White Papers

11 Dell EMC OS10 FCoE with Redundant Links Configuration Cheat Sheet | 1.0
mk-S4148U-02# conf
mk-S4148U-02(config)# int range eth1/1/53-1/1/54
mk-S4148U-02(conf-eth1/1/53-1/1/54)# des VLTi_Members
mk-S4148U-02(conf-eth1/1/53-1/1/54)# no switchport
mk-S4148U-02(conf-eth1/1/53-1/1/54)# exit
mk-S4148U-02(config)#
mk-S4148U-02(config)# vlt-domain 1
mk-S4148U-02(conf-vlt-1)# discovery-interface eth1/1/53
mk-S4148U-02(conf-vlt-1)# discovery-interface eth1/1/54
mk-S4148U-02(conf-vlt-1)# end
mk-S4148U-02#
4. Configure DCBX
mk-S4148U-02# conf
mk-S4148U-02(config)# dcbx enable
mk-S4148U-02(config# end
mk-S4148U-02#
5. Configure PFC and relevant parameters to be used by FCoE traffic.
mk-S4148U-02# conf
mk-S4148U-02(config)# class-map type network-qos fcoematch
mk-S4148U-02(config-cmap-nqos)# match qos-group 3
mk-S4148U-02(config-cmap-nqos)# exit
mk-S4148U-02(config)# policy-map type network-qos PFC
mk-S4148U-02(config-pmap-c-nqos)# pause
mk-S4148U-02(config-pmap-c-nqos)# pfc-cos 3
mk-S4148U-02(config-pmap-c-nqos)# end
mk-S4148U-02#
6. Configure port-channels 30 and 50 and configure the FCF facing port. This
is the interface connected to the FC switch.
mk-S4148U-02# conf
mk-S4148U-02(config)# int po30
mk-S4148U-02(conf-if-po-30)# des Upstream_PO30
mk-S4148U-02(conf-if-po-30)# switchport mode trunk
mk-S4148U-02(conf-if-po-30)# switchport access vlan 1
mk-S4148U-02(conf-if-po-30)# switchport trunk allowed vlan 1001,100
mk-S4148U-02(conf-if-po-30)# vlt-port-channel 30
mk-S4148U-02(conf-if-po-30)# fip-snooping port-mode fcf
mk-S4148U-02(conf-if-po-30)# exit
mk-S4148U-02(config)# int eth1/1/49
mk-S4148U-02(conf-if-eth1/1/49)#
7. Configure PFC and apply them on the proper interfaces. In this case both
port-channels (30 and and physical interfaces in both directions
(upstream and downstream)
mk-S4148U-02# conf
mk-S4148U-02(config)# interface eth1/1/46