Concept Guide

Conguring NTP control key password
The Network Time Protocal daemon (NTPD) design uses NTPQ to congure NTPD. NTP control key supports encrypted and unencrypted
password options. The ntp control-key- passwd command authenticates NTPQ packets. The default control-key-passwd
authenticates the NTPQ packets until the user changes the control-key using the ntp control-key- passwd command.
To congure NTP control key password, use the following command.
Congure NTP control key password.
CONFIGURATION mode
ntp control-key-passwd [encryption-type] password
Dell EMC Networking OS Time and Date
You can set the time and date using the Dell EMC Networking OS CLI.
Conguration Task List
The following is a conguration task list for conguring the time and date settings.
Setting the Time and Date for the Switch Software Clock
Setting the Timezone
Setting Daylight Saving Time Once
Setting Recurring Daylight Saving Time
Setting the Time and Date for the Switch Software Clock
You can change the order of the month and day parameters to enter the time and date as time day month year. You cannot delete the
software clock.
The software clock runs only when the software is up. The clock restarts, based on the hardware clock, when the switch reboots.
To set the software clock, use the following command.
Set the system software clock to the current time and date.
EXEC Privilege mode
clock set time month day year
time: enter the time in hours:minutes:seconds. For the hour variable, use the 24-hour format; for example, 17:15:00 is 5:15 pm.
month: enter the name of one of the 12 months in English. You can enter the name of a day to change the order of the display to
time day month year.
day: enter the number of the day. The range is from 1 to 31. You can enter the name of a month to change the order of the display
to time day month year.
year: enter a four-digit number as the year. The range is from 1993 to 2035.
Example of the clock set Command
DellEMC#clock set 16:20:00 9 september 2017
DellEMC#
System Time and Date
935