The Lines Beginning with: Description • hold time is the number of seconds configured between messages from its neighbor • keepalive interval is the number of seconds between keepalive messages to help ensure that the TCP session is still alive. Received messages This line displays the number of BGP messages received, the number of notifications (error messages), and the number of messages waiting in a queue for processing.
Example The Lines Beginning with: Description Foreign host: Displays the peering address of the neighbor and the TCP port number. Dell#show ip bgp neighbors 172.16.0.2 BGP neighbor is 172.16.0.2, remote AS 200, external link Member of peer-group port0 for session parameters BGP remote router ID 172.16.0.
show ip bgp next-hop View all next hops (using learned routes only) with current reachability and flap status. This command only displays one path, even if the next hop is reachable by multiple paths. S4820T Syntax Parameters show ip bgp [vrf vrf-name] next-hop vrf vrf-name Enter the keyword vrf followed by the name of the VRF to view all next hops corresponding to that VRF. Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific.
Example Field Description Time Elapsed Displays the time elapsed since the next hop was learned. If the route is down, this field displays time elapsed since the route went down. Dell# show ip bgp next-hop Next-hop Resolved 172.16.0.2 YES Dell# show ip bgp paths View all the BGP path attributes in the BGP database.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Added support for VRF for the S4810, S4820T, and S6000. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
show ip bgp paths community View all unique COMMUNITY numbers in the BGP database. S4820T Syntax Parameters show ip bgp [vrf vrf-name] paths community vrf vrf-name (OPTIONAL) Enter the keyword vrf to view all unique COMMUNITY numbers in the BGP database corresponding to that VRF. NOTE: You can use this attribute to view information on unique COMMUNITY numbers in a BGP database that correspond to either a default or a non-default VRF.
Example Field Description Refcount Displays the number of BGP routes using these communities. Community Displays the community attributes in this BGP path. Dell#show ip bgp paths community Total 2 communities Refcount Community 1 NO-ADVERTISE 1 200:1 1000:1 3000:1 show ip bgp peer-group Allows you to view information on the BGP peers in a peer group.
Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example 516 Version Description 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. Introduced on S6000–ON. 9.4.(0.0) Added support for VRF. 8.3.19.0 Introduced on the S4820T.
BGP version 4 Minimum time between advertisement runs is 30 seconds For address family: IPv4 Unicast BGP neighbor is port0, peer-group external Update packing has 4_OCTET_AS support enabled Number of peers in this group 1 Maximum limit on the accepted connections 256 Peer-group members (* - outbound optimized): 172.16.0.2 Dell# Related Commands neighbor peer-group (assigning peers) — assigns a peer to a peer-group. neighbor peer-group (creating group) — creates a peer group.
• • Command Modes Command History • • ^ = (caret) the beginning of the input string. If you use the caret at the beginning of a sequence or range, it matches on everything BUT the characters specified. $ = (dollar sign) the end of the output string. EXEC EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
r - redistributed n - network, D - denied, S - stale Origin codes: i - IGP, e - EGP, ? - incomplete Network Weight Path *> 55.0.0.0/24 172.16.0.2 *> 66.0.0.0/24 172.16.0.2 Next Hop Metric LocPrf 0 200 i 0 200 i show ip bgp summary Allows you to view the status of all BGP connections.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. In BGP, route attributes are maintained at different locations. When attributes that correspond to multiple routes change, then attribute counts that the show ip bgp summary command displays are calculated as summations of attributes corresponding to all the associated routes.
Field Description them. The show ip bgp community command provides more details on the COMMUNITY attributes. Dampening enabled Displayed only when you enable dampening. Displays the number of paths designated as history, dampened, or penalized. Neighbor Displays the BGP neighbor address. AS Displays the AS number of the neighbor. MsgRcvd Displays the number of BGP messages that neighbor received. MsgSent Displays the number of BGP messages that neighbor sent.
Field Description If the neighbor is disabled, the phrase (Admin shut) appears in this column. Example Dell#show ip bgp summary BGP router identifier 192.168.11.
Example Version Description 7.6.1.0 Introduced on the E-Series. Dell#show running-config bgp ! router bgp 100 network 1.1.11.1/32 network 1.1.12.1/32 network 1.1.13.1/32 neighbor 10.1.1.2 remote-as 200 neighbor 10.1.1.2 no shutdown Dell# timers bgp Adjust the BGP Keep Alive and Hold Time timers. S4820T Syntax timers bgp keepalive holdtime To return to the default, use the no timers bgp command.
Version Description 7.7.1.0 Introduced on the C-Series. 7.6.1.0 Introduced on the E-Series. MBGP Commands Multiprotocol BGP (MBGP) is an enhanced BGP that enables multicast routing policy throughout the internet and connecting multicast topologies between BGP and autonomous systems (ASs). Dell Networking OS MBGP is implemented as per IETF RFC 1858. BGPv4 is supported in the following: Dell Networking OS Version Platform Support 7.8.1.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. b Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version 8.3.19.0 Introduced on the S4820T. Version 8.3.7.0 Introduced on the S4810. Version 7.8.1.0 Introduced on the S-Series. Version 7.7.1.0 Introduced on the C-Series.
ipv6 unicast Command Modes Command History • EXEC • EXEC Privilege (OPTIONAL) Enter the keyword ipv6 followed by the keyword unicast to view information related only to ipv6 unicast routes. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
Example Field Description Path Lists all the ASs the dampened route passed through to reach the destination network. Dell#show ip bgp dampened-paths BGP local RIB : Routes to be Added 0, Replaced 0, Withdrawn 0 BGP local router ID is 192.168.11.5 Status codes: s suppressed, S stale, d dampened, h history, * valid, > best Path source: I - internal, a - aggregate, c - confed-external, r - redistributed n - network, D - denied, S - stale Origin codes: i - IGP, e - EGP, ? - incomplete Network d 55.0.0.
IPADDR:NN Enter the IP address specific extended community in the format IPADDR:NN (4-byte IPv4 Unicast Address:2-byte community value). additive (OPTIONAL) Enter the keyword additive to add to the existing extended community. non-trans (OPTIONAL) Enter the keywords non-trans to indicate a non-transitive BGP extended community. Defaults none Command Modes ROUTE MAP (config-route-map) Command History This guide is platform-specific.
To delete the site-of-origin community, use the no set extcommunity command. Parameters as4 ASN4:NN Enter the keyword as4 then the 4-octet AS specific extended community number in the format ASN4:NN (4byte AS number:2-byte community value). ASN:NNNN Enter the 2-octet AS specific extended community number in the format ASN:NNNN (2-byte AS number:4-byte community value).
show ip bgp ipv4 extcommunity-list To display the IPv4 routes matching the extended community list name, use this feature. Syntax Parameters show ip bgp [ipv4 [multicast | unicast] | ipv6 unicast] extcommunity-list name multicast Enter the keyword multicast to display the multicast route information. unicast Enter the keyword unicast to display the unicast route information. ipv6 unicast Enter the keywords ipv6 unicast to display the IPv6 unicast route information.
Example Dell#show ip bgp ipv4 multicast extcommunity-list BGP routing table entry for 192.168.1.0/24, version 2 Paths: (1 available, table Default-IP-Routing-Table.) Not advertised to any peer Received from : 100.100.1.2 (2.4.0.1) Best AS_PATH : 200 Next-Hop : 100.100.1.2, Cost : 0 Origin IGP, Metric 4294967295 (Default), LocalPref 100, Weight 0, external Communities : 300:400 500:600 Extended Communities : RT:1111:4278080 SoO:35:4 SoO:36:50529043 SoO:37:50529044 SoO:38:50529045 SoO:0.0.0.2:33 SoO:506.
Example Field Description Address Displays the internal address where the path attribute is stored. Hash Displays the hash bucket where the path attribute is stored. Refcount Displays the number of BGP routes using these extended communities. Community Displays the extended community attributes in this BGP path. Dell#show ip bgp paths extcommunity Total 1 Extended Communities Address 0x41d57024 Hash Refcount Extended Community 12272 1 RT:7:200 SoO:5:300 SoO:0.0.0.
deny RT:1234:12 permit regexp 123 deny regexp 234 deny regexp 123 Dell# IPv6 BGP Commands IPv6 border gateway protocol (IPv6 BGP) is supported on the S4820T platform. BGP is an external gateway protocol that transmits interdomain routing information within and between Autonomous Systems (AS). Basically, two routers (called neighbors or peers) exchange information including full routing tables and periodically send messages to update those routing tables.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.0 Introduced on the S4820T. 8.4.1.0 Added support for IPv4 multicast and IPv6 unicast routes. 7.8.1.0 Introduced on the S4810. 7.7.1.0 Introduced on the C-Series. 7.2.1.
Usage Information Version Description 8.4.1.0 Added support for IPv4 multicast and IPv6 unicast routes. 7.8.1.0 Introduced on the S4810. 7.7.1.0 Introduced on the C-Series. 7.2.1.0 Introduced on the E-Series TeraScale. This command turns on BGP soft-reconfiguration inbound debugging for IPv6 unicast routes. If no neighbor is specified, debug is turned on for all neighbors. ipv6 prefix-list Configure an IPv6 prefix list.
Parameters ipv4-address | ipv6-address Enter the IP address of the neighbor for which you want to start storing inbound routing updates. peer-groupname Enter the name of the peer group for which you want to start storing inbound routing updates. Defaults Disabled. Command Modes ROUTER BGPv6 ADDRESS FAMILY (conf-router_bgpv6_af) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
show ipv6 mbgproutes Display the selected IPv6 MBGP route or a summary of all MBGP routes in the table. S4820T Syntax Parameters show ipv6 mbgproutes ipv6-address prefix-length | summary ipv6-address prefix-length (OPTIONAL) Enter the IPv6 address in the x:x:x:x::x format then the prefix length in the /x format. The range is from /0 to /128. NOTE: The :: notation specifies successive hexadecimal fields of zeros. summary Display a summary of RPF routes.
Content Addressable Memory (CAM) 11 Content addressable memory (CAM) commands are supported on the Dell Networking S4820T platform. NOTE: Not all CAM commands are supported on all platforms. Be sure to note the platform when looking for a command. WARNING: If you are using these features for the first time, contact Dell Networking Technical Assistance Center (TAC) for guidance. CAM Profile Commands The CAM profiling feature allows you to partition the CAM to best suit your application.
cam-acl (Configuration) Select the default CAM allocation settings or reconfigure a new CAM allocation for Layer 2, IPv4, and IPv6 ACLs, Layer 2 and Layer 3 (IPv4) QoS, Layer 2 Protocol Tunneling (L2PT), IP and MAC source address validation for DHCP, Ethernet Connectivity Fault Management (CFM) ACLs, OpenFlow, and Policy-based Routing (PBR).
l2qos number Enter the keyword l2qos and then the number of FP blocks for l2 qos. The range is from 1to 8. l2pt number Enter the keyword l2pt and then the number of FP blocks for l2 protocol tunnelling. The range is from 0 to 1. Ipmacacl number Enter the keyword ipmacacl and then the number of FP blocks for IP and MAC ACL. The range is from 0 to 6. ecfmacl number Enter the keyword ecfmacacl and then the number of FP blocks for ECFM ACL. The range is from 0 to 5.
l2acl number ipv4acl number ipv6acl number, ipv4qos number l2qos numberl2pt number ipmacacl number ecfmacl number {nlbclusteracl] [vman-qos | vman-dual-qos number] ipv4pbr numberopenflo w {4|8} | fcoe number [iscsioptacl number] [vrfv4acl number] Allocate space to each CAM region. Enter 4 or 8 for the number of OpenFlow FP blocks.
Usage Information Version Description 8.2.1.0 Introduced on the S-Series. 7.8.1.0 Introduced on the C-Series. Save the new CAM settings to the startup-config (write-mem or copy run start) then reload the system for the new settings to take effect. The total amount of space allowed is 16 FP Blocks. System flow requires three blocks; these blocks cannot be reallocated. Only 13 number of blocks can be configured by the user .
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. cam-optimization Optimize CAM utilization for QoS Entries by minimizing require policy-map CAM space. S4820T Syntax Parameters cam-optimization [qos] qos Optimize CAM usage for QoS. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
show cam-acl Display the details of the CAM profiles on the chassis and all stack units. S4820T Syntax show cam-acl Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000.
Current Settings(in block sizes) 1 block = 128 entries L2Acl : 6 Ipv4Acl : 4 Ipv6Acl : 0 Ipv4Qos : 2 L2Qos : 1 L2PT : 0 IpMacAcl : 0 VmanQos : 0 VmanDualQos : 0 EcfmAcl : 0 FcoeAcl : 0 iscsiOptAcl : 0 ipv4pbr : 0 vrfv4Acl : 0 Openflow : 0 fedgovacl : 0 nlbclusteracl: 0 -- stack-unit 1 -Current Settings(in block sizes) 1 block = 128 entries L2Acl : 6 Ipv4Acl : 4 Ipv6Acl : 0 Ipv4Qos : 2 L2Qos : 1 L2PT : 0 IpMacAcl : 0 VmanQos : 0 VmanDualQos : 0 EcfmAcl : 0 FcoeAcl : 0 iscsiOptAcl : 0 ipv4pbr : 0 vrfv4Acl : 0
Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Example (SSeries) Dell#test cam-usage service-policy input In stack-unit all Stack-Unit | Portpipe | CAM Partition | Available CAM | Estimated CAM per Port| Status ------------------------------------------------------------------------------------0 | 0 | IPv4Flow | 102 | 0| Allowed 0 | 0 | IPv4Flow | 102 | 0| Allowed Dell# ! Dell#test cam-usage service-policy input In stack-unit 0 portset 0 Stack-Unit | Portpipe | CAM Partition | Available CAM | Estimated CAM per Port| Status -----------------------------
102| Dell# Content Addressable Memory (CAM) 0| 0| IPv4Flow| 0|Allowed 549
12 Control Plane Policing (CoPP) The CoPP commands are supported on the Dell Networking S4820T platform. control-plane-cpuqos To manage control-plane traffic, enter control-plane mode and configure the switch. S4820T Syntax control-plane-cpuqos Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
ip unknown-unicast Enable IPv4 catch-all route. S4820T Syntax ip unknown-unicast [vrf vrf-name] To remove the IPv4 catch-all route (0.0.0.0/0) from the LPM route forwarding table in hardware which gets added as a default configuration after the initialization of FIB Agent module, use the no ip unknown-unicast command.
Usage Information Version Description 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. All the default catch-all entries in the longest prefix match (LPM) table collect and transmit all unresolved IPv6 packets to the CPU, even if they are destined for unknown destinations. service-policy rate-limit-cpu-queues Apply a policy map for the system to rate limit control traffic on a per-queue basis.
policy-map-input — creates an input policy map. service-policy rate-limit-protocols Apply a policy for the system to rate limit control protocols on a per-protocol basis. S4820T Syntax Parameters service-policy rate-limit-protocols policy-name policy-name Enter the service-policy name, using a string up to 32 characters. Defaults Not configured. Command Modes CONTROL-PLANE-CPUQOS Command History This guide is platform-specific.
policy-map-input — creates an input policy map. show cpu-queue rate cp Display the rates for each CPU queue. S4820T Syntax show cpu-queue rate cp Defaults Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
Q10 Q11 300 300 50 50 show ip protocol-queue-mapping Display the queue mapping for each configured protocol. S4820T Syntax show ip protocol-queue-mapping Defaults Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.
_ _ PIM _ _ UDP (RIP) _ _ TCP (SSH) _ _ TCP (TELNET) _ _ VRRP _ _ Dell# Dell# Dell# Dell# Dell# any any _ Q11 any 520 _ Q9 any 22 _ Q6 any 23 _ Q6 any any _ Q10 show ipv6 protocol-queue-mapping Display the queue mapping for each configured IPv6 protocol. S4820T Syntax show ipv6 protocol-queue-mapping Defaults Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific.
_ ICMPV6 RA _ ICMPV6 NS _ ICMPV6 RS _ ICMPV6 _ VRRPV6 _ OSPFV3 _ Dell# Dell# Dell# _ _ _ _ _ _ _ any any _ Q6 any any _ Q5 any any _ Q5 any any _ Q6 any any _ Q10 any any _ Q9 show mac protocol-queue-mapping Display the queue mapping for the MAC protocols. S4820T Syntax show mac protocol-queue-mapping Defaults Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific.
Q7 LACP Q7 LLDP Q8 GVRP Q8 STP Q7 ISIS Q9 Q9 Dell# 558 CP _ 01:80:c2:00:00:02 CP _ any CP _ 01:80:c2:00:00:21 CP _ 01:80:c2:00:00:00 CP _ 01:80:c2:00:00:14/15 CP _ 09:00:2b:00:00:04/05 CP 0x8809 0x88cc any any any any Control Plane Policing (CoPP)
Data Center Bridging (DCB) 13 Data center bridging (DCB) refers to a set of IEEE Ethernet enhancements that provide data centers with a single, robust, converged network to support multiple traffic types, including local area network (LAN), server, and storage traffic. The Dell Networking operating software commands for data center bridging features include 802.1Qbb priority-based flow control (PFC), 802.1Qaz enhanced transmission selection (ETS), and the data center bridging exchange (DCBX) protocol.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module. By default, iSCSI is enabled on the unit and the flow control is enabled on all of the interfaces.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.
pfc mode on Enable the PFC configuration on the port so that the priorities are included in DCBX negotiation with peer PFC devices. Syntax pfc mode on To disable the PFC configuration, use the no pfc mode on command. Defaults PFC mode is on. Command Modes DCB INPUT POLICY Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
pfc no-drop queues Configure the port queues that still function as no-drop queues for lossless traffic. Syntax pfc no-drop queues queue-range To remove the no-drop port queues, use the no pfc no-drop queues command. Parameters queue-range Enter the queue range. Separate the queue values with a comma; specify a priority range with a dash; for example, pfc no-drop queues 1,3 or pfc no-drop queues 7 or pfc no-drop queues 0,7. The range is from 0 to 3. Defaults No lossless queues are configured.
dot1p Value in the Incoming Frame Description heading 4 2 5 3 6 3 7 3 show dcb Displays the data center bridging status, the number of PFC-enabled ports, and the number of PFCenabled queues. Syntax Parameters show dcb [stack-unit unit-number] [port-set port-set-number] unit-number Enter the DCB unit number. port-setnumber Enter the port-set number. Command Modes EXEC Privilege Command History This guide is platform-specific.
show interface pfc Displays the PFC configuration applied to ingress traffic on an interface, including priorities and link delay. Syntax Parameters show interface port-type slot/port[] pfc {summary | detail} port-type slot/ port[] pfc Enter the port-type slot and port PFC information. {summary | detail} Enter the keyword summary for a summary list of results or enter the keyword detail for a full list of results. Command Modes INTERFACE Command History This guide is platform-specific.
Field Description Local is enabled DCBX operational status (enabled or disabled) with a list of the configured PFC priorities. Operational status (local port) Port state for current operational PFC configuration: • Init: Local PFC configuration parameters were exchanged with the peer. • Recommend: Remote PFC configuration parameters were received from the peer. • Internally propagated: PFC configuration parameters were received from the configuration source.
Example (Summary) Field Description PFC TLV Statistics: Output TLV pkts Number of PFC TLVs transmitted. PFC TLV Statistics: Error pkts Number of PFC error packets received. PFC TLV Statistics: Pause Tx pkts Number of PFC pause frames transmitted. PFC TLV Statistics: Pause Rx pkts Number of PFC pause frames received.
show interface pfc statistics Displays counters for the PFC frames received and transmitted (by dot1p priority class) on an interface. Syntax Parameters show interface port-type slot/port[] pfc statistics port-type Enter the port type. slot/port [] Enter the slot/port number. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
show stack-unit stack-ports pfc details Displays the PFC configuration applied to ingress traffic on stacked ports, including PFC Operational mode on each unit with the configured priorities, link delay, and number of pause packets sent and received. Syntax Parameters show stack-unit {all | stack-unit} stack-ports {all | portnumber} pfc details stack-unit Enter the stack unit. port-number Enter the port number. Command Modes EXEC Privilege Command History This guide is platform-specific.
bandwidth-percentage Configure the bandwidth percentage allocated to priority traffic in port queues. Syntax bandwidth-percentage percentage To remove the configured bandwidth percentage, use the no bandwidthpercentage command. Parameters percentage (Optional) Enter the bandwidth percentage. The percentage range is from 1 to 100% in units of 1%. Defaults none Command Modes QOS-POLICY-OUT-ETS Command History This guide is platform-specific.
sum of configured bandwidth allocation to dot1p priority traffic in all ETS priority groups must be 100%. Allocate at least 1% of the total bandwidth to each priority group and queue. If bandwidth is assigned to some priority groups but not to others, the remaining bandwidth (100% minus assigned bandwidth amount) is equally distributed to nonstrict-priority groups which have no configured scheduler. Related Commands • qos-policy-output ets — creates a QoS output policy.
Parameters pfc-queues Enter the pfc-queue range. To disable DCB, use the no dcb enable command. The range is from 1 or 2. Defaults None Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. Version The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module. priority-list Configure the 802.
priority-group To use with an ETS output policy, create an ETS priority group. Syntax priority-group group-name To remove the priority group, use the no priority-group command. Parameters group-name Enter the name of the ETS priority group. The maximum is 32 characters. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
You must fully define the priority-group profile with a PGID and priorities before mapping it to a QoS policy because the PGID and priorities are unique keys of the traffic class group (TCG) that define the QoS policy. You must disable the DCB output policy before changing the PGID or priorities of a priority group assigned to that DCB output policy. Related Commands • priority-list — configures the 802.1p priorities for an ETS output policy. • set-pgid — configures the priority-group.
You can only associate output QoS policy profiles with the priority groups in the DCB output profile context; output QoS policy profiles are not permitted on output policy-maps. WRED, ECN, rate shaping, and rate limiting are not supported in output policies because DCBx does not negotiate these parameters with peer devices. You can apply a QoS output policy with WRED and/or rate shaping on a DCBx CIN-enabled interface.
Related Commands • priority-list — configures the 802.1p priorities. scheduler Configure the method used to schedule priority traffic in port queues. Syntax scheduler value To remove the configured priority schedule, use the no scheduler command. Parameters value Enter schedule priority value. The range: strict: strict-priority traffic is serviced before any other queued traffic. Defaults Weighted Elastic Round Robin (WERR) scheduling is used to queue priority traffic.
• bandwidth-percentage — bandwidth percentage allocated to priority traffic in port queues. show interface ets Displays the ETS configuration applied to egress traffic on an interface, including priority groups with priorities and bandwidth allocation. Syntax Parameters show interface port-type slot/port[] ets {summary | detail} port-type slot/ port[] ets Enter the port-type slot and port ETS information.
6 7 - - Remote Parameters : ------------------Remote is disabled Local Parameters : -----------------Local is enabled TC-grp Priority# Bandwidth TSA -----------------------------------------------0 1 0,1,2 100% ETS 2 3 0 % SP 3 4,5,6,7 0 % SP 4 5 6 7 Oper status is init ETS DCBX Oper status is Down State Machine Type is Asymmetric Conf TLV Tx Status is enabled Reco TLV Tx Status is enabled 0 Input Conf TLV Pkts, 1955 Output Conf TLV Pkts, 0 Error Conf TLV Pkts 0 Input Reco TLV Pkts, 1955 Output Reco TLV
-----------------------------------------------0 1 0,1,2 100% ETS 2 3 0 % SP 3 4,5,6,7 0 % SP 4 5 6 7 Oper status is init ETS DCBX Oper status is Down State Machine Type is Asymmetric Conf TLV Tx Status is enabled Reco TLV Tx Status is enabled 0 Input Conf TLV Pkts, 1955 Output Conf TLV Pkts, 0 Error Conf TLV Pkts 0 Input Reco TLV Pkts, 1955 Output Reco TLV Pkts, 0 Error Reco TLV Pkts Dell# show interfaces tengigabitethernet 1/1 ets detail Interface TenGigabitEthernet 1/1 Max Supported TC Groups is 4 Number
1 13% ETS 2 13% ETS 3 13% ETS 4 12% ETS 5 12% ETS 6 12% ETS 7 12% ETS Oper status is init Conf TLV Tx Status is disabled Traffic Class TLV Tx Status is disabled 0 Input Conf TLV Pkts, 0 Output Conf TLV Pkts, 0 Error Conf TLV Pkts 0T LIVnput Traffic Class TLV Pkts, 0 Output Traffic Class TLV Pkts, 0 Error Traffic Class Pkts Example (Detail) Dell(conf)# show interfaces tengigabitethernet 1/1 ets detail Interface TenGigabitEthernet 1/1 Max Supported TC Groups is 4 Number of Traffic Classes is 8 Admin mode is
1 13% ETS 2 13% ETS 3 13% ETS 4 12% ETS 5 12% ETS 6 12% ETS 7 12% ETS Oper status is init Conf TLV Tx Status is disabled Traffic Class TLV Tx Status is disabled 0 Input Conf TLV Pkts, 0 Output Conf TLV Pkts, 0 Error Conf TLV Pkts 0 Input Traffic Class TLV Pkts, 0 Output Traffic Class TLV Pkts, 0 Error Traffic Class TLV Pkts show qos priority-groups Displays the ETS priority groups configured on the switch, including the 802.1p priority classes and ID of each group.
Parameters stack-unit Enter the stack unit identification. port-number Enter the port number. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example (Summary) Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.
7 8 - - DCBX Commands The following DCBX commands are supported on the Dell Networking OS. advertise dcbx-app-tlv Configure DCBX to send iSCSI TLV advertisements. S4820T Syntax advertise dcbx-app-tlv iscsi To disable DCBX iSCSI TLV advertisements, use the no advertise dcbx-apptlv iscsi command. Defaults Enabled Command Modes PROTOCOL LLDP Command History This guide is platform-specific.
Parameters {fcoe | iscsi} Enter the application priority TLVs, where: • fcoe: enables the advertisement of FCoE in application priority TLVs. • iscsi: enables the advertisement of iSCSI in application priority TLVs. Defaults Application priority TLVs are enabled to advertise FCoE and iSCSI. Command Modes PROTOCOL LLDP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command Modes PROTOCOL LLDP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.
• manual: configures the port to operate only on administer-configured DCB parameters. The port does not accept a DCB configuration received form a peer or a local configuration source. Defaults Manual Command Modes INTERFACE PROTOCOL LLDP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Defaults Auto Command Modes INTERFACE PROTOCOL LLDP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.
Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.
Usage Information This command is available at the global level only. iscsi priority-bits Configure the iSCSI priority advertised for the iSCSI protocol in application priority TLVs. Syntax iscsi priority-bits priority-bitmap To remove the configured iSCSI priority, use the no iscsi priority-bits command. Parameters priority-bitmap Enter the priority-bitmap range. The range is from 1 to FF. Defaults 0x10 Command Modes PROTOCOL LLDP Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.2.(0.0) Down status messages added. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.
Field Description Operational Version Example Local DCBX Status: DCBX Max Version Supported Highest DCBX version supported in Control TLVs. Local DCBX Status: Sequence Number Sequence number transmitted in Control TLVs. Local DCBX Status: Acknowledgment Number Acknowledgement number transmitted in Control TLVs. Local DCBX Status: Protocol State Current operational state of the DCBX protocol: ACK or INSYNC.
P-PFC Configuration TLV enabled p-PFC Configuration TLV disabled F-Application priority for FCOE enabled f-Application Priority for FCOE disabled I-Application priority for iSCSI enabled i-Application Priority for iSCSI disabled ----------------------------------------------------------Interface TenGigabitEthernet 0/49 Remote Mac Address 00:00:00:00:00:11 Port Role is Auto-Upstream DCBX Operational Status is Enabled Is Configuration Source? TRUE Local DCBX Compatibility mode is CEE Local DCBX Configured mod
Command Modes Command History Usage Information CONFIGURATION INTERFACE Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S4810 and S6000 platforms. A DCB map is a template used to configure DCB parameters and apply them on converged Ethernet interfaces. DCB parameters include priority-based flow control (PFC) and enhanced traffic selection (ETS). To display the PFC and ETS settings in DCB maps, enter the show qos dcb-map command.
dot1p3_groupnum dot1p4_groupnum dot1p5_groupnum dot1p6_groupnum dot1p7_groupnum Defaults None Command Modes DCB MAP Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S4810, S6000 platforms. PFC and ETS settings are not pre-configured on Ethernet ports. You must use the dcb-map command to configure different groups of 802.1p priorities with PFC and ETS settings. Using the priority-pgid command, you assign each 802.
pfc mode on Enable the PFC configuration on the port so that the priorities are included in DCBX negotiation with peer PFC devices. Syntax pfc mode on To disable the PFC configuration, use the no pfc mode on command. Defaults PFC mode is on. Command Modes DCB MAP Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the MXL 10/40GbE Switch with the FC Flex IO module.
priority-group bandwidth pfc Configure the ETS bandwidth allocation and PFC mode used to manage port traffic in an 802.1p priority group. Parameters priority-group group-num Enter the keyword priority-group followed by the number of an 802.1p priority group. Use the prioritypgid command to create the priority groups in a DCB map. bandwidth percentage Enter the keyword bandwidth followed by a bandwidth percentage allocated to the priority group. The range of valid values is 1 to 100.
If a priority group does not use its allocated bandwidth, the unused bandwidth is made available to other priority groups. To remove a priority-group configuration in a DCB map, enter the no prioritygroup bandwidth pfc command. By default, equal bandwidth is assigned to each dot1p priority in a priority group. Use the bandwidth parameter to configure the bandwidth percentage assigned to a priority group.
show qos dcb-map Display the DCB parameters configured in a specified DCB map. Syntax Parameters Command Modes Command History Usage Information show qos dcb-map map-name map-name • • Displays the PFC and ETS parameters configured in the specified map. EXEC EXEC Privilege Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S4810 and S6000 platforms. 9.3(0.0) Introduced on the FC Flex IO module installed in the MXL 10/40GbE Switch.
PfcMode:ON -------------------PG:0 TSA:ETS BW:50 PFC:OFF Priorities:0 1 2 4 5 6 7 PG:1 TSA:ETS Priorities:3 BW:50 PFC:ON dcb pfc-shared-buffer-size Configure the maximum amount of shared buffer size for PFC packets in kilobytes. You must configure the shared buffer size to be less than the total PFC buffer size.
Dell(conf)#dcb pfc-shared-buffer-size 2000 %ERROR: pfc shared buffer size configured cannot accommodate existing buffer requirement in the system. Example Dell(conf)#dcb pfc-shared-buffer-size 5000 dcb-buffer-threshold Configure the profile name for the DCB buffer threshold. This utility is supported on the S4810, S4820T, and S6000 platforms. S4820T Syntax Parameters dcb buffer—threshold profile-name profile-name Enter the name of the profile, which can be a string of up to 32 characters in length.
Parameters priority Specify the priority of the queue for which the buffer space settings apply value Enter a number in the range of 0 to 7 to denote the priority to be allocated to the dynamic buffer control mechanism buffer-size Ingress buffer size size Size of the ingress buffer in KB. Enter a number in the range of 0 to 7787. The default is 45 KB. pausethreshold Buffer limit for pause frames to be sent thresholdvalue Buffer limit at which the port sends the pause to peer in KB.
policy is applied, then the configuration for those priorities are pre-designed. However, if the peer-provided priorities are applied, although a DCB input policy is present, the peer-provided priorities become effective for buffer configuration. This method of configuration provides an easy and flexible technique to accommodate both administratively-configured and peer-configured priorities.
thresholdvalue Buffer limit at which the port sends the pause to peer in KB. Enter a number in the range of 0 to 7787. The default is 10 KB. resume-offset Buffer offset limit for resuming in KB thresholdvalue Buffer offset limit at which the port resumes the peer in KB. Enter a number in the range of 1 to 7787. The default is 10 KB. sharedthresholdweight Buffer shared threshold weight size Weightage of the priorities on the shared buffer size in the system. Enter a number in the range of 0 to 9.
Dell(conf-qos-policy-buffer)#queue 0 pause no-drop buffer-size 128000 pause-threshold 103360 resume-threshold 83520 Dell(conf-qos-policy-buffer)# queue 4 pause no-drop buffer-size 128000 pause-threshold 103360 resume-threshold 83520 dcb-policy buffer-threshold (Interface Configuration) Assign the DCB policy to the DCB buffer threshold profile on interfaces. This setting takes precedence over the global buffer-threshold setting.
dcb-policy dcb-buffer-threshold (Global Configuration) Assign the DCB policy to the DCB buffer threshold profile on stack ports that applies globally throughout the system. This utility is supported on the and S4820T platforms. This command is not supported on the S6000 platform because it does not contain stack ports.
Parameters Command Modes name Enter the name of the profile, which can be a string of up to 32 characters in length. EXEC EXEC Privilege Command History Usage Information Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S6000 platform.
Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S6000 platform. Configure the maximum buffer available for PFC traffic. You can choose to increase or decrease the buffer size that is currently allocated in the system by default.
Example Field Description Profile name Name of the DCB buffer threshold profile Priority The priority of the queue for which the buffer space settings apply buffer-size Ingress buffer size pause-threshold-value Buffer limit at which the port sends the pause to peer in KB. resume-threshold-value Buffer offset limit at which the port resumes the peer in KB.
The following table describes the output fields displayed for the show interface pfc buffer-threshold command: Field Description queue Number of the queue lossless Whether the queue is a lossy or lossless queue for which buffer threshold is configured buffer-size Ingress buffer size pause-threshold-value Buffer limit at which the port sends the pause to peer in KB. resume-threshold-value Buffer offset limit at which the port resumes the peer in KB.
thresholds for the buffer. This method of configuration enables you to effectively manage and administer the behavior of lossless queues. Example Dell(conf)#dcb pfc-queues 4 dcb {ets | pfc} enable Enable priority flow control or enhanced transmission selection on interface. Syntax dcb {ets | pfc} enable • To disable ETS on interface, use “no dcb ets enable” command. • To disable PFC on interface, use “no dcb pfc enable” command.
14 Debugging and Diagnostics The basic debugging and diagnostic commands are supported by the Dell Networking Operating System. This chapter contains the following sections: • Diagnostic and Monitoring Commands • Offline Diagnostic Commands • Hardware Commands Diagnostics and Monitoring Commands The following section describes the diagnostics and monitoring commands. For similar commands, refer to the Control and Monitoring chapter. logging coredump stack-unit Enable coredump on a stack.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. The Kernel core dump can be large and may take up to 5 to 30 minutes to upload. Dell Networking OS does not overwrite application core dumps so you should delete them as necessary to conserve space on the flash; if the flash is out of memory, the coredump is aborted. On the S-Series, if the FTP server is not reachable, the application coredump is aborted.
level1 Enter the keyword Level1 to run Level 1 diagnostics. Level 1 diagnostics is a smaller set of diagnostic tests with support for automatic partitioning. They perform status/self test for all the components on the board and test their registers for appropriate values. In addition, they perform extensive tests on memory devices (for example, SDRAM, flash, NVRAM, EEPROM, and CPLD) wherever possible. There are no tests on 10G links. At this level, stack ports are shut down automatically.
offline stack-unit Place a stack unit in the offline state. Syntax Parameters offline stack-unit number number Enter the stack-unit id. Range: S4820T — 0 to 11 Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
online stack-unit Place a stack unit in the online state. Syntax Parameters online stack-unit number number Enter the stack-unit number. The S4820T range is from 0 to 11. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Hardware Commands These commands display information from a hardware sub-component or ASIC. clear hardware stack-unit Clear statistics from selected hardware components.
Related Commands Version Description 8.3.11.0 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. show hardware stack-unit — displays the data plane or management plane input and output statistics of the designated component of the designated stack member. clear hardware system-flow Clear system-flow statistics from selected hardware components.
Related Commands show hardware stack-unit — displays the data plane or management plane input and output statistics of the designated component of the designated stack member. clear hardware vlan-counters Clear VLAN statistics. Syntax Parameters clear hardware vlan-couters vlan-id vlan-id Enter the interface VLAN number. The range is from 1 to 4094. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific.
Usage Information Version Description 8.3.11.0 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. This command enables a hardware watchdog mechanism that automatically reboots an Dell Networking OS switch/ router with a single unresponsive unit. This behavior is a last-resort mechanism intended to prevent a manual power cycle. show hardware layer2 Display Layer 2 ACL or eg data for the selected stack member and stack member port-pipe.
show hardware layer3 Display Layer 3 ACL or QoS data for the selected stack member and stack member port-pipe. Syntax Parameters show hardware layer3 {acl | qos} stack-unit number port-set 0–0 acl | qos Enter either the keyword acl or the keyword qos to select between ACL or QoS data. stack-unit number Enter the keywords stack-unit then a number to select a stack ID. The range is from 0 to 11. port-set 0–0 Enter the keyword port-set with a port-pipe number. The range is from 0 to 0.
Parameters stack-unit stack-unit {commandoption} Enter the keywords stack-unit to select a particular stack member and then enter one of the following command options to display a collection of data based on the option entered. The range is 0 to 11. buffer Enter the keyword buffer. To display the total buffer statistics for the stack unit, enter the keyword totalbuffer. To display buffer statistics for a all interface, enter the keyword interface followed by the keyword all.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Replaced the keyword port with interface. 9.7(0.0) Introduced on the S6000-ON. 9.2(0.2) Modified the drops keyword range, unit keyword range and added the buffer and cpu management statistics options. 9.0.2.
Example (Drops Unit) Dell#sh hard stack-unit 1 drops unit 0 PortNumberIngress Drops IngMac Drops Total Mmu Drops 1 0 0 0 2 0 0 0 3 0 0 0 4 0 0 0 EgMac Drops Egress Drops 0 0 0 0 0 0 0 0 Dell# Example (PortStats) Dell#show hardware stack-unit 1 unit 0 ena/ speed/ link auto STP loop port link duplex scan neg? state pause back ge0 down SW Yes Block ge1 !ena SW Yes Block ge2 !ena SW Yes Block ge3 !ena SW Yes Block ge4 !ena SW Yes Forward ge5 !ena SW Yes Forward ge6 !ena SW Yes Forward ge7 !ena SW Yes Forward
0x0060804c 0x0060904c 0x0060a04c 0x0060b04c 0x0060c04c 0x0060d04c 0x0060e04c 0x0060f04c 0x0061004c 0x0061104c 0x0061204c 0x0061304c 0x0061404c 0x0061504c 0x0061604c 0x0061704c 0x0061804c 0x0061904c 0x0061a04c 0x0061b04c 0x0061c04c 0x00780000 0x0e700102 0x0e701102 0x0e702102 0x0e703102 0x0e704102 0x0e705102 0x0e706102 0x0e707102 0x0e708102 0x0e709102 0x0e70a102 0x0e70b102 0x0e70c102 0x0e70d102 0x0e70e102 0x0e70f102 0x0e710102 0x0e711102 0x0e712102 0x0e713102 0x0e714102 0x0e715102 0x0e716102 0x0e717102 0x0e71
0x0b70a001 BCAST_STORM_CONTROL.
TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX - 1519 to 2047 Byte Frame Counter 2048 to 4095 Byte Frame Counter 4096 to 9216 Byte Frame Counter Good Packet Counter Packet/Frame Counter Unicast Frame Counter Multicast Frame Counter Broadcast Frame Counter Byte Counter Control Frame Counter Pause Control Frame Counter Oversized Frame Counter Jabber Counter VLAN Tag Frame Counter Double VLAN Tag Frame Counter RUNT Frame Counter Fragment Counter
RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX 628 - Multicast Frame Counter Broadcast Frame Counter Byte Counter Control Frame Counter Pause Control Frame Counter Oversized Frame Counter Jabber Frame Counter VLAN Tag Frame Counter Double VLAN Tag Frame Counter RUNT Frame Counter Fragment Counter VLAN Tagged Packets Ingress Dropped Packet MTU Check Error Frame C
TX TX TX TX TX TX TX TX TX TX TX Example (Details) - Debug Debug Debug Debug Debug Debug Debug Debug Debug Debug Debug Counter Counter Counter Counter Counter Counter Counter Counter Counter Counter Counter 1 2 3 4 5 6 7 8 9 10 11 0 0 0 0 0 0 0 0 0 0 0 Dell#show hardware stack-unit 1 unit 1 details ****************************************************** The total no of FP & CSF Devices in the Card is 2 The total no of FP Devices in the Card is 2 The total no of CSF Devices in the Card is 0 The number o
The linkStatus of Hg Port 26 is FALSE The linkStatus of Hg Port 27 is FALSE !------------------ output truncated ---------------! Example (Total-Buffer) Dell#show hardware stack-unit 1 buffer total-buffer Example displaying queue range Dell#show hardware stack-unit 0 buffer unit 0 interface all queue 6 buffer-info Buffer Stats for Front End Ports ================================ ----- Buffer Stats for Interface Te 1/0 Queue 6 ----Maximum Shared Limit: 7667 Default Packet Buffer allocate for the Queue: 8
show hardware buffer interface Display buffer statistics for a specific interface. Syntax Parameters Command Modes show hardware buffer inteface interface{priority-group { id | all } | queue { id| all} ] buffer-info interface interface Enter any of the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
0 0 - 0 61440 0 STATIC 174 0 Dell# Example displaying queue range Dell#show hardware buffer interface tengigabitethernet 1/1 queue all buffer-info ----- Buffer Stats for Interface Te 1/1 Queue 0 ----Maximum Shared Limit: 29514 Default Packet Buffer allocate for the Queue: 8 Used Packet Buffer: 0 ----- Buffer Stats for Interface Te 1/1 Queue 1 ----Maximum Shared Limit: 29514 Default Packet Buffer allocate for the Queue: 8 Used Packet Buffer: 0 ----- Buffer Stats for Interface Te 1/1 Queue 2 ----Maxi
show hardware buffer-stats-snapshot Displays buffer statistics tracking resource information for a specific interface. Syntax Parameters Command Modes show hardware buffer-stats-snapshot resource interface interface{priority-group { id | all } | queue { ucast{id | all} { mcast {id | all} | all} buffer-statssnapshot unit number Display the historical snapshot of buffer statistical values unit Enter the keyword unit along with a port-pipe number. The range is from 0 to 0.
Example displaying egress queuelevel snapshot for both unicast and multicast packets for the specific interface Dell# show hardware buffer-stats-snapshot resource interface fortyGigE 0/0 queue all Unit 0 unit: 0 port: 1 (interface Fo 0/0) --------------------------------------Q# TYPE Q# TOTAL BUFFERED CELLS --------------------------------------UCAST 0 0 UCAST 1 0 UCAST 2 0 UCAST 3 0 UCAST 4 0 UCAST 5 0 UCAST 6 0 UCAST 7 0 UCAST 8 0 UCAST 9 0 UCAST 10 0 UCAST 11 0 MCAST 0 0 MCAST 1 0 MCAST 2 0 MCAST 3 0 MC
Example displaying egress queuelevel snapshot for multicast packets for the specific interface Dell#show hardware buffer-stats-snapshot resource interface fortyGigE 0/0 queue mcast 3 Unit 1 unit: 0 port: 1 (interface Fo 0/0) --------------------------------------Q# TYPE Q# TOTAL BUFFERED CELLS --------------------------------------MCAST 3 0 Dell#show hardware buffer-stats-snapshot resource interface fortyGigE 0/0 queue mcast all Unit 0 unit: 0 port: 1 (interface Fo 0/0) ------------------------------------
Parameters Defaults Command Modes Command History counters Enter the keywords counters to display counter value for the specified stack-member the port-pipe. interface interface Enter any of the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
RX - Double VLAN Tag Frame Counter RX - RUNT Frame Counter RX - Fragment Counter RX - VLAN Tagged Packets RX - Ingress Dropped Packet RX - MTU Check Error Frame Counter RX - PFC Frame Priority 0 RX - PFC Frame Priority 1 RX - PFC Frame Priority 2 RX - PFC Frame Priority 3 RX - PFC Frame Priority 4 RX - PFC Frame Priority 5 RX - PFC Frame Priority 6 RX - PFC Frame Priority 7 RX - Debug Counter 0 RX - Debug Counter 1 RX - Debug Counter 2
Example displaying internal drops for the specific interface 638 Version Description 9.2(0.2) Modified the drops keyword range, unit keyword range and added the buffer and cpu management statistics options. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.5 Added i2c statistics and sata-interfaces statistics. 8.3.11.4 Added user port information. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series.
TTL Threshold Drops INVALID VLAN CNTR Drops L2MC Drops PKT Drops of ANY Conditions Hg MacUnderflow TX Err PKT Counter --- Error counters--Internal Mac Transmit Errors Unknown Opcodes Internal Mac Receive Errors : : : : : : 0 0 0 0 0 0 : 0 : 0 : 0 show hardware stack-unit buffer-stats-snapshot (Total Buffer Information) View the buffer statistics tracking resource information depending on the type of buffer information, such as device-level details, port-level counters, queue-based snapshots, or priority
Command History Usage Information Version Description 9.8(0.0) Added the keyword interface all. 9.7(0.0) Introduced on the S6000-ON. 9.6(0.0) Introduced on the S5000. 9.3(0.0) Introduced on the S6000, S4810, and S4820T. The following information is displayed based on the buffer-info type, such as device-level details, queue-based snapshots, or priority group-level snapshot in the egress and ingress direction of traffic: • Device-ingress – Displays total buffer accounting usage for the unit.
--------------------------------------MCAST 3 0 Unit 1 unit: 3 port: 25 (interface Fo 1/168) --------------------------------------Q# TYPE Q# TOTAL BUFFERED CELLS --------------------------------------MCAST 3 0 Unit 1 unit: 3 port: 29 (interface Fo 1/172) --------------------------------------Q# TYPE Q# TOTAL BUFFERED CELLS --------------------------------------MCAST 3 0 Unit 1 unit: 3 port: 33 (interface Fo 1/176) --------------------------------------Q# TYPE Q# TOTAL BUFFERED CELLS -----------------------
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series.
, FPF4=0x00 MASK=0x00000000 00000000 00000000 ffffffff ffff0000 00000000 00000000 , 0x00 action={act=Drop, param0=0(0x00), param1=0(0x00)}, action={act=CosQCpuNew, param0=7(0x07), param1=0(0x00)}, action={act=CopyToCpu, param0=0(0x00), param1=0(0x00)}, action={act=UpdateCounter, param0=1(0x01), param1=0(0x00)}, meter=NULL, counter={idx=2, mode=0x01, entries=1} ################# FP Entry for redirecting GVRP traffic to RSM ########### EID 2044: gid=1, slice=15, slice_idx=0x03, prio=0x7fc, flags=0x82, Install
Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced this command.
Dynamic Host Configuration Protocol (DHCP) 15 Dynamic host configuration protocol (DHCP) is an application layer protocol that dynamically assigns IP addresses and other configuration parameters to network end-stations (hosts) based on the configuration policies the network administrators determine. The Dell Networking operating system supports the basic DHCP commands on this platform.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. debug ipv6 dhcp To enable debug logs for DHCPv6 relay agent transactions. Syntax debug ipv6 dhcp To disable the debug logs for dhcpv6 relay agent transactions, use the debug ipv6 dhcp command. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. disable Disable the DHCP server. S4820T Syntax disable DHCP Server is disabled by default. To enable the system to be a DHCP server, use the no disable command.
dns-server Assign a DNS server to clients based on address pool. S4820T Syntax Parameters dns-server address [address2...address8] address Enter a list of DNS servers that may service clients on the subnet. You may list up to eight servers, in order of preference. Defaults none Command Modes DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series.
Version Description 8.2.1.0 Introduced on the C-Series and S-Series. hardware-address For manual configurations, specify the client hardware address. S4820T Syntax Parameters hardware-address address address Enter the hardware address of the client. Defaults none Command Modes DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. netbios-name-server Specify the NetBIOS Windows Internet Naming Service (WINS) name servers, in order of preference, that are available to Microsoft Dynamic Host Configuration Protocol (DHCP) clients. S4820T Syntax Parameters netbios-name-server address [address2...address8] address Enter the address of the NETBIOS name server.
Parameters type Enter the NETBIOS node type: • Broadcast: Enter the keyword b-node. • Hybrid: Enter the keyword h-node. • Mixed: Enter the keyword m-node. • Peer-to-peer: Enter the keyword p-node. Defaults Hybrid Command Modes DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. pool Create an address pool. S4820T Syntax Parameters pool name name Enter the address pool’s identifying name. Defaults none Command Modes DHCP Command History This guide is platform-specific.
show ip dhcp binding Display the DHCP binding table. S4820T Syntax show ip dhcp binding Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. show ip dhcp conflict Display the address conflict log. S4820T Syntax Parameters show ip dhcp conflict address address Display a particular conflict log entry.
show ip dhcp server Display the DHCP server statistics. S4820T Syntax show ip dhcp server statistics Defaults none Command Modes EXEC Privilege Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series.
Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the E-Series. 8.2.1.0 Introduced on the C-Series and S-Series. arp inspection-trust — specifies a port as trusted so that ARP frames are not validated against the binding table.
clear ip dhcp snooping Clear the DHCP binding table. Syntax Parameters clear ip dhcp snooping {binding | source-address-validation discard-counters [interface interface]} binding Clears the binding table. sourceaddressvalidation discardcounters Clears discard counters from all the interfaces configured with IP Source Guard. interface interface (OPTIONAL) Specifies an interface to clear the discard counters.
Example Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the E-Series. 8.2.1.0 Introduced on the C-Series and S-Series.
ip dhcp relay Enable Option 82. S4820T Syntax Parameters ip dhcp relay information-option [remote-id | trust-downstream] remote-id Configure the system to enable the remote-id string in option-82. trustdownstream Configure the system to trust Option 82 when it is received from the previous-hop router. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.2.(0.0) Introduced on the S4810 and S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.1.0 Introduced on the E-Series. 8.2.1.0 Introduced on the C-Series and S-Series on Layer 2 interfaces. 7.8.1.0 Introduced on the C-Series and S-Series on Layer 3 interfaces.
ipv6 dhcp snooping vlan Enable ipv6 DHCP Snooping on VLAN or range of VLANs. Syntax [no] ip dhcp snooping vlan vlan-id To disable the ipv6 dhcp snooping on VLAN basis or range of VLAN, use the no ipv6 dhcp snooping vlan command. Parameters vlan-id Enter the name of a VLAN id or list of the VLANs to enable DHCP Snooping. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific.
Defaults Command Modes Command History slot/port Enter the slot and port number of the interface. lease time Enter the keyword lease then the amount of time the IP address are leased. The range is from 1 to 4294967295. none • • EXEC EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
ipv6 ipv6address Enter the keyword ipv6 then the IPv6 address that is leased to the client. interface type Enter the keyword interface then the type of interface to which the host is connected: • For an 10/100 Ethernet interface, enter the keyword fastethernet. • For a Gigabit Ethernet interface, enter the keyword gigabitethernet. • For a Ten-Gigabit Ethernet interface, enter the keyword tengigabitethernet. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the E-Series. 7.8.1.
ip dhcp snooping database renew Renew the binding table. S4820T Syntax ip dhcp snooping database renew Defaults none Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000.
Version Description 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. ip dhcp snooping trust Configure an interface as trusted. S4820T Syntax [no] ip dhcp snooping trust Defaults Untrusted Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.
Version Description 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. ip dhcp source-address-validation Enable the IP Source Guard. Syntax Parameters [no] ip dhcp source-address-validation [ipmac] [vlan vlan-id] ipmac Enable IP+MAC Source Address Validation. vlan vlan-id (OPTIONAL) SAV validates the source IP address along with the source VLAN ID against the DHCP snooping binding table.
3. Reload the system. ip dhcp relay information-option Enable Option 82. S4820T Syntax Parameters ip dhcp relay information-option [trust-downstream] [vpn] trustdownstream Configure the system to trust Option 82 when it is received from the previous-hop router. vpn Enter the keyword vpn to add VPN/VRF related sub-option to relay agent information Option 82. NOTE: Adds the VPN/VRF related sub-options into the relay agent information option(82).
ip dhcp snooping verify mac-address Validate a DHCP packet’s source hardware address against the client hardware address field (CHADDR) in the payload. S4820T Syntax [no] ip dhcp snooping verify mac-address Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Version Description 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. ip helper-address Configures the destination broadcast address or the host address for DHCP server requests. S4820T Syntax ip helper-address [vrf vrf-name] ip-address To disable the destination broadcast address or the host address for DHCP server requests, use the ip helper-address [vrf vrf-name] ip-address command.
Parameters ipv6-address Enter the keywordipv6–address through which the server address can be reached. Default Disabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S4810, S4820T, S6000, S6000–ON, Z9000, and Z9500.
• • Defaults Command Modes Command History For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. For a port channel interface, enter the keywords portchannel then a number. The range is from 1 to 128. none • • EXEC EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
ipmac-vlan sav access-list on Port-channel 10 on stack-unit 0 Total cam count 5 permit host 0.0.0.0 host 00:00:00:00:00:00 count (0 packets) permit vlan 10 host 1.1.1.1 host 00:00:00:00:01:01 count (0 packets) permit vlan 10 host 1.1.1.2 host 00:00:00:00:01:02 count (0 packets) permit vlan 10 host 1.1.1.3 host 00:00:00:00:01:03 count (0 packets) ipmac-vlan sav access-list on Port-channel 10 on stack-unit 1 Total cam count 5 permit host 0.0.0.0 host 00:00:00:00:00:00 count (0 packets) permit vlan 10 host 1.
deny access-list on Port-channel 10 on stack-unit 2 Total cam count 1 deny vlan 10 count (0 packets) NOTE: The output for port-channel interfaces does not display the physical interface. If the LAG member interfaces belong to different stack-units, the counters are displayed per stack-unit for that port channel. show ipv6 dhcp snooping Display the DHCPv6 snooping binding database.
Commands to Configure DNS To configure the Domain Names Systems (DNS) on the system, use the following commands: ip name-server Configures the name server IP addresses for VRF. Using this command, you can configure up to a maximum of six IP addresses per VRF. S4820T Syntax ip name-server [vrf vrf-name] ip-address [ip-address2] [ipaddress3] [ip-address4] [ip-address5] [ip-address6] To undo the name server ip address configuration for VRF, use the no ip nameserver [vrf vrf-name] ip-address command.
ip domain-name Configures the default domain corresponding to a specific VRF. This domain is appended to the in complete DNS requests corresponding to the specified VRF. S4820T Syntax ip domain-name [vrf vrf-name] name To undo the domain name configuration corresponding to a specific VRF, use the no ip domain-name [vrf vrf-name] name command. Parameters vrf vrf-name (Optional) Enter the key word vrf and then the name of the VRF to configure the domain corresponding to that VRF.
Parameters vrf vrf-name (Optional) Enter the key word vrf and then the name of the VRF to add a domain name to the DNS list corresponding to that VRF. name Enter the name of the domain to be appended to the DNS list corresponding to the VRF. Defaults None Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Defaults None Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Introduced on the S-Series and Z-Series.
Usage Information Use this command to delete one or all dynamically learned host table entries corresponding to a specific VRF.
Equal Cost Multi-Path (ECMP) 16 Equal cost multi-path (ECMP) is supported on the Dell Networking OS. ecmp-group Provides a mechanism to monitor traffic distribution on an ECMP link bundle. A system log is generated when the standard deviation of traffic distribution on a member link exceeds a defined threshold. S4820T Syntax ecmp-group {ecmp-group-id interface interface | link-bundlemonitor} To remove the selected interface, use the ecmp-group no interface command.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. Using CONFIGURATION mode, create an ECMP group ID. You can then assign interfaces to the ECMP group using CONFIGURATION ECMP-GROUP mode.
ecmp crc16 | crc16cc | crc32MSB | crc32LSB | crcupper | dest-ip | lsb | xor1 | xor2 | xor4 | xor8 | xor16 hg {crc16 | crc16cc | crc32MSB | crc32LSB | xor1 | xor2 | xor4 | xor8 | xor16} stack-unit stack-unitnumber | portset port-pipe TeraScale and ExaScale Only: Enter the keyword ecmp then one of the following options: • crc16: Use CRC16_BISYNC — 16 bit CRC16-bisync polynomial (default) • crc16cc: Use CRC16_CCITT — 16 bit CRC16 using CRC16-CCITT polynomial • crc32MSB: Use CRC32_UPPER — MSB 16 bits of
Enter the keywords port-set port-pipe then the port pipe number. The range is from 0 to 5. hg-seed seedvalue stackunit Z-Series only: Enter the keywords hg-seed then the hash algorithm seed value. The range is from 0 to 2147483646. Enter the keywords stack-unit then the stack unit number. Enter the keywords port-set then the stack-unit port-pipe number. lag hash algorithm Z-Series only: Enter the keywords hg-seed . The range is from 0 to 47.
Usage Information Version Description 7.7.1.1 Added the nh-ecmp option. To ensure that CRC is not used for LAG, set the default hash-algorithm method on ExaScale systems. For example,hash-algorithm ecmp xor lag checksum nh-ecmp checksum. The hash value calculated with the hash-algorithm command is unique to the entire chassis. The hash algorithm command with the stack—unit option changes the hash for a particular stack—unit by applying the mask specified in the IPSA and IPDA fields.
hash-algorithm ecmp Change the hash algorithm used to distribute traffic flows across an ECMP (equal-cost multipath routing) group. S4820T Term heading Description heading Syntax hash-algorithm ecmp {crc-upper} | {dest-ip} | {lsb} To return to the default hash algorithm, use the no hash-algorithm ecmp command. Parameters Defaults crc-upper Uses the upper 32 bits of the key for the hash computation. The default is crc-lower. dest-ip Uses the destination IP for ECMP hashing. The default is enabled.
Term heading Description heading The different hash algorithms are based on the number of ECMP group members and packet values. The default hash algorithm yields the most balanced results in various test scenarios, but if the default algorithm does not provide satisfactory distribution of traffic, use this command to designate another algorithm. When a member leaves or is added to the ECMP group, the hash algorithm is recalculated to balance traffic across the members.
Usage Information Deterministic ECMP sorts ECMPs in order even though RTM provides them in a random order. However, the hash algorithm uses as a seed the lower 12 bits of the chassis MAC, which yields a different hash result for every chassis. This behavior means that for a given flow, even though the prefixes are sorted, two unrelated chassis select different hops. FTOS provides a CLI-based solution for modifying the hash seed to ensure that on each configured system, the ECMP selection is same.
Version Description 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.10.0 Introduced on the S4810. Usage Information You must save the new ECMP settings to the startup-config (write-mem) then reload the system for the new settings to take effect. Related Commands show ip cam stack-unit – Display content-addressable memory (CAM) entries for an S-Series switch. ip ecmp weighted Enables weighted ECMP calculations.
link-bundle-distribution trigger-threshold Provides a mechanism to set the threshold to trigger when traffic distribution begins being monitored on an ECMP link bundle. S4820T Syntax link-bundle-distribution trigger-threshold [percent] To exit from ecmp group mode, use the exit command. Parameters percent Indicate the threshold value when traffic distribution starts being monitored on an ECMP link bundle. The range is from 1 to 90%. The default is 60%.
• Command History PORT-CHANNEL INTERFACE This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810.
show link-bundle distribution Display the link-bundle distribution for the interfaces in the bundle, type of bundle (LAG or ECMP), and the most recently calculated interface utilization (either bytes per second rate or maximum rate) for each interface. S4820T Syntax show link-bundle-distribution Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
FIPS Cryptography 17 To configure federal information processing standards (FIPS) cryptography, use the following commands: fips mode enable Enable the FIPS cryptography mode on the platform. Syntax [no] fips mode enable To disable the FIPS cryptography mode, use the no fips mode enable command.
show fips status Displays the status of the FIPS mode. Syntax show fips status Defaults None Command Modes EXEC Example Dell#show fips status FIPS Mode : Disabled Dell# Dell#show fips status FIPS Mode : Enabled Dell# Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.1(0.
Example Version Description 9.1(0.0) Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on S4810. Dell#show ip ssh SSH server : enabled. SSH server version : v2. SSH server vrf : default. SSH server ciphers : 3des-cbc,aes128-cbc,aes192cbc,aes256-cbc,aes128-ctr,aes192-ctr,aes256-ctr. SSH server macs : hmac-sha1-96. SSH server kex algorithms : diffie-hellman-group14-sha1. Password Authentication : enabled. Hostbased Authentication : disabled.
ssh Open an SSH connection specifying the hostname, username, port number, and version of the SSH client. Syntax Parameters ssh {hostname|ipv4 address|ipv6 address} [-c encryption cipher|-l username|-m HMAC alogorithm|-p port-number|-v {1|2}] hostname (OPTIONAL) Enter the IP address or the hostname of the remote device. ipv4 address (OPTIONAL) Enter the IP address in dotted decimal format A.B.C.D.
Without the FIPS mode enabled: • hmac-sha1: Force ssh to use the hmac-sha1 HMAC algorithm. • hmac-shal-96: Force ssh to use the hmac-sha1–96 HMAC algorithm. • hmac-md5: Force ssh to use the hmac-md5 HMAC algorithm. • hmac-md5–96: Force ssh to use the hmac-md5–96 HMAC algorithm. With the FIPS mode enabled: • hmac-md5: Force ssh to use the hmac-md5 HMAC algorithm. • hmac-md5–96: Force ssh to use the hmac-md5–96 HMAC algorithm. • hmac-sha1: Force ssh to use the hmac-sha1 HMAC algorithm.
Related Commands Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. ip ssh server Configure an SSH server. show ip ssh client-pubkeys Display the client-public keys. Dell Networking OS supports both inbound and outbound SSH sessions using IPv4 or IPv6 addressing. Inbound SSH supports accessing the system through the management interface as well as through a physical Layer 3 interface.
Dell#ssh 10.10.10.10 -c ? 3des-cbc Force ssh aes128-cbc Force ssh aes192-cbc Force ssh aes256-cbc Force ssh aes128-ctr Force ssh aes192-ctr Force ssh aes256-ctr Force ssh Dell#ssh 10.10.10.
18 FIP Snooping To enable the FCoE Transit feature and configure FIP snooping, use the following Dell Networking Operating System commands on the S4820T platform. In a converged Ethernet network, a switch can operate as an intermediate Ethernet bridge to snoop on FIP packets during the login process on Fibre Channel over Ethernet (FCoE) forwarders (FCFs).
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. clear fip-snooping statistics Clears the statistics on the FIP packets snooped on all VLANs, a specified VLAN, or a specified port interface. S4820T Syntax Parameters clear fip-snooping statistics [interface vlan vlan-id | interface fortyGigEport-type port/slot | interface port-channel port-channel-number] vlan-id Enter the VLAN ID of the FIP packet statistics to be cleared.
debug fip snooping Enable debugging on FIP snooping. S4820T Syntax Parameters debug fip-snooping [all | acl | error | ifm | info | ipc | tx] all Enter the keyword all to enable debugging on all the options. acl Enter the keyword acl for ACL-specific debugging. error Enter the keyword error for error-specific debugging. ifm Enter the keyword ifm for IFM-specific debugging. info Enter the keyword info for information-specific debugging. ipc Enter the keyword ipc for IPC-specific debugging.
Parameters packet-type interface Enter the keyword packet-type and then the option type on which to enable debugging. The options are: • all — Enter the keyword all to enable debugging on all the options. • discovery — Enter the keyword discovery to enable debugging on FCF advertisements and ENode solicitation. • virtual-link-instantiation — Enter the keywords virtual-link-instantiation to enable debugging on FLOGI, FDISC, and FLOGO packets.
feature fip-snooping Enable FCoE transit and FIP snooping on a switch. S4820T Syntax feature fip-snooping To disable the FCoE transit feature, use the no feature fip-snooping command. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the Z9500 and S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. The maximum number of FCFs supported per FIP snooping-enabled VLAN is four.
fip-snooping max-sessions-per-enodemac Configure the maximum session limit per ENode MAC address. S4820T Syntax fip-snooping max—sessions—per—enode—mac max-sessions-value To return the configured maximum sessions to the default value, use the no fipsnooping max—sessions—per—enode—mac command. Parameters max-sessionsvalue Enter the maximum number of sessions allowed per ENode MAC address. The range is from 1 to 64.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the Z9500 and S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. The maximum number of FCFs supported per FIP snooping-enabled VLAN is four. fip-snooping port-mode fcoe-trusted Configure the port for bridge-to-bridge links.
show fip-snooping config Display the FIP snooping status and configured FC-MAP values. S4820T Syntax show fip-snooping config Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the Z9500 and S6000-ON. 8.3.19.
Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.7(0.0) Introduced on the Z9500 and S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810.
Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example 712 Version Description 9.7(0.0) Introduced on the Z9500 and S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810.
show fip-snooping statistics Display statistics on the FIP packets snooped on all interfaces, including VLANs, physical ports, and port channels. S4820T Syntax Parameters show fip-snooping statistics [interface vlan vlan-id | interface port-type port/slot | interface port-channel portchannel-number] vlan-id Enter the VLAN ID of the FIP packet statistics displays. port-type port/ slot Enter the port-type and slot number of the FIP packet statistics displays.
Field Description Number of Unicast Discovery Solicits Number of FIP-snoop unicast discovery solicit frames received on the interface. Number of FLOGI Number of FIP-snoop FLOGI request frames received on the interface. Number of FDISC Number of FIP-snoop FDISC request frames received on the interface. Number of FLOGO Number of FIP-snoop FLOGO frames received on the interface Number of ENode Keep Alives Number of FIP-snoop ENode keep-alive frames received on the interface.
Example Field Description Number of Session failures due to Hardware Config Number of session failures due to hardware configuration that occurred on the interface.
Number Number Number Number Number Number Number Number Number Number Number Number Number Number Number of of of of of of of of of of of of of of of FLOGO :0 Enode Keep Alive :0 VN Port Keep Alive :0 Multicast Discovery Advertisement :4451 Unicast Discovery Advertisement :2 FLOGI Accepts :2 FLOGI Rejects :0 FDISC Accepts :16 FDISC Rejects :0 FLOGO Accepts :0 FLOGO Rejects :0 CVL :0 FCF Discovery Timeouts :0 VN Port Session Timeouts :0 Session failures due to Hardware Config :0 show fip-snooping system D
show fip-snooping vlan Display information on the FCoE VLANs on which FIP snooping is enabled. S4820T Syntax show fip-snooping vlan Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the Z9500 and S6000-ON.
Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810.
19 Force10 Resilient Ring Protocol (FRRP) Force10 resilient ring protocol (FRRP) is supported on Dell Networking OS. FRRP is a proprietary protocol for that offers fast convergence in a Layer 2 network without having to run the spanning tree protocol (STP). The resilient ring protocol is an efficient protocol that transmits a highspeed token across a ring to verify the link status. All the intelligence is contained in the master node with practically no intelligence required of the transit mode.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.
To disable debugging, use the no debug frrp {event | packet | detail} {ring-id} [countnumber] command. Parameters event Enter the keyword event to display debug information related to ring protocol transitions. packet Enter the keyword packet to display brief debug information related to control packets. detail Enter the keyword detail to display detailed debug information related to the entire ring protocol packets. ring-id (Optional) Enter the ring identification number.
description Enter an identifying description of the ring. S4820T Syntax description Word To remove the ring description, use the no description [Word] command. Parameters Word Enter a description of the ring. Maximum: 255 characters. Defaults none Command Modes CONFIGURATION (conf-frrp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Defaults Disabled Command Modes CONFIGURATION (conf-frrp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
secondary interface control-vlan vlan-id Enter the keyword secondary to configure the secondary interface then one of the following interfaces and slot/port information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords portchannel then a number. Enter the keyword control-vlan then the VLAN ID.
member-vlan Specify the member VLAN identification numbers. S4820T Syntax member-vlan {vlan-range} To return to the default, use the no member-vlan [vlan-range] command. Parameters vlan-range Enter the member VLANs using VLAN IDs (separated by commas), a range of VLAN IDs (separated by a hyphen), a single VLAN ID, or a combination. For example: VLAN IDs (comma-separated): 3, 4, 6. Range (hyphen-separated): 5-10. Combination: 3, 4, 5-10, 8.
Parameters master Enter the keyword master to set the Ring node to Master mode. transit Enter the keywordtransit to set the Ring node to Transit mode. Defaults Mode None Command Modes CONFIGURATION (conf-frrp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series.
Usage Information Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series. 7.4.1.0 Introduced. Executing this command without the optional ring-id command clears the statistics counters on all the available rings. Dell Networking OS requires a command line confirmation before the command executes.
Example (2 Summary) Dell#show frrp 2 summary Related Commands protocol frrp — enters the resilient ring protocol and designate a ring identification. Dell#show frrp 2 summary Ring-ID State Mode Ctrl_Vlan Member_Vlans ----------------------------------------------2 Up Master 2 11-20, 25, 27-30 Dell# timer Set the hello interval or dead interval for the Ring control packets.
Usage Information 730 Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series. 7.4.1.0 Introduced. The hello interval command is the interval at which ring frames are generated from the primary interface of the master node. The dead interval command is the time that elapses before a time-out occurs.
GARP VLAN Registration (GVRP) 20 The Dell Networking operating system supports the basic GVRP commands on the Dell Networking OS. The generic attribute registration protocol (GARP) mechanism allows the configuration of a GARP participant to propagate through a network quickly. A GARP participant registers or de-registers its attributes with other participants by making or withdrawing declarations of attributes.
• VLANs created dynamically with GVRP exist only as long as a GVRP-enabled device is sending updates. If the devices no longer send updates, or GVRP is disabled, or the system is rebooted, all dynamic VLANs are removed. • GVRP manages the active topology, not non-topological data such as VLAN protocols. If a local bridge must classify and analyze packets by VLAN protocols, manually configure protocol-based VLANs, and simply rely on GVRP for VLAN updates.
Related Commands Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on C-Series, E-Series, and S-Series show gvrp statistics — displays the GVRP statistics. debug gvrp Enable debugging on GVRP. S4820T Syntax debug gvrp {config | events | pdu} To disable debugging, use the no debug gvrp {config | events | pdu} command. Parameters config Enter the keyword config to enable debugging on the GVRP configuration.
Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on C-Series, E-Series, and S-Series disable Globally disable GVRP. S4820T Syntax disable To re-enable GVRP, use the no disable command. Defaults Enabled. Command Modes CONFIGURATION-GVRP Command History This guide is platform-specific.
garp timers Set the intervals (in milliseconds) for sending GARP messages. S4820T Syntax garp timers {join | leave | leave-all} To return to the previous setting, use the no garp timers {join | leave | leave-all} command. Parameters join Enter the keyword join then the number of milliseconds to configure the join time. The range is from 100 to 147483647 milliseconds. The default is 200 milliseconds. NOTE: Designate the milliseconds in multiples of 100.
Usage Information Related Commands Version Description 7.6.1.0 Introduced on C-Series, E-Series, and S-Series • Join Timer — Join messages announce the willingness to register some attributes with other participants. For reliability, each GARP application entity sends a Join message twice and uses a join timer to set the sending interval. • Leave Timer — Leave announces the willingness to de-register with other participants.
Related Commands Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on C-Series, E-Series, and S-Series disable — globally disables GVRP. gvrp registration Configure the GVRP register type. S4820T Syntax gvrp registration {fixed | normal | forbidden} To return to the default, use the gvrp register normal command. Parameters fixed Enter the keyword fixed then the VLAN range in a commaseparated VLAN ID set.
Usage Information Fixed registration prevents an interface, configured using the command line, to belong to a VLAN (static configuration) from being unconfigured when it receives a Leave message. Therefore, Registration mode on that interface is fixed. Normal registration is the default registration. The port’s membership in the VLAN depends on GVRP. The interface becomes a member of a VLAN after learning about the VLAN through GVRP.
show config Display the global GVRP configuration. S4820T Syntax show config Command Modes CONFIGURATION-GVRP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Defaults none Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
show gvrp statistics Display the GVRP configuration statistics. S4820T Syntax Parameters show gvrp statistics {interface interface | summary} interface interface summary (OPTIONAL) Enter the keyword interface then one of the interface keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
A failed registration can occur for the following reasons: Example • Join requests were received on a port that was blocked from learning dynamic VLANs (GVRP Blocking state). • An entry for a new GVRP VLAN could not be created in the GVRP database.
High Availability (HA) 21 High availability (HA) in the Dell Networking operating software is configuration synchronization to minimize recovery time in the event of a route processor module (RPM) failure. The feature is available on Dell Networking OS. In general, a protocol is defined as “hitless” in the context of an RPM failure/failover and not failures of a line card, SFM, or power module. A protocol is defined as hitless if an RPM failover has no impact on the protocol.
Usage Information The patch filename includes the Dell Networking OS version, the platform, the CPU, and the process it affects (FTOS-platform-cpu-processpatchversion.rtp). For example, a patch labeled “7.8.1.0-EH-rp2-l2mgr-1.rtp” identifies that this patch applies to Dell Networking OS version 7.8.1.0 — E-Series platform, for RP2, addressing the layer 2 management process, and this patch is the first version of this patch. There is no need to reload or reboot the system when you insert the patch.
Related Commands Version Description 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced on the E-Series. show processes restartable redundancy auto-failover-limit Specify an auto-failover limit for RPMs. When a non-recoverable fatal error is detected, an automatic RPM failover occurs. This command does not affect user-initiated (manual) failovers.
Usage Information Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.5.1.0 Introduced on the C-Series. 7.6.1.0 Introduced on the E-Series If you disable auto failover, enter the redundancy auto-failover-limit (without any parameters) to set auto failover to the default parameters (Count 3, Period 60 minutes). To view the redundancy status, use the show redundancy command.
Usage Information Version Description 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in Programmable-Mux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Added the all option. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the E-Series Enabling this command keeps the failed RPM in the failed state.
Usage Information Version Description 8.3.12.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.5.1.0 Introduced on the C-Series. 7.6.1.0 Introduced on the E-Series. To provide a hitless or warm upgrade, use this command. A hitless upgrade means that a software upgrade does not require a reboot of the line cards. A warm upgrade means that a software upgrade requires a reset of the line cards.
Version Description 7.5.1.0 Introduced on the C-Series. 7.6.1.0 Introduced on the E-Series. redundancy protocol Enable hitless protocols. S4820T Syntax redundancy protocol {lacp | xstp} To disable a hitless protocol, use the no redundancy protocol {lacp | xstp} command. Parameters lacp Enter the keyword lacp to make LACP hitless. xstp Enter the keyword xstp to invoke hitless STP (all STP modes — MSTP, PVST+, RSTP, and STP).
redundancy reset-counter Reset failover counter and timestamp information displayed in the show redundancy command. S4820T Syntax redundancy reset-counter Default Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 7.5.1.0 Introduced on the C-Series. When you insert or remove a secondary RPM with logical SFM, the system must add or remove the backplane links to the switch fabric trunk. To avoid traffic disruption, use this command when you insert the secondary RPM. When you execute this command, the logical SFM on the standby RPM is immediately taken offline and the SFM state is set as “standby”.
redundancy synchronize Manually synchronize data once between the Master and Stand-by stack units. S4820T Syntax Parameters redundancy synchronize [full] full Enter the keyword full to synchronize all data. Default Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Related Commands Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.2.1.0 Introduced on the E-Series. patch flash://RUNTIME_PATCH_DIR — inserts an In-Service Modular Hot-Fix patch. show processes restartable Display the processes and tasks configured for restartability. S4820T Syntax Parameters show processes restartable [history] history Display the last time the restartable processes crashed.
Related Commands process restartable show redundancy Display the current redundancy configuration. S4820T Syntax show redundancy Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information High Availability (HA) Version Description 9.2(0.
Field Description PEER RPM Status Displays the state of the second RPM, if present RPM Redundancy Configuration Displays the following information: • which RPM is the preferred Primary on next boot (the redundancy primary command) • the data sync method configured (the redundancy synchronize command) • the failover type (you cannot change this type; it is software-dependent). Hot Failover means that the running configuration and routing table are applied on secondary RPM.
-----------------------------------------------Primary Stack-unit: mgmt-id 0 Auto Data Sync: Full Failover Type: Hot Failover Auto reboot Stack-unit: Disabled Auto failover limit: 3 times in 60 minutes -- Stack-unit Failover Record ------------------------------------------------Failover Count: 0 Last failover timestamp: None Last failover Reason: None Last failover type: None -- Last Data Block Sync Record: ------------------------------------------------Stack Unit Config: no block sync done Start-up Confi
Running Config: Dell# 758 succeeded Jul 13 2007 21:28:53 High Availability (HA)
22 ICMP Message Types This chapter lists and describes the possible ICMP message type resulting from a ping. The first three columns list the possible symbol or type/code. For example, you would receive a ! or 03 as an echo reply from your ping. ICMP Messages and Their Definitions. Symbol Type Code . Query Error Timeout (no reply) ! 0 U 3 C Description 4 5 ICMP Message Types 3 echo reply . destination unreachable: 0 network unreachable . 1 host unreachable .
Symbol & Type Code Description 0 redirect for network . 1 redirect for host . 2 redirect for type-of-service and network . 3 redirect for type-of-service and host . 8 0 echo request . 9 0 router advertisement . 10 0 router solicitation . 11 Error time exceeded: 0 time-to-live equals 0 during transit . 1 time-to-live equals 0 during reassembly . 12 760 Query parameter problem: 1 IP header bad (catchall error) . 2 required option missing .
Internet Group Management Protocol (IGMP) 23 The IGMP commands are supported by the Dell Networking operating software on the Dell Networking OS. This chapter contains the following sections: • IGMP Commands • IGMP Snooping Commands IGMP Commands Dell Networking OS supports IGMPv1/v2/v3 and is compliant with RFC-3376.
NOTE: Applies to specific VRF if input is provided, else applies to default VRF. group-address (OPTIONAL) Enter the IP multicast group address in dotted decimal format. interface interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
Parameters • To disable IGMP debugging, use the no debug ip igmp [vrf vrf-name] [group address | interface] command. • To disable all debugging, use the undebug all command. vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to enable debugging of IGMP packets corresponding to that VRF. NOTE: Applies to specific VRF if input is provided, else applies to Default VRF. group-address (OPTIONAL) Enter the IP multicast group address in dotted decimal format.
Usage Information IGMP commands accept only non-VLAN interfaces — specifying VLAN does not yield results. This command displays packets for IGMP and IGMP snooping. ip igmp access-group To specify access control for packets, use this feature. S4820T Syntax ip igmp access-group access-list To remove the feature, use the no ip igmp access-group access-list command. Parameters access-list Enter the name of the extended ACL (16 characters maximum).
ip igmp group-join-limit To limit the number of IGMP groups that can be joined in a second, use this feature. Z9500 Syntax Parameters ip igmp group-join-limit number number Enter the number of IGMP groups permitted to join in a second. The range is from 1 to 10000. Defaults none Command Modes CONFIGURATION (conf-if-interface-slot/port) Command History This guide is platform-specific.
Parameters group-list prefix-listname Enter the keywords group-list then a string up to 16 characters long of the prefix-list-name. Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Parameters milliseconds Enter the number of milliseconds as the interval. For IGMP version 2, the range is from 100 to 25599. For IGMP version 3, the range is from 100 to 65535. The default value is 1000 milliseconds. Defaults 1000 milliseconds Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Maximum range of the Hello interval value is changed to 18000. Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator.
Parameters seconds Enter the number of seconds for the maximum response time. The range is from 1 to 25. The default is 10 seconds. Defaults 10 seconds Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.
Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure this setting on that VRF. NOTE: Applies to specific VRF if input is provided, else applies to Default VRF. std-access-list Specify the standard IP access list that contains the mapping rules for multicast groups. source-address Specify the multicast source address to which the groups are mapped. Command Modes CONFIGURATION Command History This guide is platform-specific.
Parameters 2 Enter the number 2 to set the IGMP version number to IGMPv2. 3 Enter the number 3 to set the IGMP version number to IGMPv3. Defaults 2 (that is, IGMPv2) Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
interface detail (OPTIONAL) Enter the interface type and slot/port information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords portchannel then a number.
Example Example (VLT) Field Description Group Address Lists the multicast address for the IGMP group. Interface Lists the interface type, slot and port number. Mode Displays the IGMP version used. Uptime Displays the amount of time the group has been operational. Expires Displays the amount of time until the entry expires. Last Reporter Displays the IP address of the last host to be a member of the IGMP group.
65.0.0.2 65.0.0.3 65.0.0.4 65.0.0.5 00:01:22 00:01:22 00:01:22 00:01:22 show ip igmp interface View information on the interfaces participating in IGMP. S4820T Syntax Parameters show ip igmp [vrf vrf-name] interface [interface] vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to view IGMP interfaces associated with that VRF.
Version Description 7.5.1.0 Introduced on the C-Series. E-Series legacy command. Usage Information IGMP commands accept only non-VLAN interfaces — specifying VLAN does not yield results. The show ip igmp interface command does not display information corresponding to the loop-back interfaces.
IGMP version is 3 Dell# show ip igmp ssm-map Display is a list of groups that are currently in the IGMP group table and contain SSM mapped sources. S4820T Syntax Parameters show ip igmp [vrf vrf-name] ssm-map [group] vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure this setting on that VRF. NOTE: Applies to specific VRF if input is provided, else applies to Default VRF.
65.0.0.2 65.0.0.3 65.0.0.4 65.0.0.5 Related Commands 00:01:22 00:01:22 00:01:22 00:01:22 ip igmp ssm-map — uses a statically configured list to translate (*,G) memberships to (S,G) memberships. IGMP Snooping Commands Dell Networking OS supports IGMP Snooping version 2 and 3 on all Dell Networking systems. Important Points to Remember for IGMP Snooping • Dell Networking OS supports version 1, version 2, and version 3 hosts.
clear ip igmp snooping groups Clear snooping entries from the group cache table. S4820T Syntax Parameters clear ip igmp snooping groups [group-address interface | interface] group-address (OPTIONAL) Enter the IP multicast group address in dotted decimal format. interface interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Parameters snooping Enter the keyword snooping to enable debugging of IGMP snooping. group-address (OPTIONAL) Enter the IP multicast group address in dotted decimal format. interface interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in Programmable-Mux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. To enable IGMP snooping, enter this command.
Version Description 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in Programmable-Mux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command.
Version Description 8.2.1.0 Introduced on the C-Seris and S-Series. 7.7.1.0 Introduced on the E-Series. E-Series legacy command Usage Information On the C-Series and S-Series, unregistered multicast data traffic drops when you disable flooding; they do not forward the packets to multicast router ports. On the C-Series and S-Series, in order to disable Layer 2 multicast flooding, disable Layer 3 multicast (no ip multicast-routing).
Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information This last-member-query-interval is also the interval between successive GroupSpecific Query messages. To change the last-member-query interval, use this command. ip igmp snooping mrouter Statically configure a VLAN member port as a multicast router interface.
Version Description 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in Programmable-Mux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information This command enables the IGMP switch to send General Queries periodically. This behavior is useful when there is no multicast router present in the VLAN because the multicast traffic is not routed.
Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, Z9000, and Z9500.
show ip igmp snooping mrouter Display multicast router interfaces. S4820T Syntax Parameters show ip igmp snooping mrouter [vlan number] vlan number Enter the keyword vlan then the vlan number. The range is from 1 to 4094. Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
• 788 show ip igmp groups — view groups.
24 Interfaces The commands in this chapter are supported by Dell Networking operating software on the S8420T platform. This chapter contains the following sections: • Basic Interface Commands • Port Channel Commands • Time Domain Reflectometer (TDR) • UDP Broadcast Basic Interface Commands The following commands are for Physical, Loopback, and Null interfaces.
• For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a tunnel interface, enter the keyword tunnel. The range is from 1 to 16383. vrrp [[ipv6] vrid] (OPTIONAL) Enter the keyword vrrp to clear the counters of all VRRP groups. To clear the counters of VRRP groups on all IPv6 interfaces, enter ipv6. To clear the counters of a specified group, enter a VRID number from 1 to 255.
Example Dell#clear counters Clear counters on all interfaces [confirm] Related Commands mac learning-limit — allows aging of MACs even though a learning-limit is configured or disallow station move on learned MACs. show interfaces — displays information on the interfaces. clear dampening Clear the dampening counters on all the interfaces or just the specified interface.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. Usage Information After you enter the clear counters command and verify the results with the show interfaces command, the line rate is not reset to 0.00%. Example Dell#clear dampening tegigabitethernet 1/10 Clear dampening counters on TeGi 1/10 [confirm] y Dell# Related Commands show interfaces dampening — displays interface dampening information.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series.
Parameters desc_text Enter a text string up to 240 characters long. Defaults none Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Parameters half Enter the keyword half to set the physical interface to transmit only in one direction. full Enter the keyword full to set the physical interface to transmit in both directions. Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Parameters rx on Enter the keywords rx on to process the received flow control frames on this port. This is the default value for the receive side. rx off Enter the keywords rx off to ignore the received flow control frames on this port. tx on Enter the keywords tx on to send control frames from this port to the connected device when a higher rate of traffic is received.
the pause operation instruct the MAC to enable the reception of frames with a destination address equal to this multicast address. When a port receives traffic at a higher rate than it can process, the frames are stored in the port buffer. As a result, buffer usage increases. When the buffer usage reaches the value specified in the “pause-threshold” argument, the port sends PAUSE frame to the connected link partner to stop sending the traffic. Eventually this reduces the buffer usage.
Related Commands off off off off on on off on off on off on off off on on off on off on on off off off on on off on off on on on off off on on off on off on LocNegRx off off off off LocNegTx RemNegRx RemNegTx off off off off off off off off off off off off off off off off off off on off off off on off off off off off off on on on off off on on off off on on off on on on off off on on off off on on off off on on off off on on show running-config — displays the flow configuratio
• • • • • • • range For a null interface, enter the keyword null then the slot/port information. The Null interface number is 0. For the Management interface on the stack-unit, enter the keyword ManagementEthernet then the slot/port information. The slot range is from 0 to1. The port range is 0. For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
interface’s configuration does not contain an IP address and enter the switchport command. You can create up to 64 tunnel interfaces. The tunnel is added as a logical interface with no default configuration. To delete a tunnel interface, use the no interface tunnel tunnel-id command. The tunnel interface operates as an ECMP (equal cost multi path) only when the next hop to the tunnel destination is over a physical interface.
(comma-separated): 3, 4, 6. Range (hyphen-separated): 5-10. Slot/Port information need not contain a space before and after the dash. For example. both of the following commands are valid: interface group tengigabitethernet 1/1 - 5 ; interface group tengigabitethernet 1/1-5; ; . Command Modes Command History Usage Information • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
interface loopback Configure a Loopback interface. S4820T Syntax interface loopback number To remove a loopback interface, use the no interface loopback number command. Parameters number Enter a number as the interface number. The range is from 0 to 16383. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
interface ManagementEthernet Configure the Management port on the system (either the Primary or Standby RPM). S4820T Syntax Parameters interface ManagementEthernet slot/port slot/port Enter the keyword ManagementEthernet, then the slot number (0 or 1) and port number zero (0). Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
speed (Management interface) — clears the FIB entries on a specified line card. interface null Configure a Null interface on the switch. S4820T Syntax Parameters interface null number number Enter zero (0) as the Null interface number. Defaults Not configured; number = 0 Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
ip unreachables — enables generation of internet control message protocol (ICMP) unreachable messages. interface range This command permits configuration of a range of interfaces to which subsequent commands are applied (bulk configuration). Using the interface range command, you can enter identical commands for a range of interface. S4820T Syntax Parameters interface range interface {slot/port | port} — port}, interface {slot/port | port} — port},...
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.2.1.0 Added support for 4093 VLANs on E-Series ExaScale. Prior releases supported 2094. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. When creating an interface range, interfaces appear in the order they are entered; they are not sorted.
the interface range command. You cannot create virtual interfaces (VLAN, Port-channel) using the interface range command. NOTE: If a range has VLAN, physical and port-channel interfaces, only commands related to physical interfaces can be bulk configured. To configure commands specific to VLAN and port-channel only those respective interfaces should be configured in a particular range. Example (Single Range) This example shows a single range bulk configuration.
Parameters name Enter up to 16 characters for the macro name. interface, interface,... Enter the keywords interface range and one of the interfaces — slot/port, port-channel, or VLAN number. Select the range of interfaces for bulk configuration. You can enter up to six comma-separated ranges. Spaces are not required between the commas. Comma-separated ranges can include VLANs, port-channels, and physical interfaces. • For a port channel interface, enter the keywords portchannel then a number.
Example (Single Range) This example shows how to define an interface range macro named test. Execute the show running-config command to display the macro definition.
Example (Single Range) Version Description 6.2.1.0 Introduced This example shows the macro named test that was defined earlier. Dell(config)#interface range macro test Dell(config-if-range-te-1/1-3,te-5/1-47,te-13/1-89)# Dell Related Commands interface range — configures a range of command (bulk configuration). interface range macro (define) — defines a macro for an interface range (bulk configuration). interface vlan Configure a VLAN. You can configure up to 4094 VLANs.
Usage Information For more information about VLANs and the commands to configure them, refer to the Virtual LAN (VLAN) Commands section of the Layer 2 chapter. FTP, TFTP, and SNMP operations are not supported on a VLAN. MAC ACLs are not supported in VLANs. IP ACLs are supported. For more information, refer to the Access Control Lists (ACL) chapter.
Command Modes Command History Usage Information INTERFACE Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module. If you configure the interface type as CR4 with auto-negotiation enabled, also configure CR4 with auto-negotiation.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.0 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.0 Introduced on the E-Series. This command is supported on C-Series, S-Series, and E-Series (TeraScale and ExaScale) 10/100/1000 Base-T Ethernet interfaces.
Dell(conf-if-autoneg)#mode ? forced-master Force port to master mode forced-slave Force port to slave mode Dell(conf-if-autoneg)# Example (Configured) Dell#show interfaces configured TenGigabitEthernet 13/18 is up, line protocol is up Hardware is Force10Eth, address is 00:01:e8:05:f7:fc Current address is 00:01:e8:05:f7:fc Interface index is 474791997 Internet address is 1.1.1.
keepalive Send keepalive packets periodically to keep an interface alive when it is not transmitting data. S4820T Syntax keepalive To stop sending keepalive packets, use the no keepalive command. Defaults Enabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Parameters interface (OPTIONAL) Enter the following keywords and slot/port or number information: • For the Management interface on the stack-unit, enter the keyword ManagementEthernet then the slot/port information. The slot range is from 0 to1. The port range is 0. • For a Tunnel interface, enter the keyword tunnel then the slot/port. The range is from 1 to 16383. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Example (Single Interface) Key Description monitor time Displays the amount of time since the monitor interface command was entered. time Displays the amount of time the chassis is up (since last reboot). m Change the view from a single interface to all interfaces on the line card or visa-versa. c Refresh the view. b Change the counters displayed from Packets on the interface to Bytes.
Example (All Interfaces) systest-3 Monitor time: 00:01:31 Refresh Intvl.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.5.1.0 Introduced on the C-Series. pre-Version 6.2.1.0 Introduced on the E-Series.
Layer 2 Overhead Link MTU and IP MTU Delta Untagged Packet with VLAN-Stack Header 22 bytes Tagged Packet with VLAN-Stack Header 26 bytes portmode hybrid To accept both tagged and untagged frames, set a physical port or port-channel. A port configured this way is identified as a hybrid port in report displays. S4820T Syntax portmode hybrid To return a port to accept either tagged or untagged frames (non-hybrid), use the no portmode hybrid command.
• untagged frames and classify them as VLAN 10 frames • VLAN 20 tagged frames The following describes the do show interfaces command shown in the following example. This example shows output with “Hybrid” as the newly added value for 802.1QTagged. The options for this field are: • True — port is tagged • False — port is untagged • Hybrid — port accepts both tagged and untagged frames The following describes the interface vlan command shown in the following example.
NOTE: Because polling occurs every 15 seconds, the number of seconds designated here rounds to the multiple of 15 seconds lower than the entered value. For example, if 44 seconds is designated, it rounds to 30; 45 to 59 seconds rounds to 45. Defaults 299 seconds Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-Version 6.2.1.0 Introduced on the E-Series.
Example Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series.
Command Modes Command History Usage Information • EXEC • EXEC Privilege Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.2(0.2) Added support for the tunnel interface type. 9.1(0.0) Updated Management Ethernet output to include two global IPv6 addresses on S4810 and Z9000 and added output example showing OpenFlow instance ID. 8.3.12.1 Updated command output to support multiple IPv6 addresses on S4810. 8.3.11.
Line Description TenGigabitEthern et 1/1... Interface type, slot/port, and administrative and line protocol status. Hardware is... Interface hardware information, assigned MAC address, and current address. Pluggable media present... Present pluggable media wavelength, type, and rate.
Line Description – Broadcasts = number of MAC broadcast packets • Number of runts, giants, and throttles packets: – runts = number of packets that are less than 64B – giants = packets that are greater than the MTU size – throttles = packets containing PAUSE frames • Number of CRC, overrun, and discarded packets: – CRC = packets with CRC/FCS errors – overrun = number of packets discarded due to FIFO overrun conditions – discarded = the sum of runts, giants, CRC, and overrun packets discarded without any
MTU 1554 bytes, IP MTU 1500 bytes LineSpeed auto Flowcontrol rx on tx off ARP type: ARPA, ARP Timeout 04:00:00 Last clearing of "show interface" counters 3d17h53m Queueing strategy: fifo Input Statistics: 0 packets, 0 bytes 0 64-byte pkts, 0 over 64-byte pkts, 0 over 127-byte pkts 0 over 255-byte pkts, 0 over 511-byte pkts, 0 over 1023-byte pkts 0 Multicasts, 0 Broadcasts 0 runts, 0 giants, 0 throttles 0 CRC, 0 overrun, 0 discarded Output Statistics: 0 packets, 0 bytes, 0 underruns 0 64-byte pkts, 0 over 64
0 Vlans, 0 throttles, 0 discarded, 0 collisions, 0 wreddrops Rate info (interval 299 seconds): Input 00.00 Mbits/sec, 0 packets/sec, 0.00% of line-rate Output 00.00 Mbits/sec, 0 packets/sec,0.
ARP type: ARPA, ARP Timeout 04:00:00 Last clearing of "show interface" counters 00:06:14 Queueing strategy: fifo Input 791 packets, 62913 bytes, 775 multicast Received 0 errors, 0 discarded Output 21 packets, 3300 bytes, 20 multicast Output 0 errors, 0 invalid protocol Time since last interface status change: 00:06:03 Example (OpenFlow instance) Dell#show interfaces vlan 6 Vlan 6 is down, line protocol is down Address is 00:01:e8:8a:e1:8c, Current address is 00:01:e8:8a:e1:8c Interface index is 1107525638
show interfaces configured Display any interface with a non-default configuration. S4820T Syntax show interfaces configured Command Modes • EXEC • EXEC Privilege Command History Example Interfaces Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.
Rate info (interval 299 seconds): Input 00.00 Mbits/sec, 0 packets/sec, 0.00% of line-rate Output 00.00 Mbits/sec, 0 packets/sec, 0.00% of line-rate Time since last interface status change: 00:04:59 Dell# Related Commands show interfaces — displays information on a specific physical interface or virtual interface. show interfaces dampening Display interface dampening information.
Version Description 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Introduced Example Dell#show interfaces dampening Interface Supp Flaps Penalty Half-Life Reuse Suppress Max-Sup State Te 3/2 Up 0 0 20 800 4500 120 Te 3/10 Up 0 0 5 750 2500 20 Dell# Related Commands dampening — configures dampening on an interface.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the C-Series and S-Series. 6.5.4.0 Introduced on the E-Series. The following describes the show interfaces gigabitethernet command following example. Mode Control Indicates if auto negotiation is enabled. If so, indicates the selected speed and duplex. Mode Status Displays auto negotiation fault information.
• 0 - < 50 meters • 1 - 50 - 80 meters • 2 - 80 - 110 meters • 3 - 110 - 140 meters • 4 - 140 meters Link Status: Up or Down Speed: • Auto • 1000MB • 100MB • 10MB Example Dell#show interfaces tengigabitethernet 1/0 phy Mode Control: SpeedSelection: 10b AutoNeg: ON Loopback: False PowerDown: False Isolate: False DuplexMode: Full Mode Status: AutoNegComplete: False RemoteFault: False LinkStatus: False JabberDetect: False AutoNegotation Advertise: 100MegFullDplx: True 100MegHalfDplx: True 10
show interfaces stack-unit Display information on all interfaces on a specific S-Series or Z-Series stack member. S4820T Syntax Parameters Command Modes Command History show interfaces stack-unit unit-number unit-number • • Enter the stack member number. The range is from 0 to 11 for the S4820T. EXEC EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
0 over 255-byte pkts, 0 over 511-byte pkts, 0 over 1023-byte pkts 0 Multicasts, 0 Broadcasts, 0 Unicasts 0 throttles, 0 discarded, 0 collisions Rate info (interval 299 seconds): Input 00.00 Mbits/sec, 0 packets/sec, 0.00% of line-rate Output 00.00 Mbits/sec, 0 packets/sec, 0.
Example Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.5.1.0 Introduced on the E-Series.
stack-unit unitid • For a port channel interface, enter the keywords portchannel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a backup interface for this interface, enter the keyword backup. (OPTIONAL) Enter the keywords stack-unit then the stack member number.
Example Items Description 802.1QTagged Displays whether if the VLAN tagged (“True”), untagged (“False”), or hybrid (“Hybrid”), which supports both untagged and tagged VLANs by port 13/0. Vlan membership Lists the VLANs to which the interface is a member. Starting with Dell Networking OS version 7.6.1, this field can display native VLAN membership by port 13/0. Dell#show interfaces switchport Name: TenGigabitEthernet 13/1 802.
Parameters tengigabitether net For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. fortyGigE For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Line Description Bias High Alarm threshold Factory-defined setting. Value can differ between SFP and SFP+. TX Power High Alarm threshold Factory-defined setting. Value can differ between SFP and SFP+. RX Power High Alarm threshold Factory-defined setting. Value can differ between SFP and SFP+. Temp Low Alarm threshold Factory-defined setting. Value can differ between SFP and SFP+. Voltage Low Alarm threshold Factory-defined setting. Value can differ between SFP and SFP+.
Interfaces Line Description Voltage Current voltage of the SFPs. If this voltage crosses voltage high alarm/warning thresholds, the voltage high alarm/ warning flag is set to true. Tx Bias Current Present transmission (Tx) bias current of the SFP. If this crosses bias high alarm/warning thresholds, the TX bias high alarm/warning flag is set to true. If it falls below the low alarm/warning thresholds, the TX bias low alarm/warning flag is set to true. Tx Power Present Tx power of the SFP.
Example Line Description Temperature Low Alarm Flag This can be either true or false, depending on the Current Temperature value displayed above. Voltage Low Alarm Flag This can be either true or false, depending on the Current voltage value displayed above. Tx Bias Low Alarm Flag This can be either true or false, depending on the Tx bias current value displayed above. Tx Power Low Alarm Flag This can be either true or false, depending on the Current Tx power value displayed above.
SFP SFP SFP SFP SFP SFP SFP SFP SFP SFP SFP SFP SFP 0 0 0 0 0 0 0 0 0 0 0 0 0 Length(50um) 10m = 0x1e Length(62.
=================================== !-------output truncated ------------------------Related Commands interface — configures a physical interface on the switch. show ip interface — displays Layer 3 information about the interfaces. show interfaces — displays information on a specific physical interface or virtual interface.
Output Statistics: 0 packets, 0 bytes, 0 underruns Related Commands show interfaces — displays information on a specific physical interface or virtual interface. show range Display all interfaces configured using the interface range command. S4820T Syntax show range Command Modes INTERFACE RANGE (config-if-range) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
show running-config ecmp-group Display interfaces, LAG, or LAG link bundles being monitored for uneven traffic distribution using the ecmp-group monitoring enable command. The ECMP group could have a LAG or a list of 10G/40 interfaces (not just LAG link-bundles). S4820T Syntax show running-config ecmp-group Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information The shutdown command marks a physical interface as unavailable for traffic.
Parameters 10 Enter the keyword 10 to set the interface’s speed to 10 Mb/s. NOTE: This interface speed is not supported on the LCEH-GE-50P or the LC-EJ-GE-50P card. If the command is entered for these interfaces, an error message appears. 100 Enter the keyword 100 to set the interface’s speed to 10/100 Mb/s. NOTE: When this setting is enabled, only 100Base-FX optics are supported on the LC-EH-GE-50P or the LCEJ-GE-50P card. 1000 Enter the keyword 1000 to set the interface’s speed to 1000 Mb/s.
Usage Information This command is found on the 10/100/1000 Base-T Ethernet interfaces. When you enable auto, the system performs an automatic discovery to determine the optics installed and configure the appropriate speed. When you configure a speed for the 10/100/1000 interface, confirm the negotiation auto command setting. Both sides of the link must have autonegotiation either enabled or disabled.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.11.1 Introduced on the S55, S60, and S4810 8.1.1.0 Introduced on the E-Series ExaScale. 7.5.1.0 Introduced on the C-Series. pre-Version 6.2.1.0 Introduced on the E-Series. Usage Information This command is found on the Management interface only.
Usage Information Version Description 9.7(0.0) Added support for dynamically fanning-out of interfaces on S6000. Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.1 Introduced on the S4810. Splitting a 40G port into 4x10G port is supported on standalone and stacked units. stack-unit stack-unit port number portmode quad dynamically fan-out 40G ports to 10G ports and vice-versa without reload in switch.
backup port changes to the up state. If the primary later comes up, it becomes the backup. tengigabit Enter the keyword tengigabit if the backup port is a 10G port. fortyGigE Enter the keyword fortyGigE if the backup port is a 40G port. port-channel Enter the keywords port-channel if the backup port is a static or dynamic port channel. slot/port Specify the line card and port number of the backup port. Defaults Disabled (The interface is in Layer 3 mode.
To use the switchport backup interface command on a port, first enter the switchport command. For more information, refer to the “Configuring Redundant Links” section in the “Layer 2” chapter of the Dell Networking OS Configuration Guide. Egress Interface Selection (EIS) Commands The following commands are Egress Interface Selection (EIS) commands. application Configure the management egress interface selection.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.2.(0.0) Introduced on the Z9000, S4810, and S4820T. application (for HTTP and ICMP) Configure the management egress interface selection for HTTP and ICMP. NOTE: Only the options that have been newly introduced are described here.
clear management application pkt-cntr Clear management application packet counters for all management application types. S4820T Syntax clear management application pkt-cntr Defaults None. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.2.(0.
management egress-interface-selection To make configured application traffic egress through the management port instead of the front-end (FE) port, enable and configure a management egress interface. S4820T Syntax management egress-interface-selection To disable and remove management egress interface selection (EIS) configurations, use the no management egress-interface-selection command. Defaults None. Command Modes CONFIGURATION Command History This guide is platform-specific.
10.11.0.0/16 172.16.1.0/24 ManagementEthernet 0/0 10.11.192.4 Connected Active Connected Static show management application pkt-cntr Display the number of packets for each application type that have taken the management route. S4820T Syntax show management application pkt-cntr Defaults None. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.2.(0.0) Introduced on the Z9000, S4810, and S4820T.
To delete an interface from a Port Channel, use the no channel-member interface command. Parameters interface (OPTIONAL) Enter any of the following keywords and slot/ port or number information: • For a 100/1000 Ethernet interface, enter the keyword GigabitEthernet then the slot/port information. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
• All members must have the same link MTU value and the same IP MTU value. • The Port Channel link MTU and IP MTU must be less than or equal to the link MTU and IP MTU values configured on the channel members. For example, if the members have a link MTU of 2100 and an IP MTU 2000, the Port Channel’s MTU values cannot be higher than 2100 for link MTU or 2000 bytes for IP MTU.
port-channel number Enter the keywords port-channel then an existing LAG number. Enter this keyword/variable combination twice, identifying the two paired LAGs. Defaults none Command Modes PORT-CHANNEL FAILOVER-GROUP (conf-po-failover-grp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. Version 9.0.2.0 Introduced on the S6000. Version 8.3.19.0 Introduced on the S4820T. Version 8.3.12.0 Introduced on S4810. Version 8.3.11.
Related Commands channel-member — adds a physical interface to the LAG. interface — configures a physical interface. interface loopback — configures a Loopback interface. interface null — configures a null interface. interface vlan — configures a VLAN. shutdown — disables/enables the port channel. minimum-links Configure the minimum number of links in a LAG (Port Channel) that must be in “oper up” status for the LAG to be also in “oper up” status.
Usage Information If you use this command to configure the minimum number of links in a LAG that must be in “oper up” status, the LAG must have at least that number of “oper up” links before it can be declared as up. For example, if the required minimum is four, and only three are up, the LAG is considered down. port-channel failover-group To configure a LAG failover group, access PORT-CHANNEL FAILOVER-GROUP mode.
show interfaces port-channel — displays information on configured Port Channel groups. show config Display the current configuration of the selected LAG. S4820T Syntax show config Command Modes INTERFACE PORTCHANNEL Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 8.3.
brief (OPTIONAL) Enter the keyword brief to display only the port channel number, the state of the port channel, and the number of interfaces in the port channel. Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Example Interfaces Field Description Members in this... Displays the interfaces belonging to this port channel. ARP type:... Displays the ARP type and the ARP timeout value for the interface. Last clearing... Displays the time when the show interfaces counters were cleared. Queueing strategy. States the packet queuing strategy. FIFO means first in first out. packets input... Displays the number of packets and bytes into the interface. Input 0 IP packets...
Output 5428 Multicasts, 4 Broadcasts, 1212688 Unicasts 1216142 IP Packets, 0 Vlans, 0 MPLS 0 throttles, 0 discarded Rate info (interval 299 sec): Input 01.50Mbits/sec, 2433 packets/sec Output 00.02Mbits/sec,4 packets/sec Time since last interface status change: 00:22:34 Dell# User Information The following describes the show interfaces port-channel brief command shown in the following example. Field Description LAG Lists the port channel number.
show port-channel-flow Display an egress port in a given port-channel flow. S4820T Syntax Parameters Command Modes Interfaces show port-channel-flow outgoing-port-channel number incominginterface interface {source-ip address destination-ip address} | {source-port number destination-port number} | {source-mac address destination-mac address {vlan vlanid | ether-type}} outgoing-portchannel number Enter the keywords outgoing-port-channel then the number of the port channel to display flow information.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.10.0 Introduced on the S4810.
Time Domain Reflectometer (TDR) TDR is useful for troubleshooting an interface that is not establishing a link; either it is flapping or not coming up at all. TDR detects open or short conditions of copper cables on 100/1000 Base-T modules. Important Points to Remember • The interface and port must be enabled (configured—refer to the interface command) before running TDR. An error message is generated if you have not enabled the interface.
Usage Information The interface must be enabled to run the test or an error message is generated: Dell#tdr-cable-test tengigabitethernet 11/1 % Error: Interface is disabled Te 11/1. Syslog messages are generated when the link flaps during TDR tests. Related Commands show tdr — displays the results of the TDR test. show tdr Display the TDR test results.
Status Definition OK Status: Terminated TDR test is complete, no fault is detected on the cable, and the test is terminated. Length: 92 (+/- 1) meters, Status: Shorted A short is detected on the cable. The location, in this Example is 92 meters. The short is accurate to plus or minus one meter. Length: 93 (+/- 1) meters, Status: Open An opening is detected on the cable. The location, in this Example is 93 meters. The open is accurate to plus or minus one meter.
debug ip udp-helper Enable UDP debug and display the debug information on a console. S4820T Syntax debug ip udp-helper To disable debug information, use the no debug ip udp-helper command. Defaults Debug disabled. Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
ip udp-broadcast-address Configure an IP UDP address for broadcast. Syntax ip udp-broadcast-address address To delete the configuration, use the no ip udp-broadcast-address address command. Parameters address Enter an IP broadcast address in dotted decimal format (A.B.C.D). Defaults Not configured. Command Modes INTERFACE (config-if) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Parameters udp-port-list (OPTIONAL) Enter up to 16 comma-separated UDP port numbers. NOTE: If you do not use this option, all UDP ports are considered by default. Defaults none Command Modes INTERFACE (config-if) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
show ip udp-helper Display the configured UDP helpers on all interfaces. S4820T Syntax show ip udp-helper Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
such as interface range fo 2/0-1,te 10/0,gi 3/0,fa 0/0, this configuration is considered valid. The comma-separated list is not required to be separated by spaces in between the ranges. You can associate multicast MAC or hardware addresses to an interface range and VLANs by using the macaddress-table static multicast-mac-address vlan vlan-id output-range interface command. ip http source-interface Specify an interface as the source interface for HTTP connections.
Related Commands Interfaces Version Description 7.5.1.0 Introduced on C-Series ip ftp source interface Configuring source interface for ftp communications.
Internet Protocol Security (IPSec) 25 Internet protocol security (IPSec) is an end-to-end security scheme for securing IP communications by authenticating and encrypting all packets in a session. Use IPSec between hosts, gateways, or hosts and gateways. IPSec uses a series of protocol functions to achieve information security: • • • Authentication Headers (AH) — Connectionless integrity and origin authentication for IP packets.
To delete a transform set, use the no crypto ipsec transform-set name {ah-authentication {md5|sha1|null} | esp-authentication {md5| sha1|null} | esp-encryption {3des|cbc|des|null}} command. Parameters name Enter the name for the transform set. ahauthentication Enter the keywords ah-authentication then the transform type of operation to apply to traffic. The transform type represents the encryption or authentication applied to traffic.
Version Description 9.2(0.2) Introduced on the Z9000, S4810, and S4820T. Usage Information • Both sides of the link must specify the same transform set. • You can create up to 64 transform sets. Example Dell(conf)#do show crypto ipsec transform-set Transform-Set Name Transform-Set refCnt AH Transform ESP Auth Transform ESP Encry Transform : ts1 : 0 : md5 : : Dell(conf)# crypto ipsec policy Create a crypto policy used by ipsec.
Usage Information This command creates a crypto policy entry and enters the crypto policy configuration mode for configuring the flow parameters. Example Dell(conf)#crypto ipsec policy West 10 ipsec-manual Dell(conf-crypto-policy)# management crypto-policy Apply the crypto policy to management traffic. S4820T Syntax management crypto-policy name To remove the management traffic crypto policy, use the no management crypto-policy name command. Parameters name Enter the name for the crypto policy..
[destination ip address | ipv6 address {mask} {destination-port number}] command. Parameters seq-num Enter the match command sequence number. sourceipaddress | ipv6 address Enter the keyword source then the IPv4 or IPv6 address for the source. mask Enter the mask prefix length in /nn format. source-port number Enter the source port number. destinationport number Enter the destination port number.
session-key Specify the session keys used in the crypto policy entry. S4820T Syntax session-key {inbound | outbound} {ah spi hex-key-string | esp spi encrypt hex-key-string auth hex-key-string To delete the session key information from the crypto policy, use the no session-key {inbound | outbound} {ah | esp} command. Parameters name Enter the name for the transform set. inbound Specify the inbound session key for IPSec. outbound Specify the outbound session key for IPSec.
show crypto ipsec transform-set Display the transform set configuration. S4820T Syntax Parameters show crypto ipsec transform-set name name Enter the name of the transform set. Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.2(0.
Version 9.2(0.2) Example Introduced on the Z9000, S4810, and S4820T.
Defaults none Command Modes CONFIG-CRYPTO-POLICY Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. 890 Version Description 9.2(0.2) Introduced on the Z9000, S4810, and S4820T.
26 IPv4 Routing The basic IPv4 commands are supported by Dell Networking operating system on the S4820T platform. arp To associate an IP address with a MAC address in the switch, use address resolution protocol (ARP). S4820T Syntax arp [vrf vrf-name] ip-address mac-address interface To remove an ARP address, use the no arp ip-address command. Parameters vrf vrf-name Enter a VRF name to configure an ARP entry for that VRF.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.
Parameters seconds Enter the number of seconds an ARP entry is black-holed. The range is from 1 to 3600. The default is 30. Defaults 30 Command Mode CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced. In Dell Networking OS versions prior to 8.3.1.0, if a gratuitous ARP is received some time after an ARP request is sent, only RP2 installs the ARP information. For example: 1. At time t=0, Dell Networking OS sends an ARP request for IP A.B.C.D. 2.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Introduced on the S4810 and S4820T. Use this command to specify the maximum number of ARP entries that the Route Table Manager can hold for a specific VRF. This command does not apply to the management VRFs. arp retries Set the number of ARP retries in case the system does not receive an ARP reply in response to an ARP request. S4820T Syntax Parameters arp retries number number Enter the number of retries.
arp timeout Set the time interval for an ARP entry to remain in the ARP cache. S4820T Syntax Parameters arp timeout minutes minutes Enter the number of minutes. The range is from 0 to 35790. The default is 240 minutes. Defaults 240 minutes (4 hours) Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
clear arp-cache Clear the dynamic ARP entries from a specific interface or optionally delete (no-refresh) ARP entries from the content addressable memory (CAM). S4820T Syntax Parameters clear arp-cache [vrf vrf-name | interface | ip ip-address] [norefresh] vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the name of the VRF to clear the ARP cache corresponding to that VRF.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Added support for 4094 VLANs on the E-Series ExaScale (the prior limit was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.9.1.0 Introduced VRF on the E-Series. 7.6.1.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. clear ip fib stack-unit Clear all FIB entries in the specified stack unit (use this command with caution, refer to Usage Information.) Syntax Parameters clear ip fib stack-unit unit-number vrf vrf-name unit-number Enter the number of the stack unit.
Related Commands show ip fib stack-unit — shows FIB entries on a specified stack-unit. clear ip route Clear one or all routes in the routing table. S4820T Syntax Parameters clear ip route [vrf vrf-name] {* | ip-address mask} vrf vrf-name (Optional) Enter the keyword vrf and then the name of the VRF to clear the routes corresponding to that VRF. * Enter an asterisk (*) to clear all learned IP routes.
Usage Information Use the vrf vrf-name attribute of this command to clear routes corresponding to either a specific VRF or the default VRF. You cannot use this attribute to clear routes corresponding to a management VRF. Related Commands ip route — assigns an IP route to the switch. show ip route — views the routing table. show ip route summary — views a summary of the routing table. clear tcp statistics Clear TCP counters.
Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. debug arp View information on ARP transactions. S4820T Syntax debug arp [interface] [count value] To stop debugging ARP transactions, use the no debug arp command.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Added support for 4094 VLANs on the E-Series ExaScale (the prior limit was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.3.1.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.4.10 Introduced on the E-Series. Example Dell#debug ip dhcp 00:12:21 : %RELAY-I-PACKET: BOOTP REQUEST (Unicast) received at interface 113.3.3.
ip helper-address hop-count disable – disables the hop-count increment for the DHCP relay agent. debug ip icmp View information on the internal control message protocol (ICMP). S4820T Syntax debug ip icmp [interface] [count value] To disable debugging, use the no debug ip icmp command. Parameters interface count value (OPTIONAL) Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Example Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Added support for 4094 VLANs on the E-Series ExaScale (the prior limit was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.3.1.0 Added the count option. ICMP: ICMP: ICMP: ICMP: ICMP: ICMP: ICMP: ICMP: echo request rcvd from src 40.
• For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For the Management interface on the stack-unit, enter the keyword ManagementEthernet then the slot/port information. The slot range is from 0 to 1. The port range is 0. • For a port channel interface, enter the keywords portchannel then a number. The range is from 1 to 128.
Field Description d= Lists the destination address of the packet and the name of the interface (in parentheses) through which the packet is being sent out on the network. len Displays the packet’s length. sending, rcvd, fragment, sending broad/multicast proto, unroutable The last part of each line lists the status of the packet. TCP src= Displays the source and destination ports, the sequence number, the acknowledgement number, and the window size of the packets in that TCP packets.
The access-group option supports only the equal to (eq) operator in TCP ACL rules. Port operators not equal to (neq), greater than (gt), less than (lt), or range are not supported in access-group option (refer to the following example). ARP packets (arp) and Ether-type (ether-type) are also not supported in the accessgroup option. The entire rule is skipped to compose the filter.
Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. ip domain-list Configure names to complete unqualified host names. S4820T Syntax ip domain-list name To remove the name, use the no ip domain-list name command.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. To configure a list of possible domain names, configure the ip domain-list command up to six times. If you configure both the ip domain-name and ip domain-list commands, the software tries to resolve the name using the ip domain-name command.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. To fully enable DNS, also specify one or more domain name servers with the ip name-server command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.
Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Added support for IPv6. 8.3.19.0 Introduced on the S4820T. 8.3.11.
ip helper-address hop-count disable Disable the hop-count increment for the DHCP relay agent. S4820T Syntax ip helper-address hop-count disable To re-enable the hop-count increment, use the no ip helper-address hopcount disable command. Defaults Enabled; the hops field in the DHCP message header is incremented by default. Command Modes CONFIGURATION Command History This guide is platform-specific.
ip host Assign a name and an IP address to the host-to-IP address mapping table. S4820T Syntax ip host name ip-address To remove an IP host, use the no ip host name [ip-address] command. Parameters name Enter a text string to associate with one IP address. ip address Enter an IP address, in dotted decimal format, to be mapped to the name. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
ip icmp source-interface Enable the ICMP error and unreachable messages to be sent with the source interface IP address, such as the loopback address, instead of the hops of the preceding devices along the network path to be used for easy debugging and diagnosis of network disconnections and reachability problems with IPv4 packets.
address to be used in the ICMP unreachable messages and in the traceroute command output. The loopback address must be unique in a particular domain. In network environments that contain a large number of devices, ranging up to thousands of systems, and with each device configured for equal-cost multipath (ECMP) links, you cannot effectively and optimally use the traceroute and ping applications to examine the network reachablity and identify any broken links for diagnostic purposes.
Defaults Not configured. Command Modes CONFIGURATION Command History Usage Information • For a port channel interface, enter the keywords portchannel then a number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S4810, S4820T, S6000, and Z9000 platforms.
To place no limit on the number of fragments allowed, use the no ip max-fragcount command. Parameters count Enter a number for the number of fragments allowed for reassembly. The range is from 2 to 256. Defaults No limit is set on number of fragments allowed. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
max-number Enter the maximum number of protocol routes that a VRF RTM can hold. The range is from 0 to 7500. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version 9.4. (0.0) Introduced on the S4810 and S4820T.
Usage Information Verison Description 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 6.1.1.0 Introduced on the E-Series. When you enter the no mtu command, Dell Networking OS reduces the ip mtu value to 1536 bytes. To return the IP MTU value to the default, use the no ip mtu command. Starting with Dell Networking OS Release 9.2(0.
Related Commands Layer 2 Overhead Difference between Link MTU and IP MTU Untagged Packet with VLAN-Stack Header 22 bytes Tagged Packet with VLAN-Stack Header 26 bytes mtu — sets the link MTU for an Ethernet interface. ip name-server Enter up to six IPv4 addresses of name servers. The order you enter the addresses determines the order of their use. S4820T Syntax ip name-server ipv4-address [ipv4-address2...ipv4-address6] To remove a name server, use the no ip name-server ip-address command.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Dell Networking OS does not support sending DNS queries over a VLAN. DNS queries are sent out on all other interfaces, including the Management port. You can separately configure both IPv4 and IPv6 domain name servers.
Related Commands Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. show ip interface — displays the interface routing status and configuration. ip route Assign a static route to the switch.
• For the Management interface on the stack-unit, enter the keyword ManagementEthernet then the slot/port information. The slot range is from 0 to 1. The port range is 0. • For a port channel interface, enter the keywords portchannel then a number. • For a Null interface, enter the keyword null then the Null interface number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. • For a tunnel interface, enter the keyword tunnel then the tunnel interface number.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Included the weighted parameter to support weighted ECMP feature. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 9.2.(0.
You can specify the weight value only to destination address and not on the egress port. A route is considered for weighted ECMP calculations only if each paths corresponding to that route is configured with a weight. You cannot use the VRF attribute of this command to configure routes in a management VRF. When a specific VRF is deleted, all the configured static routes corresponding to that VRF are automatically removed. Example Dell(conf)#ip route 1.1.1.0/24 4.4.4.2 weight 100 Dell(conf)#ip route 1.1.1.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. ip tcp initial-time Define the wait duration in seconds for the TCP connection to be established. This command is supported on the , S4820T, , and platforms.
show ip tcp initial-time Displays the interval that you configured for the device to wait before the TCP connection is attempted to be established. Syntax show ip tcp initial-time Command Modes EXEC EXEC Privilege Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S4810, S4820T, S6000, Z9000, and MXL platforms. ip unreachables Enable the generation of internet control message protocol (ICMP) unreachable messages.
Version Description 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. load-balance By default, for C-Series and S-Series, Dell Networking OS uses an IP 4-tuple (IP SA, IP DA, Source Port, and Destination Port) to distribute IP traffic over members of a Port Channel as well as equal-cost paths.
source port ID fields to hash. The hashing mechanism returns a 3-bit index indicating which port the packet should be forwarded. • tcp-udp enable Enter the keywords to distribute traffic based on the following: • ingress-port enable source-mac — Uses the source MAC address, VLAN, Ethertype, source module ID and source port ID fields to hash. The hashing mechanism returns a 3-bit index indicating which port the packet should be forwarded.
• TCP/UDP destination port load-balance hg Choose the traffic flow parameters the hash calculation uses while distributing the traffic across internal higig links.
mac [sourcemac | sourceport-id | sourcemodule-id | dest-mac | dest-port-id | dest-moduleid | vlan | ethertype | source-destmac ] tunnel [ipv4over-ipv4 | ipv4-over-greipv4 | mac-inmac]} To use MAC key fields in hash computation, enter the keyword mac then one of the parameters: • source-mac — Use source-mac field in hash calculation. • source-port-id — Use src-port-id field in hash calculation. • source-module-id — Use src-module-id field in hash calculation.
management route Configure a static route that points to the Management interface or a forwarding router. S4820T Syntax management route {{ip-address mask | {ipv6-address prefixlength}} {forwarding-router-address | managementethernet | fortyGigE | vlan | tengigabitethernet} To remove a static route, use the no management route{{ip-address mask | {ipv6-address prefix-length}}{forwarding-router-address | managementethernet | fortyGigE | vlan | gigabitethernet | tengigabitethernet} command.
Version Description 9.7(0.0) Added support for forty gigabit, vlan, and tengigabit ethernet interfaces. Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000 and added support for IPv6. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series.
• For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For the Management interface on the stack-unit, enter the keyword ManagementEthernet then the slot/port information. The slot range is from 0 to 1. The port range is 0. • For a port channel interface, enter the keywords portchannel then a number. The range is from 1 to 128.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Added support for 4094 VLANs on the E-Series ExaScale (the prior limit was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.9.1.0 Introduced VRF on the E-Series. 7.8.1.0 Augmented to display local ARP entries learned from private VLANs (PVLANs).
Internet Internet Internet Internet Internet Internet Internet Internet Internet Example (Private VLAN) 192.2.1.251 192.2.1.250 192.2.1.251 192.2.1.250 192.2.1.249 192.2.1.248 192.2.1.247 192.2.1.246 192.2.1.
show arp retries Display the configured number of ARP retries. S4820T Syntax show arp retries Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Added support for IPv6 addresses. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. The following describes the show hosts command in the following example. Field Description Default domain...
Example Related Commands Dell#show hosts Default domain is not set Name/address lookup uses static Name servers are not set Host Flags TTL Type -------- -------- ---ks (perm, OK) IP 4200-1 (perm, OK) IP 1230-3 (perm, OK) IP ZZr (perm, OK) IP Z10-3 (perm, OK) IP Dell# mappings Address ------2.2.2.2 192.68.69.2 192.68.99.2 192.71.18.2 192.71.23.1 traceroute — views the DNS resolution. ip host — configures a host. show ip cam linecard View CAM entries for a port pipe on a line card.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information 944 Version 8.3.19.0 Introduced on the S4820T. Version 8.3.7.0 Introduced on the S4810. Version 8.1.1.2 Introduced on the E-Series ExaScale E600i. Version 8.1.1.0 Introduced on the E-Series ExaScale. Version 7.9.1.
Field Description • So = SONET interface • Te = 10-Gigabit Ethernet interface Example Dell#show ip cam linecard 13 port-set 0 Index Destination EC CG V C Next-Hop VId Mac-Addr Port ------ ----------------------------------- ---- ------------3276 6.6.6.2 0 0 1 1 0.0.0.0 0 00:00:00:00:00:00 17c1 CP 3277 5.5.5.2 0 0 1 1 0.0.0.0 0 00:00:00:00:00:00 17c1 CP 3278 4.4.4.2 0 0 1 1 0.0.0.0 0 00:00:00:00:00:00 17c1 CP 3279 3.3.3.2 0 0 1 1 0.0.0.0 0 00:00:00:00:00:00 17c1 CP 3280 2.2.2.2 0 0 1 1 0.0.0.
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Dell# 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1312 1312 1312 1312 1312 1312 1312 1312 1312 1312 1312 1312 1312 1312 1312 8 show ip cam stack-unit Display CAM entries for a port-pipe of a stack-unit on a S-Series or Z-Series switch.
• summary Enter the keyword group-index then the index number to show ECMP membership per group. The range is from 0 to 1022. (OPTIONAL) Enter the keyword summary to view a table listing route prefixes and the total number routes which can be entered in to CAM. Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Example Dell#show ip cam stack-unit 3 po 0 1.1.1.0/24 longer-prefixes Destination EC C VId Mac-Addr Port ------------------------------------------------------------------1.1.1.2/32 0 0 3000 00:05:00:00:00:02 Te 3/44 1.1.1.1/32 0 1 0 00:00:00:00:00:00 CP 1.1.1.
show ip fib linecard View all forwarding information base (FIB) entries. S4820T Syntax Parameters show ip fib linecard slot-number [vrf vrf instance | ipaddress/prefix-list | summary] vrf instance (OPTIONAL) E-Series Only: Enter the keyword vrf then the VRF instance name to show the FIB cache entries tied to that VRF instance. slot-number Enter the number of the line card slot. ip-address mask (OPTIONAL) Enter the IP address of the network destination to view only information on that destination.
Example Field Description Destination Lists the destination IP address. Gateway Displays either the word “direct” and an interface for a directly connected route or the remote IP address used to forward the traffic. First-Hop Displays the first hop IP address. Mac-Addr Displays the MAC address. Port Displays the egress-port information. VId Displays the VLAN ID. If no VLAN is assigned, zero (0) is listed. Index Displays the internal interface number. EC Displays the number of ECMP paths.
Parameters id Enter the S-Series stack unit ID. The unit ID range is from 0 to 11 for the S4820T. vrf vrf-name Enter the keyword vrf followed by the name of the VRF to view FIB entries corresponding to that VRF. ip-address mask (OPTIONAL) Enter the IP address of the network destination to view only information on that destination. Enter the IP address in dotted decimal format (A.B.C.D). Enter the mask in slash prefix format (/X).
Field Description Mac-Addr Displays the MAC address. Port Displays the egress-port information. VId Displays the VLAN ID. If no VLAN is assigned, zero (0) is listed. EC Displays the number of ECMP paths. If weighted ECMP is enabled, then the show ip fib stack-unit command display a new column named W-EC (Weighted ECMP). This column displays either a value of 1 or 0 depending on whether or not a route is assigned with a weight.
The RC and W columns in the show output appear only if the weighted ECMP is enabled using the ip ecmp weighted command. Related Commands clear ip fib stack-unit — clear FIB entries on a specified stack-unit. ip ecmp weighted— enables weighted ECMP calculations. show ip flow Show how a Layer 3 packet is forwarded when it arrives at a particular interface.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.10.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.1.1.0 Introduced on the E-Series ExaScale. 7.9.1.0 Introduced VRF on the E-Series. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series.
Parameters interface (OPTIONAL) Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383.
Usage Information Example Version Description 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.1.1.2 Supported on the E-Series ExaScale E600i. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. The following describes the show ip interface command shown in the following example. Lines Description TenGigabitEthern et 1/1...
Example (Brief) Fields Description Interface Displays type of interface and the associated slot and port number. IP-Address Displays the IP address for the interface, if configured. Ok? Indicates if the hardware is functioning properly. Method Displays “Manual” if the configuration is read from the saved configuration. Status States whether the interface is enabled (up) or disabled (administratively down). Protocol States whether IP is enabled (up) or disabled (down) on the interface.
static (OPTIONAL) Enter the keyword static to view non-active routes also. Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
summary (OPTIONAL) Enter the keyword summary to view a table listing the number of active and non-active routes and their sources. static (OPTIONAL) Enter the keyword static to view non-active routes also. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Regular evaluation optimization enabled/disabled added to display output. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.
Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the VRF name to list the routes in the route table of a specific VRF. ip-address (OPTIONAL) Specify a name of a device or the IP address of the device to view more detailed information about the route. mask (OPTIONAL) Specify the network mask of the route. Use this parameter with the IP address parameter. longer-prefixes (OPTIONAL) Enter the keywords longer-prefixes to view all routes with a common prefix.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.9.1.0 Introduced VRF on the E-Series. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series.
Field Description Gateway Identifies whether the route is directly connected and on which interface the route is configured. Dist/Metric Identifies if the route has a specified distance or metric. Last Change Identifies when the route was last changed or configured. The weight for weighted ECMP route calculations is displayed for each path in the route in show ip route command. The ECMP weight is displayed only if weighted ECMP is enabled using the ip ecmp weighted command is enabled.
Codes: C - connected, S - static, R - RIP, B - BGP, IN - internal BGP, EX - external BGP,LO Locally Originated, O - OSPF, IA - OSPF inter area, N1 - OSPF NSSA external type 1, N2 - OSPF NSSA external type 2, E1 - OSPF external type 1, E2 - OSPF external type 2, i - IS-IS, L1 - IS-IS level-1, L2 - IS-IS level-2, IA - IS-IS inter area, * candidate default, > - non-active route, + - summary route Gateway of last resort is not set C Example (With Weighted ECMP Enabled) Destination ----------13.0.0.
Example (With Weighted ECMP Disabled) Dell(conf)#ip route 1.1.1.0/24 6.6.6.2 weight 100 Dell(conf)#ip route 1.1.1.0/24 6.6.6.
Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.
show ip route summary View a table summarizing the IP routes in the switch. S4820T Syntax Parameters show ip route vrf vrf-name summary vrf vrf-name Enter the keyword vrf followed by the name of the VRF to view information on the IP routes corresponding to that VRF. Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Example Column Heading Description Non-active Routes Identifies the back-up routes when a route is learned by two different protocols. If the best route or active route goes down, the non-active route becomes the best route. ospf 100 If routing protocols (OSPF, RIP) are configured and routes are advertised, then information on those routes is displayed. Total 1388 active... Displays the number of active and non-active routes and the memory usage of those routes.
rp2 (OPTIONAL) Enter the keyword rp2 to view only the statistics from Route Processor 2. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information IPv4 Routing Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Keyword Definition ... timeouts Number of times a timer expired on a reassembled queue. ... too big Number of invalid IP fragments received. ... couldn’t fragment Number of packets that could not be fragmented and forwarded. ...encapsulation failed Counts packets which could not be forwarded due to ARP resolution failure. Dell Networking OS sends an arp request prior to forwarding an IP packet. If a reply is not received, Dell Networking OS repeats the request three times.
Bcast: 28 received, 0 sent; Mcast: 0 received, 0 sent Sent: 16048 generated, 0 forwarded 21 encapsulation failed, 0 no route ICMP statistics: Rcvd: 0 format errors, 0 checksum errors, 0 redirects, 0 unreachable 0 echo, 0 echo reply, 0 mask requests, 0 mask replies, 0 quench 0 parameter, 0 timestamp, 0 info request, 0 other Sent: 0 redirects, 0 unreachable, 0 echo, 0 echo reply 0 mask requests, 0 mask replies, 0 quench, 0 timestamp 0 info reply, 0 time exceeded, 0 parameter problem UDP statistics: Rcvd: 0 to
Usage Information 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 6.4.1.0 Introduced The following describes the show tcp statistics cp command shown in the following example. Field Description Rcvd: Displays the number and types of TCP packets received by the switch. 0 checksum error...
Example Field Description Sent: Displays the total number of TCP packets sent and the number of urgent packets sent. 25 control packets... Displays the number of control packets sent and the number retransmitted. 11603 data packets... Displays the number of data packets sent. 24 data packets retransmitted Displays the number of data packets resent. 355 ack.. Displays the number of acknowledgement packets sent and the number of packet delayed. 0 window probe...
dropped in keepalive Dell# Related Commands 974 show ip cam stack-unit — displays the CAM table.
IPv6 Access Control Lists (IPv6 ACLs) 27 IPv6 ACLs and IPv6 Route Map commands are supported on Dell Networking S4820T platform. NOTE: For IPv4 ACL commands, refer to the Access Control Lists (ACL) chapter. Important Points to Remember • Certain platforms require manual CAM usage space allotment. For more information, refer to the cam-acl command. • Egress IPv6 ACL and IPv6 ACL on the Loopback interface is not supported. • Reference to an empty ACL permits any traffic.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.4.2.1 Introduced on the S-Series. 8.4.2.0 Introduced on the E-Series TeraScale. 7.8.1.0 Introduced on the C-Series.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.4.2.1 Introduced on the S-Series. 8.4.2.0 Introduced on the E-Series TeraScale. 7.8.1.0 Introduced on the C-Series.
Example (Manual Profiles) Dell#show cam-acl -- Chassis Cam ACL -Current Settings(in block sizes) L2Acl : 2 Ipv4Acl : 2 Ipv6Acl : 4 Ipv4Qos : 2 L2Qos : 3 -- Line card 4 -Current L2Acl : Ipv4Acl : Ipv6Acl : Ipv4Qos : L2Qos : Settings(in block sizes) 2 2 4 2 3 Dell#show cam-acl Related Commands cam-acl — configures CAM profiles to support IPv6 ACLs. permit icmp To allow all or specific internet control message protocol (ICMP) messages, configure a filter.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.4.2.1 Introduced on the S-Series. 8.2.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series TeraScale. Added the monitor option. permit To configure a filter that matches the filter criteria, select an IPv6 protocol number, ICMP, IPv6, TCP, or UDP.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. ipv6 control-plane egress-filter Enable egress Layer 3 ACL lookup for IPv6 CPU traffic.
ipv6 access-list Configure an access list based on IPv6 addresses or protocols. S4820T Syntax ipv6 access-list access-list-name cpu-qos {permit | deny} ospfv3 To delete an access list, use the no ipv6 access-list access-list-name command. Parameters access-listname Enter the access list name as a string, up to 140 characters. cpu-qos Enter the keyword cpu-qos to assign this ACL to control plane traffic only (CoPP).
Usage Information Version Description 7.8.1.0 Introduced on the C-Series. Increased the name string to accept up to 140 characters. Prior to version 7.8.1.0, names are up to 16 characters long. 7.4.1.0 Introduced on the E-Series TeraScale. The number of entries allowed per ACL is hardware-dependent. For detailed specification on entries allowed per ACL, refer to your line card documentation.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.4.2.0 Introduced on the E-Series TeraScale. 8.2.1.0 Introduced on the S-Series. 7.8.1.0 Introduced on the C-Series. For the new settings to take effect, save the new CAM settings to the startupconfig (write-mem or copy run start), then reload the system. The total amount of space allowed is 4 FP Blocks.
l2acl 1-10 ipv4acl 1-10 ipv6acl 0-10 ipv4qos 1-10 l2qos 1-10 Allocate space to support IPv6 ACLs. Enter all of the profiles and a range. Enter the CAM profile name then the amount to be allotted. The total space allocated must equal 13. The ipv6acl range must be a factor of 2. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
28 IPv6 Basics IPv6 basic commands are supported on the Dell Networking OS. NOTE: For information about the Dell Networking operating software version and platform that supports IPv6 in each software feature, refer to the IPv6 Addressing chapter of the Dell Networking OS Configuration Guide. clear ipv6 fib Clear (refresh) all forwarding information base (FIB) entries on a linecard or stack unit.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series TeraScale. clear ipv6 route Clear (refresh) all or a specific route from the IPv6 routing table.
Version Description 8.2.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series TeraScale. clear ipv6 mld_host Clear the IPv6 MLD host counters and reset the elapsed time. S4820T Syntax clear ipv6 mld_host Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Parameters limit Maximum number of IPv6 routes allowed in a VRF. Valid range is from 1 to 8000 (or maximum allowable for that platform if smaller value). warningthreshold Warning threshold value is expressed as a percentage of the limit value. When the number of IPv6 routes reaches the specified percentage of the limit, a warning message is generated. Valid range is 1 to 100.
Default Disabled Command Modes INTERFACE (management interface only) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Infomation Version Description 9.1.(0.0) Updated Usage Information section. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810.
Parameters ipv6-address prefix-length Enter the IPv6 address in the x:x:x:x::x format then the prefix length in the /x format. The range is from /0 to /128. NOTE: The :: notation specifies successive hexadecimal fields of zeros. Defaults none Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
! interface TenGigabitEthernet 1/2 no ip address ipv6 address 2002:1:2::3 /96 no shutdown ipv6 address eui64 Configure IPv6 EUI64 address configuration on the interface. S4820T Syntax ipv6 address {ipv6-address prefix-length} eui64 To disable IPv6 EUI64 address autoconfiguration, use the no ipv6 address {ipv6-address prefix-length} eui64 command. Parameters ipv6-address prefix-length Enter the IPv6 prefix in the x:x:x:x::x format then the prefix length in the /x format. The range is from /0 to /128.
ipv6 control-plane icmp error-rate-limit Configure the maximum number of ICMP error packets per second that can be sent per second. S4820T Syntax ipv6 control-plane icmp error-rate-limit {1-200} To restore the default value, use the no ipv6 control-plane icmp errorrate-limit command. Parameters pps Enter the maximum number of error packets generated per second. The range is from 1 to 200, where 0 disables the rate-limiting.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.4.2.1 Introduced on the C-Series and S-Series. 8.4.1.0 Introduced on the E-Series TeraScale. ipv6 name-server Enter up to six IPv6 addresses of name servers. The order you enter the addresses determines the order of their use. S4820T Syntax ipv6 name-server ipv6-address [ipv6-address2... ipv6-address6] To remove a name server, use the no ipv6 name—server ipv6–address command.
Usage Information Version Description 8.4.2.1 Introduced on the C-Series and S-Series. 8.4.1.0 Introduced on the E-Series TeraScale. You can separately configure both IPv4 and IPv6 domain name servers. ipv6 nd dad attempts To perform duplicate address detection (DAD) on the management interface, configure the number of neighbor solicitation messages that are sent. S4820T Syntax ipv6 nd dad attempts {number of attempts} To restore the default value, use the no ipv6 nd dad attempts command.
ipv6 nd dns-server Configures Recursive DNS Server (RDNSS) addresses to be distributed via IPv6 router advertisements to an IPv6 device. Syntax ipv6 nd dns-server {ipv6-RDNSS-address} {lifetime | infinite} To remove the IPv6 RDSS configuration, use no ipv6 nd dns-server {ipv6RDNSS-address} {lifetime | infinite} Parameters ipv6-RDNSSaddress Enter the IPv6 Recursive DNS Server’s (RDNSS) address. You can specify up to 4 IPv6 RDNSS server addresses. lifetime Enter the lifetime in seconds.
ipv6 nd prefix Specify which IPv6 prefixes are included in Neighbor Advertisements. S4820T Syntax Parameters ipv6 nd prefix {ipv6-prefix | prefix-length | default} [noadvertise] | [no-autoconfig] [no-rtr-address] [off-link] [lifetime {valid | infinite} {preferred | infinite}] ipv6-prefix Enter an IPv6 prefix. prefix-length Enter the prefix then the prefix length. The length range is from 0 to 128. default Enter the keyword default to set default parameters for all prefixes.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.2.0 Introduced on the E-Series TeraScale, C-Series, and SSeries. By default, all prefixes configured as addresses on the interface are advertised. This command allows control over the individual parameters per prefix; you can use the default keyword to use the default parameters for all prefixes.
• For a port channel interface, enter the keywords portchannel then a number. • For a Null interface, enter the keyword null then the Null interface number. • For a tunnel interface, enter the keyword tunnel then the tunnel interface number. The range is from 1 to 16383. • For a VLAN interface, enter the keyword VLAN then the vlan number. The range is from 1 to 4094.
Usage Information Version Description 9.7(0.0) Added support for VRF. Also included the weight parameter to support weighted ECMP feature. Introduced on the S6000-ON. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.2.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series TeraScale.
ipv6 unicast-routing Enable IPv6 Unicast routing. S4820T Syntax ipv6 unicast-routing To disable unicast routing, use the no ipv6 unicast-routing command. Defaults Enabled Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.0.0.
show ipv6 cam stack-unit Displays the IPv6 CAM entries for the specified stack-unit. S4820T Syntax Parameters show ipv6 cam [vrf vrf-name] stack-unit unit-number port-set {0-1} [summary | index | ipv6 address] vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to display IPv6 CAM entries corresponding to that VRF. NOTE: If you do not specify this option, IPv6 CAM entries corresponding to the default VRF are displayed. unit-number Enter the stack unit’s ID number.
Usage Information First-Hop information is not shown for installed routes in the IPv6 content addressable memory (CAM). However, the same is shown in the forwarding information base (FIB). NOTE: If a route has a mask greater than 64, no output is displayed and no output is displayed for show ipv6 cam stack-unit unit-number portset {0-1} ipv6-address, but an equivalent /64 entry would be listed in the show ipv6 cam stack-unit unit-number port-set {0-1} output.
show ipv6 fib stack-unit View all FIB entries. S4820T Syntax Parameters show ipv6 fib [vrf vrf-name] stack-unit unit-number [summary | ipv6-address] vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to display neighbors corresponding to that VRF. slot-number Enter the number of the stack unit. summary (OPTIONAL) Enter the keyword summary to view a summary of entries in IPv6 cam.
show ipv6 flowlabel-zero Display the flow label zero setting. S4820T Syntax show ipv6 flowlabel-zero Default Disabled Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.
• For a port channel interface, enter the keywords portchannel then a number. • For a Null interface, enter the keyword null then the Null interface number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. • For stacking, enter the keywords stack-unit then the stack-unit ID. • For a tunnel interface, enter the keyword tunnel then the tunnel ID. brief (OPTIONAL) View a summary of IPv6 interfaces.
Version Description 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.4.2.1 Introduced on the S-Series. 8.2.1.0 Introduced on the E-Series ExaScale. Added support for the managementethernet slot/port parameter. 7.8.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series TeraScale. Usage Information The Management port is enabled by default (no shutdown). If necessary, use the ipv6 address command to assign an IPv6 address to the Management port.
ND hop limit is 64 Dell# Example (Brief) Example (tunnel) Dell#show ipv6 interface brief TenGigabitEthernet 1/2 fe80::201:e8ff:fea7:497e 2002:1:2::3/96 TenGigabitEthernet 1/12 fe80::201:e8ff:fea7:497e 100::2/64 ManagementEthernet 1/0 fe80::201:e8ff:fea7:497e 300::1/64 Dell# [administratively down/down] [up/up] [up/up] Dell#show ipv6 interface tunnel 1 Tunnel 1 is up, line protocol is up IPV6 is enabled Link Local address: fe80::201:e8ff:fea7:497e Global Unicast address(es): 400::1, subnet is 400::/64 (M
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example IPv6 Basics Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. The following describes the show ipv6 mld-host command shown in the following example.
show ipv6 route Displays the IPv6 routes. S4820T Syntax Parameters show ipv6 route [ipv6-address prefix-length] [vrf vrf-name] [hostname] [all] [bgp as number] [connected] [isis tag] [list prefix-list name] [ospf process-id] [rip] [static] [summary] ipv6-address prefix-length (OPTIONAL) Enter the IPv6 address in the x:x:x:x::x format then the prefix length in the /x format. The range is from /0 to /128. NOTE: The :: notation specifies successive hexadecimal fields of zeros.
The following is a list of the Dell Networking OS version history for this command. Usage Information IPv6 Basics Version Description 9.7(0.0) Added support for VRF. Introduced on S6000–ON 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series TeraScale.
Example (SSeries) Field Description Dist/Metric Identifies if the route has a specified distance or metric. Last Change Identifies when the route was last changed or configured.
Example (Summary) show ipv6 route summary: ====================================== Dell#show ipv6 route summary Route Source Active Routes connected 3 static 1 Total 4 Total 4 active route(s) using 928 bytes Dell# Non-active Routes 0 0 0 trust ipv6-diffserv Allows the dynamic classification of IPv6 DSCP. S4820T Syntax trust ipv6-diffserv To remove the definition, use the no trust ipv6-diffserv command.
IPv6 Service Class Field Queue ID 111XXXXX 7 110XXXXX 6 101XXXXX 5 100XXXXX 4 011XXXXX 3 010XXXXX 2 001XXXXX 1 000XXXXX 0 IPv6 Basics
iSCSI Optimization 29 Internet small computer system interface (iSCSI) optimization enables quality-of-service (QoS) treatment for iSCSI storage traffic on an S4820T system. To configure and verify the iSCSI optimization feature, use the following Dell Networking OS commands. advertise dcbx-app-tlv Configure DCBX to send iSCSI TLV advertisements. S4820T Syntax advertise dcbx-app-tlv iscsi To disable DCBX iSCSI TLV advertisements, use the no advertise dcbx-apptlv iscsi command. Defaults Disabled.
iscsi aging time Set the aging time for iSCSI sessions. S4820T Syntax iscsi aging time time To remove the iSCSI session aging time, use the no iscsi aging time command. Parameters time Enter the aging time for the iSCSI session. The range is from 5 to 43,200 minutes. Defaults 10 minutes Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
is: the iSCSI packets are handled with dotp1 priority 4 without remark. disable Enter the keyword disable to disable the application of preferential QoS treatment to iSCSI frames. dot1p vlanpriority-value Enter the dot1p value of the VLAN priority tag assigned to the incoming packets in an iSCSI session. The range is from 0 to 7.
Parameters enable Enter the keyword enable to enable the iSCSI optimization feature. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.
iscsi profile-compellant Configure the auto-detection of Dell Compellent arrays on a port. S4820T Syntax iscsi profile-compellent Defaults Dell Compellent disk arrays are not detected. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.
Defaults 860, 3260 Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on MXL 10/40GbE Switch IO Module.
iSCSI COS : dot1p is 4 no-remark Session aging time: 10 Maximum number of connections is 256 -----------------------------------------------iSCSI Targets and TCP Ports: -----------------------------------------------TCP Port Target IP Address 3260 860 Related Commands • show iscsi session — displays information about active iSCSI sessions on the switch. • show iscsi session detailed — displays detailed information about active iSCSI sessions on the switch. • show run iscsi — shows run iscsi.
Initiator: iqn.1991-05.com.microsoft:win-x9l8v27yajg ISID: 400001370000. Usage Information Only sessions the switch observes are learned; sessions flowing through an adjacent switch are not learned. After the switch is reloaded, any information exchanged during the initial handshake is not available. If the switch picks up the communication after reloading, it would detect a session was in progress but could not obtain complete information for it.
Time for aging out:00:00:09:34(DD:HH:MM:SS) ISID:806978696102 Initiator Initiator Target Target Connection IP Address TCP Port IP Address TCPPort ID 10.10.0.44 33345 10.10.0.101 3260 0 Session 1 : ---------------------------------------------------Target:iqn.2010-11.com.ixia:ixload:iscsi-TG1 Initiator:iqn.2010-11.com.ixia.
Intermediate System to Intermediate System (IS-IS) 30 The intermediate system to intermediate system (IS-IS) protocol for IPv4 and IPv6 is supported on the S4820T platform. IS-IS is an interior gateway protocol that uses a shortest-path-first algorithm. IS-IS facilitates the communication between open systems, supporting routers passing both IP and OSI traffic. A router is considered an intermediate system. Networks are partitioned into manageable routing domains, called areas.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.5.1.0 Introduced on the E-Series. To perform protocol-support consistency checks on hello packets, use this command. The adjacency-check is enabled by default.
• Command History CONFIGURATION-ROUTER-ISIS-ADDRESS-FAMILY-IPV6 (for IPv6) This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.
Defaults Not configured. Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.1 Introduced on the S4810. Usage Information CAUTION: Use caution when you enter this command. Back up your configuration prior to using this command or your IS-IS configuration will be erased. clear isis Restart the IS-IS process. All IS-IS data is cleared.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. clns host Define a name-to-network service mapping point (NSAP) that you use with commands that require NSAPs and system IDs. Syntax Parameters clns host name nsap name Enter an alphanumeric string to identify the name-to-NSAP mapping. nsap Enter a specific NSAP address that is associated with the name parameter. Defaults Not configured.
debug isis Enable debugging for all IS-IS operations. Syntax debug isis To disable debugging of IS-IS, use the no debug isis command. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
adjacency tied to that VRF. This command displays the IIH related debug details. interface (OPTIONAL) Identifies the interface type slot/port as one of the following: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords portchannel then a number.
corresponding to that VRF. This information contains local updates tied to the VRF that you specify. This command displays the local LSP debugging details of the current unit. interface (OPTIONAL) Identifies the interface type slot/port as one of the following: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
Parameters vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to enable debugging information on ISIS for CSNP/PSNP packets tied to that VRF. The command displays the SNP (CSNP/PSNP) related debugging information. interface (OPTIONAL) Identifies the interface type slot/port as one of the following: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
To turn off debugging, use the no debug isis [vrf vrf-name] spftriggers command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to enable debugging information on IS-IS corresponding to that VRF. This information contains spf trigger detail tied to the VRF that you specify. When SPF is triggered, this debugging information is displayed. Command Modes EXEC Privilege Command History This guide is platform-specific.
interface (OPTIONAL) Identifies the interface type slot/port as one of the following: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords portchannel then a number. The range is from 1 to 128. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094.
metric metric (OPTIONAL) Enter the keyword metric then a number to assign to the route. The range is from 0 to 16777215. route-map map-name (OPTIONAL) A default route the routing process generates if the route map is satisfied. Defaults Not configured. Command Modes • ROUTER ISIS (for IPv4) • CONFIGURATION-ROUTER-ISIS-ADDRESS-FAMILY-IPV6 (for IPv6) Command History This guide is platform-specific.
description Enter a description of the IS-IS routing protocol. Syntax description {description} To remove the description, use the no description {description} command. Parameters description Defaults none Command Modes ROUTER ISIS Command History Related Commands Enter a description to identify the IS-IS protocol (80 characters maximum). Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.
Defaults Command Modes Command History ip-address mask (OPTIONAL) Enter the next-hop address in dotted decimal format and enter a mask in either dotted decimal or /prefix format. prefix-list (OPTIONAL) Enter the name of a prefix list name. weight = 115 • ROUTER ISIS (for IPv4) • CONFIGURATION-ROUTER-ISIS-ADDRESS-FAMILY-IPV6 (for IPv6) This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
interface (OPTIONAL) Identifies the interface type slot/port as one of the following: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords portchannel then a number. The range is from 1 to 128. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Defaults Not configured.
To return to the default values, use the no distribute-list prefix-listname out [bgp as number connected | ospf process-id | rip | static] command. Parameters prefix-listname Specify the prefix list to filter prefixes in routing updates. connected (OPTIONAL) Enter the keyword connected for directly connected routing process. ospf process-id (OPTIONAL) Enter the keyword ospf then the OSPF process-ID number. The range is from 1 to 65535. bgp as number (OPTIONAL) Enter the BGP then the AS Number.
distribute-list redistributed-override Suppress flapping of routes when the same route is redistributed into IS-IS from multiple routers in the network. Syntax distribute-list redistributed-override in To return to the default, use the no distribute-list redistributedoverride in command. Defaults none Command Modes • ROUTER ISIS (for IPv4) • CONFIGURATION-ROUTER-ISIS-ADDRESS-FAMILY-IPV6 (for IPv6) Command History This guide is platform-specific.
Parameters hmac-md5 (OPTIONAL) Enter the keywords hmac-md5 to encrypt the password using MD5. encryptiontype (OPTIONAL) Enter 7 to encrypt the password using DES. password Enter an alphanumeric string up to 16 characters long. If you do not specify an encryption type or hmac-md5 keywords, the password is processed as plain text which provides limited security. Defaults No default password. Command Modes ROUTER ISIS Command History This guide is platform-specific.
Parameters ietf Enter ietf to enable graceful restart on the IS-IS router. Defaults Graceful restart disabled. Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000.
Defaults 5 minutes Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.
Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.3.1.0 Introduced on the E-Series. graceful-restart t3 — configures the overall wait time before graceful restart completes. graceful-restart t1 Set the graceful restart wait time before unacknowledged restart requests are generated.
Version Description 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.3.1.0 Introduced on the E-Series. graceful-restart t2 Configure the wait time for the graceful restart timer T2 that a restarting router uses as the wait time for each database to synchronize. Syntax graceful-restart t2 {level-1 | level-2} seconds To return to the default, use the no graceful-restart t2 command.
graceful-restart t3 Configure the overall wait time before graceful restart completes. Syntax graceful-restart t3 {adjacency | manual} seconds To return to the default, use the no graceful-restart t3 command. Parameters adjacency Enter the keyword adjacency so that the restarting router receives the remaining time value from its peer and adjusts its T3 value so if you have configured this option. manual Enter the keyword manual to specify a time value that the restarting router uses.
Related Commands graceful-restart restart-wait — enables the graceful restart maximum wait time before a restarting peer comes up. hello padding Use to turn ON or OFF padding for LAN and point-to-point hello PDUs or to selectively turn padding ON or OFF for LAN or point-to-point hello PDUs. Syntax hello padding [multi-point | point-to-point] To return to the default, use the no hello padding [multi-point | pointto-point] command.
hostname dynamic Enables dynamic learning of hostnames from routers in the domain and allows the routers to advertise the hostname in LSPs. Syntax hostname dynamic To disable this command, use the no hostname dynamic command. Defaults Enabled. Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.5.1.0 Introduced. To assign a network entity title to enable IS-IS, use the net command. This command accepts even if an IP address is not configured. This command is cached in the L3 Manager till the IP address is configured.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.5.1.0 Introduced on the E-Series. Configure a network entity title (the net command) to specify the area address and the router system ID. To establish adjacencies and establish dynamic routing, enable routing on one or more interfaces.
Defaults level-1-2 Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.
Defaults seconds = 10; level-1 (if not otherwise specified) Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.
Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000.
Defaults multiplier = 3; level-1 (if not otherwise specified) Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. Usage Information Hello PDUs are “padded” only when both the global and interface padding options are ON. Turning either one OFF disables padding for the corresponding interface. Related Commands hello padding — turns ON or OFF padding for LAN and point-to-point hello PDUs.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.5.1.0 Introduced on the E-Series. Dell Networking recommends configuring metrics on all interfaces. Without configuring this command, the IS-IS metrics are similar to hop-count metrics. isis metric Assign a metric to an interface.
Defaults default-metric = 10; level-1 (if not otherwise specified) Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.
Version Description 8.3.11.1 Introduced on the Z9000. isis password Configure an authentication password for an interface. Syntax isis password [hmac-md5] password [level-1 | level-2] To delete a password, use the no isis password [password] [level-1 | level-2] command. Parameters encryptiontype (OPTIONAL) Enter 7 to encrypt the password using DES. hmac-md5 (OPTIONAL) Enter the keywords hmac-md5 to encrypt the password using MD5. password Assign the interface authentication password.
Usage Information To protect your network from unauthorized access, use this command to prevent unauthorized routers from forming adjacencies. You can assign different passwords for different routing levels by using the keywords level-1 and level-2. The no form of this command disables the password for Level 1 or Level 2 routing, using the respective keywords level-1 or level-2. This password provides limited security as it is processed as plain text.
Usage Information You can configure priorities independently for Level 1 and Level 2. Priorities determine which router on a LAN is the designated router. Priorities are advertised within hellos. The router with the highest priority becomes the designated intermediate system (DIS). NOTE: Routers with a priority of 0 cannot be a designated router. Setting the priority to 0 lowers the chance of this system becoming the DIS, but does not prevent it.
Usage Information The IS-IS protocol automatically determines area boundaries and are able to keep Level 1 and Level 2 routing separate. Poorly planned use of this feature may cause configuration errors, such as accidental area partitioning. If you are configuring only one area in your network, you do not need to run both Level 1 and Level 2 routing algorithms. You can configure the IS type as Level 1. log-adjacency-changes Generate a log messages for adjacency state changes.
lsp-gen-interval Set the minimum interval between successive generations of link-state packets (LSPs). Syntax lsp-gen-interval [level-l | level-2] interval seconds [initial_wait_interval seconds [second_wait_interval seconds]] To restore default values, use the no lsp-gen-interval [level-l | level-2] interval seconds [initial_wait_interval seconds [second_wait_interval seconds]] command. Parameters level-l (OPTIONAL) Enter the keywords level-1 to apply the configuration to generation of Level-1 LSPs.
Usage Information LSP throttling slows down the frequency at which LSPs are generated during network instability. Even though throttling LSP generations slows down network convergence, no throttling can result in a network not functioning as expected. If network topology is unstable, throttling slows down the scheduling of LSP generations until the topology regains its stability.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.5.1.0 Added support for LSP Throttling Enhancement. The link MTU and the LSP MTU size must be the same. Because each device can generate a maximum of 255 LSPs, consider carefully whether you use the lsp-mtu command. lsp-refresh-interval Set the link state PDU (LSP) refresh interval. LSPs must be refreshed before they expire.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.5.1.0 Added support for LSP Throttling Enhancement. The refresh interval determines the rate at which route topology information is transmitted preventing the information from becoming obsolete. The refresh interval must be less than the LSP lifetime specified with the max-lsplifetime command.
Usage Information Version Description 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.5.1.0 Added support for LSP Throttling Enhancement. To configure the number of area addresses on router, use this command. This value must be consistent with routers in the same area, otherwise the router forms only Level 2 adjacencies. The value must be same among all the routers to form Level 1 adjacencies.
The seconds parameter enables the router to keep LSPs for the specified length of time. If the value is higher, the overhead is reduced on slower-speed links. Related Commands lsp-refresh-interval — sets the link-state packet (LSP) refresh interval. maximum-paths Allows you to configure the maximum number of equal cost paths allowed in a routing table. NOTE: Enables you to configure a single system wide value that is common for both IPv4 and IPv6 addresses.
metric-style To generate and accept old-style, new-style, or both styles of type, length, and values (TLV), configure a router. Syntax metric-style {narrow [transition] | transition | wide [transition]} [level-1 | level-2] To return to the default values, use the no metric-style {narrow [transition] | transition | wide [transition]} [level-1 | level-2] command. Parameters narrow Allows you to generate and accept old-style TLVs. The metric range is from 0 to 63.
When wide transition is configured, narrow metric is sent for the narrow metric TLV and the actual wide metric is sent in wide metric TLV. The receiver can choose to use the metric that is requires. Related Commands isis metric — configures a metric for an interface. multi-topology Enables multi-topology IS-IS. It also allows enabling/disabling of old and new style TLVs for IP prefix information in the LSPs.
net To configure an IS-IS network entity title (NET) for a routing process, use this mandatory command. If you did not configure a NET, the IS-IS process does not start. Syntax net network-entity-title To remove a net, use the no net network-entity-title command. Parameters networkentity-title Specify the area address and system ID for an IS-IS routing process. The first 1 to 13 bytes identify the area address. The next 6 bytes identify the system ID.
• For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords portchannel then a number. The range is from 1 to 128. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Defaults Not configured.
Parameters Defaults Command Modes Command History connected Enter the keyword connected to redistribute active routes into IS-IS. rip Enter the keyword rip to redistribute RIP routes into IS-IS. static Enter the keyword static to redistribute user-configured routes into IS-IS. metric metricvalue (OPTIONAL) Assign a value to the redistributed route. The range is from 0 to 16777215. The default is 0. Use a value that is consistent with the destination protocol.
Usage Information Version Description 8.3.12.0 Introduced on the S4810. 7.5.1.0 Added support for IPv6 ISIS. 6.3.1.0 Introduced. To redistribute a default route (0.0.0.0/0), configure the default-information originate command. Changing or disabling a keyword in this command does not affect the state of the other command keywords. When an LSP with an internal metric is received, the Dell Networking OS considers the route cost while considering the advertised cost to reach the destination.
level-1 (OPTIONAL) Routes are independently redistributed into ISIS Level 1 routes only. level-1-2 (OPTIONAL) Routes are independently redistributed into ISIS Level 1 and Level 2 routes. level-2 (OPTIONAL) Routes are independently redistributed into ISIS as Level 2 routes only. This setting is the default. metric metricvalue (OPTIONAL) The value used for the redistributed route. Use a metric value that is consistent with the destination protocol. The range is from 0 to 16777215. The default is 0.
Usage Information BGP to IS-IS redistribution supports “match” options using route maps. You can set the metric value, level, and metric-type of redistributed routes by the redistribution command. You can “set” more advanced options using route maps.
match {external | internal} route-map map-name (OPTIONAL) The command used for OSPF to route and redistribute into other routing domains. The values are • internal • external map-name is an identifier for a configured route map. The route map should filter imported routes from the source routing protocol to the current routing protocol. If you do not specify a map-name, all routes are redistributed. If you specify a keyword, but fail to list route map tags, no routes are imported.
router isis Allows you to enable the IS-IS routing protocol and to specify an IP IS-IS process. S4820T Syntax router isis [vrf vrf-name] [tag] To disable IS-IS routing, use the no router isis [tag] command. Parameters vrf vrf-name Enter the keyword vrf followed by the name of the VRF to enable the IS-IS routing protocol and to specify an IP IS-IS process on that VRF. tag (OPTIONAL) This is a unique name for a routing process. A null tag is assumed if the tag option is not specified.
Related Commands • ip router isis — configures IS-IS routing processes for IP on interfaces and attaches an area designator to the routing process. • net — configures an IS-IS network entity title (NET) for a routing process. • is-type — assigns a type for a given area. set-overload-bit To set the overload bit in zeroth fragment of non-pseudonode LSPs on the router, configure the router.
NOTE: Enables you to configure a single system wide value that is common for both IPv4 and IPv6 address. show config Display the changes you made to the IS-IS configuration. Default values are not shown. Syntax show config Command Modes • ROUTER ISIS (for IPv4) • CONFIGURATION-ROUTER-ISIS-ADDRESS-FAMILY-IPV6 (for IPv6) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
multi-topology transition set-overload-bit spf-interval level-1 100 15 20 spf-interval level-2 120 20 25 exit-address-family show isis database Display the IS-IS link state database. S4820T Syntax Parameters show isis [vrf vrf-name] database [level-1 | level-2] [local] [detail | summary] [system-id] [lspid] vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to display IS-IS link state database corresponding to that VRF.
Usage Information Version Description 9.7(0.0) Added supported for VRF. Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.2(0.2) Introduced on the Z9000. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.1 Introduced on the S4810. The following describes the show isis database command shown in the following example. Field Description IS-IS Level-1/ Level-2 Link State Database Displays the IS-IS link state database for Level 1 or Level 2.
Example Field Description ATT This value represents the Attach bit. This value indicates that the router is a Level 1-2 router and can reach other areas. Level 1-only routers and Level 1-2 routers that have lost connection to other Level 1-2 routers use the Attach bit to find the closest Level 1-2 router. They install a default route to the closest Level 1-2 router. P This value represents the P bit. This bit is always set to zero as Dell Networking does not support area partition repair.
Metric: 10 IPv6 Metric: 10 IPv6 Metric: 10 IPv6 Metric: 20 IPv6 Metric: 10 IPv6 Metric: 20 IPv6 Hostname: ISIS (MT-IPv6) (MT-IPv6) (MT-IPv6) (MT-IPv6) 2511::/64 1033::/64 1011::/64 1511::/64 2511::/64 1033::/64 Dell#show isis database detail IS-IS Level-1 Link State Database LSPID LSP Seq Num Holdtime ATT/P/OL FTOS.00-00 * 0x00000009 941 1/0/0 NLPID: 0xCC Area Address: 49.0000.0001 LSP Checksum LSP 0x79D8 show isis graceful-restart detail Display detailed IS-IS graceful restart related settings.
Example Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.3.1.0 Introduced on the E-Series.
Example Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. Dell#show isis hostname System Id Dynamic Name Static Name *F100.E120.0013 Force10 ISIS Dell# show isis interface Display detailed IS-IS interface status and configuration information.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.2(0.2) Introduced on the Z9000. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.
Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to display adjacent router information corresponding to that VRF. level-1 (OPTIONAL) Displays information about Level 1 IS-IS neighbors. level-2 (OPTIONAL) Displays information about Level 2 IS-IS neighbors. detail (OPTIONAL) Displays detailed information about neighbors.
Example Field Description System Id The value that identifies a system in an area. Interface The interface, slot, and port in which the router was discovered. State The value providing status about the adjacency state. The range is Up and Init. Type This value displays the adjacency type (Layer 2, Layer 2 or both). Priority IS-IS priority the neighbor advertises. The neighbor with highest priority becomes the designated router for the interface. Uptime Displays the interfaces uptime.
Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.2(0.2) Introduced on the Z9000. 9.0.2.0 Introduced on the S6000. 8.3.19.
show isis traffic This command allows you to display IS-IS traffic interface information. S4820T Syntax Parameters show isis [vrf vrf-name] traffic [interface] vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to display IS-IS traffic interface information corresponding to that VRF. interface (OPTIONAL) Identifies the interface type slot/port as one of the following: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Example Item Description Level-1/Level-2 Hellos (sent/rcvd) Displays the number of Hello packets sent and received. PTP Hellos (sent/ rcvd) Displays the number of point-to-point Hellos sent and received. Level-1/Level-2 LSPs sourced (new/refresh) Displays the number of new and refreshed LSPs. Level-1/Level-2 LSPs flooded (sent/rcvd) Displays the number of flooded LSPs sent and received. Level-1/Level-2 LSPs CSNPs (sent/ rcvd) Displays the number of CSNP LSPs sent and received.
spf-interval Specify the minimum interval between shortest path first (SPF) calculations. Syntax spf-interval [level-l | level-2] interval seconds [initial_wait_interval seconds [second_wait_interval seconds]] To restore default values, use the no spf-interval [level-l | level-2] interval seconds [initial_wait_interval seconds [second_wait_interval seconds]] command.
Usage Information Version Description 7.8.1.0 Added support for multi-topology ISIS. 7.5.1.0 Added support for SPF Throttling Enhancement. This command spf-interval in CONFIG-ROUTER-ISIS-AF-IPV6 mode is used for IPv6 Multi-Topology route computation only. If using Single Topology mode, use the spf-interval command in CONFIG-ROUTER-ISIS mode for both IPv4 and IPv6 route computations. SPF throttling slows down the frequency at which route calculations are performed during network instability.
31 Link Aggregation Control Protocol (LACP) This chapter contains commands for Dell Networks’s implementation of the link aggregation control protocol (LACP) for creating dynamic link aggregation groups (LAGs) — known as “port-channels” in the Dell Networking operating software. The LACP commands in this chapter are supported by Dell Networking OS on the S4820T platform.
Related Commands Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. show lacp — displays the LACP configuration. debug lacp Debug LACP (configuration, events, and so on). S4820T Syntax debug lacp [config | events | pdu [interface-type [in | out]]] To disable LACP debugging, use the no [config | events | pdu [interface-type [in | out]]] command.
Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.
Version Description 9.7(0.0) Introduced on the S6000–ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. Usage Information This command applies to dynamic port-channel interfaces only. When applied on a static port-channel, this command has no effect. Related Commands show lacp — displays the LACP configuration.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. lacp system-priority Configure the LACP system priority. S4820T Syntax Parameters lacp system-priority priority-value priority-value Enter the port-priority value. The higher the value number, the lower the priority.
Version Description 6.2.1.1 Introduced on the E-Series. port-channel-protocol lacp Enable LACP on any LAN port. S4820T Syntax port-channel-protocol lacp To disable LACP on a LAN port, use the no port-channel-protocol lacp command. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
show lacp Display the LACP matrix. S4820T Syntax Parameters show lacp port-channel-number [sys-id | counters] port-channelnumber Enter a port-channel number. The range is from 1 to 128. sys-id (OPTIONAL) Enter the keywords sys-id and the value that identifies a system. counters (OPTIONAL) Enter the keyword counters to display the LACP counters. Defaults Without a Port Channel specified, the command clears all Port Channel counters.
OUT_OF_SYNC I-Collection enabled, J-Collection disabled, K-Distribution enabled L-Distribution disabled, M-Partner Defaulted, N-Partner Non-defaulted, O-Receiver is in expired state, P-Receiver is not in expired state Port Te 1/6 is enabled, LACP is Actor Admin: State ACEHJLMP Oper: State ACEGIKNP Partner Admin: State BDFHJLMP Oper: State BCEGIKNP Dell# Example (Sysid) enabled and mode is lacp Key 1 Priority 128 Key 1 Priority 128 Key 0 Priority 0 Key 1 Priority 128 Dell#show lacp 1 sys-id Actor System ID
32 Layer 2 This chapter describes commands to configure Layer 2 features. This chapter contains the following sections: • • • MAC Addressing Commands Virtual LAN (VLAN) Commands Far-End Failure Detection (FEFD) The VLAN commands are supported on all the S4820T platform. MAC Addressing Commands The following commands are related to configuring, managing, and viewing MAC addresses. clear mac-address-table Clear the MAC address table of all MAC address learned dynamically.
• vlan vlan-id For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. Enter the keyword vlan then a VLAN ID number from 1 to 4094. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.2(1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.
output interface output-range interface vlan vlan-id For a unicast MAC address, enter the keyword output then one of the following interfaces for which traffic is forwarded: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords portchannel then a number. The range is from 1 to 128.
Version Description pre-6.2.1.1 Introduced on the E-Series. Example (Unicast) mac-address-table static 00:01:00:00:00:01 {output Te 1/2 vlan 2} Example (Multicast) mac-address-table static 01:00:5E:01:00:01 {multicast vlan 2 output—range Te 1/2,Te 1/3} Related Commands show mac-address-table — displays the MAC address table. mac-address-table station-move threshold Change the frequency with which the MAC address station-move trap is sent after a MAC address changes in a VLAN.
mac-address-table station-move refresh-arp Ensure that address resolution protocol (ARP) refreshes the egress interface when a station move occurs due to a topology change. S4820T Syntax [no] mac-address-table station-move refresh-arp Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Defaults dynamic (OPTIONAL) Enter the keyword dynamic to allow aging of MACs even though a learning limit is configured. station-moveviolation (OPTIONAL) Enter the keywords station-move to allow a station move on learned MAC addresses. • On S-Series, the default behavior is dynamic. NOTE: “Static” means manually entered addresses, which do not age. Command Modes INTERFACE Command History This guide is platform-specific.
another interface. Enabling or disabling this option has no effect on already learned MAC addresses. After the MAC address learning limit is reached, the MAC addresses do not age out unless you add the dynamic option. To clear statistics on MAC address learning, use the clear counters command with the learning-limit parameter.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the S-Series. 7.8.1.0 Introduced on the C-Series. 7.5.1.0 Introduced on the E-Series. Usage Information This command is supported on physical interfaces, static LAGs, and LACP LAGs. Related Commands show mac learning-limit — displays details of the mac learning-limit.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810. Usage Information If you configure mac-learn-limit and the sticky MAC feature is enabled, dynamically learned MAC addresses are converted to sticky for that port. Any new MAC address that is learned also becomes sticky for that port. Related Commands show mac learning-limit — displays the details of the mac learning-limit.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the S-Series. 7.8.1.0 Introduced on the C-Series. 7.5.1.0 Introduced on the E-Series. Usage Information This command is supported on physical interfaces, static LAGs, and LACP LAGs. Related Commands show mac learning-limit — displays details of the mac learning-limit. mac learning-limit reset Reset the MAC address learning-limit error-disabled state.
show cam mac linecard (count) Display the content addressable memory (CAM) size and the portions allocated for MAC addresses and for MAC ACLs. S4820T Syntax Parameters show cam mac linecard slot port-set port-pipe count [vlan vlanid] [interface interface] linecard slot (REQUIRED) Enter the keyword linecard then a slot number to select the linecard for which to gather information.
Version Description pre-6.2.1.1 Introduced on the E-Series. show cam mac linecard (dynamic or static) Display the CAM size and the portions allocated for MAC addresses and for MAC ACLs. S4820T Syntax Parameters Command Modes Command History show cam mac linecard slot port-set port-pipe [address mac_addr | dynamic | interface interface | static | vlan vlan-id] linecard slot (REQUIRED) Enter the keyword linecard then a slot number to select the linecard for which to gather information.
Example Version Description 8.3.19.0 Introduced on the S4820T. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series.
address/mac-address, interface/interface, or vlan vlan-id. static (OPTIONAL) Enter the keyword static to display only those MAC addresses specifically configured on the switch. Optionally, you can also add one of these combinations: address/mac-address, interface/interface, or vlan vlan-id. aging-time Enter the keyword aging-time to display only aging-time information.
Usage Information Version Description 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. The following describes the show mac-address-table command shown in the following example. Column Heading Description VlanId Displays the VLAN ID number. Mac Address Displays the MAC address in nn:nn:nn:nn:nn:nn format.
Column Heading Description Type Lists whether the MAC address was manually configured (Static), learned (Dynamic), or associated with a specific port (Sticky). An (N) indicates that the specified MAC address has been learnt by a neighbor and is synced to the node. Interface Displays the interface type and slot/port information. The following abbreviations describe the interface types: State • gi — Gigabit Ethernet followed by a slot/port • po — Port Channel followed by a number.
Parameters vlan vlan-id (OPTIONAL) Enter the keyword vlan then the VLAN ID to display the MAC address assigned to the VLAN. The range is from 1 to 4094. Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.
interface interface vlan vlan-id (OPTIONAL) Enter the keyword interface then the interface type, slot and port information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. (OPTIONAL) Enter the keyword vlan then the VLAN ID to display the MAC address assigned to the VLAN. The range is from 1 to 4094.
Related Commands show mac accounting access-list — displays the MAC access list configurations and counters (if configured). show mac learning-limit Display MAC address learning limits set for various interfaces. S4820T Syntax Parameters show mac learning-limit [violate-action] [detail] [interface interface] violate-action (OPTIONAL) Enter the keywords violate-action to display the MAC learning limit violation status.
Example Version Description 7.7.1.0 Introduced on the C-Series. 7.5.1.0 Added support for the violate-action and detail options. 6.5.1.0 Added support for Port Channel.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced The no default vlan disable command is not listed in the runningconfiguration, but when the default VLAN is disabled, default-vlan disable is listed in the running-configuration. name Assign a name to the VLAN. S4820T Syntax name vlan-name To remove the name from the VLAN, use the no name command.
Usage Information To display information about a named VLAN, enter the show vlan command with the name parameter or the show interfaces description command. Related Commands interface vlan — configures a VLAN. show vlan — displays the current VLAN configurations on the switch. show config Display the current configuration of the selected VLAN. S4820T Syntax show config Command Modes INTERFACE VLAN Command History This guide is platform-specific.
show vlan Display the current VLAN configurations on the switch. S4820T Syntax Parameters show vlan [brief | id vlan-id | name vlan-name] brief (OPTIONAL) Enter the keyword brief to display the following information: • VLAN ID • VLAN name (left blank if none is configured) • Spanning Tree Group ID • MAC address aging time • IP address id vlan-id (OPTIONAL) Enter the keyword id then a number from 1 to 4094. Only information on the VLAN specified is displayed.
Usage Information Version Description 7.6.1.0 Introduced on the S-Series and revised the output to display Native VLAN. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. The following describes the show vlan command shown in the following example. Column Heading Description (Column 1 — no heading) • asterisk symbol (*) = Default VLAN • G = GVRP VLAN • P = primary VLAN C = community VLAN I = isolated VLAN • O = OpenFlow NUM Displays existing VLAN IDs.
Community, I - Isolated Q: U - Untagged, T - Tagged, O - Openflow x - Dot1x untagged, X - Dot1x tagged o - OpenFlow untagged, O - OpenFlow tagged G - GVRP tagged, M - Vlan-stack i - Internal untagged, I - Internal tagged, v - VLT untagged, V - VLT tagged NUM Status Description Q Ports * 1 Inactive 2 Active U Po1(Te 13/1) T Po20(Te 13/6), Te 13/25 T Te 13/7 3 Active T Po20(Te 13/6) T Te 13/7 U Te 13/1 4 Active U Po2(Te 13/2) T Po20(Te 13/6) T Te 13/7 5 Active T Po20(Te 13/6) T Te 13/7 U Te 13/3 6 Active U Po
42 Dell# Active U Te 13/47 Example (Brief) Dell#show vlan br VLAN Name STG MAC Aging IP Address ---- -----------------------------------1 0 1800 unassigned 2 0 1800 2.2.2.2/24 3 0 1800 3.3.3.
• For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. Defaults All interfaces in Layer 2 mode are untagged. Command Modes INTERFACE VLAN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
To remove the tracking feature from the VLAN, use the no track ip interface command. Parameters interface Enter the following keywords and slot/port or number information: • For a port channel interface, enter the keywords portchannel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
Related Commands interface vlan — configures a VLAN. tagged — specifies which interfaces in a VLAN are tagged. untagged Add a Layer 2 interface to a VLAN as an untagged interface. S4820T Syntax untagged interface To remove an untagged interface from a VLAN, use the no untagged interface command. Parameters interface Enter the following keywords and slot/port or number information: • For a port channel interface, enter the keywords portchannel then a number. The range is from 1 to 128.
Usage Information Version Description 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. Untagged interfaces can only belong to one VLAN. In the Default VLAN, you cannot use the no untagged interface command. To remove an untagged interface from all VLANs, including the Default VLAN, enter INTERFACE mode and use the no switchport command. Related Commands interface vlan — configures a VLAN. tagged — specifies which interfaces in a VLAN are tagged.
• For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
• aggressive: Change the link state to “error-disabled” when a far-end failure is detected by the software on that interface. When an interface is placed in an “errordisabled” state, you must enter the fefd reset command to reset the interface state. Range is normal or aggressive. Default is normal. Defaults Disabled. Command Modes INTERFACE Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Legacy E-Series command.
Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Legacy E-Series command. Related Commands • fefd — enables far-end failure detection. fefd mode Change the FEFD mode on an interface. S4820T Syntax fefd mode {normal | aggressive}] To return the FEFD mode to the default of normal, use the no fefd mode command.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Legacy E-Series command. Related Commands • fefd — enables far-end failure detection. fefd reset Reset all interfaces or a single interface that was in “error-disabled” mode.
Related Commands • fefd — enables far-end failure detection. fefd-global interval Configure an interval between FEFD control packets. S4820T Syntax fefd-global interval seconds To return to the default value, use the no fefd-global interval command. Parameters seconds Enter a number as the time between FEFD control packets. The range is from 3 to 300 seconds. The default is 15 seconds. Defaults 15 seconds Command Modes CONFIGURATION Command History This guide is platform-specific.
To disable FEFD globally, use the no fefd-global [mode {normal | aggressive}] command. Parameters interval seconds Enter the keyword interval followed by the number of seconds to wait between FEFD control packets. Range is from 3 to 300 seconds. Default is 15 seconds. normal (OPTIONAL) Enter the keywords mode normal to change the link state to “unknown” when a far-end failure the software detects on that interface.
• show fefd — shows the FEFD command output. show fefd View FEFD status globally or on a specific interface. S4820T Syntax Parameters show fefd [interface] interface (OPTIONAL) Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
Example Field Description State Displays the state of the interface and can be one of the following: • bi-directional (interface is up, connected and hearing neighbor’s echoes). • err-disabled (only found when FEFD mode is aggressive and when the interface has not hearing its neighbor’s echoes for three times the message interval. To reset an interface in this state, use the fefd reset command.) • unknown (only found when FEFD mode is normal.
Link Layer Discovery Protocol (LLDP) 33 The link layer discovery protocol (LLDP) advertises connectivity and management from the local station to the adjacent stations on an IEEE 802 LAN. This chapter contains the following sections: • LLPD Commands • LLDP-MED Commands LLDP facilitates multi-vendor interoperability by using standard management tools to discover and make available a physical topology for network management.
Parameters port-protocolvlan-id Enter the keywords port-protocol-vlan-id to advertise the port protocol VLAN identification TLV. port-vlan-id Enter the keywords port-vlan-id to advertise the port VLAN identification TLV. vlan-name Enter the keywords vlan-name to advertise the vlan-name TLV. This keyword is only supported on the C-Series and SSeries. Defaults Disabled. Command Modes CONFIGURATION (conf-lldp) and INTERFACE (conf-if-interface-lldp) Command History This guide is platform-specific.
Parameters max-framesize Enter the keywords max-frame-size to advertise the dot3 maximum frame size. Defaults none Command Modes CONFIGURATION (conf-lldp) and INTERFACE (conf-if-interface-lldp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON.
Defaults none Command Modes CONFIGURATION (conf-lldp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.1.(0.0) Modified to support management-address parameter. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Defaults none Command Modes INTERFACE (conf-interface-lldp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.1.(0.0) Introduced on the Z9000 and S4810. 8.3.19.0 Introduced on the S4820T.
Version Description 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. clear lldp neighbors Clear LLDP neighbor information for all interfaces or a specific interface.
debug lldp interface To display timer events, neighbor additions or deletions, and other information about incoming and outgoing packets, enable LLDP debugging. S4820T Syntax debug lldp interface {interface | all}{events | packet {brief | detail} {tx | rx | both}} To disable debugging, use the no debug lldp interface {interface | all}{events} {packet {brief | detail} {tx | rx | both}} command.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. disable Enable or disable LLDP.
Related Commands protocol lldp (Configuration) — enables LLDP globally. debug lldp interface — debugs LLDP. show lldp neighbors — displays the LLDP neighbors. hello Configure the rate at which the LLDP control packets are sent to its peer. S4820T Syntax hello seconds To revert to the default, use the no hello seconds command. Parameters seconds Enter the rate, in seconds, at which the control packets are sent to its peer. The rate is from 5 to 180 seconds. The default is 30 seconds.
mode To receive or transmit, set LLDP. S4820T Syntax mode {tx | rx} To return to the default, use the no mode {tx | rx} command. Parameters tx Enter the keyword tx to set the mode to transmit. rx Enter the keyword rx to set the mode to receive. Defaults Both transmit and receive. Command Modes CONFIGURATION (conf-lldp) and INTERFACE (conf-if-interface-lldp) Command History This guide is platform-specific.
multiplier Set the number of consecutive misses before LLDP declares the interface dead. S4820T Syntax multiplier integer To return to the default, use the no multiplier integer command. Parameters integer Enter the number of consecutive misses before the LLDP declares the interface dead. The range is from 2 to 10. Defaults 4 x hello Command Modes CONFIGURATION (conf-lldp) and INTERFACE (conf-if-interface-lldp) Command History This guide is platform-specific.
Command Modes CONFIGURATION (conf-lldp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. Before LLDP can be configured on an interface, it must be enabled globally from CONFIGURATION mode. This command places you in LLDP mode on the interface; it does not enable the protocol. When you enter the LLDP protocol in the Interface context, it overrides global configurations.
Version Description 9.0.2.0 Introduced on the S6000. 9.1.(0.0) Modified output of detail parameter to display remote management IP addresses. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series.
Example Version Description 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. Dell#show lldp statistics Total number of neighbors: 300 Last table change time : Mon Oct 02 16:00:52 2006 Number of Table Inserts : 1621 Number of Table Deletes : 200 Number of Table Drops : 0 Number of Table Age Outs : 400 Dell# show running-config lldp Display the current global LLDP configuration.
description hello 15 multiplier 3 no disable Dell# LLDP-MED Commands The following are the LLDP-MED (Media Endpoint Discovery) commands. Dell Networking OS LLDP-MED commands are an extension of the set of LLDP TLV advertisement commands. The C-Series and S-Series support all commands. The E-Series generally supports the commands. However, LLDP-MED commands are more useful on the C-Series and the S50V model of the S-Series, because they support Power over Ethernet (PoE) devices.
Parameters vlan-id Enter the VLAN ID. The range is from 1 to 4094. layer2_priority Enter the Layer 2 priority. The range is from 0 to 7. DSCP_value Enter the DSCP value. The range is from 0 to 63. priority-tagged number Enter the keywords priority-tagged followed the Layer 2 priority. The range is from 0 to 7. Defaults Unconfigured. Command Modes CONFIGURATION (conf-lldp) Command History This guide is platform-specific.
Parameters vlan-id Enter the VLAN ID. The range is from 1 to 4094. layer2_priority Enter the Layer 2 priority. The range is from 0 to 7. DSCP_value Enter the DSCP value. The range is from 0 to 63. priority-tagged number Enter the keywords priority-tagged then the Layer 2 priority. The range is from 0 to 7. Defaults unconfigured. Command Modes CONFIGURATION (conf-lldp) Command History This guide is platform-specific.
Parameters coordinatebased value Enter the keywords coordinate-based then the coordinated based location in hexadecimal value of 16 bytes. civic-based value Enter the keywords civic-based then the civic based location in hexadecimal format. The range is from 6 to 255 bytes. ecs-elin value Enter the keywords ecs-elin then the Emergency Call Service (ecs) Emergency Location Identification Number (elin) numeric location string. The range is from 10 to 25 characters. Defaults unconfigured.
advertise med power-via-mdi To advertise the Extended Power via MDI TLV, configure the system. S4820T Syntax advertise med power-via-mdi To return to the default, use the no advertise med power-via-mdi command. Defaults unconfigured. Command Modes CONFIGURATION (conf-lldp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
To return to the default, use the no advertise med softphone-voice {vlan-id layer2_priority DSCP_value} | {priority-tagged number} command. Parameters vlan-id Enter the VLAN ID. The range is from 1 to 4094. layer2_priority Enter the Layer 2 priority (C-Series and E-Series only). The range is from 0 to 7. DSCP_value Enter the DSCP value (C-Series and E-Series only). The range is from 0 to 63. priority-tagged number Enter the keywords priority-tagged then the Layer 2 priority.
To return to the default, use the no advertise med streaming-video {vlan-id layer2_priority DSCP_value} | {priority-tagged number} command. Parameters vlan-id Enter the VLAN ID. The range is from 1 to 4094. layer2_priority Enter the Layer 2 priority (C-Series and E-Series only). The range is from 0 to 7. DSCP_value Enter the DSCP value (C-Series and E-Series only). The range is from 0 to 63. priority-tagged number Enter the keywords priority-tagged then the Layer 2 priority.
To return to the default, use the no advertise med video-conferencing {vlan-id layer2_priority DSCP_value} | {priority-tagged number} command. Parameters vlan-id Enter the VLAN ID. The range is from 1 to 4094. layer2_priority Enter the Layer 2 priority (C-Series and E-Series only). The range is from 0 to 7. DSCP_value Enter the DSCP value (C-Series and E-Series only). The range is from 0 to 63. priority-tagged number Enter the keywords priority-tagged then the Layer 2 priority.
To return to the default, use the no advertise med video-signaling {vlan-id layer2_priority DSCP_value} | {priority-tagged number} command. Parameters vlan-id Enter the VLAN ID. The range is from 1 to 4094. layer2_priority Enter the Layer 2 priority (C-Series and E-Series only). The range is from 0 to 7. DSCP_value Enter the DSCP value (C-Series and E-Series only). The range is from 0 to 63. priority-tagged number Enter the keywords priority-tagged then the Layer 2 priority.
To return to the default, use the no advertise med voice {vlan-id layer2_priority DSCP_value} | {priority-tagged number} command. Parameters vlan-id Enter the VLAN ID. The range is from 1 to 4094. layer2_priority Enter the Layer 2 priority (C-Series and E-Series only). The range is from 0 to 7. DSCP_value Enter the DSCP value (C-Series and E-Series only). The range is from 0 to 63. priority-tagged number Enter the keywords priority-tagged then the Layer 2 priority. The range is from 0 to 7.
To return to the default, use the no advertise med voice-signaling {vlan-id layer2_priority DSCP_value} | {priority-tagged number} command. Parameters vlan-id Enter the VLAN ID. The range is from 1 to 4094. layer2_priority Enter the Layer 2 priority (C-Series and E-Series only). The range is from 0 to 7. DSCP_value Enter the DSCP value (C-Series and E-Series only). The range is from 0 to 63. priority-tagged number Enter the keywords priority-tagged then the Layer 2 priority.
Microsoft Network Load Balancing 34 Network Load Balancing (NLB) is a clustering functionality that is implemented by Microsoft on Windows 2000 Server and Windows Server 2003 operating systems. Microsoft NLB clustering allows multiple servers running Microsoft Windows to be represented by one MAC and one IP address to provide transparent failover and load-balancing.
Command Modes Command History CONFIGURATION Version 9.3(0.0) Added support for association of an IP address with multicast MAC address on the S4810, S4820T, S6000, and Z9000 platforms. Usage Information For multicast mode of NLB, to associate an IP address with a multicast MAC address in the switch, use address resolution protocol (ARP) by entering the arp ip-address multicast-mac-address command in Global configuration mode.
output-range interface vlan vlan-id • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
Version Description 9.3(0.0) Introduced on the S4810, S4820T, S6000, Z9000, and MXL platforms. Default Disabled Usage Information By default this command is disabled. There might be some ARP table entries which are resolved through ARP packets which had Ethernet MAC SA different from MAC information inside the ARP packet. This unicast data traffic flooding occurs only for those packets which use these ARP entries.
Multicast Source Discovery Protocol (MSDP) 35 Multicast source discovery protocol (MSDP) connects multiple PIM Sparse-Mode (PIM-SM) domains together. MSDP peers connect using TCP port 639. Peers send keepalives every 60 seconds. A peer connection is reset after 75 seconds if no MSDP packets are received. MSDP connections are parallel with MBGP connections. The Dell Networking operating system supports MSDP commands on the S4820T platform.
Version Description 8.3.7.1 Introduced on the S4810. 6.2.1.1 Introduced clear ip msdp sa-cache Clears the entire source-active cache, the source-active entries of a particular multicast group, rejected, or local source-active entries. S4820T Syntax Parameters clear ip msdp sa-cache [group-address | rejected-sa | local] group-address Enter the group IP address in dotted decimal format (A.B.C.D.).
Version Description 7.7.1.0 Added the rejected-sa option. 6.2.1.1 Introduced clear ip msdp statistic Clears the entire source-active cache, the source-active entries of a particular multicast group, rejected, or local source-active entries. S4820T Syntax Parameters clear ip msdp statistic peer peer-address peer Enter the keyword peer to clear the MSDP peer entries. peer-address Enter the IP address of the MSDP peer.
debug ip msdp Turn on MSDP debugging. S4820T Syntax debug ip msdp {event peer address | packet peer address | pim} To turn debugging off, use the no debug ip msdp {event peer address | packet peer address | pim} command. Parameters event peer address Enter the keyword event then the peer address in a dotted decimal format (A.B.C.D.). packet peer address Enter the keyword packet then the peer address in a dotted decimal format (A.B.C.D.). pim Enter the keyword pim to debug advertisement from PIM.
ip msdp cache-rejected-sa Enable an MSDP cache for the rejected source-active entries. S4820T Syntax ip msdp cache-rejected-sa {number} To clear the MSDP rejected source-active entries, use the no ip msdp cacherejected-sa {number} command then the ip msdp cache-rejected-sa {number} command. Parameters number Enter the number of rejected SA entries to cache. The range is from 0 to 32766. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific.
ip msdp default-peer Define a default peer from which to accept all source-active (SA) messages. S4820T Syntax ip msdp default-peer peer address [list name] To remove the default peer, use the no ip msdp default-peer {peer address} list name command. Parameters peer address Enter the peer address in a dotted decimal format (A.B.C.D.) list name Enter the keywords list name and specify a standard access list that contains the RP address that should be treated as the default peer.
ip msdp log-adjacency-changes Enable logging of MSDP adjacency changes. S4820T Syntax ip msdp log-adjacency-changes To disable logging, use the no ip msdp log-adjacency-changes command. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
peer address Enter the peer address in a dotted decimal format (A.B.C.D.). Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
• For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords portchannel then a number. The range is from 1 to 128. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
Parameters peer address Enter the peer address in a dotted decimal format (A.B.C.D.). connectsource interface Enter the keywords connect-source then one of the interfaces and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383.
Usage Information The connect-source option is used to supply a source IP address for the TCP connection. When an interface is specified using the connect-source option, the primary configured address on the interface is used. If the total number of SA messages received from the peer is already larger than the limit when this command is applied, those SA messages continue to be accepted. To enforce the limit in such situation, use the clear ip msdp peer command to reset the peer.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced Modifications to the ACL do not have an immediate effect on the sa-cache. To apply the redistribute filter to entries already present in the SA cache, use the clear ip msdp sa-cache local command. ip msdp sa-filter Permit or deny MSDP source active (SA) messages based on multicast source and/or group from the specified peer.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the E-Series. ip msdp sa-limit Configure the upper limit of source-active (SA) entries in SA-cache. S4820T Syntax ip msdp sa-limit number To return to the default, use the no ip msdp sa-limit number command. Parameters number Enter the maximum number of SA entries in SA-cache. The range is from 1 to 500000.
limit, the subsequent SA messages are dropped (even if they pass RPF checking and policy checking). If the total number of SA messages is already larger than the limit when this command is applied, those SA messages that are already in Dell Networking OS continue to be accepted. To enforce the limit in such situation, use the clear ip msdp sa-cache command. Related Commands ip msdp peer — configures the MSDP peer. clear ip msdp peer — clears the MSDP peer. show ip msdp — displays the MSDP information.
ip multicast-msdp Enable MSDP. S4820T Syntax ip multicast-msdp To exit MSDP, use the no ip multicast-msdp command. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Defaults Not configured. Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
show ip msdp sa-cache rejected-sa Display the rejected SAs in the SA cache. S4820T Syntax show ip msdp sa-cache rejected-sa Defaults none Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.
00:00:13 225.1.2.18 10.1.1.4 00:00:13 225.1.2.19 10.1.1.3 1192 110.1.1.1 13.1.1.2 Rpf-Fail 110.1.1.1 13.1.1.
36 Multiple Spanning Tree Protocol (MSTP) Multiple spanning tree protocol (MSTP), as implemented by the Dell Networking operating system, conforms to IEEE 802.1s. This command supports the Dell Networking S4820T platform. debug spanning-tree mstp Enable debugging of the multiple spanning tree protocol and view information on the protocol.
events (OPTIONAL) Enter the keyword events to debug MSTP events. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series.
Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.5.1.0 Introduced. max-age — changes the wait time before MSTP refreshes protocol configuration information. hello-time — changes the time interval between bridge protocol data units (BPDUs).
Related Commands Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.5.1.0 Introduced. forward-delay — the amount of time the interface waits in the Blocking State and the Learning State before transitioning to the Forwarding State.
Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.5.1.0 Introduced. forward-delay — the amount of time the interface waits in the Blocking State and the Learning State before transitioning to the Forwarding State.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.1 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.5.1.0 Introduced. The max-hops command is a configuration command that applies to both the IST and all MST instances in the MSTP region. The BPDUs sent out by the root switch set the remaining-hops parameter to the configured value of max-hops.
Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.5.1.0 Introduced. Usage Information For two MSTP switches to be within the same MSTP region, the switches must share the same region name (including matching case). Related Commands msti — maps the VLAN(s) to an MST instance.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. MSTP is not enabled when you enter MULTIPLE SPANNING TREE mode. To enable MSTP globally on the switch, enter the no disable command while in MULTIPLE SPANNING TREE mode.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. Usage Information For two MSTP switches to be within the same MST region, the switches must share the same revision number. Related Commands msti — maps the VLAN(s) to an MST instance.
Example Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.5.1.0 Introduced on the E-Series. Dell(conf-mstp)#show config ! protocol spanning-tree mstp no disable name CustomerSvc revision 2 MSTI 10 VLAN 101-105 max-hops 5 Dell(conf-mstp)# show spanning-tree mst configuration View the multiple spanning tree configuration.
Usage Information Enable the multiple spanning tree protocol prior to using this command. Example Dell#show spanning-tree mst configuration MST region name: CustomerSvc Revision: 2 MSTI VID 10 101-105 Dell# show spanning-tree msti View the multiple spanning tree instance. S4820T Syntax Parameters show spanning-tree msti [instance-number [brief]] [guard] instancenumber (Optional) Enter the multiple spanning tree instance number. The range is from 0 to 63.
Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.4.1.0 Expanded to display the port error disable state (EDS) loopback BPDU inconsistency causes. Usage Information Enable the multiple spanning tree protocol prior to using this command. Example Dell#show spanning-tree msti 10 MSTI 10 VLANs mapped 101-105 Bridge Identifier has priority 32768, Address 0001.e802.
hops 20 CIST regional root ID Priority 32768, Address 0001.e801.6aa8 CIST external path cost 0 Interface Designated Name PortID Prio Cost Sts Cost Bridge ID PortID ---------------------------------------------------------Te 1/1 128.257 128 20000 EDS 0 32768 0001.e801.6aa8 128.257 Interface Name Role PortID Prio Cost Sts Cost Link-type Edge Boundary ---------------------------------------------------------Te 1/1 ErrDis 128.
Te 1/2 Te 1/3 5 5 FWD EDS(Shut) Loopguard Bpduguard spanning-tree Enable the multiple spanning tree protocol on the interface. S4820T Syntax spanning-tree To disable the multiple spanning tree protocol on the interface, use the no spanning-tree command. Parameters spanning-tree Enter the keywords spanning-tree to enable the MSTP on the interface. Defaults Enable. Command Modes INTERFACE Command History This guide is platform-specific.
spanning-tree msti Configure multiple spanning tree instance cost and priority for an interface. S4820T Syntax Parameters spanning-tree msti instance {cost cost | priority priority} msti instance Enter the keyword msti and the MST instance number. The range is from zero (0) to 63. cost cost (OPTIONAL) Enter the keyword cost then the port cost value. The range is from 1 to 200000.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.5.1.0 Introduced on the E-Series. spanning-tree mstp edge-port Configures the interface as an MST edge port and optionally a Bridge Protocol Data Unit (BPDU) guard.
Usage Information Version Description 8.3.7.1 Introduced on the S4810. 8.2.1.0 Introduced the hardware shutdown-on-violation option. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.5.1.0 Introduced on the E-Series. On an MSTP switch, a port configured as an edge port immediately transitions to the Forwarding state. Only configure ports connected to end-hosts as edge ports. Consider an edge port similar to a port with spanning-tree portfast enabled.
Usage Information 1212 Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.5.1.0 Introduced By default, Dell Networking OS implements an optimized flush mechanism for MSTP. This mechanism helps in flushing the MAC addresses only when necessary (and less often) allowing for faster convergence during topology changes.
37 Multicast The multicast commands are supported by Dell Networking operating system (OS) on all S4820T platform. This chapter contains the following sections: • IPv4 Multicast Commands IPv4 Multicast Commands The following section contains the IPv4 multicast commands. clear ip mroute Clear learned multicast routes on the multicast forwarding table. To clear the protocol-independent multicast (PIM) tree information base, use the clear ip pim tib command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.2(1.0) Introduced on the Z9500. 9.2.(0.0) Added support for keyword snooping on the Z9000, S4810, and S4820T. 9.0.2.0 Introduced on the S6000. 8.3.19.
mask Enter the mask in slash prefix formation ( /x ) or in dotted decimal format. null 0 (OPTIONAL) Enter the keyword null then zero (0). [protocol [process-id | tag] ip-address] (OPTIONAL) Enter one of the routing protocols: • Enter the BGP as-number then the IP address in dotted decimal format of the reverse path forwarding (RPF) neighbor. The range is from 1 to 65535. • Enter the OSPF process identification number then the IP address in dotted decimal format of the RPF neighbor.
ip multicast-limit To limit the number of multicast entries on the system, use this feature. S4820T Syntax Parameters ip multicast-limit [vrf vrf-name] limit vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to limit the number of multicast on the VRF. limit Enter the desired maximum number of multicast entries on the system. The S-Series range is from 1 to 16000. Defaults The S-Series default is 4000.
ip multicast-routing Enable IP multicast forwarding. S4820T Syntax ip multicast-routing [vrf vrf-name] To disable multicast forwarding, use the no ip multicast-routing [vrf vrf-name] command. Defaults Parameters Disabled. vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to enable IP multicast forwarding on that VRF. Command Modes CONFIGURATION Command History This guide is platform-specific.
show ip mroute View the multicast routing table. Syntax Parameters show ip mroute [vrf vrf-name] [static | group-address [sourceaddress] | count | snooping [vlan vlan-idIntroduced on the S6000-ON.] [group-address [source-address]] | summary | vlt [group-address [source-address] | count] vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure this setting on that VRF. NOTE: Applies to specific VRF if input is provided, else applies to Default VRF.
Command Modes Command History • • EXEC EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.2.(0.
TenGigabitEthernet 4/13 TenGigabitEthernet 4/20 Example (VLT) Dell#show ip mroute vlt IP Multicast Routing Table Flags: S – Synced (*, 225.1.1.1), uptime 00:39:33 flags: S Incoming interface: Vlan 10 Spanned outgoing interface list: Vlan 20 (S) Vlan 30 (50.1.1.2, 225.1.1.1), uptime 00:39:33 flags: S Incoming interface: Vlan 10 Spanned outgoing interface list: Vlan 20 (S) Usage Information Example The following describes the show ip mroute command shown in the following example.
show ip rpf View reverse path forwarding. S4820T Syntax show ip rpf Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Neighbor Discovery Protocol (NDP) 38 The neighbor discovery protocol for IPv6 is defined in RFC 2461 as part of the Stateless Address Autoconfiguration protocol. It replaces the Address Resolution Protocol used with IPv4.
NOTE: If you do not specify this option, the neighbors in the default VRF are cleared. ipv6-address Enter the IPv6 address of the neighbor in the x:x:x:x::x format to remove a specific IPv6 neighbor. NOTE: The :: notation specifies successive hexadecimal fields of zero.
ipv6 neighbor Configure a static entry in the IPv6 neighbor discovery. S4820T Syntax ipv6 neighbor [vrf vrf-name] {ipv6-address} {interface interface} {hardware_address} To remove a static IPv6 entry from the IPv6 neighbor discovery, use the no ipv6 neighbor [vrf vrf-name] {ipv6-address} {interface interface} command. Parameters vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to install IPv6 routes in that VRF.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.1 Introduced on the S4810. show ipv6 neighbors Display IPv6 discovery information. Entering the command without options shows all IPv6 neighbor addresses stored on the control processor (CP).
Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000–ON. 9.2(1.0) Introduced on the Z9500. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
• Host mode — When a policy with device role as host is applied on an interface, all the RA packets are dropped without validation. You can also configure the host mode policy with VLAN option to drop the RA packets on that specific VLAN and port. • Router mode — When a policy with device role as router is applied on an interface, all the RA packets are validated based on the configuration information in the policy.
Parameters host Enter the keyword host to set the device-role as host. router Enter the keyword router to set the device-role as router. Defaults none Command Modes POLICY LIST CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.
Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, and Z9000 switches. • ipv6 nd ra-guard enable—Allows you to configure the RA guard related commands. • ipv6 nd raguard policy policy-name — Defines the RA guard policy name and enter the RA guard policy configuration mode. ipv6 nd ra-guard attach-policy Apply the IPv6 RA guard to a specific interface.
Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, and Z9000 switches.
Parameters on Enter the keyword on to set the managed-config-flag value as ON. off Enter the keyword off to set the managed-config flag value as OFF. Defaults none Command Modes POLICY LIST CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.
Command Modes POLICY LIST CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, and Z9000 switches.
• ipv6 nd raguard policy policy-name — Defines the RA guard policy name and enter the RA guard policy configuration mode. other-config-flag Enable the verification of the advertised other configuration parameter. If this command is not configured, the verification process is bypassed. Syntax other-config-flag {on | off} To reset the other configuration parameter, use the no other-config-flag {on | off} command. Parameters on Enter the keyword on to set the other-config-flag value as ON.
Parameters value Enter the advertised reachability time in milliseconds. The range is from 0 to 3,600,000 milliseconds. Defaults none Command Modes POLICY LIST CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON.
Related Commands Version Description 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, and Z9000 switches. ipv6 nd raguard policy policy-name — Defines the router advertisement (RA) guard policy name and enter the RA guard policy configuration mode. router-lifetime Set the router lifetime. Syntax Parameters router—lifetime value value Enter the router lifetime in seconds. The range is from 0 to 9,000 seconds.
Parameters high Enter the keyword high to set the DRP value as high. low Enter the keyword low to set the DRP value as low. medium Enter the keyword medium to set the DRP value as medium. Defaults none Command Modes POLICY LIST CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
hop-limit maximum 251 mtu 1350 other-config-flag on reachable-time 540 retrans-timer 101 router-preference maximum medium trusted-port Dell(conf-ra_guard_policy_list)# Related Commands • ipv6 nd ra-guard enable — Allows you to configure the RA guard related commands. • ipv6 nd ra-guard policy — Defines the RA guard policy name and enter the RA guard policy list configuration mode. • device-role — Specifies the role of the device attached to the port.
Example Dell#show ipv6 nd ra-guard policy test ipv6 nd ra-guard policy test device-role router hop-limit maximum 1 match ra ipv6-access-list access other-config-flag on router-preference maximum medium trusted-port Interfaces : Te 1/1 Dell# Related Commands • ipv6 nd ra-guard enable — Allows you to configure the RA guard related commands. • ipv6 nd ra-guard policy — Defines the RA guard policy name and enter the RA guard policy list configuration mode.
Usage Information Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, and Z9000 switches. Use this command to disable all the RA guard policies. • ipv6 nd ra-guard enable — Allows you to configure the RA guard related commands. • ipv6 nd raguard policy policy-name — Defines the router advertisement (RA) guard policy name and enter the RA guard policy configuration mode.
39 Object Tracking Object Tracking supports IPv4 and IPv6, and is available on the Dell Networking, C-Series, E-Series, SSeries, and S4810 platforms. Object tracking allows you to define objects of interest, monitor their state, and report to a client when a change in an object’s state occurs.
Command Modes Command History Example • EXEC • EXEC Privilege Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced. Dell#debug track all 04:35:04: %RPM0-P:RP2 %OTM-5-STATE: track 6 - Interface TenGigabitEthernet 1/2 line-protocol DOWN 04:35:04: %RPM0-P:RP2 %OTM-5-NOTIF: VRRP notification: resource ID 6 DOWN delay Configure the time delay used before communicating a change in the status of a tracked object to clients.
If the state of an object changes back to its former UP/DOWN state before the timer expires, the timer is cancelled and the client is not notified. For example, if the DOWN timer is running when an interface goes down and comes back up, the DOWN timer is cancelled and the client is not notified of the event. If the timer expires and an object’s state has changed, a notification is sent to the client.
• track ip route reachability – configures object tracking on the reachability of an IPv4 route. show running-config track Display the current configuration of tracked objects. Syntax Parameters Command Modes Command History Example show running-config track [object-id] object-id (OPTIONAL) Display information on the specified tracked object. The range is 1 to 500. EXEC Privilege Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced.
• track ip route metric threshold – configures object tracking on the threshold of an IPv4 route metric. • track ip route reachability – configures object tracking on the reachability of an IPv4 route. show track Display information about tracked objects, including configuration, current tracked state (UP or DOWN), and the clients which are tracking an object.
Example Output Description Interface type slot/port, IP route ip-address, IPv6 route ipv6address Displays the interface type and slot/port number or address of the IPv4/IPv6 route that is being tracked. object is Up/ Down Up/Down state of tracked object; for example, IPv4 interface, reachability or metric threshold of an IP route. number changes, last change time Number of times that the state of the tracked object has changed and the time since the last change in hours:minutes:seconds.
Example (Brief) Related Commands Dell>show track brief ResId Resource Parameter State LastChange 1 IP route reachability 10.16.0.0/16 Up 00:01:08 2 Interface line-protocol Ethernet0/2 Down 00:05:00 3 Interface ip routing VLAN100 Up 01:10:05 • show running-config track – displays configuration information about tracked objects. • track interface ip routing – configures object tracking on the routing status of an IPv4 Layer 3 interface.
Usage Information Use this command to configure the UP and/or DOWN threshold for the scaled metric of a tracked IPv4 or IPv6 route. Determine the UP/DOWN state of a tracked route by the threshold for the current value of the route metric in the routing table. To provide a common tracking interface for different clients, route metrics are scaled in the range 0 to 255, where 0 is connected and 255 is inaccessible.
Defaults none Command Modes CONFIGURATION Command History Usage Information Related Commands • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords portchannel then a number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced.
Defaults none Command Modes CONFIGURATION Command History Usage Information • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords portchannel then a number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced.
Defaults none Command Modes CONFIGURATION Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced. Use this command to create an object that tracks the UP and/or DOWN threshold of an IPv4 route metric. In order for a route’s metric to be tracked, the route must appear as an entry in the routing table.
track ip route reachability Configure object tracking on the reachability of an IPv4 route. Syntax track object-id ip route ip-address/prefix-len reachability [vrf vrf-name] To return to the default setting, use the no track object-id command. Parameters object-id Enter the ID number of the tracked object. The range is 1 to 500. ip-address/ prefix-len Enter an IPv4 address in dotted decimal format. The valid IPv4 prefix lengths are from /0 to /32.
Related Commands • show track – displays information about tracked objects, including configuration, current state, and clients which track the object. • track ip route metric threshold – configures object tracking on the threshold of an IPv4 route metric. track resolution ip route Configure the protocol-specific resolution value used to scale an IPv4 route metric.
Related Commands • For OSPF, you can set the resolution in the range 1 to 1592, where the default is 1. • The resolution value used to map static routes is not configurable. By default, Dell Networking OS assigns a metric of 0 to static routes. • The resolution value used to map RIP routes is not configurable. The RIP hopcount is automatically multiplied by 16 to scale it. For example, a RIP metric of 16 (unreachable) scales to 256, which considers the route to be DOWN.
Usage Information Example Version Description 8.4.1.0 Introduced. The following describes the show track ipv6 route command shown in the Example below. Output Description Track object-id Displays the number of the tracked object. Interface type slot/port, IP route ip-address, IPv6 route ipv6address Displays the interface type and slot/port number or address of the IPv4/IPv6 route that is being tracked.
Example (Brief) Ouput Description State Up or Down state of the tracked object. Last Change Time since the last change in the state of the tracked object. Dell#show track ipv6 route brief ResId Resource Parameter State LastChange 2 IPv6 route metric threshold 2040::/64 Up 00:02:36 3 IPv6 route reachability 2050::/64 Up 00:02:36 Related Commands • show running-config track – displays configuration information about tracked objects.
Command Modes Command History Usage Information Related Commands CONFIGURATION Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced. Use this command to create an object that tracks the routing state of an IPv6 Layer 3 interface: • The status of the IPv6 interface is UP only if the Layer 2 status of the interface is UP and the interface has a valid IP address.
Usage Information Use this command to create an object that tracks the UP and/or DOWN threshold of an IPv6 route metric. In order for a route’s metric to be tracked, the route must appear as an entry in the routing table. A tracked IPv6 route is considered to match an entry in the routing table only if the exact IPv6 address and prefix length match a table entry. For example, when configured as a tracked route, 3333:100:200:300:400::/80 does not match routing table entry 3333:100:200:300::/64.
ipv6-address/ prefix-len Defaults none Command Modes CONFIGURATION Command History Usage Information Enter an IPv6 address in X:X:X:X::X format. The valid IPv6 prefix lengths are from /0 to / 128. Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced. Use this command to create an object that tracks the reachability of an IPv6 route.
Parameters object-id Enter the ID number of the tracked object. Use the range to 1 to 500. isis resolutionvalue Enter the resolution used to convert the metric in the routing table for ISIS routes to a scaled metric. ospf resolutionvalue Enter the resolution used to convert the metric in the routing table for OSPF routes to a scaled metric. Defaults none Command Modes CONFIGURATION Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.
Open Shortest Path First (OSPFv2 and OSPFv3) 40 Open Shortest Path First version 2 for IPv4 is supported on platform. OSPF is an Interior Gateway Protocol (IGP), which means that it distributes routing information between routers in a single Autonomous System (AS). OSPF is also a link-state protocol in which all routers contain forwarding tables derived from information about their links to their neighbors.
cost Specifies the stub area’s advertised external route metric. The range is from zero (0) to 65535. Defaults cost = 1; no areas are configured. Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
defaultinformationoriginate (OPTIONAL) Allows external routing information to be imported into the NSSA by using Type 7 default. no-summary (OPTIONAL) Specify that no summary LSAs should be sent into the NSSA. Defaults Not configured. Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
not-advertise (OPTIONAL) Enter the keywords not-advertise to set the status to DoNotAdvertise (that is, the Type 3 summary-LSA is suppressed and the component networks remain hidden from other areas.) Defaults Not configured. Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
no-summary (OPTIONAL) Enter the keywords no-summary to prevent the ABR from sending summary Link State Advertisements (LSAs) into the stub area. Defaults Disabled. Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.
Defaults 100 megabits per second. Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for the Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. clear ip ospf statistics Clear the packet statistics in interfaces and neighbors.
neighbor router-id (OPTIONAL) Enter the keyword neighbor then the neighbor’s router-id in dotted decimal format (A.B.C.D.). Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
event (OPTIONAL) Enter the keyword event to debug only OSPF event information. packet (OPTIONAL) Enter the keyword packet to debug only OSPF packet information. spf (OPTIONAL) Enter the keyword spf to display the Shortest Path First information. database-timer rate-limit (OPTIONAL) Enter the keywords database-timer ratelimit to display the LSA throttling timer information. This applies to the S4810 platform only. Command Modes EXEC Privilege Command History This guide is platform-specific.
Field Description • 2 - database description • 3 - link state request • 4 - link state update • 5 - link state acknowledgement l: Displays the packet length. rid: Displays the OSPF router ID. aid: Displays the Autonomous System ID. chk: Displays the OSPF checksum. aut: States if OSPF authentication is configured.
Example Field Description di: Displays the amount of time configured for the DEAD interval. dr: Displays the IP address of the designated router. bdr: Displays the IP address of the Border Area Router. Dell#debug ip ospf 1 packet OSPF process 90, packet debugging is on Dell# 08:14:24 : OSPF(100:00): Xmt. v:2 t:1(HELLO) l:44 rid:192.1.1.1 aid:0.0.0.1 chk:0xa098 aut:0 auk: keyid:0 to:Te 4/3 dst: 224.0.0.5 netmask:255.255.255.0 pri:1 N-, MC-, E+, T-, hi:10 di:40 dr:90.1.1.1 bdr:0.0.0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for the Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. description Add a description about the selected OSPF configuration.
Related Commands Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. show ip ospf asbr — displays the VLAN configuration. distance Define an administrative distance for particular routes to a specific IP address. S4820T Syntax distance weight [ip-address mask access-list-name] To delete the settings, use the no distance weight [ip-address mask access-list-name] command.
Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for the Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. distance ospf Configure an OSPF distance metric for different types of routes. S4820T Syntax distance ospf [external dist3] [inter-area dist2] [intra-area dist1] To delete these settings, use the no distance ospf command.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for the Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.1 Introduced on the E-Series. To specify a distance for routes learned from other routing domains, use the redistribute command. distribute-list in Apply a filter to incoming routing updates from OSPF to the routing table.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
NOTE: BGP and ISIS routes are not available on the CSeries. BGP, ISIS, and RIP routes are not available on the S-Series. rip (OPTIONAL) Enter the keyword rip to specify that RIP routes are distributed. NOTE: BGP and ISIS routes are not available on the CSeries. BGP, ISIS, and RIP routes are not available on the S-Series. static (OPTIONAL) Enter the keyword static to specify that only manually configured routes are distributed. Defaults Not configured.
enable inverse-mask By default, Dell Networking Operating System (OS) allows you to input the OSPF network command with a net-mask. This command provides a choice between inverse-mask or net-mask (the default). S4820T Syntax enable inverse mask To return to the default net-mask, use the no enable inverse mask command. Defaults net-mask Command Modes CONFIGURATION Command History This guide is platform-specific.
Defaults none. Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Defaults Not Configured Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810. 7.8.1.0 Restart role enabled on the S-Series (Both Helper and Restart roles now supported on S-Series). Added support for Multi-Process OSPF. 7.7.1.0 Added Helper-Role support on the S-Series. 7.5.1.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. graceful-restart role Specify the role for your OSPF router during graceful restart.
Version Description 7.8.1.0 Added support for Multi-Process OSPF. Added Restart and Helper roles support on the S-Series. 7.7.1.0 Added Helper-Role support on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. ip ospf auth-change-wait-time OSPF provides a grace period while OSPF changes its interface authentication type. During the grace period, OSPF sends out packets with new and old authentication scheme until the grace period expires.
ip ospf authentication-key Enable authentication and set an authentication key on OSPF traffic on an interface. S4820T Syntax ip ospf authentication-key [encryption-type] key To delete an authentication key, use the no ip ospf authentication-key command. Parameters encryptiontype (OPTIONAL) Enter 7 to encrypt the key. key Enter an eight-character string. Strings longer than eight characters are truncated. Defaults Not configured.
ip ospf cost Change the cost associated with the OSPF traffic on an interface. S4820T Syntax ip ospf cost cost To return to default value, use the no ip ospf cost command. Parameters cost Enter a number as the cost. The range is from 1 to 65535. Defaults The default cost is based on the reference bandwidth. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
ip ospf dead-interval Set the time interval since the last hello-packet was received from a router. After the interval elapses, the neighboring routers declare the router dead. S4820T Syntax ip ospf dead-interval seconds To return to the default values, use the no ip ospf dead-interval command. Parameters seconds Enter the number of seconds for the interval. The range is from 1 to 65535. The default is 40 seconds.
ip ospf hello-interval Specify the time interval between the hello packets sent on the interface. S4820T Syntax ip ospf hello-interval seconds To return to the default value, use the no ip ospf hello-interval command. Parameters seconds Enter the number of seconds for the interval. The range is from 1 to 65535. The default is 10 seconds. Defaults 10 seconds Command Modes INTERFACE Command History This guide is platform-specific.
ip ospf message-digest-key Enable OSPF MD5 authentication and send an OSPF message digest key on the interface. S4820T Syntax ip ospf message-digest-key keyid md5 key To delete a key, use the no ip ospf message-digest-key keyid command. Parameters keyid Enter a number as the key ID. The range is from 1 to 255. key Enter a continuous character string as the password. Defaults No MD5 authentication is configured. Command Modes INTERFACE Command History This guide is platform-specific.
After the reply is received and the new key is authenticated, delete the old key. Dell recommends keeping only one key per interface. NOTE: The MD5 secret is stored as plain text in the configuration file with service password encryption. Write down or otherwise record the key. You cannot learn the key once it is configured. Use caution when changing the key. ip ospf mtu-ignore Disable OSPF MTU mismatch detection upon receipt of database description (DBD) packets.
To return to the default, use the no ip ospf network command. Parameters broadcast Enter the keyword broadcast to designate the interface as part of a broadcast network. point-to-point Enter the keywords point-to-point to designate the interface as part of a point-to-point network. Defaults Broadcast. Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. log-adjacency-changes To send a Syslog message about changes in the OSPF adjacency state, set Dell Networking OS.
maximum-paths Enable the software to forward packets over multiple paths. S4820T Syntax maximum-paths number To disable packet forwarding over multiple paths, use the no maximum-paths command. Parameters number Specify the number of paths. The range for OSPFv2 is from 1 to 64. The default for OSPFv2 is 4 paths. The range for OSPFv3 is from 1 to 64. The default for OSPFv3 is 8 paths. Defaults 4 Command Modes ROUTER OSPF for OSPFv2 Command History This guide is platform-specific.
network area Define which interfaces run OSPF and the OSPF area for those interfaces. S4820T Syntax network ip-address mask area area-id To disable an OSPF area, use the no network ip-address mask area areaid command. Parameters ip-address Specify a primary or secondary address in dotted decimal format. The primary address is required before adding the secondary address. mask Enter a network mask in /prefix format.
Usage Information To enable OSPF on an interface, the network area command must include, in its range of addresses, the primary IP address of an interface. NOTE: An interface can be attached only to a single OSPF area. If you delete all the network area commands for Area 0, the show ip ospf command output does not list Area 0. passive-interface Suppress both receiving and sending routing updates on an interface.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Modified to include the keyword default. pre- 6.1.1.1 Introduced on the E-Series.
• If passive-interface default is specified, then save no passiveinterface interface into the running configuration. No passive-interface default • Clear everything and revert to the default behavior. • All previously marked passive interfaces are removed. • May update ABR status. On configuring suppression using the passive-interface command, the state of the OSPF neighbor does not change to INIT; instead, the state of the OSPF neighbor changes to DOWN after the dead-timer expires.
tag tag-value (OPTIONAL) Enter the keyword tag then a number. The range is from 0 to 4294967295. Defaults Not configured. Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Parameters as number Enter the autonomous system number. The range is from 1 to 65535. metric metricvalue (OPTIONAL) Enter the keyword metric then the metricvalue number. The range is from 0 to16777214. metric-type type-value (OPTIONAL) Enter the keywords metric-type then one of the following: • 1 = for OSPF External type 1 • 2 = for OSPF External type 2 route-map map-name (OPTIONAL) Enter the keywords route-map then the name of the route map.
redistribute isis Redistribute IS-IS routing information throughout the OSPF instance. S4820T Syntax redistribute isis [tag] [level-1 | level-1-2 | level-2] [metric metric-value | metric-type type-value] [route-map map-name] [tag tag-value] To disable redistribution, use the no redistribute isis [tag] [level-1 | level-1-2 | level-2] [metric metric-value | metric-type typevalue] [route-map map-name] [tag tag-value] command. Parameters tag (OPTIONAL) Enter the name of the IS-IS routing process.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. router-id To configure a fixed router ID, use this command. S4820T Syntax router-id ip-address To remove the fixed router ID, use the no router-id ip-address command.
Usage Information You can configure an arbitrary value in the IP address format for each router. However, each router ID must be unique. If you use this command on an OSPF router process, which is already active (that is, has neighbors), a prompt reminding you that changing the router-id brings down the existing OSPF adjacency. The new router ID is effective at the next reload. Example Dell(conf)#router ospf 100 Dell(conf-router_ospf)#router-id 1.1.1.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.9.1.0 Added support for VRF. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. You must have an IP address assigned to an interface to enter ROUTER OSPF mode and configure OSPF.
Example Version Description pre- 6.1.1.1 Introduced on the E-Series. Dell(conf-router_ospf)#show config ! router ospf 3 passive-interface 0 TenGigabitEthernet 1/1 Dell(conf-router_ospf)# show ip ospf Display information on the OSPF process configured on the switch. S4820T Syntax Parameters show ip ospf [process-id | vrf vrf name] process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process.
Usage Information Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. If you delete all the network area commands for Area 0, the show ip ospf command output does not list Area 0. The following describes the show ip ospf command shown in the following example. Line Beginning with Description “Routing Process...” Displays the OSPF process ID and the IP address associated with the process ID. “Supports only...
show ip ospf asbr Display all autonomous system boundary router (ASBR) routers visible to OSPF. S4820T Syntax Parameters show ip ospf [process-id | vrf vrf-name] asbr process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process. vrf vrf-name Enter the keyword vrf followed by the name of the VRF to show all ASBR routers visible to the OSPF process that is tied to a specific VRF.
NOTE: ASBRs that are not in directly connected areas are also displayed. You can determine if an ASBR is in a directly connected area (or not) by the flags. For ASBRs in a directly connected area, E flags are set. In the following example, router 1.1.1.1 is in a directly connected area since the Flag is E/-/-/. For remote ASBRs, the E flag is clear (-/-/-/). Example Dell#show ip ospf 1asbr RouterID 3.3.3.3 1.1.1.1 Dell# Flags -/-/-/ E/-/-/ Cost Nexthop 2 10.0.0.2 0 0.0.0.
Usage Information Example Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support of Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. The following describes the show ip ospf process-id database command shown in the following example. Field Description Link ID Identifies the router ID.
13.1.2.0 172.16.1.0 Dell> Related Commands 13.1.1.1 13.1.1.1 1184 0x8000006b 0x1c22 148 0x8000006d 0x533b 0 0 show ip ospf database asbr-summary — displays only ASBR summary LSA information. show ip ospf database asbr-summary Display information about autonomous system (AS) boundary LSAs. S4820T Syntax Parameters show ip ospf [process-id | vrf vrf-name] database asbr-summary [link-state-id] [adv-router ip-address] process-id Enter the OSPF Process ID to show a specific process.
Usage Information Example Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. The following describes the show ip ospf database asbr-summary command shown in the following example.
LS age: 1437 Options: (No TOS-capability, No DC, E) LS type: Summary Asbr Link State ID: 103.1.50.1 Advertising Router: 1.1.1.10 LS Seq Number: 0x8000000f Checksum: 0x8221 Length: 28 Network Mask: /0 TOS: 0 Metric: 2 LS age: 473 Options: (No TOS-capability, No DC, E) LS type: Summary Asbr Link State ID: 104.1.50.1 Advertising Router: 1.1.1.10 LS Seq Number: 0x80000010 Checksum: 0x4198 Length: 28 --More-Related Commands show ip ospf database — displays OSPF database information.
Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Example Field Description Checksum Displays the Fletcher checksum of the LSA’s complete contents. Length Displays the length in bytes of the LSA. Network Mask Displays the network mask implemented on the area. Metrics Type Displays the external type. TOS Displays the Type of Service (TOS) options. Option 0 is the only option. Metric Displays the LSA metric. Forward Address Identifies the address of the forwarding router. Data traffic is forwarded to this router.
Related Commands show ip ospf database — displays OSPF database information. show ip ospf database network Display the network (type 2) LSA information. S4820T Syntax Parameters show ip ospf [process-id | vrf vrf-name] database network [link-state-id] [adv-router ip-address] process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process.
Usage Information Example Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.1 Introduced on the E-Series. The following describes the show ip ospf process-id database network command shown in the following example. Field Description LS Age Displays the LSA’s age.
Length: 36 Network Mask: Attached Attached Attached /24 Router: 20.20.20.8 Router: 20.20.20.9 Router: 20.20.20.7 Network (Area 0.0.0.1) LS age: 252 Options: (TOS-capability, No DC, E) LS type: Network Link State ID: 192.10.10.2 Advertising Router: 192.10.10.2 LS Seq Number: 0x80000007 Checksum: 0x4309 Length: 36 Network Mask: /24 Attached Router: 192.10.10.2 Attached Router: 20.20.20.1 Attached Router: 20.20.20.5 Dell# Related Commands show ip ospf database — displays OSPF database information.
Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
adv-router ipaddress • the router’s OSPF router ID for Type 1 LSAs or Type 4 LSAs • the default destination (0.0.0.0) for Type 5 LSAs (OPTIONAL) Enter the keywords adv-router and the ipaddress to display only the LSA information about that router. Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Item Description • Example E or No E is displayed on whether the originating router can accept AS External LSAs. LS Type Displays the LSA’s type. Link State ID Displays the Link State ID. Advertising Router Identifies the advertising router’s ID. Checksum Displays the Fletcher checksum of the LSA’s complete contents. Length Displays the length in bytes of the LSA. Opaque Type Displays the Opaque type field (the first 8 bits of the Link State ID).
show ip ospf database opaque-as Display the opaque-as (type 11) LSA information. Syntax Parameters show ip ospf process-id database opaque-as [link-state-id] [adv-router ip-address] process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process. link-state-id (OPTIONAL) Specify LSA ID in dotted decimal format.
Related Commands Version Description pre-6.1.1.1 Introduced on the E-Series. show ip ospf database — displays OSPF database information. show ip ospf database opaque-link Display the opaque-link (type 9) LSA information. S4820T Syntax Parameters show ip ospf [process-id | vrf vrf-name] database opaque-link [link-state-id] [adv-router ip-address] process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process.
Related Commands Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.1 Introduced on the E-Series. show ip ospf database — displays OSPF database information. show ip ospf database router Display the router (type 1) LSA information.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information 1324 Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added supported for VRF. 9.0.20 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Example Item Description Number of Links Displays the number of active links to the type of router (Area Border Router or AS Boundary Router) listed in the previous line. Link connected to: Identifies the type of network to which the router is connected. (Link ID) Identifies the link type and address. (Link Data) Identifies the router interface address. Number of TOS Metric Lists the number of TOS metrics. TOS 0 Metric Lists the number of TOS 0 metrics.
(Link Data) Router Interface address: 192.68.140.2 Number of TOS metric: 0 TOS 0 Metric: 1 Link connected to: a Stub Network (Link ID) Network/subnet number: 11.1.5.0 --More-Related Commands show ip ospf database — displays OSPF database information. show ip ospf database summary Display the network summary (type 3) LSA routing information.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.1 Introduced on the E-Series.
Example Dell#show ip ospf 100 database summary OSPF Router with ID (1.1.1.10) (Process ID 100) Summary Network (Area 0.0.0.0) LS age: 1551 Options: (No TOS-capability, DC, E) LS type: Summary Network Link State ID: 192.68.16.0 Advertising Router: 192.168.17.1 LS Seq Number: 0x80000054 Checksum: 0xb5a2 Length: 28 Network Mask: /24 TOS: 0 Metric: 1 LS age: 9 Options: (No TOS-capability, No DC, E) LS type: Summary Network Link State ID: 192.68.32.0 Advertising Router: 1.1.1.
interface (OPTIONAL) Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords portchannel then a number. The range is from 1 to 128.
Example Item Description GigabitEthernet... This line identifies the interface type slot/port and the status of the OSPF protocol on that interface. Internet Address... This line displays the IP address, network mask and area assigned to this interface. Process ID... This line displays the OSPF Process ID, Router ID, Network type and cost metric for this interface. Transmit Delay... This line displays the interface’s settings for Transmit Delay, State, and Priority.
Hello due in 00:00:08 Neighbor Count is 3, Adjacent neighbor count is 2 Adjacent with neighbor 192.168.253.5 (Designated Router) Adjacent with neighbor 192.168.253.3 (Backup Designated Router) Loopback 0 is up, line protocol is up Internet Address 192.168.253.2/32, Area 0.0.0.1 Process ID 1, Router ID 192.168.253.2, Network Type LOOPBACK, Cost: 1 Loopback interface is treated as a stub Host. Dell> show ip ospf neighbor Display the OSPF neighbors connected to the local router.
Usage Information Example Version Description pre-6.1.1.1 Introduced on the E-Series. The following describes the show ip ospf process-id neighbor command shown in the following example. Item Description Neighbor ID Displays the neighbor router ID. Pri Displays the priority assigned neighbor. State Displays the OSPF state of the neighbor. Dead Time Displays the expected time until FTOS declares the neighbor dead. Address Displays the IP address of the neighbor.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
172.30.1.0 Dell# 2 13.0.0.3 Te 1/47 1 Intra-Area show ip ospf statistics Display OSPF statistics. S4820T Syntax Parameters show ip ospf [process-id | vrf vrf-name] statistics global | [interface name {neighbor router-id}] process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series.
The following describes the error definitions for the show ip ospf statistics process-id global command. Example Error Type Description Intf_Down Received packets on an interface that is either down or OSPF is not enabled. Non-Dr Received packets with a destination address of ALL_DRS even though SELF is not a designated router. Self-Org Receive the self originated packet. Wrong_Len The received packet length is different to what was indicated in the OSPF header.
Wrong-Len Auth-Err Version No-Buffer Q-OverFlow 0 0 0 0 0 Invld-Nbr MD5-Err AreaMis Seq-No Unkown-Pkt 0 0 0 0 0 Nbr-State 0 Chksum 0 Conf-Issues 0 Socket 0 Error packets (Only for TX) Socket Errors Dell# Usage Information Example (Statistics) 0 The show ip ospf process-id statistics command displays the error packet count received on each interface as: • The hello-timer remaining value for each interface • The wait-timer remaining value for each interface • The grace-timer remaining value for e
show ip ospf timers rate-limit Show the LSA currently in the queue waiting for timers to expire. S4820T Syntax Parameters show ip ospf [process-id | vrf vrf-name] timers rate-limit process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process. vrf vrf-name Enter the keyword vrf followed by the name of the VRF to view LSAs corresponding to a specific VRF that are currently in queue waiting for timers to expire.
show ip ospf topology Display routers in directly connected areas. S4820T Syntax Parameters Defaults Command Modes Command History show ip ospf [process-id | vrf vrf-name] topology process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process. vrf vrf-name Enter the keyword vrf followed by the name of the VRF to information on routers corresponding to a specific VRF that are in directly connected areas.
1.1.1.1 Dell# E/-/-/ 1 10.0.0.1 Gi 7/1 1 summary-address To advertise one external route, set the OSPF ASBR. S4820T Syntax summary-address ip-address mask [not-advertise] [tag tag-value] To disable summary address, use the no summary-address ip-address mask command. Parameters ip-address Specify the IP address in dotted decimal format of the address to summarize. mask Specify the mask in dotted decimal format of the address to summarize.
Usage Information The area range command summarizes routes for the different areas. With the not-advertise parameter configured, you can use this command to filter out some external routes. For example, if you want to redistribute static routes to OSPF, but you don't want OSPF to advertise routes with prefix 1.1.0.0, you can configure the summary-address 1.1.0.0 255.255.0.0 not-advertise to filter out all the routes fall in range 1.1.0.0/16. Related Commands area range — summarizes routes within an area.
Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.1 Introduced on the E-Series. Usage Information Setting the delay and holdtime parameters to a low number enables the switch to an alternate path quickly but requires more CPU usage.
• hold-interval: 5000 msec • max-interval: 5000 msec Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 9.0.2.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Introduced on the S4810. OSPFv3 Commands Open shortest path first version 3 (OSPFv3) for IPv6 is supported on the S4820T platform.
keyencryptiontype (OPTIONAL) Specifies if the key is encrypted. key Text string used in authentication. The values are 0 (key is not encrypted) or 7 (key is encrypted). For MD5 authentication, the key must be 32 hex digits (nonencrypted) or 64 hex digits (encrypted). For SHA-1 authentication, the key must be 40 hex digits (non-encrypted) or 80 hex digits (encrypted). Defaults Not configured. Command Modes ROUTER OSPFv3 Command History This guide is platform-specific.
show crypto ipsec policy – displays the configuration of IPsec authentication policies. area encryption Configure an IPsec encryption policy for OSPFv3 packets in an OSPFv3 area. S4820T Syntax Parameters area area-id encryption ipsec spi number esp encryptionalgorithm [key-encryption-type] key authentication-algorithm [key-encryption-type] key area area-id Area for which OSPFv3 traffic is to be encrypted. For area-id, enter a number. The range is from 0 to 4294967295.
keyencryptiontype (OPTIONAL) Specifies if the authentication key is encrypted. key Text string used in authentication. Valid values: 0 (key is not encrypted) or 7 (key is encrypted). For MD5 authentication, the key must be 32 hex digits (nonencrypted) or 64 hex digits (encrypted). For SHA-1 authentication, the key must be 40 hex digits (non-encrypted) or 80 hex digits (encrypted). null Causes an encryption policy configured for the area to not be inherited on the interface. Defaults Not configured.
The configuration of IPsec encryption on an interface-level takes precedence over an area-level configuration. If you remove an interface configuration, an area encryption policy that has been configured is applied to the interface. To remove an IPsec encryption policy from an interface, enter the no area area-id encryption spi number command. Related Commands ipv6 ospf encryption – configures an IPsec encryption policy on an OSPFv3 interface.
debug ipv6 ospf bfd Display debug information and interface types for bidirectional forwarding detection (BFD) on OSPF IPv6 packets. S4820T Syntax Parameters [no] debug ipv6 ospf bfd [interface] interface (OPTIONAL) Enter one of the following keywords and slot/ port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
00:59:27 : OSPFv3INFO: Enabling BFD for NBRIP fe80:0000:0000:0000:0201:e8ff:fe8b:7720 00:59:27 : OSPFv3INFO: Completed Enabling BFD on interface Te 1/2 00:59:27 : OSPFv3INFO: Completed Interface mode BFD configuration on Te 1/2!! 00:59:27 : OSPFv3INFO: Enabling BFD for NBRIP fe80:0000:0000:0000:0201:e8ff:fe8b:7720 00:59:27 : OSPFv3INFO: Ospf3_register_bfd ospf key 27648 00:59:27 : OSPFv3INFO: OSPFV3 Enabling BFD for NBRIP fe80:0000:0000:0000:0201:e8ff:fe8b:7720 Interface Te 1/2 IfIndex 34145282 00:59:27 : O
Example Command Fields Version Description 9.2(1.0) Introduced on the Z9500. 9.1.(0.0) Introduced on the S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 7.8.1.0 Added support for C-Series. 7.4.1.0 Introduced on E-Series. Dell#debug ipv6 ospf packet OSPFv3 packet related debugging is on for all interfaces 05:21:01 : OSPFv3: Sending, Ver:3, Type:1(Hello), Len:40, Router ID:223.255.255.254, Area ID:0, Inst:0, on Po 255 05:21:03 : OSPFv3: Received, Ver:3, Type:1(Hello), Len:40, Router ID:223.
Lines Beginning With or Including Description Chksum: Displays the OSPF3 checksum. default-information originate Configure the Dell Networking OS to generate a default external route into an OSPFv3 routing domain. S4820T Syntax default-information originate [always] [metric metric-value] [metric-type type-value] [route-map map-name] To return to the default values, use the no default-information originate command.
Related Commands redistribute — redistributes routes from other routing protocols into OSPFv3. graceful-restart grace-period Enable OSPFv3 graceful restart globally by setting the grace period (in seconds) that an OSPFv3 router’s neighbors continues to advertise the router as adjacent during a graceful restart. S4820T Syntax graceful-restart grace-period seconds To disable OSPFv3 graceful restart, enter no graceful-restart graceperiod.
function in a “restarting-only” role. In a “restarting-only” role, OSPFv3 does not participate in the graceful restart of a neighbor. graceful-restart mode Specify the type of events that trigger an OSPFv3 graceful restart. S4820T Syntax graceful-restart mode {planned-only | unplanned-only} To disable graceful restart mode, enter no graceful-restart mode. Parameters planned-only (OPTIONAL) Enter the keywords planned-only to indicate graceful restart is supported in a planned restart condition only.
By default, both planned and unplanned restarts trigger an OSPFv3 graceful restart. Selecting one or the other mode restricts OSPFv3 to the single selected mode. ipv6 ospf area Enable IPv6 OSPF on an interface. S4820T Syntax ipv6 ospf process id areaarea id To disable OSPFv6 routing for an interface, use the no ipv6 ospf process-id area area-id command. Parameters process-id Enter the process identification number. area area-id Specify the OSPF area. The range is from 0 to 65535.
keyencryptiontype (OPTIONAL) Specifies if the key is encrypted. key Text string used in authentication. Valid values: 0 (key is not encrypted) or 7 (key is encrypted). For MD5 authentication, the key must be 32 hex digits (nonencrypted) or 64 hex digits (encrypted). For SHA-1 authentication, the key must be 40 hex digits (non-encrypted) or 80 hex digits (encrypted). Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific.
show crypto ipsec sa ipv6 – displays the security associations set up for OSPFv3 interfaces in authentication policies. ipv6 ospf bfd all-neighbors Establish BFD sessions with all OSPFv3 neighbors on a single interface or use non-default BFD session parameters.
Usage Information Version Description 9.2.0.0 Introduced on the Z9000, S4820T, and S4810. This command provides the flexibility to fine-tune the timer values based on individual interface needs when you configure ipv6 ospf BFD in CONFIGURATION mode. Any timer values specified with this command overrides timers set using the bfd all-neighbors command. Using the no form of this command does not disable BFD if you configure BFD in CONFIGURATION mode.
• TenGigabitEthernet—Default cost is 1 • FortygigEthernet — Default cost is 1 • Ethernet—Default cost is 10 ipv6 ospf dead-interval Set the time interval since the last hello-packet was received from a router. After the time interval elapses, the neighboring routers declare the router down. S4820T Syntax ipv6 ospf dead-interval seconds To return to the default time interval, use the no ipv6 ospf dead-interval command. Parameters seconds Enter the time interval in seconds.
ipv6 ospf encryption Configure an IPsec encryption policy for OSPFv3 packets on an IPv6 interface. S4820T Syntax Parameters ipv6 ospf encryption {null | ipsec spi number esp encryptionalgorithm [key-encryption-type] key athentication-algorithm [key-encryption-type] key}} null Causes an encryption policy configured for the area to not be inherited on the interface. ipsec spi number Security Policy index (SPI) value that identifies an IPsec security policy. The range is from 256 to 4294967295.
For SHA-1 authentication, the key must be 40 hex digits (non-encrypted) or 80 hex digits (encrypted). Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.1.(0.0) Introduced on the S4810 and Z9000. 8.4.2.
To disable the helper-reject role, enter no ipv6 ospf graceful-restart helper-reject. Defaults The helper-reject role is not configured. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.1.(0.0) Introduced on the S4810 and Z9000. 8.4.2.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.1.(0.0) Introduced on the S4810 and Z9000. 7.8.1.0 Added support for the C-Series. 7.4.1.0 Introduced on the E-Series. 8.3.19.0 Introduced on the S4820T.
Use this command for interfaces connected to multi-access networks, not pointto-point networks. ipv6 router ospf Enable OSPF for IPv6 router configuration. S4820T Syntax ipv6 router ospf process-id [vrf vrf-name] To exit OSPF for IPv6, use the no ipv6 router ospf process-id command. Parameters process-id Enter the process identification number. The range is from 1 to 65535. vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to install IPv6 routes in that VRF.
To disable packet forwarding over multiple paths, use the no maximum-paths command. Parameters number Defaults 8 Command Modes ROUTER OSPF Command History Specify the number of paths. The range is from 1 to 64. The default is 8 paths. Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.
Command Modes ROUTER OSPF for OSPFv2 ROUTER OSPFv3 for OSPFv3 Command History Usage Information Version Description 9.2(1.0) Introduced on the Z9500. 9.1.(0.0) Introduced support for OSPFv3 on the S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 7.8.1.0 Added support for the C-Series. 7.4.1.0 Introduced on the E-Series. By default, no interfaces are passive. Routing updates are sent to all interfaces on which the routing protocol is enabled.
connected Enter the keyword connected to redistribute routes from physically connected interfaces. static Enter the keyword static to redistribute manually configured routes. metric metricvalue Enter the keyword metric then the metric value. The range is from 0 to 16777214. The default is 20. metric-type type-value (OPTIONAL) Enter the keywords metric-type then the OSPFv3 link state type of 1 or 2 for default routes.
Version Description 7.8.1.0 Added support for the C-Series. 7.4.1.0 Introduced on the E-Series. Usage Information To redistribute the default route (x:x:x:x::x), use the default-information originate command. Related Commands default-information originate – configures default external route into OSPFv3. router-id Designate a fixed router ID. S4820T Syntax router-id ip-address To return to the previous router ID, use the no router-id ip-address command.
If this command is used on an OSPFv3 process that is already active (has neighbors), all the neighbor adjacencies are brought down immediately and new sessions are initiated with the new router ID. Related Commands clear ipv6 ospf process – resets an OSPFv3 router process. show crypto ipsec policy Display the configuration of IPsec authentication and encryption policies.
Policy name : OSPFv3-1-502 Policy refcount : 1 Inbound ESP SPI : 502 (0x1F6) Outbound ESP SPI : 502 (0x1F6) Inbound ESP Auth Key : 123456789a123456789b123456789c12 Outbound ESP Auth Key : 123456789a123456789b123456789c12 Inbound ESP Cipher Key : 123456789a123456789b123456789c123456789d12345678 Outbound ESP Cipher Key : 123456789a123456789b123456789c123456789d12345678 Transform set : esp-3des esp-md5-hmac Crypto IPSec client security policy data Policy name : OSPFv3-0-501 Policy refcount : 1 Inbound ESP SPI
Inbound AH SPI The authentication header (AH) security policy index (SPI) for inbound and outbound links. Outbound AH SPI Inbound AH Key The AH key for inbound and outbound links. Outbound AH Key show crypto ipsec sa ipv6 Display the IPsec security associations (SAs) used on OSPFv3 interfaces.
Usage Information The show crypto ipsec sa ipv6 command output displays security associations set up for OSPFv3 links in IPsec authentication and encryption policies on the router. Related Commands show crypto ipsec policy – displays the configuration of IPsec authentication and encryption policies.
show crypto ipsec sa ipv6 Command Fields Field Description Interface IPv6 interface Link local address IPv6 address of interface IPSecv6 policy name Name of the IPsec security policy applied to the interface. inbound/outbound ah Authentication policy applied to inbound or outbound traffic. inbound/outbound esp Encryption policy applied to inbound or outbound traffic. spi Security policy index number used to identify the policy.
grace-lsa Defaults none Command Modes EXEC (OPTIONAL): Enter the keywords grace-lsa to display the Type-11 Grace LSAs sent and received on an OSPFv3 router. EXEC Privilege Command History Version Description 9.7(0.0) Added support for VRF. 9.2(1.0) Introduced on the Z9500. 9.1.(0.0) Added support for OSPFv3 on the S4810 and Z9000. 8.4.2.2 Added support for the display of graceful restart parameters and Type-11 Grace LSAs on E-Series TeraScale routers. 8.3.19.0 Introduced on the S4820T. 7.
AS Scope LSA Count 0 AS Scope LSA Cksum sum 0 Originate New LSAS 50 Rx New LSAS 22 Ext LSA Count 0 Rte Max Eq Cost Paths 10 GR grace-period 180 GR mode planned and unplanned Area 0 database summary Type Count/Status Brd Rtr Count 1 AS Bdr Rtr Count 1 LSA count 6 Rtr LSA Count 2 Net LSA Count 1 Inter Area Pfx LSA Count 1 Inter Area Rtr LSA Count 0 Group Mem LSA Count 0 Type-7 LSA count 0 Intra Area Pfx LSA Count 2 Intra Area TE LSA Count 2 Area 1 database summary Type Count/Status Brd Rtr Count 1 AS Bdr Rtr
NOTE: If you do not specify this option, neighbors corresponding to the default VRF are displayed. interface Defaults none Command Modes EXEC Command History Usage Information (OPTIONAL) Enter one of the following keywords and slot/ port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
Dell# show ipv6 ospf neighbor Display the OSPF neighbor information on a per-interface basis. S4820T Syntax Parameters show ipv6 ospf [process-number] [vrf vrf-name] neighbor [interface] processnumber Enter the OSPF process number. vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to display OSPF neighbors corresponding to that VRF. NOTE: If you do not specify this option, neighbors corresponding to the default VRF are displayed.
Example Version Description 7.4.1.0 Introduced on the E-Series. Dell#show ipv6 ospf 3 neighbor gi 1/2 Neighbor ID Interface 63.114.8.36 1/2 Pri State 1 FULL/DR Dead Time 00:00:38 Interface ID 4 Te Dell# timers spf Set the time interval between when the switch receives a topology change and starts a shortest path first (SPF) calculation. S4820T Syntax timers spf delay holdtime To return to the default, use the no timers spf command. Parameters Defaults delay Enter a number as the delay.
Dell(conf-ipv6-router_ospf)# Dell(conf-ipv6-router_ospf)#show config ! ipv6 router ospf 1 timers spf 2 5 Dell(conf-ipv6-router_ospf)# Dell(conf-ipv6-router_ospf)#end Dell# Open Shortest Path First (OSPFv2 and OSPFv3) 1379
41 Policy-based Routing (PBR) Policy-based routing (PBR) allows you to apply routing policies to specific interfaces. To enable PBR, create a redirect list and apply it to the interface. After the redirect list is applied to the interface, all traffic passing through the interface is subject to the rules defined in the redirect list. PBR is supported by the Dell Networking Operating System (OS).
Related Commands Version Description 8.4.2.0 Introduced on the E-Series Tera Scale. 7.7.1.0 Introduced on the E-Series ExaScale. ip redirect-list – enables an IP Redirect List. ip redirect-group Apply a redirect list (policy-based routing) on an interface. You can apply multiple redirect lists to an interface by entering this command multiple times. S4820T Syntax ip redirect-group redirect-list-name To remove a redirect list from an interface, use the no ip redirect-group name command.
into the PBR CAM region. When incoming traffic hits an entry in the CAM, the traffic is redirected to the corresponding next-hop IP address specified in the rule. NOTE: Apply the redirect list to physical, VLAN, or LAG interfaces only. Related Commands • show cam pbr – displays the content of the PBR CAM. • show ip redirect-list – displays the redirect-list configuration. ip redirect-list Configure a redirect list and enter REDIRECT-LIST mode.
permit Configure a permit rule. A permit rule excludes the matching packets from PBR classification and routes them using conventional routing. S4820T Syntax permit {ip-protocol-number | protocol-type} {source mask | any | host ip-address} {destination mask | any | host ip-address} [bit] [operators] To remove the rule, use one of the following: Parameters • If you know the filter sequence number, use the no seq sequence-number syntax command.
• operator Defaults none Command Modes REDIRECT-LIST Command History urg = urgent field (OPTIONAL) For TCP and UDP parameters only. Enter one of the following logical operand: • eq = equal to • neq = not equal to • gt = greater than • lt= less than • range = inclusive range of ports (you must specify two ports for the portcommand parameter.) Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. 8.4.2.
{destination mask | any | host ip-address} [operator] command. Parameters redirect Enter the keyword redirect to assign the sequence to the redirect list. ip-address Enter the IP address of the forwarding router. slot/port Enter the keyword slot / port followed by the slot/port information. tunnel Enter the keyword tunnel to configure the tunnel setting. tunnel-id Enter the keyword tunnel-id to redirect the traffic. track Enter the keyword track to enable the tracking.
• Defaults none Command Modes REDIRECT-LIST Command History eq = equal to • neq = not equal to • gt = greater than • lt = less than • range = inclusive range of ports (you must specify two ports for theport command parameter.) Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Added support for the track-id on the S4810, S4820T, S6000, and Z9000. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. 8.4.2.1 Introduced on the C-Series and S-Series. 8.4.2.
redirect Enter the keyword redirect to assign the sequence to the redirect list. ip-address Enter the keyword IP address of the forwarding router. tunnel Enter the keyword tunnel to configure the tunnel setting. tunnel-id Enter the keyword tunnel-id to redirect the traffic. track Enter the keyword track to enable the tracking. track Enter the keyword track to track object-id.
lt= less than • range = inclusive range of ports (you must specify two ports for the port command parameter.) source port Enter the keywords source-port then the port number to be matched in the ACL rule in the ICAP rule destinationport Enter the keywords destination-port then the port number to be matched in the ACL rule in the ICAP rule. source-portrange Enter the keywords Source-port-range then the range of the start port to end port to be matched in the ACL rule in the ICAP rule.
summary Defaults none Command Modes EXEC Command History Enter the keyword summary to view only the total number of CAM entries. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. Usage Information The show cam pbr command displays the PBR CAM content.
show ip redirect-list View the redirect list configuration and the interfaces it is applied to. S4820T Syntax Parameters Command Modes Command History Example show ip redirect-list redirect-list-name redirect-listname • EXEC • EXEC Privilege Enter the name of a configured Redirect list. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000.
PIM-Sparse Mode (PIM-SM) 42 The protocol-independent multicast (PIM) commands are supported by the Dell Networking operating software on the platform. IPv4 PIM-Sparse Mode Commands The following describes the IPv4 PIM-sparse mode (PIM-SM) commands. clear ip pim rp-mapping The bootstrap router (BSR) feature uses this command to remove all or particular rendezvous point (RP) advertisement.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. This command re-applies the RP mapping logic for all the groups learnt by the node. Any stale information corresponding to the existing mapping configuration is updated.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. If you use this command on a local VLT node, all multicast routes from the local PIM TIB, the entire multicast route table, and all the entries in the data plane are deleted. The local VLT node sends a request to the peer VLT node to download multicast routes learned by the peer.
register (OPTIONAL) Enter the keyword register to view PIM register address in dotted decimal format (A.B.C.D). state (OPTIONAL) Enter the keyword state to view PIM state changes. timer [assert | hello | joinprune | register] (OPTIONAL) Enter the keyword timer to view PIM timers.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
hash-masklength (OPTIONAL) Enter the hash mask length. The range is from zero (0) to 32. The default is 30. priority (OPTIONAL) Enter the priority used in Bootstrap election process. The range is from zero (0) to 255. The default is zero (0). Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series on port-channels and the SSeries.
Version Description 9.7(0.0) Removed the in and out parameters. Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series for the port-channels and the SSeries. 7.7.1.0 Introduced on the E-Series.
Example Version Description 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced Dell(conf)# ip access-list standard map1 Dell(config-std-nacl)# permit 224.0.0.1/24 Dell(config-std-nacl)#exit Dell(conf)#int tengig 1/1 Dell(config-if-te-1/1)# ip pim ingress-interface-map map1 ip pim neighbor-filter To prevent a router from participating in protocol independent multicast (PIM), configure this feature.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series and S-Series. 7.6.1.0 Introduced on the E-Series. Do not enter this command before creating the access-list. ip pim query-interval Change the frequency of PIM Router-Query messages. Syntax ip pim query-interval seconds To return to the default value, use the no ip pim query-interval seconds command.
ip pim register-filter To prevent a PIM source DR from sending register packets to an RP for the specified multicast source and group, use this feature. S4820T Syntax ip pim [vrf vrf-name] register-filter access-list To return to the default, use the no ip pim [vrf vrf-name] registerfilter access-list command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF. NOTE: Applies to specific VRF if input is provided, else applies to Default VRF.
ip pim rp-address Configure a static PIM rendezvous point (RP) address for a group or access-list. S4820T Syntax ip pim [vrf vrf-name] rp-address address {group-address groupaddress mask} [override] To remove an RP address, use the no ip pim [vrf vrf-name] rp-address address {group-address group-address mask} [override] command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF. NOTE: Applies to specific VRF if input is provided, else applies to Default VRF.
Usage Information Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. pre- 6.1.1.1 Introduced on the E-Series. First-hop routers use this address by to send register packets on behalf of source multicast hosts. The RP addresses are stored in the order in which they are entered. The RP is chosen based on a longer prefix match for a group. The RP selection does not depend on dynamic or static RP assignments.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series for the port-channels and the SSeries. The interface must be enabled (the no shutdown command) and not have the switchport command configured. Multicast must also be enabled globally (using the ip multicast-lag-hashing command). PIM is supported on the portchannel interface.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series for the port-channels and the SSeries. 7.7.1.1 Introduced This command configures an expiration timer for all S.G entries, unless they are assigned to an Extended ACL.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.1 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.5.1.0 Introduced on the E-Series. Dell Networking OS supports standard access lists for the SSM range. You cannot use extended ACLs for configuring the SSM range.
Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure the PIM router on that VRF. NOTE: Applies to specific VRF if input is provided, else applies to Default VRF. infinity (OPTIONAL) Enter the keyword infinity to never switch to the source-tree. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced on the E-Series ExaScale. By default, when you enable PIM-SM snooping, a switch floods all multicast traffic to the PIM designated router (DR), including unnecessary multicast packets. To minimize the traffic sent over the network to the designated router, you can disable designated-router flooding.
Example Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. Dell#show ip pim bsr-router PIMv2 Bootstrap information This system is the Bootstrap Router (v2) BSR address: 7.7.7.
Usage Information Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. The following describes the show ip pim interface command shown in the following example.
165.87.31.200 165.87.31.201 Vl 30 v2/S 1 30 1 show ip pim neighbor View PIM neighbors. S4820T Syntax Parameters show ip pim [vrf vrf-name] neighbor vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure this setting on that VRF. NOTE: Applies to specific VRF if input is provided, else applies to Default VRF. Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific.
Field Description Uptime/expires Displays the amount of time the neighbor has been up then the amount of time until the neighbor is removed from the multicast routing table (that is, until the neighbor hold time expires). Ver Displays the PIM version number. • DR prio/Mode Example v2 = PIM version 2 Displays the Designated Router priority and the mode.
Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. Example Dell#show ip pim rp Group RP 224.2.197.115 165.87.20.4 224.2.217.146 165.87.20.4 224.3.3.3 165.87.20.4 225.1.2.1 165.87.20.4 225.1.2.2 165.87.20.4 229.1.
The following is a list of the Dell Networking OS version history for this command. Usage Information Example (#2) Version Description 9.5(0.1) Introduced on the Z9500. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.4.1.1 Introduced on the E-Series ExaScale. The following describes the show ip pim snooping interface commands shown in the following example. Field Description Interface Displays the VLAN interfaces with PIM-SM snooping enabled.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.4.1.1 Introduced on the E-Series ExaScale.
show ip pim snooping tib Display information from the tree information base (TIB) PIM-SM snooping discovered about multicast group members and states. Syntax Parameters show ip pim snooping tib [vlan vlan-id] [group-address [sourceaddress]] vlan vlan-id (OPTIONAL) Enter a VLAN ID to display TIB information PIMSM snooping discovered on a specified VLAN. The valid VLAN IDs range is from 1 to 4094. group-address (OPTIONAL) Enter the group address in dotted decimal format (A.B.C.
Example Field Description flags List the flags to define the entries: • S = PIM Sparse Mode • C = directly connected • L = local to the multicast group • P = route was pruned • R = the forwarding entry is pointing toward the RP • F = Dell Networking OS is registering this entry for a multicast source • T = packets were received via Shortest Tree Path • J = first packet from the last hop router is received and the entry is ready to switch to SPT • K=acknowledge pending state Incoming in
TenGigabitEthernet 2/13 DR Port -/TenGigabitEthernet 2/20 RPF 165.87.32.10 00:00:08/00:02:52 show ip pim ssm-range Display the non-default groups added using the SSM range feature. S4820T Syntax Parameters show ip pim [vrf vrf-name] ssm-range vrf vrf-name Defaults none Command Modes • EXEC • EXEC Privilege Command History Exmaple (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure this setting on that VRF. Version Description 9.7(0.0) Introduced on the S6000-ON.
Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure this setting on that VRF. NOTE: Applies to specific VRF if input is provided, else applies to Default VRF. Command Modes Command History • • EXEC EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
2582/2583 Joins sent/received 5/0 Prunes sent/received 0/0 Candidate-RP advertisements sent/received 0/0 BSR messages sent/received 0/0 State-Refresh messages sent/received 0/0 MSDP updates sent/received 0/0 Null Register messages sent/received 0/0 Register-stop messages sent/received Data path event summary: 0 no-cache messages received 0 last-hop switchover messages received 0/0 pim-assert messages sent/received 0/0 register messages sent/received show ip pim tib View the PIM tree information base (TIB).
Usage Information Example Version Description 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. The following describes the show ip pim tib command shown in the following example. Field Description (S, G) Displays the entry in the multicast PIM database. uptime Displays the amount of time the entry has been in the PIM route table. expires Displays the amount of time until the entry expires and is removed from the database.
R - RP-bit set, F - Register flag, T - SPT-bit set, J Join SPT, M - MSDP created entry, A - Candidate for MSDP Advertisement K - Ack-Pending State Timers: Uptime/Expires Interface state: Interface, next-Hop, State/Mode (*, 225.1.1.1), uptime 00:40:16, expires 00:00:00, RP 20.40.4.4, flags: SCJ Incoming interface: Vlan 2007, RPF neighbor 20.30.124.4 Outgoing interface list: Vlan 2006 Forward/Sparse 00:06:21/Never (20.10.4.9, 225.1.1.
Example 1424 Dell#show running-config pim ! ip pim snooping enable PIM-Sparse Mode (PIM-SM)
43 Port Monitoring The port monitoring feature allows you to monitor network traffic by forwarding a copy of each incoming or outgoing packet from one port to another port. Important Points to Remember • Port monitoring is supported on physical ports and logical interfaces, such as port channels and virtual local area networks (VLANs). • The monitoring (destination, “MG”) and monitored (source, “MD”) ports must be on the same switch.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
set ip dscp Configures the Differentiated Services Code Point (DSCP) value of the packets in the Encapsulated Remote Switched Port Analyzer (ERSPAN) traffic. To revert to the default value, use the no form of this command. dscp_value DSCP value of the packets in the ERSPAN traffic. The range is from 0 to 63. The default value is 0. set ip ttl Configures the IP time-to-live (TTL) value of the Encapsulated Remote Switched Port Analyzer (ERSPAN) traffic.
1 5.1.1.1 Related Command Vl 11 3.1.1.2 remote-ip 0 255 rx Flow show monitor session — displays the monitor session. show running-config monitor session — displays the running configuration of a monitor session. rate-limit Configure the rate-limit to limit the mirrored packets. Syntax rate-limit limit To remove the limit, use the no rate-limit limit command. Parameters limit Enter the rate-limit value. The range is from 0 to 40000 Megabits per second.
show config Display the current monitor session configuration. Syntax show config Defaults none Command Modes MONITOR SESSION (conf-mon-sess-session-ID) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Parameters session-ID (OPTIONAL) Enter a session identification number. The range is from 0 to 65535. Defaults none Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.0.
show running-config monitor session Display the running configuration of all monitor sessions or a specific session. Syntax show running-config monitor session {session-ID} To display the running configuration for all monitor sessions, use the show running-config monitor session command. Parameters session-ID (OPTIONAL) Enter a session identification number. The range from 0 to 65535. Defaults none Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific.
Related Commands monitor session — creates a monitoring session. show monitor session — displays a monitoring session. source (port monitoring) Configure a port monitor source. Syntax source {interface | range | any} destination interface direction {rx | tx | both} To disable a monitor source, use the no source interface destination interface direction {rx | tx | both} command.
direction {rx | tx | both} • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. • For a port channel interface, enter the keywords portchannel then a number. Enter the keyword direction then one of the packet directional indicators. • rx: to monitor receiving packets only. • tx: to monitor transmitting packets only. • both: to monitor both transmitting and receiving packets.
Private VLAN (PVLAN) 44 The private VLAN (PVLAN) feature of the Dell Networking operating software is supported on the S4820T platforms. Private VLANs extend the Dell Networking OS security suite by providing Layer 2 isolation between ports within the same private VLAN. A private VLAN partitions a traditional VLAN into subdomains identified by a primary and secondary VLAN pair. The Dell Networking OS private VLAN implementation is based on RFC 3069. For more information, refer to the following commands.
Port Types: • Community port: A community port is a port that belongs to a community VLAN and is allowed to communicate with other ports in the same community VLAN and with promiscuous ports. • Isolated port: An isolated port is a port that, in Layer 2, can only communicate with promiscuous ports that are in the same PVLAN. • Promiscuous port: A promiscuous port is a port that is allowed to communicate with any other port type.
Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series. private-vlan mode — sets the mode of the selected VLAN to community, isolated, or primary. private-vlan mapping secondary-vlan — maps secondary VLANs to the selected primary VLAN. show arp — displays the ARP table.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
To remove specific secondary VLANs from the configuration, use the no private-vlan mapping secondary-vlan vlan-list command syntax. Parameters vlan-list Enter the list of secondary VLANs to associate with the selected primary VLAN. The list can be in comma-delimited or hyphenated-range format, following the convention for the range input. Defaults none Command Modes INTERFACE VLAN Command History This guide is platform-specific.
switchport mode private-vlan Set PVLAN mode of the selected port. S4820T Syntax [no] switchport mode private-vlan {host | promiscuous | trunk} To remove PVLAN mode from the selected port, use the no switchport mode private-vlan command. Parameters host Enter the keyword host to configure the selected port or port channel as an isolated interface in a PVLAN. promiscuous Enter the keyword promiscuous to configure the selected port or port channel as an promiscuous interface.
Dell(conf-if-te-2/3)#switchport mode private-vlan trunk Dell(conf)#interface port-channel 10 Dell(conf-if-te-2/3)#switchport mode private-vlan promiscuous Related Commands private-vlan mode — sets the mode of the selected VLAN to community, isolated, or primary. private-vlan mapping secondary-vlan — sets the mode of the selected VLAN to primary and then associates the secondary VLANs to it.
Per-VLAN Spanning Tree Plus (PVST+) 45 The Dell Networking operating software implementation of per-VLAN spanning tree plus (PVST+) is based on the IEEE 802.1w standard spanning tree protocol. Dell Networking OS supports PVST+ on the S4820T platform. NOTE: For easier command line entry, the plus (+) sign is not used at the command line. description Enter a description of the PVST+. S4820T Syntax description {description} To remove the description, use the no description {description} command.
Related Commands Version Description 8.3.7.0 Introduced on the S4810. pre- 7.7.1.1 Introduced. protocol spanning-tree pvst — enter SPANNING TREE mode on the switch. disable Disable PVST+ globally. S4820T Syntax disable To enable PVST+, use the no disable command. Defaults Disabled. Command Modes CONFIGURATION (conf-pvst) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
extend system-id To augment the Bridge ID with a VLAN ID so that PVST+ differentiate between BPDUs for each VLAN, use extend system ID. If the VLAN receives a BPDU meant for another VLAN, PVST+ does not detect a loop, and both ports can remain in Forwarding state. S4820T Syntax extend system-id Defaults Disabled Command Modes PROTOCOL PVST Command History This guide is platform-specific.
Related Commands protocol spanning-tree pvst – enter SPANNING TREE mode on the switch. protocol spanning-tree pvst To enable PVST+ on a device, enter the PVST+ mode. S4820T Syntax protocol spanning-tree pvst To disable PVST+, use the disable command. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Usage Information After you enable PVST+, the device runs an STP instance for each VLAN it supports. Related Commands disable — disables PVST+. show spanning-tree pvst — displays the PVST+ configuration. show spanning-tree pvst View the Per-VLAN spanning tree configuration. S4820T Syntax Parameters show spanning-tree pvst [vlan vlan-id] [brief] [guard] vlan vlan-id (OPTIONAL) Enter the keyword vlan then the VLAN ID. The range is 1 to 4094.
Usage Information Example (Brief) Version Description 9.7(0.0) Introduced on the S6000-ON. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.4.2.1 Support for the optional guard keyword was added on the C-Series, S-Series, and E-Series TeraScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.
128.147 Interface Name Role PortID Prio Cost Sts Cost Link-type Edge ----------------------------------------------------Te 1/0 Root 128.130 128 20000 FWD 20000 P2P No Te 1/1 Altr 128.131 128 20000 BLK 20000 P2P No Te 1/16 Desg 128.146 128 20000 FWD 20000 P2P Yes Te 1/17 Desg 128.147 128 20000 FWD 20000 P2P Yes Example Dell#show spanning-tree pvst vlan 2 VLAN 2 Root Identifier has priority 4096, Address 0001.e805.
TenGigabitEthernet 1/1 of VLAN 2 is LBK_INC discarding Edge port:no (default) port guard :none (default) Link type: point-to-point (auto) bpdu filter:disable (default) Bpdu guard :disable (default) Bpdus sent 152, received 27562 Interface Designated Name PortID Prio Cost Sts Cost Bridge ID PortID ----------------------------------------------------------Te 1/1 128.1223 128 20000 EDS 0 32768 0001.e800.a12b 128.
spanning-tree pvst Configure a PVST+ interface with one of these settings: edge port with optional bridge port data unit (BPDU) guard, port disablement if an error condition occurs, port priority or cost for a VLAN range, loop guard, or root guard.
priority value Enter the keyword priority then the Port priority value in increments of 16. The range is from 0 to 240. The default is 128. loopguard (C-, S-, and E-Series TeraScale only) Enter the keyword loopguard to enable loop guard on a PVST+ port or portchannel interface. rootguard (C-, S-, and E-Series TeraScale only) Enter the keyword rootguard to enable root guard on a PVST+ port or portchannel interface. Defaults Not configured.
NOTE: A port configured as an edge port, on a PVST switch, immediately transitions to the forwarding state. Only ports connected to end-hosts should be configured as an edge port. Consider an edge port similar to a port with a spanning-tree portfast enabled. If you do not enable shutdown-on-violation, BPDUs are still sent to the route process module (RPM) CPU. You cannot enable root guard and loop guard at the same time on a port.
spanning-tree pvst err-disable Place ports in an Err-Disabled state if they receive a PVST+ BPDU when they are members an untagged VLAN. S4820T Syntax spanning-tree pvst err-disable cause invalid-pvst-bpdu Defaults Enabled; ports are placed in the Err-Disabled state if they receive a PVST+ BPDU when they are members of an untagged VLAN. Command Modes INTERFACE Command History This guide is platform-specific.
tc-flush-standard Enable the MAC address flushing after receiving every topology change notification. S4820T Syntax tc-flush-standard To disable, use the no tc-flush-standard command. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
vlan bridge-priority Set the PVST+ bridge-priority for a VLAN or a set of VLANs. S4820T Syntax vlan vlan-range bridge-priority value To return to the default value, use the no vlan bridge-priority command. Parameters vlan vlan-range Enter the keyword vlan then the VLAN numbers. The range is from 1 to 4094. bridge-priority value Enter the keywords bridge-priority then the bridge priority value in increments of 4096. The range is from 0 to 61440. The default is 32768.
vlan forward-delay Set the amount of time the interface waits in the Listening state and the Learning state before transitioning to the Forwarding state. S4820T Syntax vlan vlan-range forward-delay seconds To return to the default setting, use the no vlan forward-delay command. Parameters vlan vlan-range Enter the keyword vlan then the VLAN numbers. The range is from 1 to 4094.
show spanning-tree pvst — displays the PVST+ configuration. vlan hello-time Set the time interval between generation of PVST+ 7 BPDUs. S4820T Syntax vlan vlan-range hello-time seconds To return to the default value, use the no vlan hello-time command. Parameters vlan vlan-range Enter the keyword vlan then the VLAN numbers. The range is from 1 to 4094. hello-time seconds Enter the keywords hello-time then the time interval, in seconds, between transmission of BPDUs. The range is from 1 to 10 seconds.
vlan forward-delay — changes the time interval before Dell Networking OS transitions to the forwarding state. vlan max-age — changes the time interval before PVST+ refreshes. show spanning-tree pvst — displays the PVST+ configuration. vlan max-age To maintain configuration information before refreshing that information, set the time interval for the PVST+ bridge. S4820T Syntax vlan vlan-range max-age seconds To return to the default, use the no vlan max-age command.
Related Commands Version Description 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced. vlan bridge-priority — sets the bridge-priority value. vlan forward-delay — changes the time interval before Dell Networking OS transitions to the forwarding state. vlan hello-time — changes the time interval between BPDUs. show spanning-tree pvst — displays the PVST+ configuration.
Quality of Service (QoS) 46 The Dell Networking operating software commands for quality of service (QoS) include traffic conditioning and congestion control. QoS commands are not universally supported on all Dell Networking Products. S4820T platform. This chapter contains the following sections: • Global Configuration Commands • Per-Port QoS Commands • Policy-Based QoS Commands Global Configuration Commands There is only one global configuration QoS command.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced. Per-Port QoS Commands Per-port QoS (port-based QoS) allows you to define the QoS configuration on a per-physical-port basis. dot1p-priority Assign a value to the IEEE 802.1p bits on the traffic this interface receives. Syntax dot1p-priority priority-value To delete the IEEE 802.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. Version The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.5.1.
Defaults Granularity for commited-rate and peak-rate is Mbps unless you use the kbps option. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.
Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
Command Modes Command History • INTERFACE • CONFIGURATION This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. After you configure a unicast queue as strict-priority, that particular queue, on the entire chassis, is treated as a strict-priority queue.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.1.9.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 6.2.1.1 Introduced on the E-Series. Usage Information The unit of bandwidth percentage is 1%.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.
show qos class-map — views the current class map information. clear qos statistics Clear qos statistics clears statistics from show qos statistics. S4820T Syntax Parameters clear qos statistics interface-name interface-name Enter one of the following keywords: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
To remove the description, use the no description {description} command. Parameters description Enter a description to identify the policies (80 characters maximum). Defaults none Command Modes CONFIGURATION (policy-map-input and policy-map-output; conf-qos-policy-in and conf-qos-policy-out; wred) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
To remove ACL match criteria from a class map, use the no match ip accessgroup access-group-name [set-ip-dscp value | set-color value] command. Parameters access-groupname Enter the ACL name whose contents are used as the match criteria in determining if packets belong to the class the class-map specifies. set-ip-dscp value (OPTIONAL) Enter the keywords set-ip-dscp then the IP DSCP value. The matched traffic is marked with the DSCP value. The range is from 0 to 63.
match ip dscp Use a differentiated services code point (DSCP) value as a match criteria. S4820T Syntax match {ip | ipv6 | ip-any} dscp dscp-list [set-ip-dscp value] To remove a DSCP value as a match criteria, use the no match {ip | ipv6 | ip-any} dscp dscp-list [[multicast] set-ip-dscp value] command. Parameters ip Enter the keyword ip to support IPv4 traffic. ipv6 Enter the keyword ipv6 to support IPv6 traffic. ip-any Enter the keyword ip-any to support IPv4 and IPv6 traffic.
The match ip dscp and match ip precedence commands are mutually exclusive. Up to 64 IP DSCP values can be matched in one match statement. For example, to indicate IP DCSP values 0 1 2 3 4 5 6 7, enter either the match ip dscp 0,1,2,3,4,5,6,7 or match ip dscp 0-7 command. NOTE: Only one of the IP DSCP values must be a successful match criterion, not all of the specified IP DSCP values must match. Related Commands class-map — identifies the class map.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Added support for the ipv6 and ip-any options on the Z9000, S6000, S4820T, S4810, MXL. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. To access this command, enter the class-map command. After the class map is identified, you can configure the match criteria.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Usage Information To access this command, enter the class-map command. After the class map is identified, you can configure the match criteria. Related Commands class-map — identifies the class map. match mac dot1p Configure a match criterion for a class map based on a dot1p value.
match mac vlan Configure a match criterion for a class map based on VLAN ID. S4820T Syntax Parameters match mac vlan number number Enter the VLAN ID. The range is from 1 to 4094. Defaults none Command Modes CLASS-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Parameters qos-policyname Enter the name of the policy map in character format (32 characters maximum). Defaults none Command Modes CONFIGURATION (policy-map-input and policy-map-output) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.
Defaults Layer 3 Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Usage Information To assign traffic to different flows using QoS policy, use the Output Policy map. This command enables Policy-Map-Output Configuration mode (conf-policymap-out). Related Commands service-queue — assigns a class map and QoS policy to different queues.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Use this command to specify the name of the input QoS policy. Once input policy is specified, rate-police can be defined. This command enables the qos-policyinput configuration mode— (conf-qos-policy-in).
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Usage Information Use this command to specify the name of the output QoS policy. Once output policy is specified, rate-shape, scheduler strict, bandwidth-percentage, and WRED can be defined. This command enables the qos-policy-output configuration mode —(conf-qos-policy-out). Related Commands bandwidth-percentage — assigns percentage of bandwidth to the class/queue.
Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.8.10 Introduced on the S4810. 7.5.1.0 Added support for multicast-bandwidth. 7.4.1.0 and 6.5.3.0 Introduced on the E-Series.
Parameters linecard number Enter the keyword linecard then the line card slot number. port-set number Enter the keywords port-set then the line card’s port pipe. The range is from 0 or 1. all Enter the keyword all to apply to all line cards. wred-profile name (OPTIONAL) Enter the keywords wred-profile then your WRED profile name in character format (16 character maximum). Or use one of the pre-defined WRED profile names.
Parameters kbps Enter the keyword kbps to specify the rate limit in Kilobits per second (Kbps). Make the following value a multiple of 64. The range is from 0 to 40000000. The default granularity is Megabits per second (Mbps). committedrate Enter the bandwidth in Mbps. The range is from 0 to 40000. burst-KB (OPTIONAL) Enter the burst size in KB. The range is from 16 to 200000. The default is 100. peak peak-rate (OPTIONAL) Enter the keyword peak then a number to specify the peak rate in Mbps.
Parameters kbps Enter the keyword kbps to specify the rate limit in Kilobits per second (Kbps). Make the following value a multiple of 64. The range is from 0 to 40000000. The default granularity is Megabits per second (Mbps). rate The range is from 10 to 40000. burst-KB (OPTIONAL) Enter the burst size in KB. The range is from 0 to 40000. The default is 100. Defaults Burst size is 10KB. Granularity for rate is Mbps unless you use the kbps option.
layer2 (OPTIONAL) Enter the keyword layer2 to specify a Layer 2 Class Map. The default is Layer 3. Defaults Layer 3 Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000.
Defaults none Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
assigned to the queue under policy-map-input and output QoS policy under policy-map-output context. Defaults none Command Modes CONFIGURATION (conf-policy-map-in and conf-policy-map-out) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
Class-map match-any CM Match ip access-group ACL Related Commands class-map — identifies the class map. show qos dot1p-queue-mapping Displays the dot1p priority to queue mapping on the switch. Syntax Defaults show qos dot1p-queue-mapping • • Dot1p Priority : 0 1 2 3 4 5 6 7 Queue : 0 0 0 1 2 3 3 3 Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
• detail For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. To view a policy map interface in detail, enter the keyword detail and optionally one of the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
2 3 Dell# Example (Summary IPv4) c2 c3 q2 q3 Dell#sho qos policy-map summary Interface policy-map-input policy-map-output Te 4/1 PM1 Te 4/2 PM2 PMOut Dell# show qos policy-map-input View the input QoS policy map details. S4820T Syntax Parameters show qos policy-map-input [policy-map-name] [class class-mapname] [qos-policy-input qos-policy-name] policy-mapname Enter the policy map name. class classmap-name Enter the keyword class then the class map name.
Policy-map-input PolicyMapInput Aggregate Qos-policy-name AggPolicyIn Queue# Class-map-name Qos-policy-name 0 ClassMap1 qosPolicyInput Dell# show qos policy-map-output View the output QoS policy map details. S4820T Syntax Parameters show qos policy-map-output [policy-map-name] [qos-policy-output qos-policy-name] policy-mapname Enter the policy map name. qos-policyoutput qospolicy-name Enter the keyword qos-policy-output then the QoS policy name.
show qos qos-policy-input View the input QoS policy details. S4820T Syntax Parameters show qos qos-policy-input [qos-policy-name] qos-policyname Enter the QoS policy name. Defaults none Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Parameters qos-policyname Enter the QoS policy name. Defaults none Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.
wred-profile interface interface Enter the keywords wred-profile and optionally one of the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
Parameters wred-profilename Enter the WRED profile name to view the profile details. Defaults none Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
port-set portpipe number Enter the keywords port-set then the stack-unit port pipe number. The range is from 0 or 1. stack-unit all (OPTIONAL) Enter the keywords stack-unit all to indicate all stack-unit. Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Field Description Estimated CAM per Port Indicates the number of free CAM entries required (for the classification rules) to apply the input policy map on a single interface. NOTE: The CAM entries for the default rule are not included in this column; a CAM entry for the default rule is always dedicated to a port and is always available for that interface.
To remove the threshold values, use the no threshold min number max number command. Parameters min number Enter the keyword min then the minimum threshold number for the WRED profile. The range is from 1 to 9360. max-dropprobability number Enter the keyword max-drop-probability followed by the maximum number of packets for the WRED profile. The range is from 0 to 100 KB Defaults none Command Modes CONFIGURATION (config-wred) Command History This guide is platform-specific.
trust Specify dynamic classification (DSCP) or dot1p to trust. S4820T Syntax Parameters trust {diffserv [fallback]| dot1p [fallback]} diffserv Enter the keyword diffserv to specify trust of DSCP markings. dot1p Enter the keyword dot1p to specify trust dot1p configuration. fallback Enter the keyword fallback to classify packets according to their DSCP or dot1p value as a secondary option in case no match occurs against the configured class maps.
DSCP/CP hex Range (XXX) DSCP Definition Traditional IP Precedenc e S6000 Internal Queue ID S-Series Internal Queue ID DSCP/CP Decimal 111XXX Network Control 7 3 48–63 110XXX Internetwo rk Control 6 3 48–63 101XXX EF (Expedited Forwarding ) CRITIC/EC P 5 2 32–47 100XXX AF4 (Assured Forwarding ) Flash Override 4 2 32–47 011XXX AF3 Flash 3 1 16–31 010XXX AF2 Immediate 2 1 16–31 001XXX AF1 Priority 1 0 0–15 000XXX BE (Best Effort) Best Effort 0 0 0–15 wred Des
Defaults When WRED green is applied, default WRED yellow profiles take effect and viceversa. Command Modes CONFIGURATION (conf-qos-policy-out) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820t. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. When you enable wred ecn, and the number of packets in the queue is below the minimum threshold, packets are transmitted per the usual WRED treatment.
Defaults The five pre-defined WRED profiles. When you configure a new profile, the minimum and maximum threshold defaults to predefined wred_ge_g values. If green profile is applied, default yellow also take effect and vice-versa. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Parameters Yellow Enter the yellow keyword. Traffic marked as yellow delivers traffic to the egress queue which either transmits the packet if it has available bandwidth or drops the packet due to no ability to send. Red Enter the red keyword. Traffic marked as red is dropped. dscp-list Enter a list of IP DSCP values. The dscp-list parameter specifies the full list of IP DSCP value(s) for the specified color.
qos dscp-color-policy— configures a DSCP color policy qos dscp-color-map Configure the DSCP color map. Syntax qos dscp-color-map map-name To remove a color map, use the no qos dscp-color-map map-name command. Parameters map-name Enter the name of the DSCP color map. The map name can have a maximum of 32 characters. Defaults None Command Modes CONFIGURATION Command History This guide is platform-specific.
qos dscp-color-policy Associates the DSCP color map profile with an interface so that all IP packets received on it is given a color based on that color map. Syntax dscp-color-policy color-map-profile-name To remove a color policy map profile, use the no dscp-color-policy colormap-profile-name command. Parameters color-mapprofile-name Enter the color map profile name. The name can have a maximum of 32 characters.
show qos dscp-color-policy Display DSCP color policy configuration for one or all interfaces. Syntax Parameters show qos dscp-color-policy {summary [interface] | detail {interface}} summary Enter the summary keyword to display summary information about a color policy on one or more interfaces. Detail Enter the detail keyword to display detailed information about a color policy on one or more interfaces. interface Enter the name of the interface that has color policy configured.
Dscp-color-map mapONE yellow 4,7 red 20,30 Related Commands — Displays DSCP color maps show qos dscp-color-map show qos dscp-color-map Display the DSCP color map for one or all interfaces. Syntax Parameters show qos dscp-color-map map-name map-name Enter the name of the color map. Defaults None Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Routing Information Protocol (RIP) 47 Routing information protocol (RIP) is a distance vector routing protocol. The Dell Networking operating software supports both RIP version 1 (RIPv1) and RIP version 2 (RIPv2) on the S4820T platform. The Dell Networking OS implementation of RIP is based on IETF RFCs 2453 and RFC 1058. For more information about configuring RIP, refer to the Dell Networking OS Configuration Guide.
clear ip rip Update all the RIP routes in the Dell Networking OS routing table. S4820T Syntax clear ip rip Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.
• For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Port Channel interface, enter the keywords portchannel then a number. The range is from 1 to 128. • For a VLAN, enter the keyword vlan then a number from 1 to 4094. database (OPTIONAL) Enter the keyword database to display messages when there is a change to the RIP database.
default-information originate Generate a default route for the RIP traffic. S4820T Syntax default-information originate [always] [metric metric-value] [route-map map-name] To return to the default values, use the no default-information originate command. Parameters always (OPTIONAL) Enter the keyword always to enable the switch software to always advertise the default route. metric metricvalue (OPTIONAL) Enter the keyword metric then a number as the metric value. The range is from 1 to 16.
default-metric Change the default metric for routes. To ensure that all redistributed routes use the same metric value, use this command with the redistribute command. S4820T Syntax default-metric number To return the default metric to the original values, use the no default-metric command. Parameters number Specify a number. The range is from 1 to 16. The default is 1. Defaults 1 Command Modes ROUTER RIP Command History This guide is platform-specific.
description Enter a description of the RIP routing protocol. S4820T Syntax description {description} To remove the description, use the no description {description} command. Parameters description Enter a description to identify the RIP protocol (80 characters maximum). Defaults none Command Modes ROUTER RIP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
distance Assign a weight (for prioritization) to all routes in the RIP routing table or to a specific route. Lower weights (“administrative distance”) are preferred. S4820T Syntax distance weight [ip-address mask [prefix-name]] To return to the default values, use the no distance weight [ip-address mask] command. Parameters weight Enter a number from 1 to 255 for the weight (for prioritization). The default is 120. ip-address (OPTIONAL) Enter the IP address, in dotted decimal format (A.B.C.
distribute-list in Configure a filter for incoming routing updates. S4820T Syntax distribute-list prefix-list-name in [interface] To delete the filter, use the no distribute-list prefix-list-name in command. Parameters prefix-listname Enter the name of a configured prefix list. interface (OPTIONAL) Identifies the interface type slot/port as one of the following: • For a Port Channel interface, enter the keywords portchannel then a number. The range is from 1 to 128.
Related Commands Version Description 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. ip prefix-list — enters PREFIX-LIST mode and configures a prefix list. distribute-list out Configure a filter for outgoing routing updates. S4820T Syntax distribute-list prefix-list-name out [interface | bgp | connected | isis |ospf | static] To delete the filter, use the no distribute-list prefix-list-name out command.
Command Modes ROUTER RIP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.
Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. ip split-horizon — sets the RIP routing updates to exclude routing prefixes. ip rip receive version To receive specific versions of RIP, set the interface.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. Usage Information If you want the interface to receive both versions of RIP, use the ip rip receive version 1 2 command. Related Commands ip rip send version — sets the RIP version for sending RIP traffic on an interface.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. Usage Information To enable the interface to send both version of RIP packets, use the ip rip send version 1 2 command. Related Commands ip rip receive version — sets the RIP version for the interface to receive traffic.
Related Commands Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. ip poison-reverse — sets the prefix for RIP routing updates. maximum-paths Set RIP to forward packets over multiple paths. S4820T Syntax maximum-paths number To return to the default values, use the no maximum-paths commands. Parameters number Enter the number of paths.
Usage Information Version Description 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. RIP supports a maximum of 16 ECMP paths. neighbor Define a neighbor router with which to exchange RIP information. S4820T Syntax neighbor ip-address To delete a neighbor setting, use the no neighbor ip-address command. Parameters ip-address Enter the IP address, in dotted decimal format, of a router with which to exchange information. Defaults Not configured.
Usage Information When a neighbor router is identified, unicast data exchanges occur. Multiple neighbor routers are possible. To ensure that only specific interfaces are receiving and sending data, use the passive-interface command with the neighbor command. Related Commands passive-interface — sets the interface to only listen to RIP broadcasts. network Enable RIP for a specified network. To enable RIP on all networks connected to the switch, use this command.
Usage Information You can enable an unlimited number of RIP networks. RIP operates over interfaces configured with any address the network command specifies. offset-list Specify a number to add to the incoming or outgoing route metrics learned using RIP. S4820T Syntax offset-list prefix-list-name {in | out} offset [interface] To delete an offset list, use the no offset-list prefix-list-name {in | out} offset [interface] command.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. This command is intended for low-speed interfaces. passive-interface Suppress routing updates on a specified interface.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.
metric metricvalue (OPTIONAL) Enter the keyword metric then a number as the metric value. The range is from 0 to 16. route-map map-name (OPTIONAL) Enter the keywords route-map then the name of a configured route map. Defaults Not configured. Command Modes ROUTER RIP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant FTOS Command Line Reference Guide. The following is a list of the FTOS version history for this command.
metric metricvalue (OPTIONAL) Enter the keyword metric then a number as the metric value. The range is from 0 to 16. route-map map-name (OPTIONAL) Enter the keywords route-map then the name of a configured route map. Defaults Not configured. Command Modes ROUTER RIP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. Usage Information To enable RIP, assign a network address using the network command. Example Dell(conf)#router rip Dell(conf-router_rip)# Related Commands network — enables RIP.
Example Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. Dell(conf-router_rip)#show config ! router rip network 172.31.0.0 passive-interface TenGigabitEthernet 1/1 Dell(conf-router_rip)# show ip rip database Display the routes that RIP learns. If the switch learned no RIP routes, no output is generated.
Usage Information Example 1536 Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. The following describes the show ip rip database command shown in the following example. Field Description Total number of routes in RIP database Displays the number of RIP routes stored in the RIP database. 100.10.10.0/24 directly connected Lists the routes directly connected. 150.100.0.
show running-config rip Display the current RIP configuration. S4820T Syntax show running-config rip Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.
timers basic Manipulate the RIP timers for routing updates, invalid, holddown times, and flush time. S4820T Syntax timers basic update invalid holddown flush To return to the default settings, use the no timers basic command. Parameters Defaults update Enter the number of seconds to specify the rate at which RIP routing updates are sent. The range is from zero (0) to 4294967295. The default is 30 seconds.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. If you change the timers on one router, also synchronize the timers on all routers in the RIP domain. version Specify either RIP version 1 or RIP version 2.
Related Commands Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. ip rip receive version — sets the RIP version the interface receives. ip rip send version — sets the RIP version the interface sends.
Remote Monitoring (RMON) 48 The Dell Networking operating software remote monitoring (RMON) is implemented on the S4820T platform. Dell Networking OS RMON is based on IEEE standards, providing both 32-bit and 64-bit monitoring and long-term statistics collection.
To disable the alarm, use the no rmon alarm number command. Parameters number Enter the alarm integer number from 1 to 65535. The value must be unique in the RMON alarm table. variable Enter the MIB object to monitor. The variable must be in the SNMP OID format; for example, 1.3.6.1.2.1.1.3. The object type must be a 32-bit integer. interval Time, in seconds, the alarm monitors the MIB variables; this is the alarmSampleType in the RMON alarm table. The range is from 5 to 3600 seconds.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. rmon collection history Enable the RMON MIB history group of statistics collection on an interface.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. rmon event Add an event in the RMON event table.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
absolute Enter the keyword absolute to test each MIB variable directly. This is the alarmSampleType in the RMON alarm table. risingthreshold value event-number Enter the keywords rising-threshold then the value (64 bit) the rising-threshold alarm is either triggered or reset. Then enter the event-number to trigger when the rising threshold exceeds its limit. This value is the same as the alarmRisingEventIndex or alarmTable of the RMON MIB.
show rmon Display the RMON running status including the memory usage. S4820T Syntax show rmon Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example 1548 Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
show rmon alarms Display the contents of the RMON alarm table. S4820T Syntax Parameters show rmon alarms [index] [brief] index (OPTIONAL) Enter the table index number to display just that entry. brief (OPTIONAL) Enter the keyword brief to display the RMON alarm table in an easy-to-read format. Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
-------------------------1 1.3.6.1.2.1.1.3 2 1.3.6.1.2.1.1.3 3 1.3.6.1.2.1.1.3 4 1.3.6.1.2.1.1.3 5 1.3.6.1.2.1.1.3 6 1.3.6.1.2.1.1.3 7 1.3.6.1.2.1.1.3 8 1.3.6.1.2.1.1.3 9 1.3.6.1.2.1.1.3 10 1.3.6.1.2.1.1.3 11 1.3.6.1.2.1.1.3 12 1.3.6.1.2.1.1.3 13 1.3.6.1.2.1.1.3 14 1.3.6.1.2.1.1.3 15 1.3.6.1.2.1.1.3 16 1.3.6.1.2.1.1.3 17 1.3.6.1.2.1.1.3 18 1.3.6.1.2.1.1.3 19 1.3.6.1.2.1.1.3 20 1.3.6.1.2.1.1.3 21 1.3.6.1.2.1.1.3 22 1.3.6.1.2.1.1.3 Dell# show rmon events Display the contents of the RMON event table.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series.
10 11 12 13 14 15 16 17 18 19 20 21 22 Dell# 10 11 12 13 14 15 16 17 18 19 20 21 22 show rmon hc-alarm Display the contents of RMON High-Capacity alarm table. S4820T Syntax Parameters show rmon hc-alarm [index] [brief] index (OPTIONAL) Enter the table index number to display just that entry. brief (OPTIONAL) Enter the keyword brief to display the RMON High-Capacity alarm table in an easy-to-read format. Defaults none Command Modes EXEC Command History This guide is platform-specific.
Version Description 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. Example (Index) Dell#show rmon hc-alarm 1 RMON high-capacity alarm entry 2 object: 1.3.6.1.2.1.2.2.1.4.2099844 sample interval: 10 sample type: delta value. value: 0, value status: positive alarm type: rising or falling alarm. alarm rising threshold value: positive. rising threshold: 500, RMON event index: 3 alarm falling threshold value: positive.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
show rmon log Display the contents of the RMON log table. S4820T Syntax Parameters show rmon log [index] [brief] index (OPTIONAL) Enter the table index number to display just that entry. brief (OPTIONAL) Enter the keyword brief to display the RMON log table in an easy-to-read format. Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
4 Dell# 4 show rmon statistics Display the contents of RMON Ethernet statistics table. S4820T Syntax Parameters show rmon statistics [index] [brief] index (OPTIONAL) Enter the table index number to display just that entry. brief (OPTIONAL) Enter the keyword brief to display the RMON Ethernet statistics table in an easy-to-read format. Defaults none Command Modes EXEC Command History This guide is platform-specific.
CRC error: 0 under-size packets: 0 over-size packets: 0 fragment errors: 0 jabber errors: 0 collision: 0 64bytes packets: 0 65-127 bytes packets: 0 128-255 bytes packets: 0 256-511 bytes packets: 0 512-1023 bytes packets: 0 1024-1518 bytes packets: 0 owner: 1 status: OK HC packets received overflow: 0 HC packets received: 0 HC bytes received overflow: 0 HC bytes received: 0 HC 64bytes packets overflow: 0 HC 64bytes packets: 0 HC 65-127 bytes packets overflow: 0 HC 65-127 bytes packets:
Rapid Spanning Tree Protocol (RSTP) 49 The Dell Networking operating software implementation of rapid spanning tree protocol (RSTP) is based on the IEEE 802.1w standard spanning-tree protocol. The RSTP algorithm configures connectivity throughout a bridged local area network (LAN) that is comprised of LANs interconnected by bridges. Dell Networking OS supports RSTP. bridge-priority Set the bridge priority for RSTP.
Related Commands Version Description 6.2.1.1 Introduced on the E-Series. protocol spanning-tree rstp — enters rapid spanning tree mode. debug spanning-tree rstp Enable debugging of RSTP and view information on the protocol. Syntax debug spanning-tree rstp [all | bpdu interface {in | out} | events] To disable debugging, use the no debug spanning-tree rstp command. Parameters all (OPTIONAL) Enter the keyword all to debug all spanning tree operations.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series.
Related Commands Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. pre-7.7.1.0 Introduced. protocol spanning-tree rstp — enters SPANNING TREE mode on the switch. disable Disable RSTP globally on the system. Syntax disable To enable Rapid Spanning Tree Protocol, use the no disable command. Defaults RSTP is disabled. Command Modes CONFIGURATION RSTP (conf-rstp) Command History This guide is platform-specific.
forward-delay Configure the amount of time the interface waits in the Listening State and the Learning State before transitioning to the Forwarding State. Syntax forward-delay seconds To return to the default setting, use the no forward-delay command. Parameters seconds Enter the number of seconds that Dell Networking OS waits before transitioning RSTP to the forwarding state. The range is from 4 to 30. The default is 15 seconds.
hello-time Set the time interval between the generation of the RSTP bridge protocol data units (BPDUs). Syntax hello-time [milli-second] seconds To return to the default value, use the no hello-time command. Parameters seconds Enter a number as the time interval between transmission of BPDUs. The range is from 1 to 10 seconds. The default is 2 seconds. milli-second Enter the keywords milli-second to configure a hello time on the order of milliseconds.
Related Commands forward-delay — changes the wait time before RSTP transitions to the Forwarding state. max-age — changes the wait time before RSTP refreshes the protocol configuration information. max-age To maintain configuration information before refreshing that information, set the time interval for the RSTP bridge. Syntax max-age seconds To return to the default values, use the no max-age command.
hello-time — changes the time interval between BPDUs. protocol spanning-tree rstp To configure RSTP, enter RSTP mode. Syntax protocol spanning-tree rstp To exit RSTP mode, use the exit command. Defaults Not configured Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
show config View the current configuration for the mode. Only non-default values are displayed. Syntax show config Command Modes CONFIGURATION RSTP (conf-rstp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Command Modes Command History Usage Information Example (Brief) • • EXEC EXEC Privilege Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.4.2.1 Added support for the optional guard keyword on the CSeries, S-Series, and E-Series TeraScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.4.1.
Te 4/1 Desg 128.419 128 20000 FWD 20000 P2P Te 4/8 Root 128.426 128 20000 FWD 20000 P2P Te 4/9 Altr 128.427 128 20000 BLK 20000 P2P Dell# Example (EDS, LBK) Yes No No NOTE: “LBK_INC” (bold) means Loopback BPDU Inconsistency. Dell#show spanning-tree rstp br Executing IEEE compatible Spanning Tree Protocol Root ID Priority 32768, Address 0001.e801.6aa8 Root Bridge hello time 2, max age 20, forward delay 15 Bridge ID Priority 32768, Address 0001.e801.
spanning-tree rstp Configure an RSTP interface with one of these settings: port cost, edge port with optional bridge port data unit (BPDU) guard, port priority, loop guard, or root guard. Syntax Parameters spanning-tree rstp {cost port-cost | edge-port [bpduguard [shutdown-on-violation]] | priority priority | {loopguard | rootguard}} cost port-cost Enter the keyword cost then the port cost value. The range is from 1 to 200000.
Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.4.2.
Example • If a BPDU is received from a remote device, BPDU guard places the port in an Err-Disabled Blocking state and no traffic is forwarded on the port. • If no BPDU is received from a remote device, loop guard places the port in a Loop-Inconsistent Blocking state and no traffic is forwarded on the port.
Usage Information 1572 By default, Dell Networking OS implements an optimized flush mechanism for RSTP. This implementation helps in flushing MAC addresses only when necessary (and less often), allowing for faster convergence during topology changes. However, if a standards-based flush mechanism is needed, you can turn on this knob command to enable flushing MAC addresses after receiving every topology change notification.
Software-Defined Networking (SDN) 50 Dell Networking operating software supports Software-Defined Networking (SDN). For more information, refer to the SDN Deployment Guide.
51 Security The commands in this chapter are available on Dell Networking OS. This chapter contains various types of security commands offered in the Dell Networking operating software. The commands are listed in the following sections: • AAA Accounting Commands • Authorization and Privilege Commands • Authentication and Password Commands • RADIUS Commands • TACACS+ Commands • Port Authentication (802.
To disable AAA Accounting, use the no aaa accounting {system | exec | command level} {name | default}{start-stop | wait-start | stoponly} {tacacs+} command. Parameters system Enter the keyword system to send accounting information of any other AAA configuration. exec Enter the keyword exec to send accounting information when a user has logged in to EXEC mode.
Usage Information Version Description 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.3.1.0 Introduced on the E-Series. In the example above, TACACS+ accounting is used to track all usage of EXEC command and commands on privilege level 15. Privilege level 15 is the default.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4280T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.3.1.0 Introduced on the E-Series.
The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.5(0.0) Added support for roles on the Z9000, S6000, S4820T, S4810, MXL. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.3.1.
Version Description 7.5.1.0 Introduced on the C-Series. 6.3.1.0 Introduced on the E-Series. Usage Information This command steps through all active sessions and then displays the accounting records for the active account functions.
method-list Enter a method list that you defined using the aaa accounting exec or aaa accounting commands. Defaults none Command Modes LINE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.5(0.
Parameters commands level Enter the keyword commands then the command privilege level for command level authorization. role role-name Enter the keyword role then the role name. name Define a name for the list of authorization methods. default Define the default list of authorization methods. local Use the authorization parameters on the system to perform authorization. tacacs+ Use the TACACS+ protocol to perform authorization. none Enter the keyword none to apply no authorization.
Defaults Enabled when you configure aaa authorization commands command. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
command Enter the command’s keywords to assign the command to a certain access level. You can enter one or all of the keywords. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
Command Modes LINE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.6(0.0) Introduced on the S4810, S4820T, S5000, S6000, Z9000, Z9500, MXL By default, the service password-encryption command stores encrypted passwords. For greater security, you can also use the service obscurepasswords command to prevent a user from reading the passwords and keys, including RADIUS, TACACS+ keys, router authentication strings, VRRP authentication by obscuring this information.
To return to the default setting, use the no aaa authentication enable {default | method-list-name} method [... method2] command. Parameters default Enter the keyword default then the authentication methods to use as the default sequence of methods for the Enable login. The default is default enable. method-listname Enter a text string (up to 16 characters long) to name the list of enabled authentication methods activated at login. method Enter one of the following methods: ...
Usage Information By default, the Enable password is used. If you configure aaa authentication enable default, Dell Networking OS uses the methods defined for Enable access instead. Methods configured with the aaa authentication enable command are evaluated in the order they are configured. If authentication fails using the primary method, Dell Networking OS employs the second method (or third method, if necessary) automatically.
... method4 • none: no authentication. Not available if role-only is in use. • radius: use the RADIUS servers configured with the radius-server host command. • tacacs+: use the TACACS+ servers configured with the tacacs-server host command. (OPTIONAL) Enter up to four additional methods. In the event of a “no response” from the first method, the system applies the next configured method (up to four configured methods). Defaults Not configured (that is, no authentication is performed).
NOTE: If authentication fails using the primary method, Dell Networking OS employs the second method (or third method, if necessary) automatically. For example, if the TACACS+ server is reachable, but the server key is invalid, Dell Networking OS proceeds to the next authentication method. The TACACS+ is incorrect, but the user is still authenticated by the secondary method.
Related Commands Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. line — applies an authentication method list to the designated terminal lines. ip access-list standard — names (or selects) a standard access list to filter based on the IP address. ip access-list extended — names (or selects) an extended access list based on the IP addresses or protocols.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. To control access to command modes, use this command to define a password for a level and use the privilege level (CONFIGURATION mode) command.
Use this parameter only with a password that you copied from the show running-config file of another Dell Networking router. password Enter a text string, up to 32 characters long, as the clear text password. Defaults Not configured. Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Use this parameter only with a password that you copied from the show running-config file of another Dell Networking router. password Enter a text string, up to 32 characters long, as the clear text password. Defaults No password is configured. level = 15. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
login authentication To configure authentication for console or remote access, apply an authentication method list. Syntax login authentication {method-list-name | default} To use the local user/password database for login authentication, use the no login authentication command. Parameters method-listname Enter the keywords method-list-name to specify that method list, created in the aaa authentication login command, to be applied to the designated terminal line.
Related Commands • If you configure an authentication lists other than default, you must apply those authentication lists to each connection. • If you configure the aaa authentication login default command, the login authentication default command automatically is applied to all terminal lines. aaa authentication login — selects the login authentication methods. password Specify a password for users on terminal lines.
Version Description pre-6.1.1.0 Introduced on the E-Series. Usage Information Dell Networking OS prompts users for these passwords when the method for authentication or authorization used is "line". Related Commands enable password — sets the password for the enable command. login authentication — configures an authentication method to log in to the switch. service password-encryption — encrypts all passwords configured in Dell Networking OS .
characterrestriction (OPTIONAL) Enter the keywords character-restriction to indicate a character restriction for the password. upper number (OPTIONAL) Enter the keyword upper then the upper number. The range is from 0 to 31. lower number (OPTIONAL) Enter the keyword lower then the lower number. The range is from 0 to 31. numeric number (OPTIONAL) Enter the keyword numeric then the numeric number. The range is from 0 to 31.
service password-encryption Encrypt all passwords configured in Dell Networking OS. Syntax service password-encryption To store new passwords as clear text, use the no service passwordencryption command. Defaults Enabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
show privilege View your access level. Syntax show privilege Command Modes • • Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. EXEC EXEC Privilege The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Security Version Description 9.7(0.0) Introduced on the S6000–ON. 9.5(0.0) Added support for roles on the Z9000, S6000, S4820T, S4810, MXL. 9.2(1.0) Introduced on the Z9500. 9.0.2.
unassigned 7 vty 5 unassigned Dell# Related Commands 1 15 idle ad idle 10.16.127.141 10.16.127.141 username — enables a user. timeout login response Specify how long the software waits for the login input (for example, the user name and password) before timing out. Syntax timeout login response seconds To return to the default values, use the no timeout login response command. Parameters seconds Enter a number of seconds the software waits before logging you out.
Usage Information Version Description pre-6.1.1.0 Introduced on the E-Series. The software measures the period of inactivity defined in this command as the period between consecutive keystrokes. For example, if your password is “password” you can enter “p” and wait 29 seconds to enter the next letter. username Establish an authentication system based on user names.
role role-name Enter the keyword role followed by the role name to associate with that user ID. secret Enter the keyword secret then the encryption type. Defaults The default encryption type for password option is 0. The default encryption type for secret option is 0. The default value of privilege level is 1. Command Modes CONFIGURATION Command History This guide is platform-specific.
RADIUS Commands The following RADIUS commands are supported by Dell Networking OS. aaa radius group Configure the RADIUS server group that is used for Authentication, Authorization and Accounting. Syntax aaa radius group group-name To remove the RADIUS group configuration, use the no aaa radius group group-name command. Parameters group-name Enter the name of the RADIUS server group. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific.
Defaults Disabled. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.
Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.
Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. radius-server group Creates or deletes a group of radius servers. Syntax Parameters radius-server group group-name group-name Enter the group name that denotes the group of RADIUS servers.
Related Commands login authentication — sets the database to be checked when a user logs in. radius-server key — sets an authentication key for RADIUS communications. radius-server retransmit — sets the number of times the RADIUS server attempts to send information. radius-server timeout — sets the time interval before the RADIUS server times out. radius-server host Configure a RADIUS server host.
Defaults Not configured. Command Modes • RADIUS SERVER GROUP • CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
VRF. The order in which the RADIUS servers are tried depends on the order in which the RADIUS servers are configured. Example Dell(conf)#radius-server group group1 Dell(conf-radius-group)#radius-server host 1.1.1.1 key secret Dell(conf-radius-group)#no radius-server host 1.1.1.1 Related Commands login authentication — sets the database to be checked when a user logs in. radius-server key — sets an authentication key for RADIUS communications.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Authentication key length increased to 42 characters. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.0 Introduced on the E-Series. The key configured on the switch must match the key configured on the RADIUS server daemon.
Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.0 Introduced on the E-Series. radius-server host — configures a RADIUS host.
Related Commands Version Description 7.5.1.0 Introduced on the C-Series. pre-6.2.1.0 Introduced on the E-Series. radius-server host — configures a RADIUS host. radius-server vrf Create an association between a RADIUS server group and a VRF and source interface. ud Syntax radius-server vrf vrf-name [source-interface interface] To delete the association between a RADIUS server group and a VRF and source interface, use the no radius-server vrf vrf-name [source-interface interface] command.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.4(0.0) Introduced on the S-Series and Z9000. You can use this command to associate a group of RADIUS servers with a VRF and source interface. You can configure the source interface only with the VRF attribute and source interface is optional with the VRF attributes. If VRF is not configured on the RADIUS group, then the group is considered to be on the default VRF.
Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4.(0.0) Introduced on the S-Series and Z-Series.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.0 Introduced on the E-Series. ip tacacs source-interface Specify an interface’s IP address as the source IP address for TACACS+ connections.
Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. tacacs-server group Creates a group of TACACS servers.
tacacs-server vrf vrf1 source-interface TenGigabitEthernet 1/42 tacacs-server host 1.1.1.1 key 7 9a2f3ec0c65c6f41 tacacs-server host 2.2.2.2 key 7 9a2f3ec0c65c6f41 Dell(conf-tacacs-group)# Related Commands aaa authentication login — specifies the login authentication method. tacacs-server key — configures a TACACS+ key for the TACACS server. tacacs-server host Specify a TACACS+ host.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Added support for IPv6. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Authentication key length increased to 42 characters. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. To list multiple TACACS+ servers to be used by the aaa authentication login command, configure this command multiple times.
To delete the association between a TACACS server group and a VRF and source interface, use the no tacacs-server vrf vrf-name [source-interface interface] command. Parameters vrf vrf-name Enter the keyword vrf and then the name of the VRF to associate a TACACS server group with that VRF. interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Example Dell(conf)#tacacs-server group group1 Dell(conf-tacacs-group)#tacacs-server vrf vrf1 sourceinterface tengigabitethernet 1/36 Dell(conf)#tacacs-server group group2 Dell(conf-tacacs-group)#tacacs-server vrf default tacacs-server key Configure a key for communication between a TACACS+ server and a client. Syntax tacacs-server key [encryption-type] key To delete a key, use the no tacacs-server key key command.
Usage Information The key configured with this command must match the key configured on the TACACS+ daemon. Port Authentication (802.1X) Commands An authentication server must authenticate a client connected to an 802.1X switch port. Until the authentication, only Extensible Authentication Protocol over LAN (EAPOL) traffic is allowed through the port to which a client is connected. After authentication is successful, normal traffic passes through the port.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Related Commands Version Description 7.4.1.0 Introduced on the E-Series. dot1x authentication (Configuration) — enables dot1x globally. dot1x auth-fail-vlan Configure an authentication failure VLAN for users and devices that fail 802.1X authentication. Syntax dot1x auth-fail-vlan vlan-id [max-attempts number] To delete the authentication failure VLAN, use the no dot1x auth-fail-vlan vlan-id [max-attempts number] command. Parameters vlan-id Enter the VLAN Identifier. The range is from 1 to 4094.
Related Commands dot1x port-control — enables port-control on an interface. dot1x guest-vlan — configures a guest VLAN for non-dot1x devices. show dot1x interface — displays the 802.1X information on an interface. dot1x auth-server Configure the authentication server to RADIUS. Syntax dot1x auth-server radius Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.4 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.4.1.
Related Commands Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. interface range — configures a range of interfaces. dot1x port-control Enable port control on an interface. Syntax Parameters dot1x port-control {force-authorized | auto | forceunauthorized} forceauthorized Enter the keywords force-authorized to forcibly authorize a port.
Usage Information The authenticator performs authentication only when port-control is set to auto. dot1x quiet-period Set the number of seconds that the authenticator remains quiet after a failed authentication with a client. Syntax dot1x quiet-period seconds To disable quiet time, use the no dot1x quiet-time command. Parameters seconds Enter the number of seconds. The range is from 1 to 65535. The default is 30.
Defaults 3600 seconds (1 hour) Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x server-timeout Configure the amount of time after which exchanges with the server time-out. Syntax dot1x server-timeout seconds To return to the default, use the no dot1x server-timeout command. Parameters seconds Enter a time-out value in seconds.
dot1x supplicant-timeout Configure the amount of time after which exchanges with the supplicant time-out. Syntax dot1x supplicant-timeout seconds To return to the default, use theno dot1x supplicant-timeout command. Parameters seconds Enter a time-out value in seconds. The range is from 1 to 300, where 300 is implementation dependant. The default is 30. Defaults 30 seconds Command Modes INTERFACE Command History This guide is platform-specific.
Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Example Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series, S-Series, and E-Series. Dell#show dot1x interface fortyGigE 1/48 802.
Supplicant Timeout: Server Timeout: Re-Auth Interval: Max-EAP-Req: Host Mode: Auth PAE State: Backend State: Dell# 30 seconds 30 seconds 3600 seconds 2 SINGLE_HOST Initialize Initialize SSH Server and SCP Commands Dell Networking OS supports secure shell (SSH) protocol versions 1.5 and 2.0. SSH is a protocol for secure remote login over an insecure network. SSH sessions are encrypted and use authentication. The SSH server and client are enhanced to support the VRF awareness functionality.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Added support for FIPS mode on the S4810. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series.
crypto key zeroize rsa Removes the generated RSA host keys and zeroize the key storage location. Syntax crypto key zeroize rsa Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.5(0.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Debug information includes details for key-exchange, authentication, and established session for each connection. ip scp topdir Identify a location for files used in secure copy transfer.
Usage Information To configure the switch as an SCP server, use the ip ssh server command. Related Commands ip ssh server — enables the SSH and SCP server on the switch. ip ssh authentication-retries Configure the maximum number of attempts that should be used to authenticate a user. Syntax Parameters ip ssh authentication-retries 1-10 1-10 Enter the number of maximum retries to authenticate a user. The range is from 1 to 10. The default is 3.
Parameters 1-10 Enter the number of maximum numbers of incoming SSH connections allowed per minute. The range is from 1 to 10 per minute. The default is 10 per minute. Defaults 10 per minute Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. If you enable this command, clients can log in without a password prompt.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. The server-generated key is used for SSHv1 key-exchange. ip ssh password-authentication Enable password authentication for the SSH server.
Usage Information Version Description 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. With password authentication enabled, you can authenticate using the local, RADIUS, or TACACS+ password fallback order as configured. ip ssh pub-key-file Specify the file used for host-based authentication. Syntax Parameters ip ssh pub-key-file {WORD} WORD Enter the file name for the host-based authentication.
+DWEc3cgYAcU5Lai1MU2ODrzhCwyDNp05tKBU3t ReG1o8AxLi6+S4hyEMqHzkzBFNVqHzpQc +Rs4p2urzV0F4pRKnaXdHf3Lk4D460HZRhhVrxqeNxPDpEn WIMPJi0ds= ashwani@poclab4 NOTE: For rhostfile and pub-key-file, the administrator must FTP the file to the chassis. Example Dell#conf Dell(conf)# ip ssh pub-key-file flash://knownhosts Dell(conf)# Related Commands show ip ssh client-pub-keys — displays the client-public keys used for the hostbased authentication.
ip ssh rhostsfile Specify the rhost file used for host-based authorization. Syntax Parameters ip ssh rhostsfile {WORD} WORD Enter the rhost file name for the host-based authentication. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.
ip ssh rsa-authentication (Config) Enable RSA authentication for the SSHv2 server. Syntax ip ssh rsa-authentication enable To disable RSA authentication, use the no ip ssh rsa-authentication enable command. Parameters enable Enter the keyword enable to enable RSA authentication for the SSHv2 server. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
To delete a VRF for an outgoing SSH connection, use the no ip ssh vrf vrfname command. Parameters vrf vrf-name Enter the keyword vrf and then the name of the VRF to configure that VRF for an outgoing SSH session. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
• For a port channel interface, enter the keywords portchannel then a number. The range is from 1 to 128. • For a Null interface, enter the keyword null then the Null interface number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Parameters enable Enter the key word enable to start the SSH server. ciphers cipherlist Enter the keyword ciphers and then a space-delimited list of ciphers that the SSH server supports. The following ciphers are available. • 3des-cbc • aes128-cbc • aes192-cbc • aes256-cbc • aes128-ctr • aes192-ctr • aes256-ctr The default cipher list is used.
kex keyexchangealgorithm • hmac-sha1 • hmac-sha1-96 • hmac-sha2-256 • hmac-sha2-256-96 Enter the keyword kex and then a space-delimited list of key exchange algorithms supported by the SSH server. The following key exchange algorithms are available: • diffie-hellman-group-exchange-sha1 • diffie-hellman-group1-sha1 • diffie-hellman-group14-sha1 When FIPS is enabled, the default key-exchange-algorithm is diffie-hellman-group14-sha1.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.5(0.0) Introduced the cipher, kex and mac options on the Z9000, S6000, S4820T, S4810, and MXL. 9.0.2.0 Introduced on the S6000. 8.3.19.
Parameters vrf management Enter the key word vrf followed by the keyword management to configure an SSH server on a management VRF. vrf vrf-name Enter the key word vrf followed by the VRF name to configure an SSH server on that VRF. Defaults None Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Parameters Key Enter the keyword key to display the host public key. mypubkey Enter the keyword mypubkey to display the host public key. rsa Enter the keyword rsa to display the host SSHv2 RSA public key. rsa1 Enter the keyword rsa1 to display the host SSHv1 RSA public key. NOTE: If you enable FIPS mode, this parameter is not available. Defaults none Command Modes EXEC Command History This guide is platform-specific.
Related Commands crypto key generate — generates the SSH keys. show ip ssh Display information about established SSH sessions. Syntax NOTE: Some of the parameters in this command require licensing to access. For more information, contact your Dell Networking representative. show ip ssh Command Modes Command History • • EXEC EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Related Commands ip ssh server — configures an SSH server. show ip ssh client-pub-keys — displays the client-public keys. show ip ssh client-pub-keys Display the client public keys used in host-based authentication. Syntax show ip ssh client-pub-keys Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
+QJkqtyiwDPmH4njyDMYDCXY85vc55ibWsN9qalagklnh2cj2q4nYj5x8+8OOhY eFPaHiygd8U/FXict61jWs84Co1UTsAgRzDJ9aUSS75TVac= Dell# Related Commands ip ssh pub-key-file — configures the filename for the host-based authentication. show ip ssh rsa-authentication Display the authorized-keys for the RSA authentication. Syntax Parameters show ip ssh rsa-authentication {my-authorized-keys} myauthorizedkeys Display the RSA authorized keys.
Dell# Related Commands ip ssh rsa-authentication (Config) — configures the RSA authorized keys. ssh Open an SSH connection specifying the hostname, username, encryption cipher, HMAC algorithm, port number, and version of the SSH client. Syntax NOTE: Some of the parameters in this command require licensing to access. For more information, contact your Dell Networking representative.
"no fips mode enable"(disable) will support v1 & v2 client. This comment is applicable for both ciphers & HMAC algorithms: • 3des-cbc: Force ssh to use 3des-cbc encryption cipher.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.
clear ip dhcp snooping Clear the DHCP binding table. Syntax clear ip dhcp snooping binding Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
Related Commands ip dhcp snooping vlan — enables DHCP Snooping on one or more VLANs. ip dhcp snooping binding Create a static entry in the DHCP binding table. Syntax Parameters [no] ip dhcp snooping binding mac address vlan-id vlan-id ip ip-address interface type slot/port lease number mac address Enter the keyword mac then the MAC address of the host to which the server is leasing the IP address. vlan-id vlan-id Enter the keywords vlan-id then the VLAN to which the host belongs.
Related Commands Version Description 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series. show ip dhcp snooping — displays the contents of the DHCP binding table. ip dhcp snooping database Delay writing the binding table for a specified time. Syntax Parameters ip dhcp snooping database write-delay minutes minutes The range is from 5 to 21600.
Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
ip dhcp source-address-validation Enable IP source guard. Syntax [no] ip dhcp source-address-validation Defaults Disabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series. When enabled, the system begins creating entries in the binding table for the specified VLANs. NOTE: Learning only happens if there is a trusted port in the VLAN. Related Commands ip dhcp snooping trust — configures an interface as trusted.
Role-Based Access Control Commands With Role-Based Access Control (RBAC), access and authorization is controlled based on a user’s role. Users are granted permissions based on their user roles, not on their individual user ID. User roles are created for job functions and through those roles they acquire the permissions to perform their associated job function. This section describes the syntax and usage of RBAC-specific commands.
Usage Information By default, access to commands are determined by the user’s role (if defined) or by the user’s privilege level. If the aaa authorization role-only command is enabled, then only the user’s role is used. Before you enable role-based only AAA authorization: Related Commands 1. Locally define a system administrator user role.This will give you access to login with full permissions even if network connectivity to remote authentication servers is not available. 2.
role-name Enter a text string for the name of the user role up to 63 characters. These are 3 system defined roles you can modify: secadmin, netadmin, and netoperator. reset Enter the keyword reset to reset all roles back to default for that command. command Enter the command’s keywords to assign the command to a certain access level. You can enter one or more keywords. Defaults none Command Modes CONFIGURATION Command History Related Commands Version Description 9.7(0.
Command History Examples Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9000, S6000, S4820T, S4810, MXL Dell#show role mode configure username Role access: sysadmin Dell#show role mode configure management route Role access: netadmin, sysadmin Dell#show role mode configure management crypto-policy Role access: secadmin, sysadmin Related Commands userrole, username, privilege show userroles Display information on all defined user roles.
To delete a role name, use the no userrole name command. Note that the reserved role names may not be deleted. Parameters name Enter a text string for the name of the user up to 63 characters. It cannot be one of the system defined roles (sysadmin, secadmin, netadmin, netoperator). inherit existingrole-name Enter the inherit keyword then specify the system defined role to inherit permissions from (sysadmin, secadmin, netadmin, netoperator).
Service Provider Bridging 52 Service provider bridging is composed of virtual local area network (VLAN) Stacking, Layer 2 Protocol Tunneling, and Provider Backbone Bridging as described in the Dell Networking OS Configuration Guide Service Provider Bridging chapter. This chapter includes command line information (CLI) for the Dell Networking operating software Layer 2 Protocol Tunneling (L2PT). L2PT enables protocols to tunnel through an 802.1q tunnel.
Parameters interface Enter one of the following interfaces and slot/port information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a Port Channel interface, enter the keywords portchannel then a number. The range is from 1 to 128.
protocol-tunnel Enable protocol tunneling on a stacked (Q-in-Q) VLAN for specified protocol packets. Syntax protocol-tunnel {rate-limit rate| stp} To disable protocol tunneling for a Layer 2 protocol, use the no protocoltunnel command. Parameters rate-limit rate Enter the keyword rate-limit followed by a number for the rate-limit for tunneled packets on the VMAN. The range is from 64 to 320. stp Enter the keyword stp to enable protocol tunneling on a spanning tree, including STP, MSTP, RSTP, and PVST.
protocol-tunnel destination-mac Overwrite the BPDU destination MAC address with a specific value. Syntax Parameters protocol-tunnel destination-mac xstp address stp Change the default destination MAC address used for L2PT to another value. Defaults The default destination MAC is 01:01:e8:00:00:00. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.4.1.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series, E-Series TeraScale, and ESeries ExaScale. Maximum rate limit on E-Series reduced from 4000 to 3000. 7.4.1.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series, E-Series and E-Series ExaScale. 7.4.1.
sFlow 53 The Dell Networking operating software (OS) supports sFlow commands on Dell Networking OS. Dell Networking operating software sFlow monitoring system includes an sFlow Agent and an sFlow Collector. • The sFlow Agent combines the flow samples and interface counters into sFlow datagrams and forwards them to the sFlow Collector. • The sFlow Collector analyses the sFlow Datagrams received from the different devices and produces a network-wide view of traffic flows.
sflow collector Configure a collector device to which sFlow datagrams are forwarded. Syntax sflow collector {ip-address | ipv6-address} agent-addr {ipaddress | ipv6-address} [number [max-datagram-size number]] | [max-datagram-size number] [vrf management] To delete a configured collector, use the no sflow collector {ip-address | ipv6-address} agent-addr {ipv4-address | ipv6-address} [number [max-datagram-size number]] | [max-datagram-size number] [vrf management] command.
Usage Information Version Description 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.4.2.3 Added support for IPv6 sFlow collectors and agents on the E-series TeraScale, C-Series, and S-Series. 8.4.1.1 Added support for IPv6 sFlow collectors and agents on the E-series ExaScale. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced S-Series Stacking. 8.1.1.0 Introduced on the E-Series ExaScale. 7.7.1.
sflow enable (Global) Enable sFlow globally. Syntax sflow enable To disable sFlow, use the no sflow enable command. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Defaults Disabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced on the S-Series, Z-Series, and MXL switch.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on S-Series Stacking. 8.1.1.0 Introduced on the E-Series ExaScale. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced on the S Series and Z Series switches. Dell(conf)#sflow max-header-size extended sflow polling-interval (Global) Set the sFlow polling interval at a global level. Syntax sflow polling-interval interval value To return to the default, use the no sflow polling-interval interval command. Parameters interval value Enter the interval value in seconds. The range is from 15 to 86400 seconds. The default is 20 seconds.
Usage Information The polling interval for an interface is the maximum number of seconds between successive samples of counters sent to the collector. This command changes the global default counter polling (20 seconds) interval. You can configure an interface to use a different polling interval. Related Commands sflow polling-interval (Interface) — sets the polling interval for an interface.
Usage Information This command sets the counter polling interval for an interface. Related Commands sflow polling-interval (Global) — globally sets the polling interval. sflow sample-rate (Global) Change the global default sampling rate. Syntax sflow sample-rate value To return to the default sampling rate, use the no sflow sample-rate command. Parameters value Enter the sampling rate value.
Usage Information Sample-rate is the average number of packets skipped before the sample is taken. This command changes the global default sampling rate. You can configure an interface to use a different sampling rate than the global sampling rate. If the value entered is not a correct power of 2, the command generates an error message with the previous and next power of 2 value. Select one of these two packet numbers and re-enter the command.
Version Description 7.6.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. Usage Information This command changes the sampling rate for an interface. By default, the sampling rate of an interface is set to the same value as the current global default sampling rate. If the value entered is not a correct power of 2, the command generates an error message with the previous and next power-of-2 value. Select one of these two number and re-enter the command.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on S-Series Stacking. 8.1.1.0 Introduced on the E-Series ExaScale. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series.
54 Simple Network Management Protocol (SNMP) and Syslog This chapter contains commands to configure and monitor the simple network management protocol (SNMP) v1/v2/v3 and Syslog. Both features are supported on Dell Networking OS. The chapter contains the following sections: • SNMP Commands • Syslog Commands SNMP Commands The following SNMP commands are available in the Dell Networking OS.
show snmp Display the status of SNMP network elements. Syntax show snmp Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
show snmp engineID Display the identification of the local SNMP engine and all remote engines that are configured on the router. Syntax show snmp engineID Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series.
Example Version Description 7.5.1.0 Introduced on the C-Series. unknown Introduced on the E-Series. Dell#config!------command run on host connected to switch: --------------! > snmpwalk -c public 10.10.10.130 .1.3.6.1.2.1.31 | grep -i alias | more IF-MIB::ifAlias.134530304 = STRING: This is a port connected to Router2. This is a port connected to IF-MIB::ifAlias.
security-name name (Optional) Enter the keywords security-name then the security name as defined by the community MIB. access-listname (Optional) Enter a standard IPv4 access list name (a string up to 16 characters long). Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
as a sub-option, and each of those sub-options can accept any of the three suboptions as a sub-option, and so forth. The second Example shows the creation of a standard IPv4 ACL called snmp-ro-acl and then assigning it to the SNMP community guest. NOTE: For IPv6 ACLs, only IPv6 and UDP types are valid for SNMP; TCP and ICMP rules are not valid for SNMP. In IPv6 ACLs, port rules are not valid for SNMP.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command snmp-server enable traps Enable SNMP traps.
• cam-utilization • fan • supply • temperature For the snmp notification-type, enter one of the following optional parameters: • authentication • coldstart • linkdown • linkup • syslog-reachable • syslog-unreachable Defaults Not enabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Usage Information Dell Networking OS supports up to 16 SNMP trap receivers. For the cam-utilization notification option, the system generates syslogs and SNMP traps when the L3 host table or route table utilization goes above the threshold. If you do not configure this command, traps that controlled by this command are not sent. If you do not specify a notification-type and notificationoption, all traps are enabled. Related Commands snmp-server community — enables SNMP and sets the community string.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
To remove a specified group, use the no snmp-server group [group_name {v1 | v2c | v3 {auth | noauth | priv}}] [read name] [write name] [notify name] [access access-list-name | ipv6 accesslist-name | access-list-name ipv6 access-list-name]] command. Parameters group_name 1 | 2c | 3 Enter a text string (up to 20 characters long) as the name of the group.
access-listname ipv6 access-listname (Optional) Enter both an IPv4 and IPv6 access list name. Defaults As above. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
snmp-server host Configure the recipient of an SNMP trap operation. Syntax snmp-server host ip-address | ipv6-address [vrf vrf-name] traps | informs [version 1 | 2c | 3] [auth | no auth | priv] [community-string] [udp-port port-number] [notification-type] To remove the SNMP host, use the no snmp-server host ip-address [vrf vrf-name] traps | informs [version 1 | 2c | 3] [auth | noauth | priv] [community-string] [udp-port number] [notification-type] command.
noauth (OPTIONAL) Enter the keyword noauth to specify no authentication of a packet. priv (OPTIONAL) Enter the keyword priv to specify both authentication and then scrambling of the packet. communitystring Enter a text string (up to 20 characters long) as the name of the SNMP community. NOTE: For version 1 and version 2c security models, this string represents the name of the SNMP community.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 9.1(0.0) Added support for config and ecmp traps. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.4.1.0 Added support for VRRP traps. 7.6.1.0 Added support for STP and xSTP notification types. Introduced on the S-Series. 7.5.1.
Configuring Informs To send an inform, use the following steps: Related Commands 1. Configure a remote engine ID. 2. Configure a remote user. 3. Configure a group for this user with access rights. 4. Enable traps. 5. Configure a host to receive informs. snmp-server enable traps — enables SNMP traps. snmp-server community — configures a new community SNMPv1 or SNMPv2c. snmp-server location Configure the location of the SNMP server.
snmp-server packetsize Set the largest SNMP packet size permitted. Wen the SNMP server is receiving a request or generating a reply, use the snmp-server packetsize global configuration command. Syntax Parameters snmp-server packetsize byte-count byte-count Enter one of the following values 8, 16, 24 or 32. Packet sizes are 8000 bytes, 16000 bytes, 32000 bytes, and 64000 bytes. Defaults 8 Command Modes CONFIGURATION Command History This guide is platform-specific.
• For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords portchannel then a number. • For a Null interface, enter the keyword null then the Null interface number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Defaults The IP address assigned to the management interface is the default.
[access access-list-name | ipv6 access-list-name | access-listname ipv6 access-list-name] To remove a user from the SNMP group, use the no snmp-server user name {group_name remote ip-address vrf vrf-name udp-port portnumber} [1 | 2c | 3] [encrypted] [auth {md5 | sha} authpassword] [priv {des56 | aes128} priv password] [access accesslist-name | ipv6 access-list-name | access-list-name ipv6 access-list-name] command.
md5 | sha (OPTIONAL) Enter the keyword md5 or sha to designate the authentication level. • md5 — Message Digest Algorithm • sha — Secure Hash Algorithm auth-password (OPTIONAL) Enter a text string (up to 20 characters long) password that enables the agent to receive packets from the host. Minimum: eight characters long. priv (OPTIONAL) Enter the keywords priv to initiate a privacy authentication level setting.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. NOTE: For IPv6 ACLs, only IPv6 and UDP types are valid for SNMP. TCP and ICMP rules are not valid for SNMP. In IPv6 ACLs port rules are not valid for SNMP. No default values exist for authentication or privacy algorithms and no default password exists.
snmp-server user (for AES128-CFB Encryption) Specify that AES128-CFB encryption algorithm needs to be used for transmission of SNMP information. The Advanced Encryption Standard (AES) Cipher Feedback (CFB) 128-bit encryption algorithm is in compliance with RFC 3826. RFCs for SNMPv3 define two authentication hash algorithms, namely, HMACMD5-96 and HMAC-SHA1-96. These are the full forms or editions of the truncated versions, namely, HMAC-MD5 and HMAC-SHA1 authentication algorithms.
Usage Information To enable robust, effective protection and security for SNMP packets transferred between the server and the client, you can use the snmp-server user username group groupname 3 auth authentication-type authpassword priv aes128 priv-password to specify that AES128-CFB encryption algorithm needs to be used. You cannot modify the FIPS mode if SNMPv3 users are already configured and present in the system.
Related Commands show snmp user — displays the information configured on each SNMP user name. snmp-server view Configure an SNMPv3 view. Syntax snmp-server view view-name oid-tree {included | excluded} To remove an SNMPv3 view, use the no snmp-server view view-name oidtree {included | excluded} command. Parameters view-name Enter the name of the view (not to exceed 20 characters). oid-tree Enter the OID sub tree for the view (not to exceed 20 characters).
Example Dell# conf Dell#(conf) snmp-server view rview 1.3.6.1 included Related Commands show running-config snmp — displays the SNMP running configuration. snmp trap link-status Enable the interface to send SNMP link traps, which indicate whether the interface is up or down. Syntax snmp trap link-status To disable sending link trap messages, use the no snmp trap link-status command. Defaults Enabled. Command Modes INTERFACE Command History This guide is platform-specific.
Syslog Commands The following commands allow you to configure logging functions on all Dell Networking switches. clear logging Clear the messages in the logging buffer. Syntax clear logging Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the S4810, S4820T, S6000, Z9000, and MXL.
default logging console Return the default settings for messages logged to the console. Syntax default logging console Defaults level = 7 or debugging Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Related Commands logging monitor — sets the logging monitor parameters. terminal monitor — sends system messages to the terminal/monitor.
Related Commands logging trap — limit messages logged to the Syslog servers based on severity. logging Configure an IP address or host name of a Syslog server where logging messages are sent. Multiple logging servers of both IPv4 and/or IPv6 can be configured. Syntax logging {ip-address | ipv6-address | hostname} {{udp {port}} | {tcp {port}} [vrf vrf-name] To disable logging, use the no logging command. Parameters ip-address Enter the IPv4 address in dotted decimal format.
Version Description 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in Programmable-Mux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.4.1.0 Added support for IPv6. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series.
Defaults level = 7; size = 40960 bytes Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in Programmable-Mux (PMUX) mode only. 9.0.2.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the S4810, S4820T, S6000, Z9000, and MXL. This command is available with or without RBAC enabled.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in Programmable-Mux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T. 8.3.11.
• local3 (local use) • local4 (local use) • local5 (local use) • local6 (local use) • local7 (local use) • lpr (line printer system) • mail (mail system) • news (USENET news) • sys9 (system use) • sys10 (system use) • sys11 (system use) • sys12 (system use) • sys13 (system use) • sys14 (system use) • syslog (Syslog process) • user (user process) • uucp (Unix to Unix copy process) The default is local7.
logging on — enables logging. logging history Specify which messages are logged to the history table of the switch and the SNMP network management station (if configured). Syntax logging history level To return to the default values, use the no logging history command. Parameters level Indicate a value from 0 to 7 or enter one of the following equivalent words: emergencies, alerts, critical, errors, warnings, notifications, informational, or debugging. The default is 4 or warnings.
logging history size Specify the number of messages stored in the Dell Networking logging history table. Syntax logging history size size To return to the default values, use the no logging history size command. Parameters size Indicate a value as the number of messages to be stored. The range is from 0 to 500. The default is 1 message. Defaults 1 message Command Modes CONFIGURATION Command History This guide is platform-specific.
Parameters level Indicate a value from 0 to 7 or enter one of the following parameters: emergencies, alerts, critical, errors, warnings, notifications, informational, or debugging. The default is 7 or debugging. Defaults 7 or debugging Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
• For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For the Management interface on the stack-unit, enter the keyword ManagementEthernet then the slot/port information. The slot range is from 0 to 1. The port range is 0. • For a port channel interface, enter the keywords portchannel then a number. The range is from 1 to 128. • For a Null interface, enter the keyword null then the Null interface number.
logging synchronous Synchronize unsolicited messages and Dell Networking OS output. Syntax logging synchronous [level level | all] [limit number-ofbuffers] To disable message synchronization, use the no logging synchronous [level level | all] [limit number-of-buffers] command. Parameters all Enter the keyword all to ensure that all levels are printed asynchronously. level level Enter the keyword level then a number as the severity level. A high number indicates a low severity level and vice versa.
Usage Information When you enable logging synchronous, unsolicited messages appear between software prompts and outputs. Only the messages with a severity at or below the set level are sent to the console. If the message queue limit is reached on a terminal line and messages are discarded, a system message appears on that terminal line. Messages may continue to appear on other terminal lines. Related Commands logging on — enables logging.
Version Description E-Series legacy command Usage Information To block a type of message parameter, set the logging trap level to a lower number. For example, to block severity messages at level 6, set the level to 5. Related Commands logging — enables the logging to another device. logging on — enables logging. logging version Displays syslog messages in a RFC 3164 or RFC 5424 format.
show logging Display the logging settings and system messages logged to the internal buffer of the switch. Syntax Parameters Command Modes Command History show logging [number | history [reverse][number] | reverse [number] | summary] number (OPTIONAL) Enter the number of messages displayed in the output. The range is from 1 to 65535. history (OPTIONAL) Enter the keyword history to view only information in the Syslog history table.
Size (524288 bytes) Trap logging: level informational Oct 8 09:25:37: %RPM1:RP1 %BGP-5-ADJCHANGE: neighbor 223.80.255.254 closed. Hold time expired Oct 8 09:25:38: %RPM1:RP1 %BGP-5-ADJCHANGE: 192.200.13.2 Up Oct 8 09:25:38: %RPM1:RP1 %BGP-5-ADJCHANGE: 192.1.1.13 Up Oct 8 09:25:38: %RPM1:RP1 %BGP-5-ADJCHANGE: Up Oct 8 09:25:38: %RPM1:RP1 %BGP-5-ADJCHANGE: 192.1.1.
Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the S4810, S4820T, S6000, Z9000, and MXL. Example Dell(conf)#show logging audit Related Commands clear logging auditlog — clears audit log.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. This command displays internal software driver information, which may be useful during troubleshooting switch initialization errors, such as a downed Port-Pipe. terminal monitor Configure the Dell Networking OS to display messages on the monitor/terminal. Syntax terminal monitor To return to default settings, use the terminal no monitor command. defaults Disabled.
55 SNMP Traps This chapter lists the traps sent by the Dell Networking operating software. Each trap is listed by the fields Message ID, Trap Type, and Trap Option. Message ID Trap Type Trap Option COLD_START SNMP COLDSTART WARM_START SNMP WARMSTART COPY_CONFIG_COMPLETE SNMP NONE SNMP LINKDOWN SNMP LINKUP SNMP AUTH EGP_NEIGHBOR_LOSS SNMP NONE OSTATE_DOWN SNMP LINKDOWN SNMP LINKUP SNMP NONE SNMP NONE %SNMP-5-SNMP_COLD_START: SNMP COLD_START trap sent.
Message ID Trap Type Trap Option SNMP NONE SNMP NONE SNMP NONE SNMP NONE SNMP NONE NONE NONE ENVMON NONE ENVMON NONE ENVMON NONE CHM_CARD_PROBLEM ENVMON NONE CHM_ALARM_CUTOFF ENVMON NONE CHM_SFM_UP ENVMON NONE CHM_SFM_DOWN ENVMON NONE CHM_RPM_UP ENVMON NONE %RPM0-P:CP %SNMP-4-RMON_FALLING_THRESHOLD: RMON falling threshold alarm from SNMP OID RMON_HC_RISHING_THRESHOLD %RPM0-P:CP %SNMP-4-RMON_HC_RISING_THRESHOLD: RMON high-capacity rising threshold alarm from SNMP OID
Message ID Trap Type Trap Option ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON SUPPLY ENVMON SUPPLY ENVMON SUPPLY ENVMON SUPPLY ENVMON SUPPLY %RAM-6-RPM_STATE: RPM0 is in Standby State CHM_RPM_DOWN %CHMGR-2-RPM_DOWN: RPM 0 down - hard reset %CHMGR-2-RPM_DOWN: RPM 0 down - card removed CHM_RPM_PRIMARY %RAM-5-COLD_FAILOVER: RPM Failover Completed %RAM-5-HOT_FAILOVER: RPM Failover Completed %RAM-5-FAST_FAILOVER: RPM Failover
Message ID Trap Type Trap Option ENVMON SUPPLY ENVMON TEMP ENVMON TEMP ENVMON TEMP ENVMON TEMP ENVMON FAN ENVMON FAN ENVMON FAN %CHMGR-1-MINOR_PS: Minor alarm: power supply nonredundant CHM_MIN_ALARM_PS_CLR %CHMGR-5-MINOR_PS_CLR: Minor alarm cleared: power supply redundant CHM_MIN_ALRM_TEMP %CHMGR-2-MINOR_TEMP: Minor alarm: chassis temperature CHM_MIN_ALRM_TEMP_CLR %CHMRG-5-MINOR_TEMP_CLR: Minor alarm cleared: chassis temperature normal (%s %d temperature is within threshold of %dC) CHM_M
Message ID Trap Type Trap Option CHM_MIN_FANBAD_CLR ENVMON FAN ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE PROTO NONE For E1200: %CHMGR-2-FAN_OK: Minor alarm cleared: all fans in fan tray %d are good For E600 and E300: %CHMGR-5-FANOK: Minor alarm cleared: all fans in fan tray are good TME_TASK_SUSPEND %TME-2-TASK SUSPENDED: SUSPENDED - svce:%d - inst: %d - task:%s TME_TASK_TERM %TME-2-ABNORMAL_TASK_TERMIN
Message ID Trap Type Trap Option PROTO NONE PROTO NONE PROTO NONE PROTO NONE %RPM1-P:RP2 %VRRP-3-VRRP_BAD_AUTH: vrid-1 on Gi 11/12 rcvd pkt with authentication failure VRRP_GO_MASTER %VRRP-6-VRRP_MASTER: vrid-%d on %s entering MASTER VRRP_PROTOCOL_ERROR VRRP_PROTOERR: VRRP protocol error on %S BGP4_ESTABLISHED %TRAP-5-PEER_ESTABLISHED: Neighbor %a, state %s BGP4_BACKW_XSITION %TRAP-5-BACKWARD_STATE_TRANS: Neighbor %a, state %s 1746 SNMP Traps
Stacking 56 All commands in this chapter are specific to the Dell Networking operating software. You can use the commands to pre-configure a switch, so that the configuration settings are invoked when the switch is attached to other S-Series units. For information about using the S-Series stacking feature, refer to the “Stacking S-Series Switches” chapter in the Dell Networking OS Configuration Guide. CAUTION: You cannot enable stacking simultaneously with virtual link trunking (VLT).
Parameters stack-unit Enter the stack-unit number. For the S4820T, the range is from 0 to 11. members Enter the keyword members for all stack-units. Defaults Disabled (the failed switch is automatically rebooted). Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.3.1.0 Added the members option. redundancy protocol Enable hitless failover for a protocol. Syntax Protocols redundancy protocol lacp Enter the LACP protocol xstp Enter one of the following protocols: STP, RSTP, MSTP, PVST. Defaults Not enabled.
reset stack-unit Reset any designated stack member except the management unit (master unit). Syntax Parameters reset stack-unit hard stack-unit Enter the stack-unit number. The range is from 0 to 11. hard Reset the stack unit if the unit is in a problem state. Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Related Commands • reload – reboots Dell Networking OS. show redundancy Display the current redundancy configuration (status of automatic reboot configuration on stack management unit). Syntax show redundancy Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
-----------------------------------------------Primary Stack-unit: mgmt-id 0 Auto Data Sync: Full Failover Type: Hot Failover Auto reboot Stack-unit: Disabled Auto failover limit: 3 times in 60 minutes -- Stack-unit Failover Record ------------------------------------------------Failover Count: 0 Last failover timestamp: None Last failover Reason: None Last failover type: None -- Last Data Block Sync Record: -----------------------------------------------stack-unit Config: Start-up Config: Runtime Event Log
Usage Information Example Version Description 9.7(0.0) Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. The following describes the show system stack-ports command shown in the following example. Field Description Topology Lists the topology of stack ports connected: Ring, Daisy chain, or Standalone. Interface The unit/port ID of the connected stack port on this unit.
0/49 0/50 0/51 1/49 1/50 2/49 2/51 2/52 Dell# Example (Topology) 12 12 24 12 12 24 12 12 up up up up up up up up up down up up up up up down Dell# show system stack-ports topology Topology: Ring Interface Connection ---------------------0/49 1/49 0/50 0/51 2/49 1/49 0/49 1/50 2/51 2/49 0/51 2/51 1/50 2/52 Dell# Related Commands • reset stack-unit – resets the designated stack member.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. • reload – reboots Dell Networking OS.
Related Commands Version Description 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. • reload – reboots Dell Networking OS. • show system (S-Series and Z-Series) – displays the status of all stack members or a specific member. stack-unit stack-group Configure the stacking unit and stacking group by specifying an ID when adding units to a stack to ensure the unit is assigned to the correct group.
the current stack group will be removed when the unit is rebooted. NOTE: Any scripts used to streamline the stacking configuration process must be updated to reflect the Command Mode change from EXEC Privilege to CONFIGURATION to allow the scripts to work correctly. upgrade system stack-unit Copy the boot image or Dell Networking OS from the management unit to one or more stack members.
Usage Information To reboot using the new image, use the upgrade boot system stack-unit command. Related Commands • reload — reboots Dell Networking OS. • reset stack-unit — resets the designated stack member. • show system (S-Series and Z-Series) — displays the status of all stack members or a specific member. • show version — displays the current Dell Networking OS version information on the system.
Storm Control 57 The Dell Networking operating software storm control feature allows you to limit or suppress traffic during a traffic storm (Broadcast/Unknown Unicast Rate Limiting or Multicast on the C-Series and SSeries). Storm control is supported on Dell Networking OS. Important Points to Remember • Interface commands can only be applied on physical interfaces (virtual local area networks [VLANs] and link aggregation group [LAG] interfaces are not supported).
show storm-control broadcast Display the storm control broadcast configuration. Syntax Parameters show storm-control broadcast [interface] interface (OPTIONAL) Enter one of the following interfaces to display the interface-specific storm control configuration: • Defaults none Command Modes • EXEC • EXEC Privilege Command History For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. This guide is platform-specific.
Parameters interface Defaults none Command Modes • EXEC • EXEC Privilege Command History (OPTIONAL) Enter one of the following interfaces to display the interface specific storm control configuration: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords portchannel then a number.
show storm-control unknown-unicast Display the storm control unknown-unicast configuration. Syntax Parameters show storm-control unknown-unicast [interface] interface Defaults none Command Modes • EXEC • EXEC Privilege Command History (OPTIONAL) Enter one of the following interfaces to display the interface specific storm control configuration: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
storm-control broadcast (Configuration) Configure the percentage of broadcast traffic allowed in the network. Syntax storm-control broadcast [packets_per_second in] To disable broadcast rate-limiting, use the no storm-control broadcast [packets_per_second in] command. Parameters percentagedeci mal_value in | out Enter the percentage of broadcast traffic allowed in or out of the network. Optionally, you can designate a decimal value percentage, for example, 55.5%. The decimal range is from .1 to .9.
storm-control broadcast (Interface) Configure the percentage of broadcast traffic allowed on an interface (ingress only). Syntax storm-control broadcast [packets_per_second in] To disable broadcast storm control on the interface, use the no storm-control broadcast [packets_per_second in] command. Parameters packets_per_se cond in Enter the packets per second of broadcast traffic allowed into the network. The range is from 0 to 33554368.
To disable storm-control for multicast traffic into the network, use the no stormcontrol multicast packets_per_second in command. Parameters packets_per_se cond in Enter the packets per second of multicast traffic allowed into the network. The range is from 0 to 33554368. Defaults none Command Modes CONFIGURATION (conf) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Parameters packets_per_se cond in Enter the packets per second of broadcast traffic allowed into the network. The range is from 0 to 33554368. Defaults none Command Modes INTERFACE (conf-if-interface-slot/port) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 E-Series Only: Added the percentage decimal value option. 6.5.1.0 Introduced on the E-Series. Unknown Unicast Storm-Control is valid for Layer 2 and Layer 2/Layer 3 interfaces.
packets_per_se cond in C-Series and S-Series Only: Enter the packets per second of broadcast traffic allowed into the network. The range is from 0 to 33554431. Defaults none Command Modes INTERFACE (conf-if-interface-slot/port) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Spanning Tree Protocol (STP) 58 The commands in this chapter configure and monitor the IEEE 802.1d spanning tree protocol (STP) and are supported on the Dell Networking switch/routing platform. bridge-priority Set the bridge priority of the switch in an IEEE 802.1D spanning tree. Syntax bridge-priority {priority-value | primary | secondary} To return to the default value, use the no bridge-priority command. Parameters priority-value Enter a number as the bridge priority value.
Version Description 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. bpdu-destination-mac-address Use the Provider Bridge Group address in Spanning Tree or GVRP PDUs. Syntax Parameters bpdu-destination-mac-address [stp | gvrp] provider-bridge-group xstp Force STP, RSTP, and MSTP to use the Provider Bridge Group address as the destination MAC address in its BPDUs.
debug spanning-tree Enable debugging of the spanning tree protocol and view information on the protocol. Syntax debug spanning-tree {stp-id [all | bpdu | config | events | exceptions | general | root] | protocol} To disable debugging, use the no debug spanning-tree command. Parameters stp-id Enter zero (0). The switch supports one spanning tree group with a group ID of 0. protocol Enter the keyword for the type of STP to debug, either mstp, pvst, or rstp.
Version Description 6.2.1.1 Introduced on the E-Series. Usage Information When you enable debug spanning-tree bpdu for multiple interfaces, the software only sends information on BPDUs for the last interface specified. Related Commands protocol spanning-tree — enters SPANNING TREE mode on the switch. description Enter a description of the spanning tree. Syntax description {description} To remove the description from the spanning tree, use the no description {description} command.
disable Disable the spanning tree protocol globally on the switch. Syntax disable To enable Spanning Tree Protocol, use the no disable command. Defaults Enabled (that is, the spanning tree protocol is disabled.) Command Modes SPANNING TREE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Defaults 15 seconds Command Modes SPANNING TREE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. forward-delay — changes the wait time before STP transitions to the Forwarding state.
Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. forward-delay — changes the wait time before STP transitions to the Forwarding state. hello-time — changes the time interval between BPDUs.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. Usage Information STP is not enabled when you enter SPANNING TREE mode. To enable STP globally on the switch, use the no disable command from SPANNING TREE mode.
Example Dell(config-stp)#show config protocol spanning-tree 0 no disable Dell(config-stp)# show spanning-tree 0 Display the spanning tree group configuration and status of interfaces in the spanning tree group. Syntax Parameters show spanning-tree 0 [active | brief | guard | interface interface | root | summary] 0 Enter 0 (zero) to display information about that specific spanning tree group. active (OPTIONAL) Enter the keyword active to display only active interfaces in spanning tree group 0.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on the E-Series ExaScale. 8.4.2.1 Added support for the optional guard keyword on the CSeries, S-Series, and E-Series TeraScale. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.
Example Field Description “Port 1...” Displays the Interface type slot/port information and the status of the interface (Disabled or Enabled). “Port path...” Displays the path cost, priority, and identifier for the interface. “Designated root...” Displays the priority and MAC address of the root bridge of the STG that the interface belongs. “Designated port...” Displays the designated port ID.
Example (Brief) Dell#show span 0 brief Executing IEEE compatible Spanning Tree Protocol Root ID Priority 32768 Address 0001.e800.0a56 Root Bridge hello time 2, max age 20, forward delay 15 Bridge ID Priority 32768, Address 0001.e800.0a56 Configured hello time 2, max age 20, forward delay 15 Interface Designated Name PortID Prio Cost Sts Cost Bridge ID PortID -------------- ------ ---- ---- --- ----- -----------------Te 1/1 8.26 8 4 FWD 0 32768 0001.e800.0a56 8.26 Te 1/2 8.27 8 4 FWD 0 32768 0001.e800.
Parameters stp-id Enter the STP instance ID. The range is 0. cost cost Enter the keyword cost then a number as the cost. The range is from 1 to 65535. The defaults are: • 1-Gigabit Ethernet interface = 4. • 10-Gigabit Ethernet interface = 2. • Port Channel interface with 100 Mb/s Ethernet = 18. • Port Channel interface with 1 Gigabit Ethernet = 3. • Port Channel interface with 10 Gigabit Ethernet = 1.
Usage Information Version Description 8.4.2.1 Introduced the loopguard and rootguard options on the E-Series TeraScale, C-Series, and S-Series. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced the shutdown-on-violation option. 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. If you enable portfast bpduguard on an interface and the interface receives a BPDU, the software disables the interface and sends a message stating that fact.
System Time and Date 59 The commands in this chapter configure time values on the system, either using the Dell Networking operating software, or the hardware, or using the network time protocol (NTP). With NTP, the switch can act only as a client to an NTP clock host. For more information, refer to the “Network Time Protocol” section of the Management chapter in the Dell Networking OS Configuration Guide.
end-month Enter the name of one of the 12 months in English. You can enter the name of a day to change the order of the display to time day month year. end-time Enter the time in hours:minutes. For the hour variable, use the 24-hour format; example, 17:15 is 5:15 pm. end-year Enter a four-digit number as the year. The range is from 1993 to 2035. offset (OPTIONAL) Enter the number of minutes to add during the summer-time period. The range is from 1 to1440. The default is 60 minutes.
clock summer-time recurring Set the software clock to convert to daylight saving time on a specific day each year. Syntax clock summer-time time-zone recurring [start-week start-day start-month start-time end-week end-day end-month end-time [offset]] To delete a daylight saving time zone configuration, use the no clock summertime command. Parameters 1786 time-zone Enter the three-letter name for the time zone. This name is displayed in the show clock output. You can enter up to eight characters.
end-time Enter the time in hours:minutes:seconds. For the hour variable, use the 24-hour format; example, 17:15:00 is 5:15 pm. offset (OPTIONAL) Enter the number of minutes to add during the summer-time period. The range is from 1 to 1440. The default is 60 minutes. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Parameters timezonename Enter the name of the timezone. You cannot use spaces. offset Enter one of the following: • a number from 1 to 23 as the number of hours in addition to universal time coordinated (UTC) for the timezone. • a minus sign (-) then a number from 1 to 23 as the number of hours. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
To disable debugging of NTP transactions, use the no debug ntp {adjust | all | authentication | events | loopfilter | packets | select | sync} command. Parameters adjust Enter the keyword adjust to display information on NTP clock adjustments. all Enter the keyword all to display information on all NTP transactions. authentication Enter the keyword authentication to display information on NTP authentication transactions. events Enter the keyword events to display information on NTP events.
ntp authenticate Enable authentication of NTP traffic between the switch and the NTP time serving hosts. Syntax ntp authenticate To disable NTP authentication, use the no ntp authentication command. Defaults Not enabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
md5 Specify that the authentication key is encrypted using MD5 encryption algorithm. 0 Specify that authentication key is entered in an unencrypted format (default). 7 Specify that the authentication key is entered in DES encrypted format. key Enter the authentication key in the previously specified format. Defaults NTP authentication is not configured by default. If you do not specify the option [0 | 7], 0 is selected by default.
ntp trusted-key — configures a trusted key. ntp broadcast client Set up the interface to receive NTP broadcasts from an NTP server. Syntax ntp broadcast client To disable broadcast, use the no ntp broadcast client command. Defaults Disabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Added support for IPv6 multicast addresses. 8.3.7.0 Introduced on the S4810. 6.1.1.0 Introduced on the E-Series. ntp master Configure the switch as NTP Server.
ntp server Configure an NTP time-serving host. Syntax Parameters ntp server[vrf vrf-name] {hostname | ipv4-address | ipv6address} [key keyid] [prefer] [version number] vrf vrf-name (Optional) Enter the keyword vrf and then the name of the VRF to configure a NTP time-serving host corresponding to that VRF. ipv4-address | ipv6-address Enter an IPv4 address (A.B.C.D) or IPv6 address (X:X:X:X::X) of NTP server. hostname Enter the hostname of the server.
Usage Information You can configure multiple time-serving hosts . From these time-serving hosts, the Dell Networking OS chooses one NTP host with which to synchronize. To determine which server was selected, use the show ntp associations command. Because many polls to NTP hosts can impact network performance, Dell Networking recommends limiting the number of hosts configured. Related Commands show ntp associations — displays the NTP servers configured and their status.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. ntp trusted-key Set a key to authenticate the system to which NTP synchronizes. Syntax ntp trusted-key number To delete the key, use the no ntp trusted-key number command. Parameters number Enter a number as the trusted key ID.
Related Commands ntp authentication-key — sets an authentication key for NTP. ntp authenticate — enables the NTP authentication parameters you set. show clock Display the current clock settings. Syntax Parameters show clock [detail] detail (OPTIONAL) Enter the keyword detail to view the source information of the clock. Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific.
Related Commands clock summer-time recurring — displays the time and date from the switch hardware clock. show ntp associations Display the NTP master and peers. Syntax show ntp associations Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Field Description remote Displays the remote IP address of the NTP peer. ref clock Displays the IP address of the remote peer’s reference clock. st Displays the peer’s stratum, that is, the number of hops away from the external time source. A 16 in this column means the NTP peer cannot reach the time source. when Displays the last time the switch received an NTP packet. poll Displays the polling interval (in seconds). reach Displays the reachability to the peer (in octal bitstream).
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.6(0.0) Added support for VRF. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Added IPv6 support. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. show ntp status Display the current NTP status. Syntax show ntp status Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific.
Usage Information The following describes the show ntp status command shown in the Example below. Field Description “Clock is...” States whether or not the switch clock is synchronized, which NTP stratum the system is assigned and the IP address of the NTP peer. “frequency is...” Displays the frequency (in ppm), stability (in ppm) and precision (in Hertz) of the clock in this system. “reference time is...” Displays the reference time stamp. “clock offset is...
60 u-Boot All commands in this chapter are in u-Boot and are supported on the Dell Networking S4810 and 4820T platforms only. To access this mode, press any key when the following line appears on the console during a system boot. Hit any key to stop autoboot: Enter u-Boot immediately, as the => prompt indicates. NOTE: This chapter describes only a few commands available in u-Boot.
Rebooting...;reset bootdelay=5 loads_echo=1 rootpath=/opt/nfsroot hostname=unknown loadaddr=640000 ftpuser=force10 ftppasswd=force10 uboot=u-boot.bin tftpflash=tftpboot $loadaddr $uboot; protect off 0xfff80000 + $filesize; erase 0x fff80000 +$filesize; cp.b $loadaddr 0xfff80000 $filesize; protect on 0xfff80000 +$filesize; cmp.b $loadaddr 0xfff80000 $filesize ethact=eTSEC1 ethaddr=00:01:E8:82:09:B2 serverip=10.11.9.4 primary_boot=f10boot tftp://10.11.9.
reset Reload the system. Syntax reset Command Modes uBoot Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version 8.3.19.0 Introduced on the S4820T. Version 8.3.7.0 Introduced on the S4810. Save your changes before resetting the system or all your changes will be lost.
setenv Configure system settings. Syntax Parameters setenv [gatewayip address | primary_image f10boot location | secondary_image f10boot location | default_image f10boot location | ipaddre address | ethaddr address | enablepwdignore | stconfigignore] gatewayip address Enter the IP address for the default gateway. primary_image Enter the keywords primary_image to configure the boot parameters used in the first attempt to boot Dell Networking OS.
The following is a list of the Dell Networking OS version history for this command. u-Boot Version 8.3.19.0 Introduced on the S4820T. Version 8.3.7.0 Introduced on the S4810.
61 Tunneling Tunneling is supported on Dell Networking OS. ip unnumbered Configure a tunnel interface to operate without a unique IPv4 address and select the interface from which the tunnel borrows its address. Syntax ip unnumbered {interface-type slot/port} To set the tunnel back to default logical address use the no ip unnumbered command. If the tunnel was previously operational, the tunnel interface is operationally down unless you also configure the tunnel IPv6 address.
NOTE: The ip unnumbered command can specify an interface name that does not exist or does not have a configured IPv6 address. The tunnel interface is not changed to operationally up until the logical ip address is identified from one of the address family. ipv6 unnumbered Configure a tunnel interface to operate without a unique IPv6 address and select the interface from which the tunnel borrows its address.
tunnel allow-remote Configure an IPv4 or IPv6 address or prefix whose tunneled packets are accepted for decapsulation. If you do not configure allow-remote entries, tunneled packets from any remote peer address is accepted. This feature is supported on Dell Networking OS. Syntax tunnel allow-remote {ip-address | ipv6-address} [mask] To delete a configured allow-remote entry use the no tunnel allow-remote command. Any specified address/mask values must match an existing entry for the delete to succeed.
tunnel destination Set a destination endpoint for the tunnel. Syntax tunnel destination {ip-address | ipv6–address} To delete a tunnel destination address, use the no tunnel destination {ipaddress | ipv6–address} command. Parameters ip-address Enter the destination IPv4 address for the tunnel. ipv6–address Enter the destination IPv6 address for the tunnel. Defaults none Command Modes INTERFACE TUNNEL (conf-if-tu) Command History Usage Information Version Description 9.7(0.
value Enter a value to set the DSCP value in the tunnel header. The range is from 0 to 63. The default value of 0 denotes mapping of original packet DSCP (IPv4)/Traffic Class (IPv6) to the tunnel header DSCP (IPv4)/Traffic Class (IPv6) depending on the mode of tunnel. Defaults 0 (Mapped) Command Modes INTERFACE TUNNEL (conf-if-tu) Command History Usage Information Version Description 9.9(0.0) Introduced on the C9010. 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.
Usage Information Version Description 9.5(0.1) Introduced on the Z9500. 9.3(0.0) Introduced on the S6000, S4810, S4820T, Z9000. This command is only valid for tunnel interfaces with an IPv6 outer header. tunnel hop-limit Configure the method to set the IPv4 time-to-live or the IPv6 hop limit value in the outer tunnel header. Syntax tunnel hop-limit value To restore the default tunnel hop-limit, use the no tunnel hop-limit command.
tunnel keepalive Configure the tunnel keepalive target, interval and attempts. Syntax tunnel keepalive {ip-address | ipv6-address}[interval {seconds}] [attempts {count | unlimited}] To disable the tunnel keepalive probes use the no tunnel keepalive command. Parameters ip-address ipv6 address Enter the IPv4 or IPv6 address of the peer to which the keepalive probes will be sent.
into a keepalive down state that does not clear in a few seconds, then performing shutdown - no shutdown sequence on one end should bring both ends back to up. tunnel-mode Enable a tunnel interface. . Syntax tunnel mode {ipip | ipv6 | ipv6ip}[decapsulate-any] To disable an active tunnel interface, use the no tunnel mode command. Parameters ipip Enable tunnel in RFC 2003 mode and encapsulate IPv4 and/or IPv6 datagrams inside an IPv4 tunnel.
Configuration of IPv6 commands over decapsulate-any tunnel causes an error. tunnel source Set a source address for the tunnel. Syntax tunnel source {ip-address | ipv6–address | interface-typenumber | anylocal} To delete the current tunnel source address, use the no tunnel source command. Parameters ip-address Enter the source IPv4 address in A.B.C.D format. ipv6–address Enter the source IPv6 address in X:X:X:X::X format.
allows the multipoint receive-only tunnel to decapsulate tunnel packets addressed to any IPv4 or IPv6 (depending on the tunnel mode) address configured on the switch that is operationally Up.
62 Uplink Failure Detection (UFD) Uplink failure detection (UFD) provides detection of the loss of upstream connectivity and, if you use this with NIC teaming, automatic recovery from a failed link. clear ufd-disable Re-enable one or more downstream interfaces on the switch/router that are in a UFD-Disabled Error state so that an interface can send and receive traffic.
Related Commands Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.4.2.3 Introduced on the S-Series S50. • downstream — assigns a port or port-channel to the uplink-state group as a downstream interface. • uplink-state-group — creates an uplink-state group and enables the tracking of upstream links. debug uplink-state-group Enable debug messages for events related to a specified uplink-state group or all groups.
Related Commands clear ufd-disable — re-enables downstream interfaces that are in a UFD-Disabled Error state. description Enter a text description of an uplink-state group. Syntax Parameters description text text Text description of the uplink-state group. The maximum length is 80 alphanumeric characters. Defaults none Command Modes UPLINK-STATE-GROUP Version 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in Programmable-Mux (PMUX) mode only.
downstream Assign a port or port-channel to the uplink-state group as a downstream interface. Syntax downstream interface To delete an uplink-state group, enter the no downstream interface command.
You can assign individual member ports of a port channel to the group. An uplinkstate group can contain either the member ports of a port channel or the port channel itself, but not both. Related Commands • upstream — assigns a port or port-channel to the uplink-state group as an upstream interface. • uplink-state-group — creates an uplink-state group and enables the tracking of upstream links.
downstream disable links Configure the number of downstream links in the uplink-state group that are disabled if one upstream link in an uplink-state group goes down. Syntax downstream disable links {number |all} To revert to the default setting, use the no downstream disable links command. Parameters number Enter the number of downstream links to be brought down by UFD. The range is from 1 to 1024. all Brings down all downstream links in the group.
enable Enable uplink state group tracking for a specific UFD group. Syntax enable To disable upstream-link tracking without deleting the uplink-state group, use the no enable command. Defaults Upstream-link tracking is automatically enabled in an uplink-state group. Command Modes UPLINK-STATE-GROUP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Related Commands Version Description 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in Programmable-Mux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.4.2.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in Programmable-Mux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.4.2.3 Introduced on the S-Series S50.
• uplink-state-group — create an uplink-state group and enables the tracking of upstream links. uplink-state-group Create an uplink-state group and enable the tracking of upstream links on a switch/ router. Syntax uplink-state-group group-id To delete an uplink-state group, enter the no uplink-state-group group-id command. Parameters group-id Enter the ID number of an uplink-state group. The range is from 1 to 16.
Example Related Commands Dell(conf)#uplink-state-group 16 Dell(conf)# 02:23:17: %RPM0-P:CP %IFMGR-5-ASTATE_UP: Changed uplink state group Admin state to up: Group 16 • show running-config uplink-state-group — displays the current configuration of one or more uplink-state groups. • show uplink-state-group — displays the status information on a specified uplink-state group or all groups. upstream Assign a port or port-channel to the uplink-state group as an upstream interface.
Usage Information Version Description 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in Programmable-Mux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.4.2.3 Introduced on the S-Series S50. You can assign physical port or port-channel interfaces to an uplink-state group. You can assign an interface to only one uplink-state group.
VLAN Stacking 63 With the virtual local area network (VLAN)-stacking feature (also called stackable VLANs and QinQ), you can “stack” VLANs into one tunnel and switch them through the network transparently. The Dell Networking operating software supports this feature on Dell Networking OS. For more information about basic VLAN commands, refer to the Virtual LAN (VLAN) Commands section in the Layer 2 chapter.
dei enable Make packets eligible for dropping based on their DEI value. Syntax dei enable Defaults Packets are colored green; no packets are dropped. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the C-Series and S-Series. You must first enable DEI for this configuration to take effect. member Assign a stackable VLAN access or trunk port to a VLAN. The VLAN must contain the vlan-stack compatible command in its configuration.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.2.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the C-Series and S-Series. Usage Information You must enable the stackable VLAN (using the vlan-stack compatible command) on the VLAN prior to adding a member to the VLAN. Related Commands vlan-stack compatible — enables stackable VLAN on a VLAN. stack-unit stack-group Configure a stacking group specified by an ID.
Usage Information WARNING: The following message displays to confirm the command: All non-default configurations on the related member ports ports () will be removed. Do you want to continue (y/n)? If you enter “y”, all non-default configurations on any member ports of the current stack group is removed when the unit is rebooted. vlan-stack access Specify a Layer 2 port or port channel as an access port to the stackable VLAN network.
vlan-stack compatible Enable the stackable VLAN feature on a VLAN. Syntax vlan-stack compatible To disable the Stackable VLAN feature on a VLAN, use the no vlan-stack compatible command. Defaults Not configured. Command Modes CONF-IF-VLAN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
2 Active 3 Active 4 Active 5 Active Dell# M M M M M M M M M M M Te 1/13 Te 1/1-3 Po1(Te 1/14-15) Te 1/18 Te 1/4 Po1(Te 1/14-15) Te 1/18 Te 1/5 Po1(Te 1/14-15) Te 1/18 Te 1/6 vlan-stack dot1p-mapping Map C-Tag dot1p values to a S-Tag dot1p value. You can separate the C-Tag values by commas and dashed ranges are permitted. Dynamic mode CoS overrides any Layer 2 QoS configuration in case of conflicts.
vlan-stack protocol-type Define the stackable VLAN tag protocol identifier (TPID) for the outer VLAN tag (also called the VMAN tag). If you do not configure this command, Dell Networking OS assigns the value 0x9100. Syntax Parameters vlan-stack protocol-type number number Enter the hexadecimal number as the stackable VLAN tag. You may specify both bytes of the 2-byte S-Tag TPID. The range is from 0 to FFFF. The default is 9100.
Related Commands Number Resulting TPID 81 0x0081 8100 0x8100 portmode hybrid — sets a port (physical ports only) to accept both tagged and untagged frames. A port configured this way is identified as a hybrid port in report displays. vlan-stack trunk — specifies a Layer 2 port or port channel as a trunk port to the Stackable VLAN network. vlan-stack trunk Specify a Layer 2 port or port channel as a trunk port to the Stackable VLAN network.
Version Description 7.7.1.0 Functionality augmented for E-Series to enable multipurpose use of the port. 7.6.1.0 Introduced on the C-Series and S-Series. E-Series original Command Usage Information Prior to using this command, to place the interface in Layer 2 mode, execute the switchport command. To remove the trunk port designation, first remove the port (using the no member interface command) from all stackable VLAN-enabled VLANs. Starting with Dell Networking OS version 7.8.1.
shutdown Dell(conf-if-vl-20)#do show vlan Codes: * - Default VLAN, G - GVRP VLANs Q: U - Untagged, T - Tagged x - Dot1x untagged, X - Dot1x tagged G - GVRP tagged, M - Vlan-stack NUM Status Description * 1 Inactive 20 Active 100 Active Dell(conf-if-vl-20)# Example 2 Q Ports T Te 1/42 M Te 1/42 Dell(config)#vlan-stack protocol-type 88A8 Dell(config)#interface TenGigabitethernet 3/10 Dell(conf-if-te-3/10)#no shutdown Dell(conf-if-te-3/10)#switchport Dell(conf-if-te-3/10)#vlan-stack access Dell(conf-if-te-3/
64 Virtual Link Trunking (VLT) Virtual link trunking (VLT) allows physical links between two chassis to appear as a single virtual link to the network core. VLT eliminates the requirement for Spanning Tree protocols by allowing link aggregation group (LAG) terminations on two separate distribution or core switches, and by supporting a loop-free topology.
ipv6 Enter the keyword ipv6 then an IPv6 address in the X:X:X:X::X format. interval seconds Enter the keyword interval to specify the time interval to send hello messages. The range is from 1 to 5 seconds. The default is 1 second. Defaults 1 second Command Modes VLT DOMAIN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
ndp Clear the VLT statistics for NDP. Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator.
Defaults Not configured. Command Modes VLT DOMAIN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Parameter Version Description 9.7(0.0) Introduced on the S4820T, S4810, S6000, S5000, Z9000, S6000–ON and Z9500. Enter the value (in seconds) to specify the time interval for delay restore timer to abort.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Added port-channel parameter on the S4810. 8.3.8.0 Introduced on the S4810. LACP on the VLT ports (on a VLT switch or access device), which are members of the virtual link trunk, is not brought up until the VLT domain is recognized on the access device.
Command Modes VLT DOMAIN (conf-vlt-domain) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in Programmable-Mux (PMUX) mode only. 9.2(0.
Usage Information Version Description 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in Programmable-Mux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Added support for the peer-down-vlan parameter. 8.3.8.0 Introduced on the S4810. To configure the VLAN from where the VLT peer forwards packets received over the VLTi from an adjacent VLT peer that is down, use the peer-down-vlan parameter.
peer-routing-timeout Configure the delay after which peer routing is disabled when the peer is unavailable. This command is applicable for both IPV6/IPV4. If not configured, peer-routing will not be disabled at all even though the peer is unavailable. Syntax peer-routing-timeout value To restore the default value, use the no peer-routing-timeout command. Parameters value Enter the timeout value in seconds. The range is from 1 to 65535. The default value is infinity.
Default 32768 Command Modes VLT DOMAIN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator.
Version Description 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.0 Introduced on the S4810. Usage Information The version shown in the show vlt brief output command displays the VLT version number which is different from the Dell Networking OS version number. VLT version numbers are begin with odd numbers such as 3 or 5.
Example Version Description 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.0 Introduced on the S4810. Dell_VLTpeer1# show vlt backup-link VLT Backup Link ----------------Destination: Peer HeartBeat status: HeartBeat Timer Interval: HeartBeat Timeout: UDP Port: HeartBeat Messages Sent: HeartBeat Messages Received: 10.11.200.18 Up 1 3 34998 1026 1025 show vlt counters Displays the counter information.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. Usage Information If you do not add a parameter such as arp or mac, the output displays all of the counters.
show vlt detail Displays detailed status information about VLT domains currently configured on the switch. Syntax show vlt detail Default Not configured. Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.2(0.2) Introduced on the Z9000, S4810, and S4820T. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in Programmable-Mux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. Dell#show vlt inconsistency ip mroute Spanned Multicast Routing IIF Inconsistency Multicast Route --------------(22.22.22.200, 225.1.1.2) (*, 225.1.1.
Example Dell#show vlt mismatch Domain ------Parameters Local -------------Unit-ID 0 Peer ----1 Vlan-config -----------Vlan-ID Local Mode ---------------100 Peer Mode --------- -- L3 Vlan IPV4 Multicast Status -------------------------Vlan-ID Local Status ------------------4094 Peer Status ----------- Active Inactive Dell# Example for Qin-Q implementatio n over VLT Dell#show vlt mismatch Domain -----Parameters Local -------------PB for stp Enabled Peer ---Disabled Vlan-type-config -------------
--------128 -------128 ----------4094 ---------100 Dell# show vlt role Displays the VLT peer status, role of the local VLT switch, VLT system MAC address and system priority, and the MAC address and priority of the local VLT device. Syntax show vlt role Default Not configured. Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Local System MAC address: 00:01:e8:8a:df:e6 Local System Role Priority: 32768 show vlt statistics Displays statistics on VLT operations. Syntax Parameters show vlt statistics [arp | domain | igmp-snoop | mac | multicast | ndp] domain Display the VLT statistics for the domain. multicast Display the VLT statistics for multicast. mac Display the VLT statistics for the MAC address. arp Display the VLT statistics for ARP. igmp-snoop Display the VLT statistics for IGMP snooping.
Example NOTE: The following example shows the statistics for all of the VLT parameters. If you enter a specific keyword, such as mac, only the statistics for that VLT parameter displays.
show vlt statistics igmp-snoop Displays the informational packets and IGMP control PDUs that are exchanged between VLT peer nodes. Syntax show vlt statistics igmp-snoop Default Not configured. Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.
Command Modes VLT DOMAIN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.5(0.1) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in Programmable-Mux (PMUX) mode only. 9.0.0.0 Introduced on the Z9000. 8.3.19.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in Programmable-Mux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.0 Introduced on the S4810. When you create a VLT domain on a switch, Dell Networking OS automatically assigns a unique unit ID (0 or 1) to each peer switch.
Version Description 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in Programmable-Mux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.0 Introduced on the S4810. Usage Information The VLT domain ID must be the same between the two VLT devices. If the domain ID is not the same, a syslog message is generated and VLT does not launch.
Version Description 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in Programmable-Mux (PMUX) mode only. show vlt private-vlan Display the private VLAN (PVLAN) associated with the VLT LAG for VLT peer nodes. Syntax show vlt private-vlan Command Modes EXEC Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.4(0.0) Introduced on the S6000. 9.3(0.0) Introduced on the Z9000, S4810, and S4820T.
65 VLT Proxy Gateway The Virtual link trucking (VLT) proxy gateway feature allows a VLT domain to locally terminate and route L3 packets that are destined to a Layer 3 (L3) end point in another VLT domain. Enable the VLT proxy gateway using the link layer discover protocol (LLDP) method or the static configuration. For more information, refer to Dell Networking OS Command Line Reference Guide. proxy-gateway lldp Enables the proxy-gateway feature using LLDP protocol.
proxy-gateway static Enables the proxy-gateway feature using static configurations. S4820T Syntax [no] proxy-gateway static Command Modes VLT DOMAIN Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, Z9000. Usage Information When proxy-gateway static configuration is added, the setting is saved in the Layer 2 module.
Combination: 3, 4, 5-10, 8 Command Modes Command History VLT DOMAIN PROXY GW STATIC Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. Usage Information You can configure the MAC address, of a VLT peer in remote VLT Domain, to be associated with the static VLT proxy gateway and exclude a VLAN or a range of VLANs from proxy routing..
Command Modes Command History VLT DOMAIN PROXY GW LLDP Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. Usage Information The VLT port channel interface which is connecting to the remote VLT domain must be configured as peer-domain-link. Configure the VLANs that needs to be excluded from VLT Proxy Gateway.
Example Dell(conf-vlt-domain-proxy-gw-lldp)# peer-timeout 5 vlt-peer-mac transmit Enables the device to transmit, the peer's MAC address along with its own mac-address in the LLDP TLV packets, to the remote VLT Domain. S4820T Syntax [no] vlt-peer-mac transmit Command Modes VLT DOMAIN PROXY GW LLDP Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000.
Command Modes EXEC EXEC Privilege Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000.
Virtual Routing and Forwarding (VRF) 66 Virtual Routing and Forwarding (VRF) allows multiple instances of a routing table to co-exist on the same router at the same time. ip vrf Creates a customer VRF. Syntax ip vrf {vrf-name | management} [vrf_id] To delete a customer VRF, use the no ip vrf {vrf-name | management} [vrf_id] command. Parameters vrf-name Enter the name of the VRF that you want to create. management Use this keyword when you want to create the management VRF.
creating a management VRF. For other types of VRFs, VRF ID is an optional parameter. All values in the valid range that are not already taken are allowed. ip http vrf Configures an HTTP client with a VRF that is used to connect to the HTTP server. S4820T Syntax ip http vrf {management | vrf-name} To undo the HTTP client configuration, use the ip http vrf command. Parameters management Enter the keyword management for configuring the management VRF that uses an HTTP client.
To delete the descriptive name for a customer VRF, use the no description string command. Parameters string Enter a descriptive name for the VRF. Defaults None. Command Modes VRF MODE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON and Z9500. 9.4.(0.0) Introduced on the S-Series and Z9000. Use this command to attach an interface to a configured VRF. You can attach an interface to either a non-default VRF or a management VRF. To assign a port-back to a default VRF, remove VRF association from the interface. You can use this only if there is no IP address configured on the interface.
Parameters route-export Enter the keyword to leak or share routes between VRFs. tag Enter a tag (export route target) to expose routes to other VRFs. This tag acts as an identifier for exported routes. You can use this identifier while importing these routes into another non-default VRF. route-mapname (Optional) Enter the name of the route-map to filter the exported routes. You can leak global routes to be made available to VRFs.
ip route-import Imports IPv4 routes that are leaked by another VRF using the tag specified by that VRF during export of these routes. Syntax Parameters ip route-import tag [route-map—name] route-import Enter the keyword route-import to import routes into the VRF. tag Enter a tag (ASN number) to specify an import route target for importing routes from another VRF. To import leaked routes from another VRF, you must use the same ASN number that is specified as the export route target at the source VRF.
ipv6 route-export Enables route leaking between VRFs. Exports or shares IPv6 routes corresponding to one VRF with other non-default VRFs. Syntax Parameters ipv6 route-export tag [route-map-name] route-export Enter the keyword route-export to leak or share routes between VRFs. tag Enter a tag (ASN number) as the export route target to expose routes to other VRFs. This tag acts as an identifier for exported routes. You can use this identifier while importing these routes into another non-default VRF.
filtering options to match BGP, the BGP route is not leaked as that route is not active in the Source VRF. Related Commands ipv6 route-import – imports IPv6 routes from another VRF. ipv6 route-import Imports IPv6 routes that are leaked by another VRF using the tag specified by that VRF during export of these routes. Syntax Parameters ipv6 route-import tag [route-map-name] route-import Enter the keyword route-import to import IPv6 routes into the VRF.
The export-target and import-target support only the match protocol and match prefix-list options. Other options that are configured in the route-maps are ignored. Related Commands ipv6 route-export – exports IPv6 routes to another VRF. match source-protocol Enables you to specify matching criteria while exporting or importing routes. Syntax Parameters match source-protocol {bgp | isis | ospf | connected | static} bgp Enter the keyword bgp to leak or share routes corresponding to the BGP protocol.
Related Commands ipv6 route-import – imports IPv6 routes from another VRF. redistribute Redistributes leaked or exported routes corresponding to specific protocols. Syntax Parameters redistribute {imported-bgp | import-ospf | import-isis} imported-bgp Enter the keyword imported-bgp to redistribute leaked routes that are learnt using the BGP protocol. imported-ospf Enter the keyword imported-ospf to redistribute leaked routes that are learnt using the OSPF protocol.
Command Modes VRF MODE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.4.(0.0) Introduced on the S-Series and Z9000.
Command Modes CONFIGURATION-VRF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OSCommand Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON and Z9500. 9.4(0.0) Introduced on the S–Series.
Ma Ma Ma Ma Ma Ma Ma Ma Ma Ma Nu 0, 2/0, 3/0, 4/0, 5/0, 6/0, 7/0, 8/0, 9/0, 10/0, 11/0, Vl 1 Te 0/14,16-17 Te 0/15 test1 test2 management 1 2 64 FTOS#show ip vrf test1 VRF-Name VRF-ID Interfaces test1 1 Te 0/14,16-17 show run vrf Displays configuration information corresponding to all the VRFs in the system. Syntax Parameters show run vrf vrf-name vrf vrf-name Enter the keyword vrf and then the name of the VRF..
Related Commands Virtual Routing and Forwarding (VRF) 1885
Virtual Router Redundancy Protocol (VRRP) 67 Virtual router redundancy protocol (VRRP) is supported by the Dell Networking operating system on Dell Networking OS. IPv4 VRRP Commands The following are IPv4 VRRP commands. advertise-interval Set the time interval between VRRP advertisements. Syntax advertise-interval {seconds | centisecs centisecs } To return to the default settings, use the no advertise-interval command. Parameters seconds Enter a number of seconds. The range is from 1 to 255.
Usage Information Version Description 9.5(0.0) Added support for centisecs on the Z9000, S6000, S4820T, S4810, and MXL. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. Dell Networking recommends keeping the default setting for this command.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. The given password is encrypted by the system and the show config displays an encrypted text string for any of the encrypted typed used.
Example Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. Dell#clear counters vrrp vrf jay Clear "show vrrp" counters of all vrrp groups on all interfaces in VRF jay [confirm] yes debug vrrp Allows you to enable debugging of VRRP.
interface Enter the keyword interface to enable debugging of interface state changes.. ipv6 Enter the keyword ipv6 to enable debugging for IPv6. packets Enter the keyword packets to enable debugging of VRRP control packets. state Enter the keyword state to enable debugging of VRRP state changes. timer Enter the keyword timer to enable debugging of the VRRP timer. Command Modes EXEC Privilege Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
Usage Information To enable VRRP traffic, assign an IP address to the VRRP group using the virtual-address command and enter no disable. Related Commands virtual-address — specifies the IP address of the virtual router. hold-time Specify a delay (in seconds) before a switch becomes the MASTER virtual router. By delaying the initialization of the VRRP MASTER, the new switch can stabilize its routing tables.
Usage Information If a switch is a MASTER and you change the hold timer, disable and re-enable VRRP for the new hold timer value to take effect. Related Commands disable — disables a VRRP group. preempt To preempt or become the MASTER router, permit a BACKUP router with a higher priority value. Syntax preempt To prohibit preemption, use the no preempt command. Defaults Enabled (that is, a BACKUP router can preempt the MASTER router).
address (that is, the router is the OWNER). The range is from 1 to 255. The default is 100. Defaults 100 Command Modes VRRP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.16.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. Dell(conf-if-vrid-4)#show config vrrp-group 4 virtual-address 119.192.182.124 ! show vrrp View the VRRP groups that are active.
Command Modes • EXEC • EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.
Item Description • BACKUP (the interface associated with the BACKUP router). Master addr Displays the IP address of the MASTER router. Virtual addr(s) Displays the virtual IP addresses of the VRRP routers associated with the interface. Example (Brief) Dell>Interface Grp Pri Pre State Master addr Virtual addr(s) Description----------------------------------------------------------Te 1/37 1 100 Y Master 200.200.200.200 200.200.200.201 Te 1/37 2 100 Y Master 200.200.200.200 200.200.200.202 200.200.200.
Item Description • Gratuitous ARP sent displays the number of gratuitous ARPs sent. Virtual MAC address Displays the virtual MAC address of the VRRP group. Virtual IP address Displays the virtual IP address of the VRRP router to which the interface is connected. Authentication:... States whether authentication is configured for the VRRP group. If it is, the authentication type and the password are listed. Tracking states.. This line is displayed if the track command is configured on an interface.
00:00:5e:00:01:14 Virtual IP address: 10.0.0.2 Authentication: (none) Dell#show vrrp vrf jay brief Interface Group Pri Pre State Master addr Virtual addr(s) Description ------------------------------------------------------------------------------------------------Te 1/0 IPv4 20 100 Y Master 10.0.0.3 10.0.0.2 Dell# track Monitor an interface and lower the priority value of the VRRP group on that interface if it is disabled.
Usage Information If the interface is disabled, the cost value is subtracted from the priority value and forces a new MASTER election if the priority value is lower than the priority value in the BACKUP virtual routers. version Set VRRP protocol version for IPv4 group. Syntax version {2 | 3 | both} To return to the default setting, use the no version command. Parameters 2 Enter the 2 parameter to specify VRRP version 2 as defined by RFC 3768, Virtual Router Redundancy Protocol.
Example Dell(conf-if-te-1/1-vrid-100)#version ? 2 VRRPv2 3 VRRPv3 both Interoperable, send VRRPv3 receive both Dell(conf-if-te-1/1-vrid-100)#version 3 virtual-address Configure up to 12 IP addresses of virtual routers in the VRRP group. To start sending VRRP packets, set at least one virtual address for the VRRP group. Syntax virtual-address ip-address1 [... ip-address12] To delete one or more virtual IP addresses, use the no virtual-address ipaddress1 [... ip-address12] command.
Usage Information Version Description 6.2.1.1 Introduced on the E-Series. The VRRP group only becomes active and sends VRRP packets when a virtual IP address is configured. When you delete the virtual address, the VRRP group stops sending VRRP packets. A system message appears after you enter or delete the virtual-address command.
Related Command • When the system reloads, VRRP waits 600 seconds (10 minutes) to bring up VRRP on all interfaces that are up and configured for VRRP. • When an interface comes up, whether as part of a system reload or an interface reload, the system waits 300 seconds (5 minutes) to bring up VRRP on that interface. vrrp delay reload — sets the delay time for VRRP initialization after a system reboot. vrrp delay reload Set the delay time for VRRP initialization after a system reboot.
Related Command vrrp delay minimum — sets the delay time for VRRP initialization after a line card reboot. vrrp-group Assign a VRRP ID to an interface. You can configure up to 12 VRRP groups per interface. Syntax Parameters vrrp-group vrrp-id vrrp-id Enter a number as the group ID. The range is from 1 to 255. Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific.
• debug vrrp ipv6 • show vrrp ipv6 • vrrp-ipv6-group The following commands apply to IPv4 and IPv6: • advertise-interval • description • disable • hold-time • preempt • priority • show config • virtual-address clear counters vrrp ipv6 Clear the counters recorded for IPv6 VRRP groups. Syntax Parameters clear counters vrrp ipv6 [vrid | vrf vrf-name] vrid (OPTIONAL) Enter the number of an IPv6 VRRP group. The range is from 1 to 255.
debug vrrp ipv6 Allows you to enable debugging of VRRP. Syntax Parameters debug vrrp ipv6 interface [vrid] {all | packets | state | timer} interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a Port Channel interface, enter the keywords portchannel then a number. • For a VLAN interface, enter the keyword vlan then the VLAN ID. The VLAN ID range is from 1 to 4094.
Usage Information Version Description 8.4.1.0 Introduced on E-Series ExaScale, C-Series, and S-Series. Support was added for IPv6 VRRP groups in non-default VRF instances. 8.3.2.0 Introduced on the E-Series TeraScale. If no options are specified, debug is active on all interfaces and all VRRP groups. show vrrp ipv6 View the IPv6 VRRP groups that are active. If no VRRP groups are active, the Dell Networking OS returns No Active VRRP group.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. 8.3.2.0 Introduced on the E-Series TeraScale. The following describes the show vrrp ipv6 command shown in the following example. Line Beginning with Description GigabitEthernet... Displays the Interface, the VRRP group ID, and the network address. If the interface is no sending VRRP packets, 0.0.0.0 appears as the network address.
Line Beginning with Example Description • UP or DOWN state of the tracked interface or object (Up or Dn). • Interface type and slot/port or object number, description, and time since the last change in the state of the tracked object. • Cost to be subtracted from the VRRP group priority if the state of the tracked interface/object goes DOWN.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.3.2.0 Introduced on the E-Series TeraScale. The VRRP group only becomes active and sends VRRP packets when a link-local virtual IP address is configured. When you delete the virtual address, the VRRP group stops sending VRRP packets. • When VRF microcode is not loaded in CAM, the VRID for a VRRP group is the same as the VRID number configured with the vrrp-group or vrrp-ipv6group command.