Administrator Guide

Removing a Unit from a Stack
The running-configuration and startup-configuration are synchronized on all stack units. A stack member that is disconnected from the
stack maintains this configuration.
To remove a stack member from the stack, disconnect the stacking cables from the unit. You may do this at any time, whether the unit is
powered or unpowered, online or offline.
NOTE: If you remove a unit in the middle of the daisy chain stack, the stack is split into multiple parts and each forms a
new stack according to the stacking algorithm described throughout this chapter.
The following example shows removing a stack member (before).
DellEMC#show system brief
Stack MAC : 34:17:17:18:19:1e
Reload-Type : normal-reload [Next boot : normal-reload]
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
---------------------------------------------------------------------------------
1 Member online S3148P S3148P 1-0(0-4679) 54
2 Management online S3148P S3148P 1-0(0-4679) 54
3 Standby online S3148P S3148P 1-0(0-4679) 54
4 Member not present
5 Member not present
6 Member not present
7 Member not present
8 Member not present
9 Member not present
10 Member not present
11 Member not present
12 Member not present
-- Module Info --
Unit Module No Status Module Type Ports
---------------------------------------------------------------------------
1 1 online S3148P-10GE-2X10BaseT 2
2 1 online S3148P-10GE-2SFP+ 2
3 1 online S3148P-10GE-2X10BaseT 2
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
---------------------------------------------------------------------------
1 1 up AC up 7888
1 2 down UNKNOWN absent NA
2 1 up AC up NA
2 2 absent absent NA
3 1 absent absent 0
3 2 up AC up 7888
-- Fan Status --
Unit Bay TrayStatus Fan1 Speed Fan2 Speed
------------------------------------------------------------------------------------
1 1 up up 7164 up 7058
2 1 up up 6956 up 7058
3 1 up up 7058 up 7164
Speed in RPM
DellEMC#
The following example shows removing a stack member (after).
03:43:31: %STKUNIT2-M:CP %CHMGR-2-STACKUNIT_DOWN: stack-unit 1 down - card removed
03:43:31: %STKUNIT2-M:CP %IFMGR-1-DEL_PORT: Removed port: Gi 1/1-1/48, Te 1/49-1/50,
DellEMC#show system brief
Stack MAC : 34:17:17:18:19:1e
Reload-Type : normal-reload [Next boot : normal-reload]
-- Stack Info --
Stacking