Users Guide

EXEC Privilege mode
redundancy force-failover stack-unit
Example of the redundancy force-failover stack-unit Command
Dell#redundancy force-failover stack-unit
System configuration has been modified. Save? [yes/no]: yes
Proceed with Stack-unit hot failover [confirm yes/no]:yes
Dell#
Disabling Auto-Reboot
To disable auto-reboot, use the following command.
Prevent a failed stack unit from rebooting after a failover.
CONFIGURATION mode
redundancy disable-auto-reboot
Manually Synchronizing Management and Standby Units
To manually synchronize Management and Standby units at any time, use the following command.
Manually synchronize Management and Standby units.
EXEC Privilege mode
redundancy synchronize full
Pre-Configuring a Stack Unit Slot
You may also pre-configure an empty stack unit slot with a logical stack unit.
To pre-configure an empty stack unit slot, use the following command.
Pre-configure an empty stack unit slot with a logical stack unit.
CONFIGURATION mode
stack-unit unit_id provision S3124
Example of Viewing a Logical Configuration of a Pre-Configured Stack Unit
After creating the logical stack unit, you can configure the interfaces on the stack unit as if it is present.
Dell#show system stack-unit 1
-- Unit 1 --
Unit Type : Member Unit
Status : not present
Dell#con
Dell(conf)#stack-unit 1 provision S3124
Dell(conf)#end
Dell#show system stack-unit 1
-- Unit 1 --
Unit Type : Member Unit
Status : not present
Required Type : S3124 - 28-port GE/TE (S3100)
High Availability (HA)
285