Deployment Guide

35 VxRail Networking Guide with Dell EMC S4148-ON Switches | version 1.0
VLT Configuration
vlt-port-channel 2
no shutdown
vlt-port-channel 2
no shutdown
Example for 100GbE uplink ports, this
requires switch-port profile-1
interface ethernet 1/1/25
description "100Gb Uplink to Customer 2"
channel-group 2 mode active
no ip address
no shutdown
!
interface ethernet 1/1/26
description "100Gb Uplink to Customer 2"
channel-group 2 mode active
no ip address
no shutdown
interface ethernet 1/1/25
description "100Gb Uplink to Customer 2"
channel-group 2 mode active
no ip address
no shutdown
!
interface ethernet 1/1/26
description "100Gb Uplink to Customer 2"
channel-group 2 mode active
no ip address
no shutdown
Example for 40GbE uplink ports, this
requires switch-port profile-2
interface ethernet 1/1/25
description "40Gb Uplink to Customer 2"
channel-group 2 mode active
no ip address
no shutdown
!
interface ethernet 1/1/26
description "40Gb Uplink to Customer 2"
channel-group 2 mode active
no ip address
no shutdown
interface ethernet 1/1/25
description "40Gb Uplink to Customer 2"
channel-group 2 mode active
no ip address
no shutdown
!
interface ethernet 1/1/26
description "40Gb Uplink to Customer 2"
channel-group 2 mode active
no ip address
no shutdown
Example for 10GbE uplink ports, this
requires switch-port profile-1
interface ethernet 1/1/23
description "10Gb Uplink to Customer 1"
channel-group 1 mode active
no ip address
no shutdown
!
interface ethernet 1/1/24
description "10Gb Uplink to Customer 1"
channel-group 1 mode active
no ip address
no shutdown
interface ethernet 1/1/23
description "10Gb Uplink to Customer 1"
channel-group 1 mode active
no ip address
no shutdown
!
interface ethernet 1/1/24
description "10Gb Uplink to Customer 1"
channel-group 1 mode active
no ip address
no shutdown