Administrator Guide

Line Description
TX Power High
Warning threshold
Factory-defined setting. Value can differ between SFP and SFP+.
RX Power High
Warning threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Temp Low
Warning threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Voltage Low
Warning threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Bias Low Warning
threshold
Factory-defined setting. Value can differ between SFP and SFP+.
TX Power Low
Warning threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Power Low
Warning threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Temperature Current temperature of the SFPs. If this temperature crosses Temp High alarm/warning
thresholds, the temperature high alarm/warning flag is set to true.
Voltage Current voltage of the SFPs. If this voltage crosses voltage high alarm/warning
thresholds, the voltage high alarm/warning flag is set to true.
Tx Bias Current Present transmission (Tx) bias current of the SFP. If this crosses bias high alarm/warning
thresholds, the TX bias high alarm/warning flag is set to true. If it falls below the low
alarm/warning thresholds, the TX bias low alarm/warning flag is set to true.
Tx Power Present Tx power of the SFP. If this crosses Tx power alarm/warning thresholds, the Tx
power high alarm/warning flag is set to true. If it falls below the low alarm/warning
thresholds, the Tx power low alarm/ warning flag is set to true.
Rx Power Present receiving (Rx) power of the SFP. This value is either average Rx power or OMA.
This depends on the Rx Power measurement type displayed above. If this crosses Rx
power alarm/warning thresholds, the Rx power high alarm/warning flag is set to true. If it
falls below the low alarm/warning thresholds, the Rx power low alarm/warning flag is set
to true.
Data Ready state
Bar
This field indicates that the transceiver has achieved power up and data is ready. This is
set to true if data is ready to be sent and set to false if data is being transmitted.
Rx LOS state This is the digital state of the Rx_LOS output pin. This is set to true if the operating
status is down.
Tx Fault state This is the digital state of the Tx Fault output pin.
Rate Select state This is the digital state of the SFP rate_select input pin.
RS state This is the reserved digital state of the pin AS(1) per SFF-8079 and RS(1) per SFF-8431.
Tx Disable state If the admin status of the port is down then this flag is set to true.
Temperature High
Alarm Flag
This can be either true or false, depending on the Current voltage value displayed above.
Voltage High
Alarm Flag
This can be either true or false, depending on the Current Temperature value displayed
above.
Tx Bias High Alarm
Flag
This can be either true or false, depending on the present Tx bias current value displayed
above.
Tx Power High
Alarm Flag
This can be either true or false, depending on the Current Tx bias power value displayed
above.
Rx Power High
Alarm Flag
This can be either true or false, depending on the Current Rx power value displayed
above.
Temperature Low
Alarm Flag
This can be either true or false, depending on the Current Temperature value displayed
above.
648 Interfaces