Version Description
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
8.1.1.0 Introduced on the E-Series.
7.5.1.0 Introduced on the C-Series.
7.6.1.0 Introduced on the E-Series
Usage Information
If you disable auto failover, enter the redundancy auto-failover-limit
(without any parameters) to set auto failover to the default parameters (Count 3,
Period 60 minutes). To view the redundancy status, use the show redundancy
command.
When you change one or both of the optional parameters, Dell Networking OS
checks that the interval between auto failovers is more than five (5) minutes. If the
interval is less, Dell Networking OS returns a configuration error message.
redundancy disable-auto-reboot
Prevent the system from auto-rebooting the failed module.
Syntax
redundancy disable-auto-reboot stack-unit [0–11 | members}
[rpm| card number | all]
To return to the default, use the no redundancy disable-auto-reboot
stack-unit rpm command.
Parameters
rpm Enter the keyword rpm to disable auto-reboot of the failed
RPM.
stack-unit Enter the keyword stack-unit then the stack-unit ID
number.
Default Disabled — the failed module is automatically rebooted.
Command Modes CONFIGURATION
Command History
This guide is platform-specific. For command information about other platforms,
see the relevant Dell Networking OS Command Line Reference Guide.
Version Description
9.8(2.0) Introduced on the S3100 series.
684